Pasar al contenido principal

Propiedades ópticas y biomecánicas de la córnea y su impacto refractivo

RYC-2016-20471

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ALICANTE

Resultados relacionados

Resultados totales (Incluyendo duplicados): 104
Encontrada(s) 2 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Predictive value of intracrystalline interphase point measured by optical low-coherence reflectometry for the estimation of the anatomical position of an intraocular lens after cataract surgery

  • Castro-Alonso, Francisco Javier
  • Bordonaba-Bosque, Daniel
  • Piñero, David P.
  • Latre-Rebled, Beatriz
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To investigate the predictive value of the intracrystalline interphase point (ICIP) measured with optical low-coherence reflectometry (OCLR) to estimate the final lens position (FLP) of an intraocular lens (IOL) after cataract surgery. Setting: Alcañiz Hospital, Teruel, Spain. Design: Single-center retrospective descriptive study. Methods: Patients undergoing cataract surgery were enrolled. They were grouped according to the IOL implanted as follows: Group 1, Acrysof IQ aspheric SN60WF IOL (77 eyes); Group 2, enVista MX60 IOL (71 eyes); Group 3, CT Asphina 409 IOL (44 eyes). An OCLR-based biometer (Lenstar LS 900 system) was used for biometric measurements preoperatively and at 4 to 5 weeks postoperatively. Results: The study comprised 192 eyes of 174 patients (mean age: 76.4 years). One hundred seventy eyes (88.5%) eyes showed an absolute refractive prediction error (ARPE) less than 0.50 diopters (D). The mean ARPE was 0.25 D ± 0.21 (SD). Significantly higher FLP values were found in Group 2 compared with the other two groups (P < .001). Significantly lower ICIP values were found in the eyes with an ARPE of 0.50 D or more compared with eyes that had an ARPE less than 0.50 D in Group 1 (P = .042) and Group 2 (P = .023). The correlation of the FLP with the ICIP was good in all three groups (r ≥ 0.74, P <.001). Three linear expressions were obtained to predict the FLP from the ICIP and other preoperative data (R2: 0.85, 0.69, and 0.49 in Groups 1, 2, and 3, respectively). Conclusions: The position of the ICIP measured with OCLR correlated with the FLP after cataract surgery, and it can be used to optimize IOL power calculations.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Randomised placebo-controlled clinical trial evaluating the impact of a new visual rehabilitation program on neuroadaptation in patients implanted with trifocal intraocular lenses

  • Piñero, David P.
  • Maldonado, Miguel J.
  • Molina-Martín, Ainhoa
  • García-Sánchez, Noelia
  • Ramón, María L.
  • Rincón, José L.
  • Holgueras, Alfredo
  • Arenillas, Juan F.
  • Planchuelo-Gómez, Álvaro
  • Leal-Vega, Luis
  • Coco-Martin, María Begoña
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To evaluate the efficacy of a new visual training program for improving the visual function in patients implanted with trifocal intraocular lenses (IOLs). Methods Randomised placebo-controlled clinical trial enrolling 60 subjects (age, 47–75 years) undergoing cataract surgery with implantation of trifocal diffractive IOL. Home-based active visual training was prescribed immediately after surgery to all of them (20 sessions, 30 min): 31 subjects using a serious game based on Gabor patches (study group) and 29 using a placebo software (placebo group). Visual acuity, contrast sensitivity (CS), and perception of visual disturbances (QoV questionnaire) were evaluated before and after training. Likewise, in a small subgroup, resting-state functional magnetic resonance imaging (rs-fMRI) analysis was performed. Results No significant differences were found between groups in compliance time (p = 0.70). After training, only significant improvements in monocular uncorrected intermediate visual acuity were found in the study group (p ≤ 0.01), although differences between groups did not reach statistical significance (p ≥ 0.11). Likewise, significantly better binocular far CS values were found in the study group for the spatial frequencies of 6 (p = 0.01) and 12 cpd (p = 0.03). More visual symptoms of the QoV questionnaire experienced a significant change in the level of bothersomeness in the study group. Rs-fMRI revealed the presence significant changes reflecting higher functional connectivity after the training with the serious game. Conclusions A 3-week visual training program based on the use of Gabor patches after bilateral implantation of trifocal diffractive IOLs may be beneficial for optimising the visual function, with neural changes associated suggesting an acceleration of neuroadaptation. Trial registration ClinicalTrials.gov, NCT04985097. Registered 02 August 2021, https://clinicaltrials.gov/(NCT04985097).
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Long-term Results of a Combined Procedure of Cataract Surgery and Descemet Membrane Endothelial Keratoplasty With Stromal Rim

  • Studeny, Pavel
  • Hlozankova, Katerina
  • Krizova, Deli
  • Netukova, Magdalena
  • Veith, Miroslav
  • Mojzis, Peter
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the long-term results of combining cataract surgery, intraocular lens (IOL) implantation, and Descemet membrane endothelial keratoplasty with peripheral stromal support (DMEK-S). Methods: The outcomes of 107 eyes of 37 patients who had undergone a combination of cataract surgery, IOL implantation, and DMEK-S between October 2007 and February 2015 were retrospectively evaluated. The average follow-up duration was 18.2 ± 18.3 months (range, 6–84 months). Changes in uncorrected and corrected distance visual acuity, spherical equivalent, and corneal endothelial cell density were analyzed. Intraoperative and postoperative complications were also recorded. Results: The mean logMAR uncorrected distance visual acuity improved from 0.92 ± 0.60 preoperatively to 0.33 ± 0.33, 0.28 ± 0.25, 0.24 ± 0.20, and 0.27 ± 0.27 at 6, 12, 24, and 36 months postoperatively (P < 0.001), respectively. The mean logMAR corrected distance visual acuity improved from 0.62 ± 0.65 preoperatively to 0.17 ± 0.29, 0.13 ± 0.21, 0.07 ± 0.16, and 0.11 ± 0.23 at 6, 12, 24, and 36 months postoperatively (P < 0.001), respectively. The mean endothelial cell density decreases were 50.7% ± 21.1%, 50.8% ± 19.8%, 60.7% ± 16.6%, 62.2% ± 11.8%, and 61.8% ± 20.0% at 6, 12, 24, 36, and 48 months after surgery, respectively. Similar trends, although with slightly better visual outcomes, were found in the subgroup of patients without other eye diseases. The mean final deviation from intended spherical equivalent was 0.77 ± 1.19 D, representing a hyperopic shift. Conclusions: A combined procedure of cataract surgery, IOL implantation, and DMEK-S is an effective method of treatment in patients with combined corneal disease and cataract, maintaining visual rehabilitation in the long term. Future developments should be performed to minimize the incidence of complications.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization of Dysfunctional Lens Index and Opacity Grade in a Healthy Population

  • Martínez-Plaza, Elena
  • Ruiz Fortes, Pedro
  • Soto-Negro, Roberto
  • Hernández Rodríguez, Carlos Javier
  • Molina-Martín, Ainhoa
  • Arias-Puente, Alfonso
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This study enrolled 61 volunteers (102 eyes) classified into subjects < 50 years (group 1) and subjects ≥ 50 years (group 2). Dysfunctional Lens Index (DLI); opacity grade; pupil diameter; and corneal, internal, and ocular higher order aberrations (HOAs) were measured with the i-Trace system (Tracey Technologies). Mean DLI was 8.89 ± 2.00 and 6.71 ± 2.97 in groups 1 and 2, respectively, being significantly higher in group 1 in all and right eyes (both p < 0.001). DLI correlated significantly with age (Rho = −0.41, p < 0.001) and pupil diameter (Rho = 0.20, p = 0.043) for all eyes, and numerous internal and ocular root-mean square HOAs for right, left, and all eyes (Rho ≤ −0.25, p ≤ 0.001). Mean opacity grade was 1.21 ± 0.63 and 1.48 ± 1.15 in groups 1 and 2, respectively, with no significant differences between groups (p ≥ 0.29). Opacity grade significantly correlated with pupil diameter for right and all eyes (Rho ≤ 0.33, p ≤ 0.013), and with some ocular root-mean square HOAs for right and all eyes (Rho ≥ 0.23, p ≤ 0.020). DLI correlates with age and might be used complementary to other diagnostic measurements for assessing the dysfunctional lens syndrome. Both DLI and opacity grade maintain a relationship with pupil diameter and internal and ocular HOAs, supporting that the algorithms used by the device may be based, in part, on these parameters.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Geometrical characterization of the corneo-scleral transition in normal patients with Fourier domain optical coherence tomography

  • Seguí-Crespo, Mar
  • Ariza-Gracia, Miguel Á.
  • David Sixpene, Nelva de Luisa
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
  • Seguí-Crespo, Mar|||/items/c0870c8e-487b-4032-aef9-e8e0d18ef087
Purpose To characterize the geometry at the corneo-scleral transition for a normal population and its correlation with other anatomic parameters of the eyeball. Methods Transversal epidemiologic study on a sample of 100 individuals (right eye) in different ethnic groups (Africans and Caucasians). All of them were examined with Fourier domain optical coherence tomography, auto-refractometer, topographer, and biometer to obtain the corneo-scleral angle (CSA) and additional clinical parameters. The dataset was analyzed to determine correlations between different anatomical parameters and nasal (CSAn) and temporal CSA (CSAt) values. Results The CSAt presents a significant but low correlation with the anterior chamber depth—ACD (r = 0.25; p = 0.024), the white-to-white (W–W) distance (r = 0.27; p = 0.022), and the anterior chamber volume (r = 0.25; p = 0.016). CSAn did not correlate significantly with any clinical variable, with all values being lower than 179° (concave). Ethic groups presented significant differences for pachymetry (Pac) and corneal volume (p = 0.033 and p = 0.014), being greater for Caucasians, and temporal corneo-iridial angle (p = 0.006), being greater for Africans. CSA presented and inverse correlation with age. Conclusions The CSAn presents a more concave profile for the normal population, whereas the CSAt presents a planar-convex profile with a great influence of age. In particular, the older the patient, the more convex the CSAt is. This age-related evolution of the CSAt and the concavity on the nasal direction must be considered when prescribing scleral contact lenses or when performing limbal incisions during refractive interventions.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Efficacy of astigmatic correction after femtosecond laser-guided cataract surgery using intraoperative aberrometry in eyes with low-to-moderate levels of corneal astigmatism

  • Orts, Paz
  • Piñero, David P.
  • Aguilar, Salvador
  • Tañá, Pedro
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To evaluate the efficacy of astigmatic correction with two types of toric intraocular lenses (IOLs) after femtosecond laser-assisted cataract surgery (FLACS) in eyes with low-to-moderate corneal astigmatism using intraoperative aberrometry for optimizing the position of the toric IOL. Methods Retrospective study includes a total of 99 eyes of 73 patients with anterior keratomeric astigmatism ≤ 3 D and undergoing FLACS (Catalys, Johnson & Johnson Vision) with implantation of a monofocal (Ankoris, PhysIOL) or a multifocal toric IOL with the same platform (Pod FT, PhysIOL). In all cases, intraoperative aberrometry was used (Optiwave refractive analysis, ORA, system, Alcon). Visual and refractive outcomes were evaluated preoperatively and at 4 months after surgery with vector analysis of astigmatic changes. Results A total of 89.9%, 93.9% and 97.0% showed a postoperative sphere, cylinder and spherical equivalent within ± 0.50 D, respectively. Mean difference vector (DV) was 0.22 ± 0.27 D, mean magnitude of error (ME) was 0.13 ± 0.29 D, and mean angle of error (AE) was 1.52 ± 11.64°. Poor correlations of preoperative corneal astigmatism with DV (r = − 0.032, p = 0.833), ME (r = − 0.344, p = 0.001) and AE (r = − 0.094, p = 0.377) were found. Likewise, no statistically significant differences were found between monofocal and multifocal toric IOL subgroups in DV (p = 0.580), ME (p = 0.702) and AE (p = 0.499). Conclusions The combination of FLACS and intraoperative aberrometry to optimize the position of a toric IOL allows a very efficacious correction of preexisting low-to-moderate corneal astigmatism.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Agreement of Tear Break-Up Time and Meniscus Height between Medmont E300 and Visionix VX120+

  • Martínez-Plaza, Elena
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The goal of this study was to analyze the agreement between the Medmont E300 and the Visionix VX120+ systems in terms of non-invasive tear break-up time (NIBUT) and tear meniscus height (TMH) measurements. A total of 60 eyes (30 healthy subjects) were enrolled. NIBUT and TMH were evaluated with Medmont E300; first NIBUT, NIBUT50%, and TMH were evaluated with Visionix VX120+. Both evaluations were performed in a random order by the same clinician for right, left, and both eyes. The Medmont E300 provided significantly higher NIBUT than Visionix VX120+ for first NIBUT in right, left, and both eyes (p ≤ 0.003) and NIBUT50% in left and both eyes (p ≤ 0.042). The TMH measured with VX120+ was significantly higher than with Medmont E300 considering both eyes (p = 0.037). No significant correlations were found between both devices for either NIBUT (p ≥ 0.11) or TMH (p ≥ 0.09). Passing–Bablok regression analyses revealed poor agreement between devices for NIBUT and TMH outcomes. VX120+ is expected to provide substantial lower first NIBUT values than the NIBUT measured by Medmont E300. Clinicians should consider not using both instruments as interchangeable for dry eye diagnosis.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Structural changes associated to orthokeratology: A systematic review

  • Sánchez-García, Alicia
  • Ariza-Gracia, Miguel Á.
  • Büchler, Phillippe
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To summarize the peer-reviewed literature on corneal structural changes after orthokeratology (OK) and to analyze the quality of the studies published. Methods: An exhaustive search was carried out in the databases Pubmed MEDLINE, Web of Science and Scopus. Original studies in English, with a cohort or experimental design and analyzing the cellular and structural changes of the cornea after OK fitting for myopia correction were selected. The NewCastle-Ottawa Assessment Scale (NOS) tool was used to analyze the quality of the studies selected. Results: The search provided a total of 1837 articles, of which 12 were selected following the inclusion and exclusion criteria. All studies had good quality according to the NOS tool (mean 7.58 ± 1.31). The mean ± standard deviation follow-up period of lens wear in the studies evaluated was 19.27 ± 33.97 months. The following reversible changes after OK have been reported: reduction in central epithelial basal cells, an increase in height and especially in width of superficial epithelial cells, as well as an increase in central stromal thickness and in the number of active keratocytes. Concerning corneal endothelium, only changes in terms of polymegathism were reported that were compatible with those observed for other types of contact lens wear. In relation to corneal sensitivity, there was a reduction during the use of OK, as well as in the nervous density of the sub-basal plexus at the central level, with some contradictory outcomes concerning the reversibility of these changes. Conclusion: OK produces reversible structural changes in the central epithelium and central anterior corneal stroma, as well as a decrease in the nerve density of the sub-basal plexus and corneal sensitivity. The quality of published studies evaluating these aspects is good, although more studies are needed to evaluate longer follow-up changes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization of Corneoscleral Geometry Using Fourier Transform Profilometry in the Healthy Eye

  • Piñero, David P.
  • Martínez-Abad, Antonio
  • Soto-Negro, Roberto
  • Ariza-Gracia, Miguel Á.
  • Carracedo, Gonzalo
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Objective: To characterize peculiarities of the corneoscleral geometry in healthy eyes. Methods: This is a prospective case series including 88 healthy eyes of 88 patients with an age ranging from 21 to 73 years. A complete ocular examination was performed with emphasis on the analysis of the corneoscleral topographic profile with the Fourier transform profilometer Eye Surface Profiler (Eaglet-Eye BV, Houten, the Netherlands). The distribution of different topographic parameters was evaluated, as well as the correlations between corneal and scleroconjunctival parameters. Results: Mean values of 8.64±0.37 (range, 7.81–9.50 mm), 6.06±0.52 (4.88–7.63 mm) and 11.93±1.32 mm (8.17–15.89 mm) were obtained for inner, limbal, and outer best-fit sphere, respectively. Mean values of 8.54±0.38 (7.86–9.66 mm) and 13.35±1.29 mm (11.05–17.31 mm) were obtained for mean corneal and scleral radius, respectively. Regarding tangent angles at limbus, mean values of 35.31±6.55°, 38.76±5.90°, 32.75±7.04°, and 25.91±8.99° were obtained for nasal, temporal, superior, and inferior angles, respectively. Mean difference between temporal and nasal sagittal heights increased from −1.48±120.70 μm for a chord of 11 mm to 73.53±236.55 μm for a chord of 14 mm. A weak but statistically significant correlation was found between corneal and scleral radii (r=0.325, P=0.004). The maximum sagittal height for a diameter of 12 mm was significantly correlated with flattest keratometry, astigmatism, corneal diameter, and corneal eccentricity (R2: 0.77, P<0.001). Conclusions: The scleroconjunctival surface in the healthy eye presents some level of nasotemporal asymmetry that is higher with increasing diameters of analysis.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

New method to improve the quality of vision in cataractous keratoconus eyes

  • Miret, Juan Jose
  • Camps, Vicente J.
  • García Llopis, Celia
  • Caballero, María T.
  • Fez Saiz, Dolores de
  • Piñero, David P.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • García Llopis, Celia|||/items/41f4c99c-ea0d-44a5-9149-f27dfd529b56
  • Miret, Juan Jose|||/items/3f91f39a-e384-43e0-9f3a-c05361bb5568
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
To analyze using optical simulations if the proper use of a segmented intraocular lens (IOL) can improve the visual outcomes compared to the implantation of a spherical monofocal IOL. The wavefront profile of the Mplus (Oculentis) and a monofocal IOLs with the phase transformation introduced by each IOL were calculated using a Hartmann-Shack wavefront sensor. In addition, the wavefront profile of schematic eye models of various keratoconus conditions was obtained and was propagated to the IOLs. The optical performance of such combination was obtained after combining ray tracing and Fourier optics. A pre-clinical validation was also evaluated incorporating clinical data from three different keratoconus eyes of three patients. The implantation of the Mplus IOL can compensate or reduce the overall coma of the eye with keratoconus improving the quality of vision compared with a spherical monofocal IOL due to lower displacements of the retinal image or tilting in keratoconus. All theoretical simulations were confirmed afterwards by mean of a preclinical validation. The use of a standard toric segmented IOL with a proper orientation and selection of the addition can improve the optical quality of the keratoconus eye compared to the use of a monofocal spherical IOL.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Active Vision Therapy for Anisometropic Amblyopia in Children: A Systematic Review

  • Hernández Rodríguez, Carlos Javier
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. The aim of the study was evaluation of the scientific evidence about the efficacy of vision therapy in children and teenagers with anisometropic amblyopia by performing a systematic literature review. Methods. A search was performed using 3 searching strategies in 4 different databases (PubMed, Web of Science, Scopus, and PruQuest). The quality of the included articles was evaluated using two tools for the risk of bias assessment, ROBINS-I for nonrandomized studies of intervention (NRSI), and ROB 2.0 for randomized clinical trials. Results. The search showed 1274 references, but only 8 of them passed the inclusion criteria after the complete text review. The articles that were finally included comprised 2 randomized control trials and 6 nonrandomized studies of intervention. These articles provided evidence supporting the efficacy of vision therapy for the treatment of anisometropic amblyopia in children and teenagers. Assessment of the risk of bias showed an appropriate risk of bias for the randomized control trials, but a high risk of bias for nonrandomized studies of intervention (NRSI). A main source of risk of bias for NRSI was the domain related to the measurements of the outcomes, due to a lack of double-blind studies. Conclusion. Vision therapy is a promising option for the treatment of anisometropic amblyopia in children and teenagers. However, the level of scientific evidence provided by the studies revised is still limited, and further randomized clinical trials are necessary to confirm the results provided to date and to optimize the vision therapy techniques by knowing the specific neural mechanisms involved.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Expression levels of aldose reductase enzyme, vascular endothelial growth factor, and intercellular adhesion molecule-1 in the anterior lens capsule of diabetic cataract patients

