Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Analysis of the relationship between the rise-time and the amplitude of single-fibre potentials in human muscles

  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
  • Gila Useros, Luis
  • Rodríguez Carreño, Ignacio
  • Malanda Trigueros, Armando
Using the core-conductor theory, a single fibre action potential (SFAP) can be expressed as the convolution of a biolectrical source and a weight function. In the Dimitrov¿Dimitrova (D¿D) SFAP convolutional model, the first temporal derivative of the intracellular action potential (IAP) is used as the source. The present work evaluates the relationship between the SFAP peak-to-peak amplitude (Vpp) and peak-topeak interval (rise-time, RT) at different fibre-to-electrode distances using simulated signals obtained by the D¿D model as well as real recordings. With a single fibre electrode, we recorded 63 sets of consecutive SFAPs from the m. tibialis anterior of four normal subjects. The needle was intentionally moved whilst recording each SFAP set. We used the observed changes in RT and Vpp within each SFAP set as a point of reference with which to evaluate how closely the relationship between RT and Vpp provided by the D¿D model reflects real data. We found that half of the recorded SFAP sets had rise-times higher than those generated by the D¿D model. We also showed the influence of the IAP spatial length on the sensitivity of RT and Vpp with radial distance. The study reveals some inaccuracies in simulated SFAPs whose origin might be related to the assumptions made in the core-conductor theory., This work was supported by the Spanish Ministry of Education and Science under the project SAF2007-65383.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Shape variability of potentials recorded by a single-fiber electrode and its effect on jitter estimation

  • Rodríguez Falces, Javier
  • Dimitrova, Nonna Alexandrovna
  • Dimitrov, George Vladimirov
  • Gila Useros, Luis
Technical problems accompanying the recording of fiber pair potentials introduce certain instability in the peak-to-peak interval (rise-time, RT) of these potentials. This study aims (1) to measure the variability observed in RT of a large number of sets of consecutive potentials recorded by a single-fiber (SF) electrode and (2) to evaluate the effect of such variability on the jitter estimation. Using a SF electrode, 140 sets of consecutive potentials were recorded from the m. tibialis anterior of four healthy subjects. For each set, the rise-time variability (RTV) was calculated as the standard deviation of the RTs of the discharges within that set. The effect of RTV in the estimation of jitter from simulated fiber pairs with controlled values of neuromuscular jitter was analyzed. The RTVs of sets visually assessed as produced by a ‘‘single-fiber’’ were always less than 20 ls, whereas those of ‘‘composite’’ sets were normally higher than 20 ls. We found that the RTV always increased the estimated jitter of fiber pairs. Such increment depended on the amount of neuromuscular jitter. The RTV provides an estimate of the possible error introduced in jitter assessment. This could be important for the diagnosis of mild clinical manifestations of myasthenia gravis, myopathies, and Duchenne dystrophies., This work was supported by the Spanish Ministry of Education and Science under the project SAF2007-65383.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Effects of changes in the shape of the intracellular action potential on the peak-to-peak ratio of single muscle fibre potentials

  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
  • Gila Useros, Luis
  • Latasa Zudaire, Iban Alexander
  • Malanda Trigueros, Armando
In situ recording of the intracellular action potential (IAP) of human muscle fibres is not yet feasible, and consequently, knowledge about certain IAP characteristics of these IAPs is still limited. The ratio between the amplitudes of the second and first phases (the so-called peak-to-peak ratio, PPR) of a single fibre action potential (SFAP) is known to be closely related to the IAP profile. The PPR of experimentally recorded SFAPs has been found to be largely independent of changes in the fibre-to-electrode (radial) distance. The main goal of this paper is to analyze the effect of changes in different aspects of the IAP spike on the relationship between PPR and radial distance. Based on this analysis, we hypothesize about the characteristics of IAPs obtained experimentally. It was found that the sensitivity of the SFAP PPR to changes in radial distance is essentially governed by the duration of the IAP spike. Assuming that, for mammals, the duration of the IAP rising phase lies within the range 0.2–0.4 ms, we tentatively suggest that the duration of the IAP spike should be over approximately 0.75 ms, with the shape of the spike strongly asymmetric. These IAP characteristics broadly coincide with those observed in mammal IAPs., This work was supported by the Spanish Ministry of Education and Science under the project SAF2007-65383.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

The peak-to-peak ratio of single-fibre potentials is little influenced by changes in the electrode positions close to the muscle fibre

  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
  • Gila Useros, Luis
  • Rodríguez Carreño, Ignacio
  • Malanda Trigueros, Armando
In a series of previous works we studied the ratio between the amplitudes of the second and first phases (the peak-to-peak ratio) of single fibre action potential (SFAPs) using the Dimitrov–Dimitrova SFAP convolutional model as a reference. From experimental potentials extracted from both healthy and diseased muscles, we determined typical peak-to-peak ratio (PPR) values and ranges for both normal and pathological conditions. In addition, we investigated the changes observed in the PPR of consecutive potentials recorded at different fibre-to-electrode distances. However, our results were not conclusive due to insufficient data. The objective of the present work was to obtain a more concrete description of the relation between PPR and radial distance. To this end, we recorded 135 sets of consecutive SFAPs from the m. tibialis anterior of four normal subjects. The needle was intentionally moved whilst recording each SFAP set. We found that PPR was largely independent of small changes in electrode position when the electrode was close to the fibre and sufficiently far from the neuromuscular and/or fibre–tendon junctions. In the discussion, we provide evidence that this result is in agreement with the generation of extracellular potentials considering the spatial extension of the intracellular action potential (IAP) along the fibre.