  • Bessa, Amr S.
  • Ragab, Ahmed M.
  • Nassra, Rasha A.
  • Piñero, David P.
  • Shaheen, Mohamed Shafik
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To compare the levels of aldose reductase (ALR) enzyme, intercellular adhesion molecule-1 (ICAM-1), and vascular endothelial growth factor (VEGF) in the anterior lens capsule of diabetic versus nondiabetic patients. Setting: Alexandria Main University Hospital, Alexandria, Egypt. Design: Prospective case-control study. Methods: The study enrolled patients undergoing cataract extraction and divided them into 3 groups: eyes that had proliferative diabetic retinopathy (PDR), eyes that had nonproliferative diabetic retinopathy (NPDR), and nondiabetic eyes. The anterior lens capsules were obtained by performing femtosecond laser–assisted capsulorhexis. Concentrations of ALR, ICAM-1, and VEGF in the lens capsule specimens were measured using human enzyme–linked immunosorbent assay. Results: This study comprised 200 patients (200 eyes); 51 eyes had PDR, 49 eyes had NPDR, and 100 eyes were nondiabetic. The mean ALR, ICAM-1, and VEGF levels in the anterior capsule of diabetic group were 2.84 nanogram (ng)/mL ± 0.51 (SD), 87.73 ± 22.84 picogram (pg)/mL, and 75.53 ± 14.95 pg/mL, respectively; whereas, in the nondiabetic group, they were 1.44 ± 0.17 ng/mL, 35.45 ± 2.8 pg/mL, and 33.55 ± 5.47 pg/mL, respectively. In comparing the concentrations of these mediators, both the PDR and NPDR groups had significantly higher levels compared with the nondiabetic eyes (P < .001). In addition, eyes with PDR had significantly higher levels of these mediators than eyes with NPDR (P < .001). Conclusion: The concentrations of ALR, ICAM-1, and VEGF in the anterior lens capsule of diabetic patients are significantly higher than those of nondiabetics. A significantly higher level of 3 mediators in eyes with PDR compared with those with NPDR might allow the use of them as a biomarker for severity of diabetic retinopathy.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical Outcomes with Extended Depth of Focus Intraocular Lenses in Cases in Which Multifocal Lenses Are Not Primarily Recommended

  • Álvarez-García, María Teresa
  • Fuente-García, Carlota
  • Muñoz-Puyol, Cristina
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. The purpose of the study is to evaluate the visual and patient-reported outcomes of patients undergoing cataract surgery with implantation of an extended depth of focus (EDOF) intraocular lens (IOL) who were not primarily good candidates for multifocal IOL implantation. Methods. Retrospective analysis of data from 30 eyes (23 patients) undergoing cataract surgery with implantation of one of two EDOF IOLs (follow-up: 37.9 ± 16.2 months) and prospective observational study including 106 eyes (78 patients) implanted with one of 6 different EDOF models (follow-up: 8.0 ± 7.7 months). Patients recruited had one of the following conditions: monofocal IOL implanted in the fellow eye, previous corneal refractive surgery, mild and nonprogressive maculopathy or glaucoma, age > 75 years, amblyopia, or previous vitrectomy. Results. In the retrospective phase, significant improvements were found in uncorrected distance (UDVA), corrected distance (CDVA), and corrected near visual acuity (CNVA) (p ≤ 0.013), with a nonsignificant trend to improvement in uncorrected near visual acuity (UNVA). A total of 90% of patients were completely to moderately satisfied with the outcome achieved. In the prospective phase, significant improvements were found in UDVA, CDVA, UNVA, and CNVA (p ≤ 0.032), with a total of 85.5% of patients being completely to moderately satisfied (dissatisfaction 3.3%). In both phases, extreme difficulties were only reported by a limited percentage of patients for performing some near vision activities. Conclusions. EDOF IOLs seem to be a viable option for providing an efficient visual rehabilitation with good levels of patient satisfaction and spectacle independence associated in patients that are not primarily good candidates for multifocal IOL implantation.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS

  • Palomino-Bautista, Carlos
  • Sánchez-Jean, Rubén
  • Carmona-González, David
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p < 0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r = 0.73, p < 0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Pupil Diameter in Patients With Multifocal Intraocular Lenses

  • Fernández, Joaquín
  • Rodríguez-Vallejo, Manuel
  • Martínez, Javier
  • Burguera, Noemi
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
PURPOSE: To evaluate the distribution of pupil size in patients implanted with multifocal intraocular lenses (IOLs) and to assess the variations according to age. METHODS: A total of 168 eyes that had implantation of several multifocal IOLs and were measured at the 3-month follow-up visit were included in the analysis. The Keratograph 5M (Oculus Optikgeräte) was used to measure the photopic and mesopic pupil size, as well as the average between both (average pupil size). Eyes were stratified in four groups by age: 50 years or younger, 51 to 60 years, 61 to 70 years, and older than 70 years. RESULTS: Considering the total sample, 84.5% and 95.8% of eyes had a photopic pupil size of 3 and 3.5 mm or less, respectively. The mesopic pupil size was greater than 4.5 mm in 39.3% and greater than 5 mm in 16.7% of eyes. The average pupil size was 3.5 and 4 mm or less in 54.2% and 85.1% of eyes, respectively. Mesopic pupil size resulted in a steeper decrease with age than photopic pupil size: 0.028 versus 0.015 mm/year, respectively. Statistically significant differences were found among the four age groups (P < .0005). No significant mean differences were found between multifocal IOL models for photopic pupil size, mesopic pupil size, or average pupil size (P > .05). CONCLUSIONS: Eyes implanted with multifocal IOLs had a photopic pupil size of 3.5 mm or less and mesopic pupil size of 5 mm or less. Mesopic and photopic pupil size decreased 0.28 and 0.15 mm per decade, respectively. This information can help surgeons to understand the general functioning of multifocal IOLs whose performance varies with pupil size.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparative Analysis of Two Clinical Diagnostic Methods of the Corneoscleral Geometry

  • Bataille, Laurent
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To compare the sagittal height (SH) measurements and best fit sphere (BFS) scleral curvature obtained with two different diagnostic technologies. Methods: Prospective, nonrandomized, and comparative study analyzing 23 healthy eyes of 23 patients (age, 14–52 years) was conducted. A complete eye examination was performed including a corneoscleral topographic analysis with the Scheimpflug camera–based system Pentacam (Oculus GmbH, Wetzlar, Germany) and afterward with the Fourier domain profilometer Eye Surface Profiler (ESP) (Eaglet-Eye, Houten, the Netherlands). Differences between devices in temporal SH (TSH), nasal SH (NSH), and mean SH (MSH) measurements at 13- and 15-mm chord length and in scleral BFS were analyzed. Results: Statistically significant differences were found in TSH, NSH, and MSH obtained with Pentacam and ESP (P≤0.017), with a range of agreement from 0.21 to 1.28 mm, and a clear trend of the Pentacam system to provide higher SH measurements. Significant differences were found between Pentacam scleral BFS and ESP outer BFS (P<0.001) (range agreement, 3.57 mm). Significant correlations were found between spherical equivalent and differences between devices in 15-mm TSH (r=0.485; P=0.048), as well as between the difference between devices for some SH measurements and the magnitude of such SH values (r≥0.504; P≤0.014). Conclusion: Sagittal height and scleral BFS measurements obtained with the two devices are not interchangeable, with an increased difference in SH measures between devices in eyes with less myopic refractive error and increased SH values.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of the Efficacy of a New Dichoptic Digital Platform to Treat the Anisometropic and Isometropic Amblyopia

  • Abdal, Md Oliullah
  • Bhombal, Faiza
  • Nankani, Gul J.
  • Nankani, Sonia G.
  • Lad, Shruti
  • Dholam, Aditi
  • Kumari, Richa
  • Mahajan, Jinal
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The aim of the current study was to evaluate the results of a novel dichoptic training program using an online platform in a group of subjects with refractive amblyopia, performing a comparative analysis of unilateral and bilateral amblyopic cases. For this purpose, a retrospective study analysis of data of 161 children (4–13 years) who underwent dichoptic treatment with the Bynocs® platform (Kanohi Eye Pvt. Ltd., India) was performed. In all cases, the therapy protocol consisted of sessions of training of 30 min daily 5 times a week for 6 weeks. Best corrected visual acuity (BCVA) in the non-dominant eye improved significantly with the treatment, with a mean change of 0.39 logMAR in the whole sample (p < 0.001). Regarding binocularity, the binocular function (BF) score also experienced a significant improvement (p < 0.001), with a mean change of 1.55 with therapy in the whole sample. The BCVA of the dominant eye only improved significantly (p < 0.001) in the isometropic amblyopic subgroup. In conclusion, the use of the dichoptic therapy with the digital platform evaluated allows an effective restoration of visual acuity and binocular function in children with anisometropic and isometropic amblyopia.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Modeling and Prediction of the Immediate and Short-Term Effect of Myopic Orthokeratology

  • Sánchez-García, Alicia
  • Molina-Martín, Ainhoa
  • Ariza-Gracia, Miguel Á.
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To characterize the clinical changes occurring in the initial phase of the orthokeratology (OK) treatment for myopia correction, developing a model of prediction of the refractive changes in such phase. Methods: Prospective study enrolling 64 eyes of 32 patients (range, 20–40 years) undergoing myopic OK treatment with the reverse geometry contact lens CRT (Paragon Vision Science). Changes in uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, corneal topography, ocular aberrations, and corneal epithelial thickness were evaluated during the first hour of OK lens wear and after 1 week of OK treatment. Multiple linear regression analysis was used to obtain a model to predict the short-term refractive effect of OK. Results: The UCVA improved at each visit, reaching normal visual acuity values after a week (P<0.001) of OK treatment, which was consistent with the significant spherical equivalent (SE) reduction and central flattening (P<0.001). Multiple linear regression analysis revealed that one night change in refraction (ΔR×1N) could be predicted according to the following expression (P<0.001, R2=0.686): ΔR×1N=1.042+0.028×Age+1.014×BCET (baseline central epithelium thickness)−0.752×BKm (baseline mean keratometry)−1.405×BSE (baseline SE)+1.032×ΔR×1 h (change in SE after 1 hr of OK lens use). Similarly, a statistically relevant linear relationship was obtained for predicting the refractive change after 1 week (ΔR×1W) of OK use (P<0.001, R2=0.928): ΔR×1W=3.470−1.046×BSE−1.552×BBCVA (baseline BCVA)−0.391×BKm+0.450×ΔR×1 h. Conclusions: The immediate and short-term refractive effects of myopic OK with the reverse geometry contact lens CRT can be predicted with enough accuracy from baseline and first trial visits data.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Development of a Reference Model for Keratoconus Progression Prediction Based on Characterization of the Course of Nonsurgically Treated Cases

  • Martínez-Abad, Antonio
  • Piñero, David P.
  • Chorro, Elísabet
  • Bataille, Laurent
  • Alió, Jorge L.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate and characterize long-term clinical changes in keratoconus cases not requiring surgical treatment because of the absence of clinically significant visual degradation and to design a predictive model for the progression rate. Methods: This retrospective longitudinal study enrolled 68 nonsurgically treated keratoconic eyes of 46 patients (age range, 18–66 years), with a follow-up period of 6 years ± 12 months. Visual, refractive, topographic, and aberrometric changes were evaluated, detecting the abnormal levels of longitudinal changes in each clinical variable analyzed (percentiles 10% or 90%). Subsequently, the eyes were stratified into progression and no-progression groups based on the different variables evaluated, analyzing baseline differences between them. A progression index (PI%) was defined, and its relationship with baseline data was modeled using multiple linear regression analysis. Results: Significant differences were detected in more quantity of baseline parameters between progression and no-progression groups for changes in sphere, spherical-like and coma-like root mean square, central mean keratometry (KM3mm), corneal asphericity (Q80mm), and central astigmatism (Ast3mm). The progression index (PI%) was defined using these variables, obtaining a mean value of 24.39 ± 51.09% and a median of 1.85%. This parameter was significantly related to the baseline sphere, K23 mm (steepest central keratometry), and Q80 mm (P < 0.001, R2 = 0.429). Conclusions: More pronounced progression seems to be present in myopic eyes with central localized steepening but normal mid-periphery flattening. A new index has been defined to characterize and predict the level of progression in nonsurgically treated keratoconus in a medium–long term.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Are near visual signs and symptoms in multiple sclerosis compatible with convergence insufficiency?

  • Gil-Casas, Amparo
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Clinical relevance: Optometric management of neurodegenerative diseases is essential since visual signs, such as double vision, visual acuity reduction, or oculomotricity dysfunctions, are usually present in these subjects over the course of the disease. The present paper can guide clinicians in better managing their patients with multiple sclerosis. Background: Patients with multiple sclerosis present near vision symptoms that may be related to binocular anomalies, but these symptoms have not been investigated and related to specific signs. The aim of the present study was to evaluate the binocular vision in subjects with multiple sclerosis, and to analyse if the near visual signs and symptoms observed are compatible with those found in convergence insufficiency, as occurs in other neurodegenerative diseases. Methods: A total of 57 multiple sclerosis patients and 26 healthy controls were examined and classified as potentially compatible with convergence insufficiency according to the signs and symptoms. Clinical diagnosis of convergence insufficiency was established when subjects met the following criteria: NPC breakpoint more than 6 cm, PFV ≤ than 15Δ (base-out), and exophoria greater at near than at distance at least 4Δ. Convergence Insufficiency Symptom Survey (CISS) was administered to assess the symptomatology considering a score ≥16 as positive. Results: According to the CISS score, 54,4% of the multiple sclerosis subjects revised showed a suspect of convergence insufficiency, with a median score of 27 (IQR 9), whereas only one subject from control group (3.8%) showed this suspect. According to the diagnostic criteria based on signs, only 15.8% of multiple sclerosis patients had a real diagnosis of convergence insufficiency. Conclusion: Multiple sclerosis patients showed symptomatology compatible with convergence insufficiency, but this was not supported by the signs which showed a more esophoric tendency. The discrepancies between the signs and symptoms could be due to the questionnaire used including items that are also related to the cognitive function and other ocular abnormalities.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparison of Different Methods of Corneal Collagen Crosslinking: A Systematic Review

  • Hamida Abdelkader, Sidi Mohamed
  • Fernández, Joaquín
  • Rodríguez-Vallejo, Manuel
  • Sánchez-García, Alicia
  • Batres-Valderas, Laura
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To review the scientific literature on the comparison of the efficacy of different corneal collagen crosslinking (CXL) protocols for the treatment of progressive keratoconus. Methods: Systematic review of randomized clinical trials (RCTs) on CXL outcomes. A search was carried out using the Cochrane Library, PubMed, EMBASE, Web of Science, Ovid MEDLINE, and Scopus databases. Internal validity was analyzed by applying the filter CASPe (Critical Appraisal Skills Program Spain). Results: The search yielded 1151 articles, and among these, 14 articles met the inclusion and exclusion criteria defined. Conventional (S) crosslinking (CXL) provided better topographic outcomes than transepithelial (TE) CXL, and S-CXL had a better therapeutic effect of corneal flattening than accelerated (A) CXL. The corneal thinning after CXL was lower with hypotonic riboflavin than with riboflavin-dextran. While one study demonstrated a better therapeutic effect of corneal flattening with S-CXL than with A-CXL, another study showed similar results between both techniques. No correlation was found between the depth of the demarcation line and topographic changes, which was not a direct measure of treatment effectiveness. Quality analysis of the literature reviewed yielded a mean score of 8.64, indicating that the RCTs evaluated had an overall acceptable quality. Conclusions: Good-quality RCTs comparing CXL techniques have been conducted, and most of them suggest that epi-off CXL can be considered the standard treatment for progressive keratoconus. TE-CXL and iontophoresis-assisted CXL are mainly indicated in patients with a risk of corneal scarring and patients with pain intolerance, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Fixation Pattern Analysis With Microperimetry In Strabismic Subjects: A Pilot Study

  • Milla-Barrios, Myriam
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Objective: Strabismic amblyopia is a motor and sensory deficit produced by unilateral constant strabismus and binocular imbalance. The aim of this study was to analyse the retinal fixation pattern using microperimetry in subjects with strabismus with and without amblyopia associated, and to compare the results with those obtained in normal subjects. Methods: Prospective comparative study conducted at the Optometric Clinic of the University of Valencia and Oftalvist Alicante (Spain) including 46 eyes with ages from 3 to 16 years. Three groups were differentiated: patients with persistent strabismic amblyopia after occlusion and active therapy (group 1, 7 patients, 30.4%), strabismic patients without amblyopia (group 2, 8 patients, 34.8%) and a control group (8 patients, 34.8%). Microperimetric analysis was performed with the Macular Integrity Assessment (MAIA) system (Centervue, Padova, Italy) and using the following parameters: P1% and P2% fixation indexes, and the ellipse areas (BCEA) for 95% and 63% of points for the first 10 seconds, 30 seconds, 60 seconds, and the total examination time. Results: Significant differences were found between groups for dominant eyes in P2 calculated at 30 (p = .04) and 60 seconds (p = .03). However, these differences between groups in non-dominant eyes were close to statistical significance (p = .07 and p = .08). Specifically, P2 was significantly lower in group 1 compared to control group (p = .01). Best corrected visual acuity was found to be significantly correlated (p ≤ .04) with total P1 (dominant eye, r = −0.51; non-dominant eye, r = −0.50), total P2 (dominant eye, r = −0.50; non-dominant eye, r = −0.50), and BCEA63 (dominant eye, r = 0.50; non-dominant eye, r = 0.40) and BCEA95 (dominant eye, r = 0.50; non-dominant eye, r = 0.40) measured at 10 seconds. Conclusions: The preliminary results of this study seem to indicate that subjects with strabismus have fixation instability regardless of the presence or absence of amblyopia.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Relationship between Corneal Morphogeometrical Properties and Biomechanical Parameters Derived from Dynamic Bidirectional Air Applanation Measurement Procedure in Keratoconus

  • Cavas Martínez, Francisco
  • Piñero, David P.
  • Velázquez, Jose S.
  • Mira, Jorge
  • Alió, Jorge L.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The morphogeometric analysis of the corneal structure has become a clinically relevant diagnostic procedure in keratoconus (KC) as well as the in vivo evaluation of the corneal biomechanical properties. However, the relationship between these two types of metrics is still not well understood. The current study investigated the relationship of corneal morphogeometry and volume with two biomechanical parameters: corneal hysteresis (CH) and corneal resistance factor (CRF), both provided by an Ocular Response Analyzer (Reichert). It included 109 eyes from 109 patients (aged between 18 and 69 years) with a diagnosis of keratoconus (KC) who underwent a complete eye examination including a comprehensive corneal topographic analysis with the Sirius system (CSO). With the topographic information obtained, a morphogeometric and volumetric analysis was performed, defining different variables of clinical use. CH and CRF were found to be correlated with these variables, but this correlation was highly influenced by corneal thickness. This suggests that the mechanical properties of KC cornea contribute only in a partial and limited manner to these biomechanical parameters, being mostly influenced by morphogeometry under normal intraocular pressure levels. This would explain the limitation of CH and CRF as diagnostic tools for the detection of incipient cases of KC.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Prophylactic effect of brimonidine to minimize the incidence of subconjunctival hemorrhage in the early postoperative period after 23G pars plana vitrectomy

  • Desco, Mari Carmen
  • Molina Martín, Julio César
  • Mataix-Boronat, Jorge
  • Pascual-Camps, Isabel
  • Palacios-Pozo, Elena
  • Barón-García, Marisa
  • Piñero, David P.
  • Navea-Tejerina, Amparo
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Background: Several studies have investigated and demonstrated the prophylactic effect of brimonidine drops in preventing subconjunctival hemorrhage in some microincisional ophthalmic surgeries, such as intravitreal injections or cataract surgery. However, there are no previous studies investigating this prophylactic effect after 23G microincisional vitreoretinal surgery. Aim: The aim of the current study was to determine whether subconjunctival hemorrhage after 23G pars plana vitrectomy (PPV) could be prevented with the use of prophylactic topical brimonidine. Methods: This was a phase III, prospective, interventional, randomized, controlled single-center clinical trial with a follow-up of 2 weeks. A total of 77 eyes (mean age: 68.4 ± 10.7 years) undergoing 23G PPV were included and randomized into two groups: group 1 including 41 patients receiving prophylactic preoperative treatment with brimonidine, and group 2 (control group) including 36 patients not receiving this prophylactic treatment. Differences in terms of number of conjunctival quadrants affected with subconjunctival hemorrhage were evaluated in each of the follow-up visits. Results: The presence of subconjunctival hemorrhage was similar in both groups the first days after surgery (p > 0.05). At the last visit (10–14 days after surgery), this condition was significantly more frequent in control group where there was a significant difference, being more frequent in the control group (7.3% vs 28.6%, p = 0.022). The number of conjunctival quadrants affected was also similar in both groups, except for the last visit in which most of the patients treated with brimonidine (92.7%) showed no bleeding compared to 71.4% in control group. No effect on the efficacy of brimonidine treatment of the presence of blood hypertension, diabetes, and antiplatelet or anticoagulant treatment was observed. Conclusion: Brimonidine seems to be a useful option to decrease subconjunctival hemorrhage after microincisional vitreoretinal surgery or improve its resolution during the first postoperative week. This finding should be mainly due to the vasoconstrictor effect of brimonidine. Trial registration: EudraCT, 2012-002895-15 (registered 19 December 2012); https://www.clinicaltrialsregister.eu/ctr-search/search?query=2012-002895-15
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparison of Standard and Total Keratometry Astigmatism Measured with three Different Technologies

  • Carreras, Humberto
  • García, Ángel G.
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To compare the keratometric and total corneal astigmatism measures provided by three different technologies as well as to assess the level of interchangeability among them. Methods: A Prospective, comparative study enrolling 94 eyes from 53 patients (age, 29-77 years) was carried out. All participants were patients with the diagnosis of cataract or patients with a transparent crystalline lens but seeking surgical presbyopia correction. A complete eye examination was performed in all eyes, including corneal analysis with three different devices: IOL-Master 700 (Carl Zeiss Meditec), Cassini (i-Optics), and Pentacam (Oculus Optikgeräte GmbH). Interchangeability of standard and total keratometric readings (equivalent keratometric readings for Pentacam) and astigmatism measures with these three systems were evaluated with the Bland-Altman analysis. Results: Significantly higher standard and total keratometric readings were obtained with the IOL-Master compared to the other two systems (p<0.001). Likewise, a significantly higher magnitude of standard and total keratometric astigmatism was obtained with the Cassini system (p<0.001). Ranges of the agreement for corneal power measurements between devices varied from 0.58 D to 1.53 D, whereas they ranged from 0.46 D to 1.37 D for standard and total astigmatism measurements. Conclusion: Corneal power and astigmatism measures obtained with IOL-Master 700, Cassini, and Pentacam systems cannot be used interchangeably. The impact of these differences on the refractive predictability achieved with different types of intraocular lenses (IOL) should be evaluated in the future in order to define which is the best corneal evaluation approach for optimizing the IOL power calculations.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Interchangeability of corneal curvature and asphericity measurements provided by three different devices

  • Piñero, David P.
  • Soto-Negro, Roberto
  • Ruiz Fortes, Pedro
  • Pérez Cambrodí, Rafael J.
  • Fukumitsu, Hideki
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
  • Pérez Cambrodí, Rafael J.|||/items/38364cfd-3cc5-456e-a7cf-5f8521b60c56
AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles. METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1y were included. In all cases, a corneal curvature analysis was performed with IOL-Master (IOLM), iDesign 2 (ID2), and Sirius systems (SIR). Differences between instruments for flattest (K1) and steepest (K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity (Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21 (P<0.001), -0.12±0.36 (P=0.046) and -0.32±0.36 D (P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33 (P<0.001), -0.08±0.43 (P=0.265) and -0.39±0.38 D (P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance (0.49 D, P=0.011; 0.55 D, P=0.386; 0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis (26.68o, 33.83o and 18.37o, P≥0.121) and for Q between SIR and ID2 (0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provide by the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Should Overnight Orthokeratology Patients Wear Their Lenses During Their Afternoon Nap?

  • Pérez-Corral, Joan
  • Cardona, Genis
  • Piñero, David P.
  • Aradilla, Yolanda
  • García, Mireia
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: The purpose of this study was to evaluate changes in visual acuity, corneal curvature, elevation, pachymetry, and objective quality of vision of experienced orthokeratology patients using their contact lenses during a simulated 30-min afternoon nap. Method: Twelve patients aged 30.8±8.3 years were recruited for the study, with a history of overnight orthokeratology of 27.4±23.0 months. Patients were instructed to close their eyes for 30 min while wearing their contact lenses or without lenses. Anterior corneal curvature, elevation, and corneal pachymetry were assessed with the Pentacam Scheimpflug System at 17 predefined corneal locations, and the HD Analyzer (Terrassa, Spain) was used to measure objective quality of vision. Measurements were conducted before eye closure (baseline), immediately after eye opening/lens removal (M1), and 30 min later (M2). Results: No statistically significant differences were found in anterior corneal curvature and elevation between baseline values and M1 or M2, with and without contact lenses. Corneal swelling at M1 was greater without contact lenses (change in central corneal thickness of 2.3%±3.1%, P=0.001) than with contact lenses (1.7%±1.3%, P<0.001). Recovery at M2 was slower when lenses were worn. A statistically significant improvement in objective quality of vision and visual acuity was found only when patients napped with their lenses. Conclusions: Even if no significant changes were found in corneal curvature and elevation, patients of overnight orthokeratology may benefit from using their contact lenses during their afternoon nap in terms of objective quality of vision and visual acuity.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization, passive and active treatment in strabismic amblyopia: a narrative review

  • Milla Baños, Myriam
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Strabismic amblyopia is characterized by a distorted spatial perception. In this condition, the neurofunctional disorder occurring during first years of life provoke several monocular and binocular anomalies such as crowding, deficits in the accommodative response, contrast sensitivity, and ocular motility abilities. The inhibition of the binocular function of the brain by the misaligned amblyopic eye induces a binocular imbalance leading to interocular suppression and the reduction or lack of stereoacuity. Passive treatments such as occlusion, optical and/or pharmacological penalization, and Bangerter foils has been demonstrated to be potentially useful treatments for strabismic amblyopia. Recent researches have proved new pharmacological options to improve and maintain visual acuity after occlusion treatment in strabismic amblyopia. Likewise, the active vision therapy, in the last years, is becoming a very relevant therapeutic option in combination with passive treatments, especially during and after monocular therapy, in the attempt of recovering the imbalanced binocular vision.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical evaluation of the effectiveness of asymmetric intracorneal ring with variable thickness and width for the management of keratoconus

  • Cuiña Sardiña, Ricardo
  • Arango, Alexandra
  • Alfonso, Jose F.
  • Álvarez de Toledo, Juan
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the short-term clinical outcomes obtained with a new model of asymmetric intracorneal ring segments (ICRS) with variable thickness and base width in keratoconus. Setting: Four ophthalmologic centers in Spain. Design: Prospective multicenter longitudinal noncomparative clinical trial. Methods: Thirty-one keratoconus eyes of 25 patients (aged 15 to 50 years) that underwent implantation of ICRS of variable thickness and base (AJL-pro+) in 4 Spanish centers were enrolled. Visual, refractive, topographic, aberrometric, and pachymetric changes were evaluated during a 3-month follow-up. Complications were also recorded. Results: Statistically significant changes after surgery were observed in uncorrected distance visual acuity (P = .002) and corrected distance visual acuity (CDVA) (P = .005), as well as in spherical equivalent (P = .006). At 3 months postoperatively, no loss of 2 or more lines of CDVA was observed, whereas 48.4% (15) of eyes gained ≥1 line. Statistically significant changes were observed in the steepest and mean keratometric values (P ≤ .047) and in the magnitude of astigmatism (P < .001) of both anterior and posterior corneal surfaces. Likewise, a change to a less prolate shape of the anterior surface was found (P = .011). Primary coma was also reduced significantly at 1 month postoperatively (P = .001, mean reduction 40.1%). No serious implant-related complications occurred during the follow-up. Conclusions: The implantation of intrastromal asymmetric ring segments of variable thickness and base width in keratoconus corneas induces a significant anterior corneal flattening, leading to refractive changes, a significant reduction of its prolate shape and irregularity, and improvement in patient CDVA.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Optical Impact of Corneal Clearance in Healthy Eyes Fitted with Scleral Contact Lenses: A Pilot Study

  • Villa, María
  • Cavas Martínez, Francisco
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This pilot study was conducted to evaluate the effect on refraction and optical quality of the increase in the corneal clearance after fitting a specific model of scleral contact lens (ScCL) in healthy subjects. A total of 15 eyes from 15 subjects were enrolled in the study, with evaluation of refraction, ocular aberrations and central corneal clearance with the same model of ScCL (ICD Toric, Paragon Vision Science, Gilbert, AZ, USA), but using 3 different sagittal heights: 4200, 4500 and 4800 µm. Mean values of corneal clearance for each ScCL fitted were 418.1 ± 112.1, 706.5 ± 120.3 and 989.9 ± 117.0 µm, respectively. Significant changes were detected in the spherical equivalent and high-order aberrations, especially coma and spherical aberration, when fitting ScCLs of increasing sagittal heights compared to the pre-fitting values. In conclusion, the increase in central corneal clearance when fitting ScCLs affects refraction, leading to a more myopic refractive error, and inducing an increase in different ocular HOAs. This should be considered when fitting ScCLs, especially multifocal designs.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

From Presbyopia to Cataracts: A Critical Review on Dysfunctional Lens Syndrome

  • Fernández, Joaquín
  • Rodríguez-Vallejo, Manuel
  • Martínez, Javier
  • Tauste Francés, Ana
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Dysfunctional lens syndrome (DLS) is a term coined to describe the natural aging changes in the crystalline lens. Different alterations in the refractive properties and transparency of the lens are produced during the development of presbyopia and cataract, such as changes in internal high order aberrations or an increase in ocular forward scattering, with a potentially significant impact on clinical measures, including visual acuity and contrast sensitivity. Objective technologies have emerged to solve the limits of current methods for the grading of the lens aging, which have been linked to the DLS term. However, there is still not a gold standard or evidence-based clinical guidelines around these new technologies despite multiple research studies have correlated their results with conventional methods such as visual acuity or the lens opacification system (LOCS), with more scientific background around the ocular scattering index (OSI) and Scheimpflug densitometry. In either case, DLS is not a new evidence-based concept that leads to new knowledge about crystalline lens aging but it is a nomenclature change of two existing terms, presbyopia and cataracts. Therefore, this term should be used with caution in the scientific peer-reviewed literature.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical outcomes of cataract surgery with implantation of a continuous transitional focus intraocular lens

  • Royo, Mariano
  • Jiménez, Ángel
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the clinical outcomes obtained after cataract or crystalline lens surgery with implantation of a new continuous transitional focus intraocular lens (IOL). Setting: San Rafael Hospital, Madrid, Spain. Design: Nonrandomized prospective case series. Methods: Uncomplicated phacoemulsification cataract surgery was performed with bilateral implantation of the continuous transitional focus IOL Precizon Presbyopic. Visual, refractive, and contrast sensitivity outcomes were evaluated during a 6-month follow-up. Likewise, the incidence of postoperative disturbing photic phenomena was recorded. Results: Sixty-two eyes of 31 patients (mean age: 61.3 years) were enrolled. Mean 6-month postoperative binocular uncorrected distance (UDVA), intermediate (UIVA), and near visual acuity (UNVA) were 0.01 ± 0.03, 0.17 ± 0.04, and 0.02 ± 0.04 logarithm of the minimum angle of resolution (logMAR), respectively. A total of 98.4% (61) and 93.5% (58) of eyes achieved 20/25 monocular UDVA and UNVA or better, respectively, whereas all eyes (100%) achieved 20/30 UIVA or better. Mean corrected visual acuity of 0.14 ± 0.05, 0.15 ± 0.06, and 0.19 ± 0.02 logMAR were obtained for the defocus levels of −1.00, −1.50, and −2.00 diopters. Mean 6-month postoperative log contrast sensitivity was 1.22 ± 0.18 and 0.75 ± 0.10 for 12 and 18 cycles per degree, respectively. A total of 9.7% (3) and 6.5% (2) of patients reported disturbing halos and glare. Conclusions: This presbyopia-correcting IOL provided a complete visual rehabilitation after cataract surgery, maintaining excellent levels of visual quality. Specifically, the IOL generated a continuous range of functional vision from distance to near, with minimal levels of photic phenomena associated.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Orthokeratology With a New Contact Lens Design in Hyperopia: A Pilot Study

  • Sánchez-García, Alicia
  • Batres-Valderas, Laura
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the preliminary clinical outcomes of a new contact lens design for orthokeratology in hyperopia. Methods: Prospective pilot study including 8 hyperopic eyes of 4 nonpresbyopic patients (24–44 years) undergoing orthokeratology with the Alexa H contact lens (Tiedra Pharmaceutical, Madrid, Spain), which is an aspheric pentacurve design. Visual, refractive, corneal topographic, and aberrometric changes were evaluated during a 1-month follow-up. Likewise, the presence of ocular surface alterations was evaluated by slit-lamp biomicroscopy during this follow-up. Results: Mean noncyclopegic sphere decreased significantly from a mean prefitting value of 2.94±0.95 D to mean values of 1.18±1.19 (P=0.01) and 0.25±0.85 D (P=0.04) at 1 week and 1 month of lens wear, respectively. Statistically significant changes were detected at 1 week of use of the lenses in keratometry (P=0.03), asphericity (Q) (P=0.01), and the Zernike term for corneal spherical aberration (SA) (P=0.01). However, no significant changes were observed in uncorrected (P=0.68) and best-corrected distance visual acuity (P=0.18). Superficial corneal staining was observed after the first night of use in only 1 patient who was resolved spontaneously. Likewise, the induction of a “toroid-like” topographic pattern leading to poor visual outcome and suboptimal correction was observed in four eyes at the beginning of the treatment. This condition was solved in all cases by reducing the lens diameter. Conclusion: The Alexa H lens seems to be useful for providing an orthokeratologic correction of hyperopia, with generation of increased negative Q and SA, and central steepening. However, fitting guides must be improved to avoid suboptimal outcomes as those related to the “toroid-like” topographic pattern defined.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization and Prediction of the Clinical Outcome of Intense Pulsed Light-Based Treatment in Dry Eye Associated to Meibomian Gland Dysfunction

  • Iradier, María T.
  • Buey, María Ángeles del
  • Peris-Martínez, Cristina
  • Cedano, Priscila
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This non-comparative prospective case series was conducted to characterize the clinical impact of intense pulsed light (IPL)-based treatment in dry eyes associated to Meibomian gland dysfunction (MGD), defining the predicting factors for a successful outcome with this therapy in a large case series. A total of 390 eyes (195 patients, range: 23–93 years) received four sessions of Optima IPL system (Lumenis, Yokneam, Israel). Significant changes were observed in tear film osmolarity in both eyes (p < 0.001) and in meibum quality (p < 0.001), with more eyes showing clear or yellow secretions after therapy. Mean change in the ocular surface disease index (OSDI) was −8.61, ranging from −27.00 to 11.00. This change was significantly correlated with the baseline value of OSDI (r = −0.489, p < 0.001). The change in osmolarity correlated significantly with the baseline osmolarity in both eyes (right r = −0.636, left r = −0.620, p < 0.001). A linear predicting model of the change in OSDI with therapy was obtained: change OSDI = 10.99 − 0.35 × OSDI − 1.03 × NIBUTRE-LE (mean non-invasive break up time of right and left eye) −2.03 × Meibum quality grade (p = 0.001; R2: 0.325). In conclusion, the improvement in symptomatology achieved with an IPL-based therapy can be predicted at baseline using a linear model considering the level of MGD and the magnitude of OSDI and NIBUT (non-invasive break-up time).
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Optical simulations of the impact of vault increase in scleral contact lenses in healthy eyes

  • Piñero, David P.
  • Tolosa, Ángel
  • Ariza-Gracia, Miguel Á.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To investigate by using computational simulations the optical impact of the change in the vault of two geometries of scleral contact lenses (SCLs). Methods: Ray-tracing simulations were performed using specialized software in three eye models with different levels of primary SA (6 mm pupil). Two different geometries of SCL were used in such simulations characterized by the conic constants of the anterior surface of the lens (K1, −0.1 and −0.3). Likewise, the fitting of the SCL was simulated for different vaults (50–250 µm). The impact on the quality of the images through the eye models was assessed by analyzing the modulation transfer function (MTF) at different spatial frequencies (10 Lp/mm, 30 Lp/mm, and 50 Lp/mm). This impact was not only simulated for a distant object, but also for intermediate and near objects (vergence demands from 0.00 to 3.00 D). All these optical simulations were performed assuming a centered SCL, but also assuming a downward vertical decentration of 0.5 mm. Results: The thinnest vault (50 µm) provided the best ocular optical quality in all three eye models for low vergence demands. For medium and high vergence demands, Lens 1 (K1 = −0.3, K2 = −0.4) resulted in a considerable improvement in optical quality in Eye 2 (C04 = −0.078 µm), while for eyes 1 (C04 = 0.408 µm) and 3 (C04 = −0.195 µm), this improvement only tended to happen for medium vergence demands. Overall, all the aberrations increased after lens fitting. Lens decentration did not cause significant variations in the results obtained with the well-centered lenses. Conclusions: Changes in the vault of a SCL have an impact on the optical quality achieved for different vergence demands independently on the level of SA of the eye in which it is fitted. The clinical relevance of such impact should be investigated further.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes

  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Camps, Vicente J.
  • Fez Saiz, Dolores de
  • Caballero, María T.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To evaluate the intrasession repeatability of anterior corneal topographic and aberrometric measurements provided by a color-LED topographer as well as their interchangeability with those provided by a Scheimpflug-based system in healthy eyes. Methods Thirty-five healthy eyes of 35 patients (age, 16–66 years) were enrolled. A complete eye examination was performed in all cases including a complete corneal analysis with the Scheimpflug-based system Pentacam (Oculus Optikgeräte) (one measurement) and the Cassini system (i-Optics) (three consecutive measurements). Intrasession repeatability of the Cassini measurements was assessed with the within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC). The Bland-Altman analysis was used to evaluate the agreement between both devices. Results Mean Sw for keratometric readings was 0.02 mm (ICC ≥ 0.992), ranging between 0.16 and 0.05 D (ICC 0.930–0.978) for anterior and total astigmatic measurements. Mean Sw for asphericity and corneal diameter were 0.06 (ICC 0.926) and 0.03 mm (IC 0.997), respectively. Aberrometric parameters showed ICCs ≥ 0.816, except for Z42 (ICC 0.741) and Z44 (ICC 0.544). When comparing devices, statistically significant differences were found for most of topographic and aberrometric data (p ≤ 0.044). Likewise, ranges of agreement between devices were clinically relevant (keratometry > 0.06 mm; total astigmatic components > 0.69 D; asphericity 0.35; second-, third-, and fourth-order Zernike terms, more than 0.20, 0.13, and 0.01 μm, respectively). Conclusions Consistent anterior corneal topographic, total corneal astigmatic, and aberrometric measurements are obtained with color-LED topography in healthy eyes, which are not interchangeable with those provided by the Scheimpflug-based topography.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Intrasession repeatability of pupil size measurements under different light levels provided by a multidiagnostic device in healthy eyes

  • Piñero, David P.
  • Fez Saiz, Dolores de
  • Cabezos, Inmaculada
  • López Navarro, Alberto
  • Caballero, María T.
  • Camps, Vicente J.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Cabezos, Inmaculada|||/items/e703f740-3941-471d-b969-8efbabd010da
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Background: The measurement of the pupillary function is an indispensable test in some eye examinations, being necessary the evaluation of the precision of instruments performing such measures. The aim of this study was to evaluate the intrasession repeatability of pupil size measurements provided by a multidiagnostic platform in a large sample of healthy eyes. Methods: This prospective study enrolled 100 healthy eyes of 100 patients, with ages ranging from 23 to 65 years old. Repeated pupil size measures under photopic (P, 220 lx), mesopic (M, 160 lx), low mesopic (L, 70 lx), and scotopic conditions (S, 1 lx) were obtained with the VX120 system (Visionix-Luneau Technologies, Chartres, France) after a complete eye exam. Likewise, pupil size was also measured once in the fellow eye in a total of 75 eyes. The level of intrasession variability as well as differences between fellow eyes were evaluated. Results: Most of differences between repeated measures did not exceed 0.5 mm (82% of S and 100% of P below this value). No significant differences between these repeated measures were found for S (p = 0.099) and L (p = 0.751). However, statistically significant differences were found between repeated measures for M (p = 0.002) and P (p = 0.003). The analysis of clinical relevance of differences between pairs (Passing-Bablok) only confirmed the clinical relevance of differences between the first and second repeated measurement of M. Concerning the comparative analysis between fellow eyes, no statistically significant differences in pupil size were found between right and left eyes in any light condition evaluated (p ≥ 0.227). Conclusions: The VX120 system can provide consistent measurements of pupil size under scotopic, low mesopic and photopic conditions, with a relative limitation under mesopic conditions.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical outcomes with an aspheric monofocal and a new enhanced monofocal intraocular lens with modified optical profile

  • Goslings, Oege
  • Veraart, Henk
  • van de Laar-Muskens, Janny
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose This study aimed to evaluate and compare the clinical outcomes obtained after cataract surgery with an aspheric monofocal intraocular lens (IOL) and an enhanced IOL with a modified optical profile. Methods Randomised clinical trial enrolling 70 patients (age, 52–87 years) undergoing cataract surgery. Two groups were created according to the type of IOL implanted: Vivinex iSert from Hoya Surgical Optics (Vivinex group, 35 patients) and Tecnis Eyhance ICB00 from Johnson & Johnson Vision (Eyhance group, 35 patients). Uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity (DCIVA), refraction, and self-perceived visual function (Catquest-9SF) were evaluated during a 3-month follow-up. Results No significant differences were found between IOL groups in UDVA and CDVA (p ≥ 0.093). In contrast, monocular and binocular UIVA and DCIVA were significantly better in the Eyhance group at 1 (p ≤ 0.015) and 3 months postoperatively (p ≤ 0.002). Postoperative DCIVA 20/25 or better was obtained in 71.4% and 20.0% of patients in Eyhance and Vivinex groups, respectively. Differences in postoperative Rasch calibrated Catquest scores between Eyhance and Vivinex groups did not reach statistical significance (p ≥ 0.102). However, significant correlations were only found between the change in UIVA and Catquest scores (0.364 ≤ r ≤ 0.444, p ≤ 0.041) in the Eyhance group. Conclusions The modified monofocal IOL evaluated provides better intermediate visual function in comparison with a standard aspheric monofocal IOL, but the impact of this benefit on the self-perceived level of vision achieved after surgery according to the patient seemed to be limited.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

The Potential of Virtual Reality for Inducing Neuroplasticity in Children with Amblyopia

  • Coco-Martin, María Begoña
  • Piñero, David P.
  • Leal-Vega, Luis
  • Hernández Rodríguez, Carlos Javier
  • Adiego Rodríguez, Joaquín
  • Molina-Martín, Ainhoa
  • Fez Saiz, Dolores de
  • Arenillas, Juan F.
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
In recent years, virtual reality (VR) has emerged as a new safe and effective tool for neurorehabilitation of different childhood and adulthood conditions. VR-based therapies can induce cortical reorganization and promote the activation of different neuronal connections over a wide range of ages, leading to contrasted improvements in motor and functional skills. The use of VR for the visual rehabilitation in amblyopia has been investigated in the last years, with the potential of using serious games combining perceptual learning and dichoptic stimulation. This combination of technologies allows the clinician to measure, treat, and control changes in interocular suppression, which is one of the factors leading to cortical alterations in amblyopia. Several clinical researches on this issue have been conducted, showing the potential of promoting visual acuity, contrast sensitivity, and stereopsis improvement. Indeed, several systems have been evaluated for amblyopia treatment including the use of different commercially available types of head mounted displays (HMDs). These HMDs are mostly well tolerated by patients during short exposures and do not cause significant long-term side effects, although their use has been occasionally associated with some visual discomfort and other complications in certain types of subjects. More studies are needed to confirm these promising therapies in controlled randomized clinical trials, with special emphasis on the definition of the most adequate planning for obtaining an effective recovery of the visual and binocular function.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Preliminary Characterization of Predictive Factors of the Visual Change after Epi-On and Epi-Off Corneal Collagen Crosslinking Techniques

  • Hamida Abdelkader, Sidi Mohamed
  • Fernández, Joaquín
  • Sebastián, Javier
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. To investigate the potential predictive factors of the visual change achieved with accelerated epi-on and epi-off corneal collagen crosslinking (CXL) in keratoconus. Methods. This retrospective comparative study analyzed 67 eyes treated with an accelerated epithelium-on (epi-on group) and epithelium-off (epi-off group) CXL. The clinical outcomes were evaluated and compared during a 1-year follow-up. Likewise, the relationship of the change achieved with both CXL techniques in the corrected distance visual acuity (CDVA) with different preoperative data was investigated. Results. The mean CDVA change at 3 months postoperatively was −0.04 ± 0.19 and −0.07 ± 0.25 in the epi-on and epi-off groups, respectively (p = 0.809). In the epi-on group, this change was significantly correlated with the preoperative apical (r = −0.375, p = 0.045) and central corneal thickness (r = −0.402, p = 0.031). In the epi-off group, the CDVA change was significantly correlated with not only the preoperative apical (r = 0.402, p = 0.028) and central corneal thickness (r = 0.367, p = 0.046) but also with some topometric and aberrometric indices (r ≤ −0.374, p ≤ 0.042). Furthermore, the change in CDVA in the epi-on group could be predicted from age, preoperative refractive astigmatism J45 component, anterior corneal asphericity, and posterior corneal high order aberration root mean square (p = 0.002, R2 = 0.503). In the epi-off group, the CDVA change could be predicted from the preoperative minimum corneal thickness and magnitude of the vertical anterior corneal primary coma component (p = 0.001, R2 = 0.446). Conclusions. Clearly, different predictive factors of the visual change induced with the accelerated epi-on and epi-off CXL techniques are present, suggesting a different mechanism of action for stiffening the cornea and inducing changes in this structure.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparative analysis of anterior corneal curvature and astigmatism measurements obtained with three different devices

  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Caballero, María T.
  • Fez Saiz, Dolores de
  • Camps, Vicente J.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Background: The objective of this study was to compare the central corneal curvature and astigmatism measurements obtained with three different systems in healthy eyes and to assess the level of interchangeability between them. Methods: This was a comparative study examining 30 healthy eyes of 30 patients (age 15–53 years). A complete eye examination was performed in all cases including analysis of anterior corneal curvature and astigmatism with three devices: the colour‐LED topography system Cassini (i‐Optics) (CAS), the Scheimpflug‐based system Pentacam (Oculus Optikgeräte) (PTC) and the optical biometer IOL‐Master 500 (Carl Zeiss Meditec) (IOLM). Differences between devices in terms of curvature in the flattest (flat K) and steepest meridians (steep K) as well as in the magnitude (AST) and power vector components of astigmatism (J0 and J45) were evaluated. The interchangeability between devices was evaluated with the Bland–Altman method. Results: Statistically significant differences between devices were found in steep K and flat K (p < 0.001). No statistically significant differences between devices were found in AST (p = 0.057) and J0 power vector (p = 0.185). However, differences between devices in J45 did reach statistical significance (p = 0.039). Ranges of agreement for curvature measures ranged from 0.123 (flat K, CAS‐PTC) to 0.165 mm (steep K, CAS‐PTC). Ranges for the magnitude of astigmatism were 0.868, 1.059 and 0.739 D in CAS‐IOLM, PTC‐IOLM and CAS‐PTC comparisons, respectively. For J0 and J45, ranges of agreement were below 0.522 D. Conclusions: Measurements of central corneal curvature and astigmatism obtained with the three devices evaluated cannot be used interchangeably.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization and prediction of the clinical result with a specific model of mini-scleral contact lens in corneas with keratoconus

  • Hamida Abdelkader, Sidi Mohamed
  • García-Barchín, Marta
  • Ruiz Fortes, Pedro
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Background: To investigate which factors are correlated with the visual improvement achieved with a specific model of scleral contact lens (SCL) in keratoconus (KC) eyes and to define a model to predict such improvement according to the pre-fitting data. In addition, the changes occurred with the fitting of a specific model of SCL during a period of 3 months in corneas with KC have been investigated. Methods: Longitudinal retrospective study including 30 eyes of 18 patients (age, 14–65 years) with KC fitted with the SCL ICD16.50 (Paragon Vision Sciences). Visual, refractive, corneal tomographic and ocular aberrometric changes were evaluated during a 3-month follow-up. Likewise, the characterization of the post-lens meniscus was performed by optical coherence tomography (OCT) with the measurement of central, nasal and temporal vaults. Results: The visual acuity increased significantly from a mean pre-fitting value with spectacles of 0.23 ± 0.07 logarithm of minimal angle of resolution (logMAR) to a mean value of 0.10 ± 0.04 logMAR after 1 month of SCL wear (P < 0.001). An improvement of 1 or more lines of visual acuity with the SCL occurred in 62.1% of the eyes. A significant decrease in central, nasal, and temporal vault was observed after 1 month of SCL wear (P ≤ 0.046). Likewise, there was a significant difference between nasal and temporal vaults during the first month of SCL use (P = 0.008). Furthermore, a significant reduction of ocular high order (P = 0.028) and primary coma root mean square (P = 0.018) was found with the SCL. A predicting linear equation of the change in visual acuity achievable with the SCL was obtained (P < 0.001, R2 = 0.878) considering the pre-fitting spectacle corrected distance visual acuity, and the power and sagittal lens of SCL. Conclusions: The scleral contact lens evaluated provides an efficacious visual rehabilitation in KC due to the improvement of visual acuity and the correction of low and high-order ocular aberrations. This visual acuity improvement can be predicted from some pre-fitting variables.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Potential of video games for the promotion of neuroadaptation to multifocal intraocular lenses: a narrative review

  • Coco-Martin, María Begoña
  • Valenzuela, Pedro L.
  • Maldonado, Miguel J.
  • Santos-Lozano, Alejandro
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Multifocal intraocular lenses (IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients’ dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocal IOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Changes in the Hyperreflective Bands of Outer Retinal Layers after Idiopathic Epiretinal Membrane Surgical Removal

  • Molina Martín, Julio César
  • Piñero, David P.
  • García Conca, Victor
  • Desco, Mari Carmen
  • Mataix-Boronat, Jorge
  • Balboa Alonso, María
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: The purpose of this study was to describe the relationship between the outer retinal hyperreflective bands and visual acuity recovery after idiopathic epiretinal macular membrane (ERM) surgical removal. Methods: A prospective longitudinal non-comparative study was conducted that included a total of 68 patients with idiopathic ERM, who underwent consecutive 23 G pars plana vitrectomy (PPV) at San Juan University Hospital (Alicante, Spain) from January 2019 to January 2021. All patients underwent a complete preoperative standard ophthalmic examination, including measurement of best corrected visual acuity (BCVA) and spectral-domain optical coherence tomography (SD-OCT) examination. This protocol was repeated at 1 and 3 months after surgery. Results: Mean preoperative decimal BCVA was 0.30 ± 0.13 and disruption of the first, second, third and fourth outer retinal hyperreflective bands was observed by SD-OCT in 9 (27.9%), 27 (39.7%), 33 (48.5%) and 17 patients (25%), respectively. BCVA improved after ERM peeling at 1 and 3 months in all patients, regardless of the presence of disruption in any hyperreflective band. Significantly larger improvement of BCVA was found at 3 months after surgery in patients not showing disruption of hyperreflective bands 1 and 4 (p = 0.048 and 0.001, respectively). Conclusions: The integrity of the outer retinal hyperreflective bands by SD-OCT in patients with idiopathic ERM is a valuable tool to determine the visual prognosis of the surgical treatment of this condition. A successful recovery of hyperreflective bands 1 and 4 with ERM surgery may be a potential biomarker of the visual improvement achieved due to their important anatomical relation with cone photoreceptors at the foveal level.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Differences in the Long-term Progression Course of Two Cases of Pellucid-like Keratoconus: Are they the Same Condition with Different Phenotypic Presentation?

  • Martínez-Abad, Antonio
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
We report the long-term follow-up of two cases of untreated corneal ectasia presenting a crab claw-like sagittal and tangential topographic pattern at baseline, but without peripheral thinning. Currently, according to clinical examination, these two cases are diagnosed as pellucid-like keratoconus (PLK). The first case was a 58-year-old male who developed a true pellucid marginal degeneration (PMD) in one eye and with a nonprogressive PLK in the other eye. The second case presented was a 19-year-old male without clinical signs of ectasia at baseline that progressed to PLK with evident changes in topographic and pachymetric maps but maintaining the point of minimum corneal thickness (MCT) in the central area. The presence of two different conditions in the same patient (case 1) and the progression from inferosuperior asymmetry to the development of a crab claw-pattern (case 2) suggest that PMD, PLK, and keratoconus may be different phenotypic presentations of the same pathophysiological condition.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Impact of Alzheimer’s Disease in Ocular Motility and Visual Perception: A Narrative Review

  • Almario, Gemma
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: Alzheimer’s disease (AD) is a neurodegenerative disease generating a progressive neuronal loss as well as cognitive deficiencies. This disease can be accompanied by ocular manifestations, including alterations in ocular motility and visual perception. The aim of the current review article was to collect all the information about these alterations and to analyze if there is scientific evidence supporting the potential use of these changes as biomarkers of the disease. Methods: A bibliographic search was performed using two different databases, Pubmed and Google Scholar, as well as a search of material in non-peer reviewed journals about Alzheimer’s and Neurology. A total of 227 articles were found in the initial search, but only 76 were included considering their relevance according to the purpose of the review. Results: This narrative review describes the findings obtained in this area to this date, confirming that deficiencies in saccades is the most common condition among AD patients. Furthermore, other visual alterations have also been reported in these patients, including a compromise of visual acuity and contrast sensitivity, fluctuations of colour vision, stereopsis impairment and visual field losses. Likewise, other complex visuo-spatial and visuo-perceptual impairments can be present. More studies are still needed to understand better what type of changes occurs in ocular alignment, binocularity, and fixation pattern in AD patients. Conclusions: AD is associated to visual perception and ocular motility alterations. All the scientific information found in this review should be considered as a guide for designing future studies and to define adequate clinical protocols for the visual evaluation of patients with AD, considering the cognitive limitations that are normally present in this type of patients.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Binocular Vision in Patients with Multiple Sclerosis

  • Gil-Casas, Amparo
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: Oculomotor disorders have been reported in multiple sclerosis (MS) in up to 80% of cases. There have been studies evaluating binocular vision in several neurological diseases, but not in MS. Considering that a high percentage of eye-movement anomalies have been reported, the aim of this study was to analyze binocular vision in these subjects. Methods: A total of 59 participants with MS — 21 with monocular optic neuritis, eleven with binocular optic neuritis, and 27 without optic neuritis — and 26 age-matched controls were enrolled. Binocular vision was analyzed using near point of convergence (NPC), positive and negative fusional vergence for far and near distance, measurement of heterophoria at both distances with cover and modified Thorington tests, and random-dot stereoscopy. Results: The percentage of subjects with abnormal NPC values was highest in the MS group, followed by the MSONm (MS with optic neuritis in one eye), MSONb (MS with optic neuritis in both eyes), and control groups. MS patients showed an esophoric trend at near distance. Positive fusional vergence showed no significant differences between control and MS groups, but higher variability in recovery was found in MS groups. Negative fusional vergence at near distance showed significant differences between the control group and the two MS groups, with optic neuritis for both break-point and recovery values. A high percentage of patients with MS had alterations on stereopsis. Conclusion: Alterations in binocular vision were present in MS, with divergence at near distance and stereopsis the most affected parameters. Likewise, MS patients with optic neuritis showed worse binocular vision.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Binocular, Accommodative and Oculomotor Alterations In Multiple Sclerosis: A Review

  • Gil-Casas, Amparo
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Multiple sclerosis (MS) is an acquired demyelinating and inflammatory neurodegenerative disease affecting the central nervous system (CNS). Clinical and subclinical ocular disturbances occur in almost all patients with MS. The objective of this narrative review was to collect and summarize the available scientific information on oculomotor, accommodative and binocular alterations that have been reported in MS. A systematic search strategy with the following descriptors was carried out: multiple sclerosis, ocular motility disorders, internuclear ophthalmoplegia, nystagmus, vergences, fixation, pupil reflex, accommodation and stereopsis. According to the search, some oculomotor alterations were found to be commonly reported in MS, such as alterations in saccades and nystagmus. In contrast, accommodative, vergence and stereopsis alterations have not been comprehensively studied despite their relevance, with only minimal evidence showing a potential negative impact of the disease on these aspects. In conclusion, oculomotor impairment is a common component of disability in MS patients and should be considered when managing this type of patients. More research is still needed to know the real impact of this disease on binocular vision and accommodation.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Differences in Contrast Reproduction between Electronic Devices for Visual Assessment: Clinical Implications

  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Coco-Martin, María Begoña
  • Leal-Vega, Luis
  • Fez Saiz, Dolores de
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The easy access to electronic devices for users has resulted in the development of a vast range of programs and applications for visual evaluation and diagnosis that can be downloaded to any device. Some of them are based on tasks and stimuli that depend on luminance. The aim of the present study was to evaluate differences in luminance reproduction between electronic devices and their implications for contrast reproduction. A total of 20 Galaxy Tab A devices with 8-bit graphics processing units were evaluated. Characterization of every screen was performed obtaining the response curve for the achromatic stimulus. Mean, maximum and minimum luminance, standard deviation and coefficient of variation were obtained to assess differences between devices. Variation of luminance with increasing digital level was observed in all devices following a gamma distribution. Comparison between devices for mean results showed that some of them differed by as much as 45 cd/m2. The coefficient of variation varied from ~5 to 9%. Mean percentage of differences in luminance between devices reached 30%. In conclusion, differences in luminance reproduction between devices were present, even considering devices from the same manufacturing batch. It cannot be assumed that the characterization of one device can be extrapolated to other devices. Every device used for research purposes should be individually characterized to ensure the correct reproduction. For clinical purposes, limitations should be considered by visual specialists.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of a new nomogram for Ferrara ring segment implantation in keratoconus

  • Fernández, Joaquín
  • Peris-Martínez, Cristina
  • Pérez-Rueda, Antonio
  • Hamida Abdelkader, Sidi Mohamed
  • Roig-Revert, Maria José
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
AIM: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data. METHODS: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asphericity and astigmatism or the discrepancy among astigmatism and coma orientations. Visual, refractive, corneal topographic, aberrometric, and pachymetric changes after surgery were evaluated during a 3-month follow-up. RESULTS: The implants induced a significant refractive change as well as an improvement in uncorrected (UDVA) and corrected distance visual acuity (CDVA; P<0.001). Postoperative CDVA of 0.10 logMAR or better was achieved in 28.4% and 46.5% of eyes, respectively. Two eyes (2.3%) lost two or more lines of CDVA whereas a total of 53.5% of eyes gained lines of CDVA. A significant central anterior and posterior corneal flattening was induced (P≤0.003), with a significant reduction of anterior (P<0.001) and posterior corneal astigmatisms (P=0.048), and a change in anterior asphericity (P<0.001). Total primary coma (6 mm pupil) change was also statistically significant (preoperative 3.66±3.04 ?m vs postoperative 2.33±2.26 ?m, P<0.001). No significant differences were found in the effect of ring segments between cases implanted using the mechanical and femtosecond techniques (P≥0.101). CONCLUSION: The implantation of Ferrara rings based on the nomogram evaluated is safe and effective for promoting a visual rehabilitation in keratoconus, with a relevant control of primary coma aberration.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Objective and Subjective Evaluation of Saccadic Eye Movements in Healthy Children and Children with Neurodevelopmental Disorders: A Pilot Study

  • Bilbao, Carmen
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The objective of this study was to characterize saccades in children with neurodevelopmental disorders (NDDG, 17 children, age: 7–12 years) and compare them with a control group (CG, 15 children, age: 7–12 years), comparing the outcomes obtained with a subjective score system (Northeastern State University College of Optometry’s Oculomotor test, NSUCO) with the objective analysis obtained through a commercially available Eye Tracker (Tobii Eye X, Tobii, Stockholm, Sweden) and a specialized software analysis (Thomson Software Solutions, Welham Green, UK). Children from the NDDG obtained significantly lower NSUCO scores (p < 0.001) compared with CG. Concerning eye tracking analyses, we found a significantly higher number of hypometric saccades in NDGG (p ≤ 0.044). Likewise, we found a significantly higher percentage of regressions in the NDDG for a time interval of presentation of stimuli of 1 s (p = 0.012). Significant correlations were found between different NSUCO scores and percentage of regressions, number of saccades completed and number of hypometric saccades. The presence of hypometric saccades and regressions seems to be a differential characteristic sign of children with neurodevelopmental disorders that can be detected using an objective eye tracking analysis, but also using the subjective test NSUCO that can be easily implemented in all clinical settings.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Efficacy and safety of treatment of hyposecretory dry eye with platelet‐rich plasma

  • García‐Conca, Víctor
  • Abad‐Collado, Marta
  • Hueso‐Abancens, Jose R.
  • Mengual‐Verdú, Encarna
  • Piñero, David P.
  • Aguirre‐Balsalobre, Fernando
  • Molina, Julio C.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Objective: To evaluate and compare the symptomatology and clinical findings in hyposecretory dry eye of the treatment with platelet‐rich plasma (PRP) and artificial tears of sodium hyaluronate (SH). Methods: Blind single‐centre prospective comparative randomized study including 83 patients with hyposecretory dry eye and mean age of 64.0 years. Two groups were differentiated depending on the treatment applied: 44 patients treated with PRP (PRP group), and 39 patients treated with artificial tears of SH (SH group). Changes in Schimer test, tear osmolarity, corneal and conjunctival staining, tear film break‐up time (TF‐BUT), conjunctival hyperaemia, dry eye‐related symptoms with the Ocular Surface Disease Index questionnaire, and caliciform cell density were evaluated during 30 days of treatment. Results: Significantly larger reduction in symptomatology (p < 0.001), visual improvement (p < 0.001), reduction in hyperaemia (p < 0.001), and corneal and conjunctival staining (p < 0.001), increment of Schirmer test outcome (p ≤ 0.005), and reduction of osmolarity were found in the PRP group in both eyes compared to SH group at 15 and 30 days of treatment. Likewise, a significantly higher increment of caliciform cell density (p < 0.001) was found in the PRP group. Strong and statistically significant correlations were found in the PRP group of the change achieved in visual acuity, hyperaemia, osmolarity, and conjunctival and corneal staining with the baseline values of these variables (p < 0.001). Conclusion: PRP treatment in hyposecretory dry eye induces a more significant positive effect over symptomatology and different dry eye signs than SH, especially in moderate and severe cases.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Characterization of the geometric properties of the sclero-conjunctival structure: a review

  • Bataille, Laurent
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
To revise the peer-reviewed literature on geometric properties of the scleral-conjunctival structure in order to define their clinical relevance and the potential relationship between their changes and myopia development or progression. A bibliographic search focused on the study of the geometry of conjunctiva and/or sclera as well as those studies evaluating the relationship between geometric changes in the scleral-conjunctival structure and myopia was carried out. Several studies have been performed with different diagnostic technologies, including optical coherence tomography, profilometry and Scheimpflug imaging, to detect geometric changes of the scleral-conjunctival tissue in different physiological conditions of the eye, after use of contact lenses and in different ocular pathologies. Likewise, these technologies have been shown to be a valuable clinical tool to optimize scleral contact lens fitting. Future studies should investigate new potential clinical applications of such technologies, including the evaluation of anterior scleral changes related to myopia, as well as to define standardized clinical standard operating procedures for obtaining accurate and reproducible clinical measurement of the scleral-conjunctival morphology.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Assessment of Pattern and Shape Symmetry of Bilateral Normal Corneas by Scheimpflug Technology

  • Cavas Martínez, Francisco
  • Piñero, David P.
  • Fernández-Pacheco, Daniel G.
  • Mira, Jorge
  • Cañavate, Francisco J.F.
  • Alió, Jorge L.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: The aim of this study was to assess bilateral symmetry in normal fellow eyes by using optical and geometric morphometric parameters. Methods: All participants underwent complete biocular examinations. Scheimpflug tomography data from 66 eyes of 33 patients were registered. The interocular symmetry was based on five patterns: morphogeometric symmetry, axial symmetry at the corneal vertex, angular-spatial symmetry, direct symmetry (equal octants), and enantiomorphism (mirror octants). Results: No statistically significant differences were found between right and left eyes in corneal morphogeometric (p ≥ 0.488) and aberrometric parameters (p ≥ 0.102). Likewise, no statistically significant differences were found in any of the axial symmetry parameters analyzed (p ≥ 0.229), except in the surface rotation angle beta (p = 0.102) and translation coordinates X0 and Y0 (p < 0.001) for the anterior corneal surface, and the rotation angle gamma (p < 0.001) for the posterior surface. Similarly, no statistically significant differences were identified for direct symmetry (p ≥ 0.20) and enantiomorphism (p ≥ 0.75), except for some elevation data in the posterior surface (p < 0.01). Conclusions: The level of symmetry of both corneas of a healthy individual is high, with only some level of disparity between fellow corneas in rotation and translation references. Abnormalities in this pattern of interocular asymmetry may be useful as a diagnostic tool.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Short- and mid-term changes in CORVIS ST parameters in successful, adult orthokeratology patients

  • Pérez-Corral, Joan
  • Cardona, Genis
  • Piñero, David P.
  • Barroso, David
  • Armadans, Laura
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Clinical relevance: The changes in various biomechanical and tomographic characteristics of the cornea associated with orthokeratology may allow us to identify potential mid- and long-term structural alterations, resulting in a better understanding of the governing mechanisms of this procedure and in its optimisation. Background: The study aimed at describing short and mid-term changes in CORVIS ST® parameters and indices in orthokeratology (ortho-k), and their diurnal variations. Methods: A prospective observational study was designed in which several CORVIS ST® parameters of 75 new adult participants successfully fitted with overnight ortho-k Seefree® (Conóptica – Hecht Contactlinsen) contact lenses were explored. Measurements were conducted in baseline (BL) conditions and in the morning and evening at the one-night (1 NM/1NT), one-week (1WM/1 WT) and 3-month (3 MM/3MT) follow-up visits. Results: Statistically significant differences were found in DARatio_2 mm, IntRad, ARTh, CBI and TBI following overnight ortho-k, when compared with BL values, with most values reaching stability at 1WM or reverting to BL values at 3 MM. The ARTh and CBI parameters showed some of the most significant temporal variations (both p < 0.001), probably reflecting the encountered differences in central corneal thickness between BL and 1WM (p = 0.010) and between BL and 3 MM (p = 0.016). In general, corneal rigidity was higher in the morning at all follow-up visits, and decreased during the day. No statistically significant changes in adjusted intraocular pressure values were found. Conclusion: Ortho-k in adults may be considered a safe procedure in terms of short and mid-term changes in CORVIS ST® parameters. The observed alterations in most of the parameters provided by the Corvis ST® probably responded to the well-described changes in corneal pachymetry and tomography, rather than to actual alterations in corneal rigidity.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Surgical Treatment of Idiopathic Macular Hole Using Different Types of Tamponades and Different Postoperative Positioning Regimens

  • Veith, Miroslav
  • Vránová, Jana
  • Němčanský, Jan
  • Studnička, Jan
  • Penčák, Martin
  • Straňák, Zbyněk
  • Mojzis, Peter
  • Studeny, Pavel
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. To compare the effect of different types of intraocular tamponade and different types of postoperative positioning on the closure of idiopathic macular hole (IMH). Methods. Prospective randomized clinical trial enrolling 104 eyes of 100 patients (age, 57–87 years) undergoing MH surgery. All patients were operated on by an experienced surgeon using 25-gauge pars plana vitrectomy (PPV) and internal limiting membrane (ILM) peeling. Patients were randomized according to the type of intraocular tamponade and postoperative positioning into the following four groups: SF6 + nonsupine reading position (n = 26) (group 1), air + nonsupine reading position (n = 25) (group 2), air + prone position (n = 26) (group 3), or SF6 + prone position (n = 27) (group 4). The follow-up period was 6 months. Results. MH closure was achieved in 87 eyes (83.7 %) in the overall sample after the first surgery, with closure rates of 100%, 56%, 84.6%, and 92.6% in groups 1, 2, 3, and 4, respectively. The group 2 was significantly less successful compared to the other three groups (p < 0.05). MH of sizes ≤400 µm was closed in 97.2% of cases after the first surgery, with no significant differences between groups (p = 0.219). MH with sizes over 400 µm was closed in 70.9% of cases after the first surgery, with both groups with air tamponade being significantly less successful than group 1. The nonsupine reading position was subjected to a better subjective evaluation in terms of postoperative comfort and quality of sleep, with no differences between air and SF6 tamponade tolerance. Conclusion. PPV with ILM peeling, intraocular tamponade, and positioning remains the basic surgical approach in the treatment of IMH. For MH ≤ 400 µm, a high closure rate can be achieved by combining air tamponade and nonsupine reading position. For macular holes >400 µm, the greatest anatomical success can be achieved by using the SF6 tamponade in combination with the nonsupine reading position.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses

  • Gimenez-Sanchis, Inma
  • Palacios-Carmen, Beatriz
  • García-Garrigós, Angel
  • Cantó-Vañó, Javier
  • Pérez-Ortega, Antonio J.
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: The aim of this study was to show the potential applicability of optical coherence tomography angiography (OCTA) for the evaluation of the peripheral fitting of fully scleral contact lenses. Methods: A pilot study was proposed fitting three different scleral contact lenses (Irregular Corneal Design [ICD]) with different sagittal heights (4200, 4800, and 5600 mm) in a healthy volunteer of 27 years old. We evaluated by means of optical coherence tomography (OCT, DRI Triton) the apical clearance achieved with each of the three lenses fitted. The impact over scleral flow was assessed with the OCTA module of the same device. Results: The apical clearance was 310, 901, and 1680 µm with the scleral lenses of sagittal heights 4200, 4800, and 5600 µm, respectively. With OCTA, we evaluated the impact of the lens bearing on the conjunctival vascular flow, observing an area of vascular interruption of 0, 25, and 75% with the lenses of 4200, 4800, and 5600 µm of sagittal heights, respectively. The vascular interruption was induced in the perilimbar area, suggesting the need of readjusting the limbal clearance zone of the lens. Conclusion: Fully scleral contact lens fitting may be optimized with the use of OCTA, allowing the practitioner to perform the fitting with better control of the peripheral bearing of the lens on the conjunctival tissue, assessing the impact on vascular structures. This potential use of OCTA must be investigated further in future studies including large samples of eyes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Stimuli Characteristics and Psychophysical Requirements for Visual Training in Amblyopia: A Narrative Review

  • Hernández Rodríguez, Carlos Javier
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Morales-Quezada, León
  • Fez Saiz, Dolores de
  • Leal-Vega, Luis
  • Arenillas, Juan F.
  • Coco-Martin, María Begoña
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Active vision therapy using perceptual learning and/or dichoptic or binocular environments has shown its potential effectiveness in amblyopia, but some doubts remain about the type of stimuli and the mode and sequence of presentation that should be used. A search was performed in PubMed, obtaining 143 articles with information related to the stimuli used in amblyopia rehabilitation, as well as to the neural mechanisms implied in such therapeutic process. Visual deficits in amblyopia and their neural mechanisms associated are revised, including visual acuity loss, contrast sensitivity reduction and stereopsis impairment. Likewise, the most appropriate stimuli according to the literature that should be used for an efficient rehabilitation of the amblyopic eye are described in detail, including optotypes, Gabor’s patches, random-dot stimuli and Vernier’s stimuli. Finally, the properties of these stimuli that can be modified during the visual training are discussed, as well as the psychophysical method of their presentation and the type of environment used (perceptual learning, dichoptic stimulation or virtual reality). Vision therapy using all these revised concepts can be an effective option for treating amblyopia or accelerating the treatment period when combining with patching. It is essential to adapt the stimuli to the patient’s individual features in both monocular and binocular training.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Uncontrolled experimentation is not an option for open minds: Ethical research is the answer, La experimentación incontrolada no es una opción para mentes abiertas: La investigación ética es la respuesta

  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Short-Term Effect of Wearing of Extended Depth-of-Focus Contact Lenses in Myopic Children: A Pilot Study

  • Corpus, Gema
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This pseudo-experimental, prospective, and longitudinal pilot study was conducted to characterize the optical and visual changes occurring in the short-term wear of a hydrophilic contact lens (CL) based on extended focus technology (EDOF). A total of 30 eyes of 15 children (age, 6–16 years) were fitted with the EDOF CL Mylo (Mark’ennovy Care SL), performing an exhaustive follow-up for one month evaluating changes in visual acuity (VA), accommodation, binocularity, ocular aberrometry, visual quality, pupillometry, keratometry and biometry. Far and near VA with the CL improved progressively (p < 0.001), obtaining mean final binocular values of −0.08 ± 0.01 and −0.07 ± 0.01 LogMAR, respectively. There was a mean reduction in the accommodative LAG of 0.30 D (p < 0.001), without associated alterations in the magnitude of the phoria and fusional vergences (p ≥ 0.066). A controlled but statistically significant increase (p ≤ 0.005) of ocular high order aberration (HOA) root mean square (RMS), primary coma RMS, primary spherical aberration Zernike term and secondary astigmatism RMS was found with the CL wear. In conclusion, the EDOF CL evaluated provides adequate visual acuity and quality, with associated increased of several HOAs and a trend to reduction in the accommodative LAG that should be confirmed in future studies.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical Evaluation of a New Approach for IOL Power Calculation in Keratoconus

  • Camps, Vicente J.
  • Fikry, Ramy R.
  • Mateo Pérez, Verónica
  • Labib, Fady E.
  • Caravaca Arens, Esteban
  • Caballero, María T.
  • Piñero, David P.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To obtain an expression of the adjusted IOL power (PIOLadj) in keratoconus eyes associated with minimal errors in IOL power calculation. Materials and methods: This retrospective study included a total of 25 eyes of 25 patients with ages ranging from 20 years to 76 years. The following IOLs were implanted: Acrysof IQ Toric, Acrysof SA60AT in 9 eyes, Sensar in 3 eyes, Tecnis 1 in 4 eyes, and Tecnis Toric in 2 eyes. The PIOLadj is based on Gauss equations, using adjusted keratometric index (nkadj) specific to keratoconus eyes. From this nkadj, an adjusted keratometric corneal power is calculated (Pkadj). The PIOLadj calculation was performed after estimating the effective lens position (ELP) using a mathematical expression obtained by multiple regression analysis (named ELPadj). Comparison between the PIOLadj and the real intraocular power implanted in each patient (PIOLreal) was carried out. Results: No significant differences between PIOLreal and PIOLadj were found. However, differences could be clinically relevant up to of 2.54 D as PIOLreal increases. But, in the range of PIOLreal between 0 and 20 D, differences were lower than 1.5 D, being most of them below 1 D. Conclusion: A new formula of IOL power calculation (PIOLadj) based on the use of an adjusted keratometric power (Pkadj) that considers a variable keratometric index due to the influence of the posterior corneal surface (nkadj) and adjusted effective lens position (ELPadj) is useful for estimating IOL power in low-to-moderate keratoconus, with more limitation in the most advanced keratoconus.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Visual and Refractive Outcomes with a New Topography-integrated Wavefront-guided Lasik Procedure

  • Uceda Montañés, Antonio
  • Rogers, Michael
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) using a new approach for the calculation of the ablation profile based on wavefront vertexing from pupil plane to corneal. Methods: One hundred eyes of 50 patients (age, 21–41 years) with low and moderate myopia were enrolled in this prospective case series. All of them underwent topography-integrated wavefront-guided (TI-WFG) LASIK using the STAR S4IR excimer laser platform (Johnson & Johnson Vision). Visual, refractive, ocular aberrometric, ocular scattering index (OSI) and patient satisfaction outcomes were evaluated after a 90-day follow-up period. Astigmatic changes were evaluated by vector analysis. Results: A significant reduction in sphere and cylinder (p < .001) was observed, with a significant improvement in uncorrected (UDVA) and corrected distance visual acuity (CDVA) (p < .001). Postoperative spherical equivalent was within ±0.50 and ±1.00 D in 91.1% (82/90) and 98.9% (89/90) of eyes, respectively. UDVA was 20/20 or better in 98.9% (89/90) of eyes. A total of 50.0% (45/90) of eyes gained 1 line of CDVA. Mean postoperative astigmatic correction index and angle of error were 1.01 ± 0.56 and 0.17 ± 0.18º. Postoperative high-order aberrometric coefficients were below 0.50 μm in 92.2% (83/90) of eyes. Mean postoperative OSI was 0.71 ± 0.44. All patients referred to be satisfied with the final outcomes and would recommend the procedure to their friends and relatives. Conclusions: TI-WFG LASIK is a new approach for myopia and myopic astigmatism correction, with preservation of the ocular optical quality and high level of patient satisfaction associated.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Effect of the variability in implantation depth of intracorneal ring segments using the femtosecond laser technology in corneal ectasia

  • Peris-Martínez, Cristina
  • Dualde-Beltrán, Cristina
  • Fernández-López, Ester
  • Roig-Revert, Maria José
  • Hernández-Díaz, Mikhail
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To analyze the impact of the depth of implantation of intracorneal ring segments on morphological, biomechanical, and clinical outcomes in ectatic corneas. Methods: This prospective longitudinal study enrolled 40 eyes of 29 patients (age 20–51 years) with corneal ectasia that underwent intracorneal ring segments implantation (KeraRing, Mediphacos). Changes in visual acuity, refraction, corneal tomography, and corneal biomechanics (Ocular Response Analyzer, Reichert) were evaluated during a 6 month follow-up. Likewise, changes in ring segment implantation depth measured by optical coherence tomography (Visante OCT, Carl Zeiss Meditec) were also evaluated. Results: Mean relative depth of implantation was 71.6 ± 5.8%, 71.5 ± 6.5%, and 71.9 ± 6.3% at 1, 3, and 6 months after surgery, respectively (p = 0.827). The difference between the real relative depth of implantation and the theoretical attempted value of 70% was not statistically significant (p = 0.072). Differences in spherical equivalent during the follow-up changed significantly depending on the level of relative depth of implantation (p = 0.036), with an increase of 0.114 D per each 1% increase in relative depth of implantation. Likewise, a decrease of –0.194 D in the steepest keratometric reading was found per each decrease of 1% in relative depth of implantation (p = 0.026). Changes in corneal thickness (p = 0.092) and biomechanics (p = 0.080) were not related to relative depth of implantation. Conclusion: The effect on visual acuity and refraction of intracorneal ring segments when implanted in corneal ectasia is less clinically relevant when the implantation is done at a very deep plane. The variability of the depth of intracorneal ring segments implantation when using femtosecond laser technology is minimal and with no clinically significant effect on clinical outcomes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Oculomotor Dysfunctions: Evidence-Based Practice, Disfunciones Oculomotoras: Práctica basada en la evidencia

  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Long-term Analysis of Epi-ON Corneal Collagen Cross-linking Outcomes in Corneal Ectasia

  • Melián, Rafael
  • Rodriguez, Vicente
  • Carreras, Humberto
  • Piñero, David P.
  • Gonzalez-Martín, Jesús M.
  • Galván, Francisco
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the 3-year follow-up clinical outcomes obtained in corneal ectasia using Epi-ON corneal collagen cross-linking (CXL). Methods: This study is a retrospective study enrolling 46 eyes from 32 patients with progressive corneal ectasia and treated with Epi-ON CXL in the period from September 2012 to April 2016. Two groups were differentiated according to the type of corneal ectasia: ectasia post-LASIK group (EPL, 12 eyes) and primary ectasia group (34 eyes). Two different platforms were used for the surgical protocol: VEGA CBM X LINKER platform (CSO, Firenze, Italy) and KXL (Avedro, Waltham, Massachusetts, USA). Visual, refractive, and corneal tomographic outcomes were evaluated during a 3-year follow-up. Results: A statistically significant improvement in the logMAR corrected distance visual acuity (CDVA) was observed in the whole sample (p <0.001) during the follow-up, with half of the sample improving one or more lines of CDVA. Likewise, only significant changes were detected in steepest keratometry (p <0.001), corneal astigmatism (p = 0.012), and index of height asymmetry (p = 0.021), with a trend to increase. Regarding the comparison between groups, more significant improvement in CDVA was found in the EPL group compared to the primary ectasia group (−0.07 ± 0.09 vs −0.15 ± 0.14, p = 0.028). Likewise, a significant trend to more corneal thinning was observed in primary ectasia group (p = 0.034). Conclusion: Epi-ON CXL is efficacious for stabilizing the progression of primary and iatrogenic ectasias for most cases, with significant improvement of visual acuity associated.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Artificial intelligence-based screening for amblyopia and its risk factors: comparison with four classic stereovision tests

  • Csizek, Zsófia
  • Mikó-Baráth, Eszter
  • Budai, Anna
  • Frigyik, Andrew B.
  • Pusztai, Ágota
  • Nemes, Vanda A.
  • Závori, László
  • Fülöp, Diána
  • Czigler, András
  • Szabó-Guth, Kitti
  • Buzás, Péter
  • Piñero, David P.
  • Jandó, Gábor
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Introduction: The development of costs-effective and sensitive screening solutions to prevent amblyopia and identify its risk factors (strabismus, refractive problems or mixed) is a significant priority of pediatric ophthalmology. The main objective of our study was to compare the classification performance of various vision screening tests, including classic, stereoacuity-based tests (Lang II, TNO, Stereo Fly, and Frisby), and non-stereoacuity-based, low-density static, dynamic, and noisy anaglyphic random dot stereograms. We determined whether the combination of non-stereoacuity-based tests integrated in the simplest artificial intelligence (AI) model could be an alternative method for vision screening. Methods: Our study, conducted in Spain and Hungary, is a non-experimental, cross-sectional diagnostic test assessment focused on pediatric eye conditions. Using convenience sampling, we enrolled 423 children aged 3.6–14 years, diagnosed with amblyopia, strabismus, or refractive errors, and compared them to age-matched emmetropic controls. Comprehensive pediatric ophthalmologic examinations ascertained diagnoses. Participants used filter glasses for stereovision tests and red-green goggles for an AI-based test over their prescribed glasses. Sensitivity, specificity, and the area under the ROC curve (AUC) were our metrics, with sensitivity being the primary endpoint. AUCs were analyzed using DeLong’s method, and binary classifications (pathologic vs. normal) were evaluated using McNemar’s matched pair and Fisher’s nonparametric tests. Results: Four non-overlapping groups were studied: (1) amblyopia (n = 46), (2) amblyogenic (n = 55), (3) non-amblyogenic (n = 128), and (4) emmetropic (n = 194), and a fifth group that was a combination of the amblyopia and amblyogenic groups. Based on AUCs, the AI combination of non-stereoacuity-based tests showed significantly better performance 0.908, 95% CI: (0.829–0.958) for detecting amblyopia and its risk factors than most classical tests: Lang II: 0.704, (0.648–0.755), Stereo Fly: 0.780, (0.714–0.837), Frisby: 0.754 (0.688–0.812), p < 0.02, n = 91, DeLong’s method). At the optimum ROC point, McNemar’s test indicated significantly higher sensitivity in accord with AUCs. Moreover, the AI solution had significantly higher sensitivity than TNO (p = 0.046, N = 134, Fisher’s test), as well, while the specificity did not differ. Discussion: The combination of multiple tests utilizing anaglyphic random dot stereograms with varying parameters (density, noise, dynamism) in AI leads to the most advanced and sensitive screening test for identifying amblyopia and amblyogenic conditions compared to all the other tests studied.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Long-Term Efficacy of the Combination of Active Vision Therapy and Occlusion in Children Strabismic and Anisometropic Amblyopia

  • Milla Baños, Myriam
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This retrospective study was conducted to evaluate the efficacy of the combined treatment of occlusion and active vision therapy in a total of 27 amblyopic children, including 14 strabismic and 13 anisometropic cases. For such purpose, changes in distance and near visual acuity as well as in the binocular function was evaluated during a two-year follow-up. In both amblyopia groups, significant improvements were found in distance and near visual acuity in the non-dominant eye (p < 0.001). In the strabismic amblyopia group, the percentage of patients with binocular function score (BF) > 3.3 decreased significantly from a baseline value of 64.3% to a two-year follow-up value of 7.1% (p < 0.001). In the anisometropic amblyopia group, this percentage also decreased significantly from a baseline value of 15.4% to a two-year follow-up value of 0.0% (p < 0.001). No recurrences were observed in the anisometropic amblyopia group, whereas recurrence occurred in two cases of the strabismic amblyopia group after finishing the vision rehabilitation process. In conclusion, the combined approach of the treatment evaluated is efficacious for providing an improvement in visual acuity and binocular function in both anisometropic and strabismic amblyopia, which was maintained over time.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

A systematic review about the impact of phakic intraocular lenses on accommodation, Revisión sistemática acerca del impacto sobre la acomodación de las lentes intraoculares fáquicas

  • Hernández Rodríguez, Carlos Javier
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Phakic intraocular lenses (pIOL) are the main treatment for patients who have either high ametropia or contraindications for laser refractive surgery. The main feature that makes this kind of lenses suitable for its implantation in young adults searching for independence of optical prescription is the conservation of accommodation, since lens extraction is not required. A systematic review has been performed to evaluate the scientific literature on the effect of pIOL implantation on accommodation. Critical assessment of the articles included in the review was achieved using the tool Critical Appraisal Skills Programme in its Spanish form (CASPe). After revising the complete text of 10 articles pre-selected, two quasi-experimental pre-post studies evaluating the outcomes of a specific model of posterior chamber pIOL were included in the systematic review. The CASPe scoring of both studies were 5/11. According to this outcome, the evidence describing the impact of the pIOL implantation on the accommodative function can be defined poor. Some trends are reported as the decrease in the amplitude of accommodation, a decrease positive relative accommodation and improvement of accommodation. However, these results should be confirmed in future controlled studies.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Validation of posterior corneal curvature measurements with color light-emitting diode topography

  • Piñero, David P.
  • Camps, Vicente J.
  • Fez Saiz, Dolores de
  • García Llopis, Celia
  • Caballero, María T.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • García Llopis, Celia|||/items/41f4c99c-ea0d-44a5-9149-f27dfd529b56
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the intrasession repeatability and validity of posterior corneal curvature and astigmatism measurements provided by a color light-emitting diode reflection topography system in healthy eyes. Methods: A total of 40 healthy eyes of 40 patients (age, 16–66 years) were enrolled. A complete eye examination was performed in all cases including posterior topographic analysis with two systems: the Scheimpflug-based system (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) and the Cassini system (i-Optics; Ophthec, The Hague, The Netherlands). With this last system, three consecutive measurements were taken to assess the level of intrasession repeatability (within-subject standard deviation, Sw; intraclass correlation coefficient). The Bland & Altman analysis was used to evaluate the interchangeability of both devices. Results: The Sw was ⩽0.06 mm for all posterior corneal radius measurements, with intraclass correlation coefficient of ⩾0.960. The Sw for the magnitude of astigmatism, J0, and J45 were 0.15, 0.04, and 0.04 D, respectively, with intraclass correlation coefficient values of 0.876, 0.897, and 0.840, respectively. Statistically significant differences between devices were found in all parameters evaluated (p ⩽ 0.025). The interchangeability analysis revealed the presence of clinically relevant limits of agreement for the flattest (0.03 to 0.50 mm) and steepest posterior corneal radii (–0.01 to 0.39 mm). In contrast, limits of agreements were not clinically relevant for the magnitude of posterior astigmatism (–0.17 to 0.27 D) and their power vector components (–0.11 to 0.15 D). Conclusion: The Cassini system provides consistent measures of posterior corneal curvature and astigmatism in healthy eyes, but only measures of posterior astigmatism can be considered as interchangeable with those provided by the Pentacam.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes

  • Molina-Martín, Ainhoa
  • Fez Saiz, Dolores de
  • Piñero, David P.
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To evaluate the intrasession repeatability for non-invasive break-up time (NIBUT) and tear meniscus height (TMH) measurements provided by a new multi-diagnostic platform, and to assess the interobserver reproducibility of TMH measures. Methods Twenty-one healthy eyes of 21 patients (age, 23–65 years) were enrolled. A complete eye examination was performed in all cases with the VX120+ device (Visionix-Luneau Technologies), including an analysis with the new Dry Eye module, performing three consecutive measurements. The within-subject standard deviation (Sw) and Bland–Altman plots were used to assess intersession repeatability. Differences between examiners for TMH were also analysed. Results No statistically significant differences were found between repeated measures of NIBUT (time associated with the first break) and TMH (p > 0.05). However, significant differences were found for NIBUT50% (time associated with half of breaks of the tear film) (p < 0.05). Mean Sw was 0.9 s, 1.4 s and 0.05 mm for NIBUT, NIBUT50% and TMH, respectively. Ranges of agreement between consecutive measures were below 3.5 s and 4.5 s for NIBUT and NIBUT50%, respectively, and below 0.16 mm for TMH. Furthermore, no significant differences were found between examiners in TMH measure, with an inter-examiner range of agreement of 0.12 mm. Conclusions The new dry eye platform of the VX120+ platform evaluated provides objective automated measures of NIBUT and TMH, with acceptable level of intrasession repeatability for clinical screening purposes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Validation of Digital Applications for Evaluation of Visual Parameters: A Narrative Review

  • Mena-Guevara, Kevin J.
  • Piñero, David P.
  • Fez Saiz, Dolores de
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The current review aimed to collect and critically analyze the scientific peer-reviewed literature that is available about the use of digital applications for evaluation of visual parameters in electronic devices (tablets and smartphones), confirming if there are studies calibrating and validating each of these applications. Three bibliographic search engines (using the search equation described in the paper) and the Mendeley reference manager search engine were used to complete the analysis. Only articles written in English and that are evaluating the use of tests in healthy patients to measure or characterize any visual function aspects using tablets or smartphones were included. Articles using electronic visual tests to assess the results of surgical procedures or are conducted in pathological conditions were excluded. A total of 19 articles meeting these inclusion and exclusion criteria were finally analyzed. One critical point of all these studies is that there was no mention of the characterization (spatial and/or colorimetrical) of screens and the stimuli used in most of them. Only two studies described some level of calibration of the digital device before the beginning of the study. Most revised articles described non-controlled comparatives studies (73.7%), reporting some level of scientific evidence on the validation of tools, although more consistent studies are needed.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses

  • Palomino-Bautista, Carlos
  • Sánchez-Jean, Rubén
  • Carmona-González, David
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate different intraocular lens (IOL) designs and to determine whether extended depth of focus (EDOF) lenses provide a higher depth of field (DOF) than the rest considering both subjective and objective measurements. Methods: A total of 100 eyes undergoing cataract surgery were divided into six groups depending on the IOL implanted: bifocal designs were Tecnis ZMB and ZLB (Abbott Laboratories, Illinois, USA), trifocal designs were Finevision (PhysIOL, Liège, Belgium) and AT LISA Tri (Carl Zeiss Meditec., Jena, Germany) and EDOF designs were Symfony (Abbott Laboratories, Illinois, USA) and MiniWell (SIFI MedTech, Catania, Italy). Subjective DOF was obtained from defocus curves for the range of vergences which provide a VA over 0.1 LogMAR and 0.2 LogMAR. Aberrometry was measured and Visual Strehl Optical Transference Function (90%) was used to quantify objectively the DOF. Results: Symfony IOL group showed better subjective and objective DOF compared to the rest of IOL groups, with statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being these differences statistically significant for all groups when compared with objective measures (p < 0.001). Conclusion: Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation acceptance. Nevertheless, both objective and subjective measures demonstrate a greater DOF for EDOF designs compared to bifocal and trifocal IOLs, being the Symfony IOL the one providing higher levels of subjective and objective DOF.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Validation of a modified version of the adult developmental eye movement test

  • Gené-Sampedro, Andrés
  • Monteiro, Pedro Miguel Lourenço
  • Bueno-Gimeno, Inmaculada
  • Gene-Morales, Javier
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This study evaluates in terms of reliability, internal consistency, and validity a modification of the Adult Developmental Eye Movement (ADEM) test, ADEM with distractors (ADEMd), designed to analyse oculomotor system, visual processing and visual attentional behaviour. 302 healthy subjects participated in the study (20–86 years old). Intrasession repeatability was evaluated by analysing the correlation between the time needed to read different parts of the test. Inter-session analyses were carried in 40 subjects by calculating intraclass correlation coefficients and using the Bland–Altman method. Validity was assessed in the outcomes obtained according to age as well as investigating the correlation between ADEMd and attentional useful field of vision (UFOV) test. Correlation coefficients between times need to read each sheet were ≥ 0.95 (p < 0.001). The inter-session intraclass correlation coefficient ranged from 0.81 in the horizontal distractor sheet to 0.97 in the vertical sheet. Bland–Altman analysis showed clinically acceptable limits of agreement. Statistically significant correlations were found between age and ADEMd outcomes (r ≥ 0.55, p < 0.001). Processing velocity, divided attention and selective attention measured with the UFOV were correlated with the horizontal distractor times (r ≥ 0.32, p < 0.001). ADEMd test may be a useful clinical tool to evaluate the combined interaction of ocular movements and visual attentional behaviour.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Short-term clinical results with a trifocal diffractive toric intraocular lens using an optimized preoperative and intraoperative protocol

  • Paredes, Beatriz
  • Mora, Javier
  • Martín, M. Dolores
  • Larrosa, Adrian
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the short-term clinical outcomes of a specific toric diffractive trifocal intraocular lens (IOL) implanted following an optimized clinical protocol in a large population. Methods: Retrospective analysis of 337 eyes of 231 patients (mean age, 62.2 years) undergoing cataract surgery with implantation of the trifocal diffractive IOL AT.LISA tri toric 939M/MP (Carl Zeiss Meditec). A strict and careful clinical protocol was followed, including an accurate measurement of corneal astigmatism, use of a latest generation IOL power calculator, photography-based method intraoperative control of IOL alignment and IOL reposition at 1 week postoperatively if needed. Clinical outcomes in terms of visual acuity, refraction, efficacy of astigmatic correction analysed by vector analysis and patient satisfaction were evaluated during a 3-month follow-up. Results: A total of 82% and 98% of eyes achieved a postoperative uncorrected distance visual acuity of 0.00 and 0.10 logMAR or better, respectively. Furthermore, 99.7%, and 100.0% of eyes showed a postoperative spherical equivalent within ± 0.50 D and ± 1.00 D, with 97.9% of eyes having a postoperative cylinder ≤ 0.50 D. Uncorrected near and intermediate visual acuities were 0.2 logMAR or better in 89.0% and 99.1% of eyes, respectively. Mean difference vector, magnitude of error and angle of error were 0.02  ±  0.14 D, 0.02  ±  0.13 D and 0.11  ±  1.18°. Patient satisfaction was referred as high or very high by 97.6% of patients. Conclusions: The implantation of the trifocal toric IOL evaluated following a careful clinical protocol provides an efficacious visual rehabilitation and astigmatic correction, leading to high levels of patient satisfaction.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Long-Term Clinically Significant Posterior Capsular Opacification Development Pattern in Eyes Implanted with an Aspheric Monofocal Intraocular Lens with a Square Optic Edge

  • Placeres Dabán, Javier
  • Elvira Cruañes, Juan Carlos
  • Azrak, César
  • Rial Alvarez, Lucia
  • Piñero, David P.
  • Belda, José I.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. To analyse the posterior capsular opacification (PCO) development pattern in the long term in eyes implanted with a monofocal intraocular lens (IOL) with a square edge all around the optic. Methods. Longitudinal retrospective study is data analyzed from a total of 7059 eyes from 4764 patients (mean age: 75.8 years) undergoing cataract surgery with implantation of an aspheric monofocal IOL (Bi-Flex HL 677AB/677P, Medicontur, Budapest, Hungary). +ese data were retrospectively collected using the electronic medical record of the hospitals involved. Nd :YAG capsulotomy rates were calculated per year during a follow-up of more than 10 years. +e Kaplan–Meier analysis was used to establish the transparent capsule survival rate. Results. +e Nd : YAG capsulotomy rate increased from 1.1% at 1 year postoperatively to 17.2% at 5 years after surgery. No significant differences were found between eyes with and without capsulotomy in terms of age (p = 0.202), gender (p = 0.061), type of anaesthesia used (p = 0.128), and presence of conditions such as hard cataract (p = 0.111) or pseudoexfoliation (p = 0.137). IOL power was significantly lower in those eyes of patients requiring Nd :YAG capsulotomy during the follow-up (p < 0.001). Significantly more eyes implanted with the preloaded model of the IOL required capsulotomy (p < 0.001). Mean survival time and rate were 9.38 years and 85.9%, respectively. Conclusions. Most eyes undergoing cataract with implantation of the Bi-Flex IOL do not develop a clinically significant PCO requiring Nd : YAG capsulotomy in the long term. IOL material and design may be the main factors accounting for this finding.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

What we know about the scleral profile and its impact on contact lens fitting

  • Rojas Viñuela, Javier
  • Frogozo, Melanie J.
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Scleral contact lens fitting has provided practitioners with one of the earliest pieces of evidence that the sclera was more often asymmetric than symmetric. Some preliminary observations such as different haptic alignment patterns over the sclera in 360 degrees, the appearance of fogging in the fluid chamber and excessive tear out-in flow through specific meridians, quadrants, or areas of the haptic provide evidence of some scleral asymmetry. The advent of technologies that allowed measurement of the scleral profile led to formal research confirming that only about 6% of scleras are symmetric, while the rest are toric, quad-specific, or irregular. This has an evident impact on how to focus scleral lens fitting. Measuring the scleral profile also provided us with true ocular sagittal height data for cord diameters beyond the cornea. Although high variability was expected in pathological eyes, healthy eyes also showed a wide range of ocular sagittal heights. Due to this variability among healthy eyes, a discussion has emerged on whether the one-size-fits-all approach to soft lens fitting is a proper strategy to fit the whole spectrum of sagittal heights. The traditional mode of selecting the parameters for custom soft lenses through corneal parameters is also questioned.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Intrasession Repeatability of Biometric Measurements Obtained with a Low-Coherence Interferometry System in Pseudophakic Eyes

  • Fukumitsu, Hideki
  • Camps, Vicente J.
  • Piñero, David P.
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the intrasession repeatability of the biometric measurements obtained with a low-coherence reflectometry optical biometer in pseudophakic eyes implanted with two different types of intraocular lens (IOL). Methods: Prospective, single-center, comparative study including 69 eyes of 69 patients with ages ranging from 51 to 92 years. Previous uncomplicated cataract surgery had been performed in all patients 1 to 2 months before measurements, with implantation of the Acrysof SN60WF IOL in 35 eyes (35 patients, group 1) and the IOL Akreos MI60 in 34 eyes (34 patients, group 2). A complete postoperative ophthalmological examination was performed including three consecutive measurements with the “Aladdin” system from (Topcon, Japan). Intrasession repeatability of axial length (AXL), anterior chamber depth (ACD) and IOL thickness (IOLT) were assessed with the within-subject standard deviation (Sw), intraobserver precision (1.96 × Sw), coefficient of variation (CV) and intraclass correlation coefficient (ICC). Results: The Sw for AXL measurements was 0.03 and 0.05 mm in groups 1 and 2, respectively, with ICC of 1.000 and 0.999 (CV: 0.14% and 0.22%) (p ≤ 0.031). Concerning pseudophakic ACD, the Sw was 0.03 and 0.09 mm in groups 1 and 2, respectively, with ICC of 0.992 and 0.956 (CV: 0.55% and 1.75%) (p ≤ 0.021). The variability of IOLT measurements was high in both groups, with Sw of 0.12 and 0.29 mm for groups 1 and 2 (p = .008), respectively, and ICC of 0.065 and 0.770 (CV: 20.84% and 62.39%). Conclusions: The optical biometer “Aladdin” (Topcon, Japan) provides consistent measurements of AXL and ACD in pseudophakic eyes. However, there is a limitation in the consistency of IOLT measurements that should be investigated further.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Study protocol for a randomized controlled trial of the NEIVATECH virtual reality system to improve visual function in children with anisometropic amblyopia

  • Leal-Vega, Luis
  • Piñero, David P.
  • Hernández Rodríguez, Carlos Javier
  • Molina-Martín, Ainhoa
  • Morales-Quezada, León
  • Vallelado Álvarez, Ana Isabel
  • Arenillas, Juan F.
  • Coco-Martin, María Begoña
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Background: Interest in developing alternative methods for the treatment of amblyopia has long been a topic of interest among clinicians and researchers, as prescribed occlusion and penalization therapies do not always provide an effective response and are associated with a high risk of recurrence and non-compliance. Here, we present the protocol of a small-scale RCT to evaluate the safety and clinical efficacy of a novel VR-based system designed to provide binocular vision training to children with anisometropic amblyopia. Methods: We aim to recruit a total of 60 children with anisometropic amblyopia aged 5-17 years with no previous treatment for amblyopia other than refractive correction from the pediatric ophthalmology units of the University Clinical Hospital of Valladolid and the Vithas Medimar International Hospital of Alicante. Children who meet the eligibility criteria and consent to participate will be randomly assigned to a three-month intervention group of 18 half-hour in-office therapy sessions with the NEIVATECH system (group A) or to a parallel group receiving 2 hours of conventional patching per day at home for the same period of time (group B). Assessments of visual function will be carried out before the intervention and at 1, 2 and 3 months, with changes in distance BCVA being the primary outcome measure to be considered. Patient safety, compliance, satisfaction and acceptance to treatment will also be assessed after therapy as other valuable outcome measures. In addition, a rsfMRI scan will be performed on a subgroup of 5 patients from each group at the pre-intervention visit and at the post-intervention visit to test the effects of both therapies on neural plasticity in the visual cortex. Discussion: The NEIVATECH system has been conceived as a serious game designed to provide binocular vision training to anisometropic amblyopic children by complementing the concepts of perceptual learning, dichoptic training and gamification in an immersive VR environment. We hope that this novel approach may lead to greater improvements in vision performance than those provided so far by conventional patching in anisometropic amblyopic children. Trial registration: This protocol was registered with ClinicalTrials.gov (NCT04819386) on 29 March 2021.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Global multi-site, prospective analysis of cataract surgery outcomes following ICHOM standards: the European CAT-Community

  • Zijlmans, Bart L.M.
  • van Zijderveld, Rogier
  • Manzulli, Michele
  • Garay-Aramburu, Gonzaga
  • Czapski, Philipp
  • Eter, Nicole
  • Diener, Raphael
  • Torras, Josep
  • Tognetto, Daniele
  • Giglio, Rosa
  • De Giacinto, Chiara
  • Fernández, Joaquín
  • O’Donnell, Clare
  • Piñero, David P.
  • European CAT-Community Study Group
  • Knitel, Annemijn
  • Bergado-Mijangos, Roberto
  • Coello-Ojeda, Daniel
  • Ozaeta, Itziar
  • Macias-Murelaga, Beatriz
  • Garrido Fierro, Jesús
  • Dalmasso, Cristian E.
  • Garcia-Gómez, Pío Jesús
  • Himanka, Mari
  • Martínez, Javier
  • Chang-Sotomayor, Meilin
  • Camós-Carreras, Anna
  • Spencer, Felipe
  • Sabater-Cruz, Noelia
  • Scardellato, Carlo
  • Dell’Aquila, Carmen
  • Pian, Giulia
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To evaluate in a large sample of patients from 10 different European centers the results of cataract surgery, characterizing the relationship between patient-reported outcomes (PROMs) and clinician-reported outcome measures (CROMs). Methods Prospective non-interventional multicenter observational descriptive study analyzing the clinical outcomes of a total of 3799 cases undergoing cataract surgery (mean age: 72.7 years). In all cases, the cataract surgery standard developed by the International Consortium for Health Outcomes Measurements (ICHOM) was used to register the clinical data. Three-month postoperative visual acuity and refraction data were considered CROMs, whereas Rasch-calibrated item 2 (RCCQ2) and total Catquest-9SF score (CQ) were considered PROMs. Results Postoperative corrected distance visual acuity (CDVA) was 0.3 logMAR or better in 88.7% (2505/2823) of eyes. Mean differences between preoperative and postoperative RCCQ2 and CQ scores were −3.09 and −2.39, respectively. Visual function improvement with surgery was reported by 91.5% (2163/2364) of patients. Statistically significant, although weak, correlations of postoperative CDVA with postoperative refraction, PROMs, and complications were found (0.133 ≤ r ≤0.289, p < 0.001). A predictive model (R2: 0.254) of postoperative CDVA considering 10 variables was obtained, including preoperative CDVA, different ocular comorbidities, age, gender and intraoperative complications. Likewise, another predictive model (R2: 0.148) of postoperative CQ considering a total of 14 variables was obtained, including additionally preoperative CQ, target refraction and previous surgeries. Conclusions Cataract surgery provides an improved functional vision in most of patients although this improvement can be limited by ocular comorbidities and complications. The relationship between PROMs and CROMs is multifactorial and complex.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Morphogeometric analysis for characterization of keratoconus considering the spatial localization and projection of apex and minimum corneal thickness point

  • Velázquez, Jose S.
  • Cavas Martínez, Francisco
  • Piñero, David P.
  • Cañavate, Francisco J.F.
  • Alio del Barrio, Jorge
  • Alió, Jorge L.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
This work evaluates changes in new morphogeometric indices developed considering the position of anterior and posterior corneal apex and minimum corneal thickness (MCT) point in keratoconus. This prospective comparative study included 440 eyes of 440 patients (age, 7–99 years): control (124 eyes) and keratoconus (KC) groups (316 eyes). Tomographic information (Sirius®, Costruzione Strumenti Oftalmici, Italy) was treated with SolidWorks v2013, creating the following morphogeometric parameters: geometric axis–apex line angle (GA–AP), geometric axis–MCT line angle (GA–MCT, apex line–MCT line angle (AP–MCT), and distances between apex and MCT points on the anterior (anterior AP–MCTd) and posterior corneal surface (posterior AP–MCTd). Statistically significant higher values of GA–AP, GA–MCT, AP–MCT and anterior AP–MCTd were found in the keratoconus group (p ≤ 0.001). Moderate significant correlations of corneal aberrations (r ≥ 0.587, p < 0.001) and corneal thickness parameters (r ≤ −0.414, p < 0.001) with GA–AP and AP–MCT were found. Anterior asphericity was found to be significantly correlated with anterior and posterior AP–MCTd (r ≥ 0.430, p < 0.001). Likewise, GA–AP and AP–MCT showed a good diagnostic ability for the detection of keratoconus, with optimal cutoff values of 9.61° (sensitivity 85.5%, specificity 80.3%) and 18.08° (sensitivity 80.5%, specificity 78.7%), respectively. These new morphogeometric indices allow a clinical characterization of the 3-D structural alteration occurring in keratoconus, with less coincidence in the spatial projection of the apex and MCT points of both corneal surfaces. Future studies should confirm the potential impact on the precision of these indices of the variability of posterior corneal surface measurements obtained with Scheimpflug imaging technology.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Distribution of Visual and Oculomotor Alterations in a Clinical Population of Children with and without Neurodevelopmental Disorders

  • Bilbao, Carmen
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
A prospective, non-randomized comparative study was conducted to compare the distribution of oculomotor and visual alterations in children with neurodevelopmental disorders and healthy children without such disorders. Sixty-nine children (aged 6–13 years) were enrolled and divided into three groups: a control group (CG) of 23 healthy children; a group of 18 healthy children with oculomotor abnormalities (OAG); and a group of 28 children with a neurodevelopmental disorder (NDDG), with 15 cases of dyslexia, 7 cases of developmental coordination disorder (DCD) and 6 cases of attention deficit/hyperactivity disorder (ADHD). Significantly worse near stereopsis was found in NDDG compared with CG (p < 0.001) and OAG (p = 0.001). Likewise, a significantly lower amplitude of accommodation was found in NDDG compared with CG in both the right (p = 0.001) and left eyes (p < 0.001). No statistically significant differences between groups were found in the measurement of near and distance phoria (p ≥ 0.557), near point of convergence (p = 0.700) and fusional vergences (p ≥ 0.059). Significantly impaired oculomotor test scores were found in NDDG compared with CG (p < 0.001), with no significant differences between OAG and NDDG (p ≥ 0.063). The comparison between the three types of neurodevelopmental disorders included revealed the presence of a significantly lower amplitude of accommodation in children with DCD compared with dyslexics. Furthermore, less exophoria at near was present in children with dyslexia compared with children with ADHD (p = 0.018) and DCD (p = 0.054). In conclusion, children with dyslexia, ADHD and DCD show an altered oculomotor pattern and a more reduced amplitude of accommodation, not always compatible with the diagnostic criteria of an accommodative insufficiency. Accommodative and binocular vision problems are not always present in these children and cannot be considered an etiologic factor.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Intrasession repeatability of corneal, limbal and scleral measurements obtained with a fourier transform profilometer

  • Bataille, Laurent
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To evaluate the intrasession repeatability of corneal, limbal and scleral measurements obtained by an experienced operator with a Fourier transform profilometer in healthy eyes. Methods: Prospective, single-center study including 35 eyes of 35 participants with ages ranging from 13 to 52 years. All patients underwent three consecutive corneoscleral topographic evaluations with the Eye Surface Profiler (ESP) system (Eaglet Eye b.v.). Intrasession repeatability was analyzed for different geometric and sagittal height variables using the following parameters: the within-subject standard deviation (Sw) of the three consecutive measurements, intrasubject precision (1.96 × Sw), coefficient of variation (CV) and the intraclass correlation coefficient (ICC). Results: Inner best fit sphere (BFS) showed good repeatability, with ICC of 0.844. Higher variability was observed for the repeated measurements of limbus and outer BFS, with ICCs of 0.636 and 0.739, respectively. For mean corneal and scleral radius, ICCs were 0.933 and 0.888, respectively. The repeatability of all sagittal height data was good for all chords evaluated (11–15 mm), with Sw values from 0.02 to 0.11 mm, and ICCs from 0.568 to 0.909. A significant positive correlation was found between the magnitude of temporal-nasal sagittal height difference for all measured chords and its Sw associated. Conclusion: The ESP system can provide consistent measurements of sagittal height data for different chord diameters as well as for mean corneal and scleral radius in healthy eyes. Best fit approaches for limbal and scleral areas were less repeatable, although within a clinically acceptable range.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Iterative Methods for the Biomechanical Evaluation of Corneal Response. A Case Study in the Measurement Phase

  • Gómez, Carmelo
  • Piñero, David P.
  • Paredes, Manuel
  • Alió, Jorge L.
  • Cavas Martínez, Francisco
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The number of corneal surgeries steadily grew in recent years and boosted the development of corneal biomechanical models. These models can contribute to simulating surgery by reducing associated risks and the need for secondary interventions due to ectasias or other problems related to correcting other diseases. Biomechanical models are based on the geometry obtained with corneal topography, which is affected by intraocular pressure and material properties. Knowledge of stress distribution in the measurement phase is a key factor for improving the accuracy of in silico mechanical models. In this work, the results obtained by two different methods: prestress method and displacements method were compared to evaluate the stress and strain distribution in a general geometric model based on the Navarro eye geometry and two real corneal geometries. The results show that both methods are equivalent for the achievement of the stress distribution in the measurement phase. Stress distribution over the corneal geometry in the measurement phase is a key factor for accurate biomechanical simulations, and these simulations could help to develop patient-specific models and reduce the number of secondary interventions in clinical practice.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Ocular fixation and macular integrity by microperimetry in multiple sclerosis

  • Gil-Casas, Amparo
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose To characterize the fixation and macular integrity of subjects with multiple sclerosis (MS) with and without previous optic neuritis (ON) using microperimetry (MP). Methods Fifty-five eyes of MS patients, subdivided into three groups (28 eyes without ON, 16 with previous ON, and 11 eyes with previous ON in the contralateral eye), and 43 healthy eyes were enrolled (January–November 2018). All cases were evaluated using the MAIA microperimeter (Centervue), analyzing the following parameters: average macular threshold (AT), fixation indexes (P1 and P2), bivariate contour ellipse area (BCEA) for 95% and 63% of points, and horizontal (H) and vertical (V) axes of the ellipse of fixation. Results All MS groups showed a significant reduced AT compared with the control group (p < 0.001). This reduction was more representative (p < 0.001) in eyes with previous ON. No statistically significant differences were found between MS patients with and without previous ON (p > 0.05). Mean AT was correlated with the examination time in all three groups (between ρ = − 0.798 p < 0.001 and ρ = − 0.49 p < 0.001). Significant differences in fixation parameters were only found between control and MS with ON groups (p < 0.02). The ratio of the disease showed a significant correlation with fixation parameters in MS groups (p < 0.02), but not with AT. Conclusions In MS patients, macular sensitivity is altered, especially in eyes with previous ON. Likewise, a fixational instability is present in MS patients with ON, with more increase of the V axis of the fixation area than of the H. The ratio of the disease also affects the patient fixation pattern.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Differences in Visual Working and Mobile Phone Usage Distance according to the Job Profile

  • Soler, Fernando
  • Sánchez-García, Alicia
  • Molina-Martín, Ainhoa
  • Fez Saiz, Dolores de
  • Díaz, Valentín
  • Piñero, David P.
  • Fez Saiz, Dolores de|||/items/f12557f0-dc97-45a4-99fa-734ab6522f11
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To analyze and characterize the pattern of visual working distance (WD) and mobile phone usage distance (MPD) in a large population, analyzing the differences in these parameters according to the job profile. Methods: Cross-sectional study consisting of a screening campaign evaluating the visual status of professionals from seven different environments. A total of 454 participants with a mean age of 41.5 years (range, 22–64 years) were revised. The screening campaign consisted of several rapid tests performed in a single session in the usual work environment of each participant, including measurement of WD, arm length, and MPD (VisionApp, VisionApp Solutions S.L.). Results: WD was significantly longer than MPD (82.5 ± 150.6 vs. 31.9 ± 6.3 cm, p < .001), whereas no significant differences were found between arm length (74.3 ± 4.8 cm) and WD (p = .493). WD was below 80 cm in 89.6% (407/454) of participants, whereas MPD was below 40 cm in 89.0% (404/454). No significant correlation was found between WD and MPD (r = 0.126, p = .117). Statistically significant differences were detected among job profile subgroups in WD (p < .001), with military personnel showing significantly longer WD than other professionals (p ≤ 0.018). Significant differences were also found between job profile subgroups in MPD (p = .006), with shorter MPDs for shoe factory professionals compared to sellers (p = .046). Conclusions: WD and MPD vary significantly among individuals, but always showing a shorter MPD. WD varies significantly also according to the job profile, being necessary to consider this information when selecting the most optimal optical aid in each case, especially for the compensation of presbyopia.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Relationship between Axial Length and Corneo-Scleral Topography: A Preliminary Study

  • Bataille, Laurent
  • Molina-Martín, Ainhoa
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The main objective of the current study was to investigate further the relationship of the overall length of the eye with a great variety of anterior segment parameters, including scleral geometry. A total of 64 eyes of 32 participants with ages from 12 to 52 years were included in this prospective non-randomized single-center study. All participants underwent a complete eye examination, including an analysis of corneo-scleral shape with a Fourier-domain profilometer. A strong negative correlation was found between axial length and temporal-nasal ocular sagittal height difference for different chord lengths. For the right eye, a consistent and stable linear model was obtained to predict the axial length from the spherical equivalent, the corneal diameter, the high-order aberrations root mean square, and the minimum sagittal height for 13- and 14-mm chord. For the left eye, a model was obtained to predict the axial length from the spherical equivalent and the mean corneal curvature, including other parameters such as corneal diameter or high-order aberrations, depending on the chord length, considered for estimating the sagittal height values. More studies with larger samples are needed to confirm these preliminary outcomes.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Intracorneal Ring Segment Implantation for the Management of Keratoconus in Children

  • Larco, Pablo
  • Larco Jr., Pablo
  • Torres, Daniel
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The short-term safety and efficacy of intracorneal ring segment (ICRS) implantation in keratoconus eyes of children are investigated in this study. A retrospective interventional case series study including a total of 33 keratoconus eyes (age 8 to 17 years) that had undergone ICRS (Keraring segments, Mediphacos) implantation was conducted. Information about visual, refractive, pachymetric, corneal topographic and aberrometric, and corneal endothelial changes during a 3-month follow-up were extracted and analysed. A significant improvement was observed in logMAR corrected distance visual acuity (p = 0.005), combined with a statistically significant reduction in keratometric readings (p < 0.001). A reduction in the magnitude of corneal astigmatism of ≥1 D was observed in 52.8% of eyes. No significant changes were observed in corneal endothelial density (p = 0.317). Significant changes were found in the anterior vertical coma component (p = 0.002) as well as in the spherical aberration of the posterior corneal surface (p = 0.004). Only two relevant complications were described: one corneal microperforation with penetration of the ring segment into the anterior chamber (1 eye, 2.8%), and a case of ring extrusion (1 eye, 2.8%). ICRS implantation in children keratoconus eyes allows a reduction of corneal astigmatism, irregularity, and aberrations, leading to a significant visual improvement.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical Characterization of Oculomotricity in Children with and without Specific Learning Disorders

  • Bilbao, Carmen
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Children with specific learning disorders have been associated with oculomotor problems, with their analysis even suggested to be a potential diagnostic tool. A prospective non-randomized comparative study evaluating 59 children (6–13 years old) divided into three groups was conducted: a control group (CG) including 15 healthy emmetropic children; a group of 18 healthy children with oculomotor abnormalities (OAG); and a group of 26 children diagnosed with specific learning disorders (LDG). In all groups, besides a complete eye exam, oculomotricity was characterized with two clinical tests: Northeastern State University College of Optometry’s Oculomotor (NSUCO) and Developmental Eye Movement (DEM) tests. Concerning the NSUCO test, lower ability, precision, and head/body movement associated scorings were obtained for both smooth pursuits and saccades in OAG and LDG when compared to the CG (p < 0.001). Likewise, significantly longer time needed to read the horizontal sheet of the DEM test and a higher DEM ratio were found in OAG and LDG compared to CG (p ≤ 0.003). No differences between LDG and OAG were found in the performance with the two oculomotor tests (p ≥ 0.141). Oculomotor anomalies can be present in children with and without specific learning disorders, and therefore cannot be used as diagnostic criteria of these type of disorders.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Changes in the 3D Corneal Structure and Morphogeometric Properties in Keratoconus after Corneal Collagen Crosslinking

  • Alifa, Ramón
  • Piñero, David P.
  • Velázquez, Jose S.
  • Alio del Barrio, Jorge
  • Cavas Martínez, Francisco
  • Alió, Jorge L.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Keratoconus is an ectatic disorder that is presently considered one of the most prevalent reasons for keratoplasty. Corneal collagen crosslinking (CXL) is the only proven treatment option available that is capable of halting the progression of the disease by stabilizing the cone in 90% of cases, and by also reducing refractive error and maximal keratometry. This study assesses, by means of a 3D morphogeometric analysis procedure developed by our research team, the corneal structure changes that occur immediately after CXL treatment and during a 6 month follow-up period. A total of 19 eyes from 19 patients diagnosed with keratoconus who underwent CXL were included, and several variables derived from the morphogeometric analysis were calculated and evaluated for the pre-operative, 3 month postoperative, and 6 month postoperative states. Significant reductions were detected in central corneal thickness and corneal spherical-like root mean square (RMS) 3 months after surgery, with non-significant regression of the effect afterward. Significant reductions in the total corneal area/volume were found, with some levels of regression after 6 months in certain volumetric parameters. In conclusion, the eyes with higher values for morphogeometric parameters—posterior apex deviation (PAD), anterior minimum thickness point deviation (AMTPD), and posterior minimum thickness point deviation (PMTPD)—seemed more likely to undergo aberrometric improvement as a result of CXL surgery.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Short and long term corneal biomechanical analysis after overnight orthokeratology

  • Nieto-Bona, Amelia
  • Porras-Ángel, Paloma
  • Ayllón-Gordillo, Adela Elena
  • Carracedo, Gonzalo
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
AIM: To investigate the short and long term corneal biomechanical changes after overnight orthokeratology (OK) and compare them with those occurring in subjects not wearing contact lenses. METHODS: Retrospective case control study enrolling 54 subjects that were divided into three groups 18 subjects each: control group (CG), short term (15 nights) OK (STOK) group, and long term (more than 1y of OK wear) OK (LTOK) group. Corneal biomechanics were characterized using the CorVis? ST system (Oculus), recording parameters such as time [first/second applanation time (AT1, AT2)], speed [velocity of corneal apex at the first/second applanation time (AV1, AV2)], and amplitude of deformation (AD1, AD2) in the first and second corneal flattening, corneal stiffness (SPA1), biomechanically corrected intraocular pressure (bIOP) and corneal (CBI) and tomographic biomechanical indices (TBI). RESULTS: Significantly lower AD1 and standard deviate on of Ambrosio’s relational average thickness related to the horizontal profile (ARTh) values were found in the OK groups compared to CG (P<0.05). Likewise, significantly higher values of CBI were found in STOK and LTOK groups compared to CG (P<0.01). No significant differences between groups were found in integrated radius index (P=0.24), strain stress index (P=0.22), tomographic biomechanical index (P=0.91) and corneal stiffness parameter (SPA1, P=0.97). Significant inverse correlations were found between corneal thickness and CBI in STOK (r= -0.90, P<0.01) and LTOK groups (r=-0.71, P<0.01). CONCLUSION: OK does not seem to alter significantly the corneal biomechanical properties, but special care should be taken when analyzing biomechanical parameters influenced by corneal thickness such as amplitude of deformation, ARTh or CBI, because they change significantly after treatment but mainly due to the reduction and pachymetric progression induced by the corneal molding secondary to OK treatment.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparison of Four Intraocular Power Calculation Formulas in Keratoconus Eyes

  • Camps, Vicente J.
  • Fikry Riad, Ramy R.
  • Caravaca Arens, Esteban
  • Labib, Fady E.
  • Mateo Pérez, Verónica
  • Caballero, María T.
  • Piñero, David P.
  • Caballero, María T.|||/items/c8eb4e12-622a-4649-9228-178d8959d3c2
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Introduction: This study aimed to evaluate the differences in Intraocular Lens (IOL) power in keratoconus (KC) eyes between calculations obtained clinically with the most commonly used formulas in healthy eyes (SRK T, Holladay 1, Hoffer Q and Haigis) as well as to define predictive factors for such differences. Methods: This retrospective study comprised 43 keratoconus eyes of 22 patients with no previous ocular surgery. IOL powers were calculated with SRK T, Holladay 1, Hoffer Q, and Haigis formulas, considering the Effective Lens Position (ELP) of each formula and the desired refraction of 0 D (Rdes=0 D). Results: All differences between formulas were statistically significant and clinically relevant. Haigis formula always provided higher values compared to the rest of the formulas, with the highest differences observed when comparing Haigis with Hoffer (0.84 D) and Hoffer Q (1.17 D) formulas. The lowest difference was obtained for the comparison between SRK-T and Holladay 1 formulas (0.22 D). Differences of the Haigis formula compared to the rest were higher as the magnitude of the IOL power calculated decreased, becoming the patient more myopic. Increased differences between Haigis and Hoffer formulas were observed in eyes with deep anterior chambers, steeper anterior and posterior corneal surfaces, and high axial lengths. Conclusion: The most comparable results in IOL power in keratoconus are provided by the Holladay 1 and SRK T formulas, whereas the Haigis formula provides the most discrepant outcome. The consideration of the curvature of the second corneal surface in IOL power calculations in keratoconus may decrease the variability between calculation methods. However, other factors as anterior chamber depth or axial length are also relevant.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Comparing sagittal heights calculated using corneal parameters and those measured with profilometry

  • Rojas Viñuela, Javier
  • Piñero, David P.
  • Burgos Martínez, Mercedes
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To compare the sagittal height of the anterior eye (OC-SAG) calculated using corneal parameters with the OC-SAG measured by profilometry. Method: Seventy right eyes of soft contact lens wearers measured with the ESP (Eaglet Eye, The Netherlands) after lens removal were retrospectively analyzed for this study. The OC-SAG of the eyes was calculated using mean k-values, eccentricity and the inner (corneal) radius obtained with the ESP for an 11-mm cord diameter. It was then extrapolated to chord diameters of 14, 14.5 and 15 mm. These values were compared with OC-SAG values obtained with the ESP for the same chord diameters. Additionally, the OC-SAG was calculated through the formula used by a lab that manufactures custom soft lenses (mark’ennovy, Madrid, Spain) and compared again with the values obtained using the ESP. Results: Differences between calculated OC-SAG obviating the shape factor were 121 ± 44, 155 ± 105, 172 ± 117 and 189 ± 129 µm for chord diameters of 11, 14, 14.5 and 15 mm, respectively (p < 0.001). When the shape factor was included in the calculation, differences were 28 ± 48, 62 ± 102, 79 ± 113 and 96 ± 123 µm (p < 0.001). When the inner best fit sphere was used to estimate OC-SAG, differences were 34 ± 11, 0 ± 72, 17 ± 86 and 34 ± 99, respectively, with no significant differences for the 14 and 14.5 mm-chord diameters (p = 0.99 and 0.11, respectively). Correlation coefficients between OC-SAG calculated and measured OC-SAG ranged from 0.53 to 0.90 depending on the chord diameter used. When the mark’ennovy formula was used to calculate the OC-SAG as the lens diameter proposed by the formula, the difference was −47 ± 147 µm (p < 0.01). Conclusions: Differences between the OC-SAG calculated using corneal parameters and that measured with a profilometer are statistically and clinically significant, especially for large chord diameters. The impact of this on contact lens fitting should be addressed in future studies.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Developmental Eye Movement (DEM) and King-Devick (K-D) Performance in Multiple Sclerosis

  • Gil-Casas, Amparo
  • Piñero, David P.
  • Molina-Martín, Ainhoa
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Eye movement disorders have been reported in patients with multiple sclerosis (MS) as saccadic disturbances. Several methods have been described for the assessment of saccades, including the K-D and DEM tests. The performance of these tests also involves attention, language, and other brain areas which have been reported to be altered in MS patients. The aim of the study was to determine how developmental eye movement (DEM) and King-Devick (K-D) tests are affected in MS-patients. It was also to analyze whether a resolved episode of optic neuritis (ON) has a negative influence. Subjects with MS showed worse outcomes (higher times) in DEM test (72 (26) s and a K-D test (56 (22) s compared to healthy subjects (64 (7) s and 55 (11) s, respectively). However, a previous ON episode did not worsen the MS-times of DEM (80 (33) s or of K-D (62 (33) s. Horizontal saccades with the DEM showed differences between subjects with MS (with and without ON) and healthy ones (p < 0.05), whereas no such differences were found in the vertical saccades. According to the DEM instructions, MS patients would present heterogeneous oculomotor and non-visual disturbances. Regarding the K-D test, only the third card (the most complex one) showed differences (p < 0.05) between groups. These tests can capture impairment of attention, language, and other areas that correlate with suboptimal brain function in addition to the oculomotor dysfunctions present in subjects with MS.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Could anatomical changes occurring with cataract surgery have a clinically significant effect on effective intraocular lens position?

  • Fukumitsu, Hideki
  • Camps, Vicente J.
  • Miraflores, Sara
  • Piñero, David P.
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose: To assess if the calculation of the effective lens position (ELP) of two different monofocal intraocular lenses (IOLs) could be optimized by considering the potential anatomical changes occurring after cataract surgery. Methods: Prospective, descriptive, single-center study involving 472 eyes of 280 subjects (mean age 73.5 years) undergoing cataract surgery that were divided into two groups according to the IOL implanted: group 1330 eyes with AcrySof IQ SN60WF (Alcon), and group 2142 eyes with Akreos MI60L (Bausch + Lomb). Refractive and biometric changes were evaluated during a period of 6-month follow-up with an optical biometer (considering potential measurement artifacts). Comparison of ELP estimated with the SRK-T formula (ELPSRK-T) and ELP calculated considering clinical real data was made (ELPAXL-corrected clinical). Results: Besides significant changes in refraction (p ≤ 0.020), a significant increase in anterior chamber depth (ACD) (p < 0.001) and a significant reduction in the axial length (AXL) (p < 0.001) were detected at 1 month after surgery. Mean 1-month postoperative AXL change was − 0.08 ± 0.06 and − 0.10 ± 0.11 mm in groups 1 and 2, respectively (p = 0.001), with no significant changes afterward. Mean difference between ELPSRK-T and ELPAXL-corrected clinical was 0.17 ± 0.39 and − 0.23 ± 0.43 mm in groups 1 and 2, respectively (p < 0.001). A strong and statistically significant correlation of these differences with the prediction refractive error was found in both groups (group 1, r =  − 0.723; group 2, r =  − 0.819; p < 0.001). Conclusions: The estimation of ELP using the SRK-T formula for the two IOLs evaluated may be optimized considering biometric changes with surgery, helping to understand better some problems of refractive unpredictability.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Systematic review of potential causes of intraocular lens opacification

  • Fernández, Joaquín
  • Sánchez-García, Alicia
  • Rodríguez-Vallejo, Manuel
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Intraocular lens (IOL) opacification is an infrequent complication of cataract surgery. Surface analysis has demonstrated that the opacification of IOLs is related to calcium or phosphate precipitation on or within the lenses, but the associated mechanisms are unknown, and the scientific literature is heterogeneous and limited to case series and retrospective studies. The purpose of this systematic review was to analyse the most frequent conditions associated with opacification of IOLs reported by studies. A search was carried out using the PubMed MEDLINE, Web of Science and Scopus databases. The quality of the studies selected was evaluated using the Pierson tool. The search provided a total of 811 articles, of which 39 were selected following the inclusion and exclusion criteria. The most common opacified lenses were hydrophilic IOLs according to our analysis. The mean time of appearance of lens opacification was 14.93 ± 17.82 months. The most frequent conditions associated with opacification of the IOLs were Descemet Stripping with Automated Endothelial Keratoplasty (DSAEK/DSEK) and diabetes mellitus (DM), followed by pars plana vitrectomy (PPV), blood hypertension (HT), and glaucoma. Concerning the quality analysis, the mean score was 7.00 ± 1.43 (scoring range from 0 to 10), indicating an acceptable quality of the case reports and retrospective studies. In conclusion, DSAEK/DSEK, DM, PPV, glaucoma and hypertension are conditions with potential risk of IOL opacification after cataract surgery, especially when implanting hydrophilic acrylic IOLs.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Pellucid marginal degeneration: Detection, discrimination from other corneal ectatic disorders and progression

  • Martínez-Abad, Antonio
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Pellucid marginal degeneration (PMD) is a non-inflammatory ectatic corneal disease characterized by a narrow band of corneal thinning separated from the limbus by a relatively uninvolved area 1–2 mm in width. It is a rare corneal disorder that shares many clinical characteristics with other corneal ectasias, such as keratoconus, keratoglobus or Terrien marginal degeneration. PMD usually starts later in life than keratoconus and progresses slower than keratoconus. Slit-lamp examination is very useful to distinguish PMD from other corneal ectatic disorders with inflammatory nature. Corneal topographic indices and the classical crab-claw topographic pattern cannot be used as the main tool to distinguish between PMD and keratoconus. New Scheimpflug imaging-based devices have shown the importance and usefulness of the pachymetric map for an appropriate diagnosis of PMD. In addition, biomechanical and densitometric properties have been studied as complementary techniques to help in the diagnosis of PMD.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Analysis of Daily Visual Habits in a Presbyopic Population

  • Ribeiro, Filomena
  • Ferreira, Tiago B.
  • Silva, Diana
  • Matos, Ana Cláudia
  • Gaspar, Sylvia
  • Piñero, David P.
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Purpose. To evaluate and report the visual habits and requirements of a sample of presbyopic patients using an advanced sensor. Methods. Transversal study collecting clinical data from 40 presbyopes candidates for presbyopia-correction intraocular lens (IOL) implantation with mean age of 61.0 years (43–80 years). A complete ophthalmological examination was performed in all patients including visual, refractive, an ocular biometric analysis. Furthermore, patients were instructed about the use of the Vivior Monitor system (Vivior AG, Zürich, Switzerland), which consists of a series of sensors attached to the rim of the patient’s glasses that capture information about the visual behavior of the patient. This device was worn for a period of 36 hours or more. The data collected were transferred to a database and analyzed. Results. Mean percentages of time dedicated to distance, intermediate, and near vision were 27.25 ± 11.93% (5–65%), 30.23 ± 9.36% (12–50%), and 42.53 ± 14.96% (13–78%), respectively. Mean percentages of time performing activities under photopic, mesopic, and scotopic conditions were 37.08 ± 23.20% (5–87%), 33.65 ± 13.84% (6–67%), and 29.28 ± 17.03% (4–65%). The percentage of time with digital screens ranged from 2% to 48%. Age was significantly correlated with the percentage of time dedicated to distance vision (r = 0.317, p = 0.047) and to activities performed under photopic conditions (r = −0.344, p = 0.030). Conclusions. Distance and illumination conditions used to perform different daily life visual activities vary significantly among presbyopes, with a trend to the dedication of more time to intermediate and near visual activities performed under photopic and mesopic conditions. Data interpretation should be done with care until a proper validation of the device used.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Virtual Reality Visual Training in an Adult Patient with Anisometropic Amblyopia: Visual and Functional Magnetic Resonance Outcomes

  • Halicka, Juraj
  • Bittsansky, Michal
  • Sivak, Stefan
  • Piñero, David P.
  • Ziak, Peter
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
A case of an adult with anisometropic amblyopia who underwent a successful vision therapy program playing videogames in a virtual reality environment is described, reporting changes in conventional visual clinical data, as well as in brain activity. The patient was a 22 year old man on baseline examination that never previously wore correction for his anisometropia. After prescribing contact lens correction for the anisometropia and after 44 h of virtual reality-based vision therapy over a period of 1.5 years, the best corrected distance visual acuity (BCDVA) in the amblyopic eye improved from 0.05 to 0.5 (Sloan chart). One year after finishing the visual training, the BCDVA experienced a slight decrease to 0.4 (Sloan chart). Through the visual training, the patient gradually developed stereopsis. Likewise, changes were also detected after visual therapy on functional magnetic resonance imaging while the patient was viewing 2D and 3D stimuli. The preliminary results of this case show the potential of using virtual reality-based visual training as a treatment for adult amblyopia.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Relationship between Medium-Term Changes in Intraocular Lens Position and Refraction after Cataract Surgery with Two Different Models of Monofocal Lenses

  • Fukumitsu, Hideki
  • Camps, Vicente J.
  • Miraflores, Sara
  • Piñero, David P.
  • Camps, Vicente J.|||/items/f8e31530-eb90-4ce5-8b43-03efcddf0723
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The aim of this prospective descriptive study was to characterize the variations of the clinical effective lens position (ELP) (considering paraxial optics and postoperative data) and the intraocular lens (IOL) position, using “eye” data gathered from a 6-month follow-up of patients who underwent uneventful cataract surgery. Patients were implanted with two different monofocal IOLs: AcrySof IQ SN60WF (Alcon) (Group 1, 247 eyes) and Akreos MI60L (Bausch & Lomb) (Group 2, 104 eyes). No significant differences were found between groups concerning spherical equivalent (SE), axial length, and clinical ELP changes, from 1 to 6 months after surgery (p ≥ 0.516). A more positive change in postoperative anterior chamber depth was found in Group 2, but the difference did not reach statistical significance (p = 0.065). No significant moderate to strong correlations were found between the changes in clinical ELP and preoperative data. The correlation between the changes in SE and clinical ELP over time was strong and statistically significant (groups 1 and 2: r = 0.957 and r = 0.993, p < 0.001). In conclusion, changes in refraction from 1 to 6 months after cataract surgery, with single-piece monofocal IOLs, are not clinically relevant, which correlates with the presence of good positional stability. These changes cannot be predicted preoperatively and considered in IOL power calculations.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Clinical outcomes of presbyopia correction with the latest techniques of presbyLASIK: a systematic review

  • Fernández, Joaquín
  • Molina-Martín, Ainhoa
  • Rocha-de-Lossada, Carlos
  • Rodríguez-Vallejo, Manuel
  • Piñero, David P.
  • Molina-Martín, Ainhoa|||/items/f99932bc-d219-4bb5-aec1-ed32b00645f8
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
The aim of this study was to collect the scientific literature on the correction of presbyopia with laser in situ keratomileusis (presbyLASIK) in last years and to analyse the quality of such scientific evidence using a validated methodology for conducting a systematic review. A total of 42 articles were initially identified, but after applying the selection criteria and an additional manual search a total of 23 articles were finally included: 2 non-randomized controlled clinical trials (NRCT) and 21 case series. Quality assessment of NRCTs and case series was performed with the ROBINS-I and the 20-criterion quality appraisal checklist defined by Moga et al. (IHE Publ 2012), respectively. For NRCT, the risk of bias was moderate in one study and serious in the other NRCT, being the main sources of risk, the domains related to confounding, selection of participants and measurement of outcomes. For case series studies, the main source of risk of bias was subjects not entering the study at the same point of the conditions (different levels of presbyopia). Likewise, a significant level of uncertainty was detected for the following items: consecutive recruitment of patients, blinding of outcome assessors to the intervention that the patient received, and conclusions of the study not supported by the results. Research on presbyLASIK to this date is mainly focused on case series generating a limited level of scientific evidence. The two NRCTs identified only demonstrated the potential benefit of combining the multiaspheric profile with some level of monovision in the non-dominant eye.