Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode

  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Bueno Barrachina, José Manuel
  • Rodríguez de Sanabria Gil, Rafael
[EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric dipole depth they can sense, but further experimental confirmation is needed. We aimed to develop and test a wireless multichannel ECG recording system based on a new flexible multi-ring electrode and to check the influence of CRE dimensions on the acquired signals. The system provided high-precision ECG signals by a simple procedure. The bipolar concentric ECG signal amplitude and SNR increase with the CRE¿s outer ring dimension. Differences in the signal morphologies, associated with different sensitivities to the location of the active dipoles, were also obtained in the case of diameters smaller than 34 mm. A system with several wireless sensor nodes developed could be easily used by clinical staff for non-invasive cardiac monitoring and diagnosis with high spatial and temporal resolution., Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); and by the Ministry of Economy and Competitiveness - Spain and the European Regional Development Fund (DPI2015-68397-R (MINECO/FEDER)).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position

  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Bueno Barrachina, José Manuel
  • Rodríguez de Sanabria Gil, Rafael
[EN] To overcome the limited spatial resolution of standard 12-lead ECG recordings, concentric ring electrodes (CRE) have been proposed to provide valuable data for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. Although theoretical studies indicate that the dimensions of the CRE regulate the depth of the electric dipoles sensed by these electrodes, this has not been experimentally confirmed. The aim of this work was to analyze the influence of CRE dimensions and position of a wireless multi-CRE sensor node on the cardiac signal recorded. For this, four wireless multichannel ECG recording nodes based on flexible multi-ring electrodes were placed at positions CMV1 (position comparable to V1), CMV2, CMV4R and CMV5; each node providing three bipolar concentric ECG signals (BC-ECG). Standard 12-lead ECG and 12 BC-ECG signals were recorded in 29 volunteers. The results revealed that a ring with an outer diameter of 33.5 mm achieves a balance between the ease-of-use and spatial resolution of smaller electrodes and improved detectability and higher amplitudes of signals from larger ring electrodes. Although a standard 12-lead ECG outperforms BC-ECC recordings in detectability of cardiac waves, if the relative amplitude of the wave is also considered, BC-ECG at CMV1 proved superior at picking up atrial activity. In fact, in most of the BC-ECG signals picked up at CMV1, P1 and P2 atrial activity waves were more clearly identified than in simultaneous 12-Lead ECG signals. Likewise, BC-ECG signals revealed higher spatial resolution in detecting anomalous electrical activity in local regions, such as impaired intraventricular driving, or atrioventricular blocks. Finally, the wireless multi-CRE sensor node provides enhanced comfort and handling to both patient and clinician over wired systems., Research supported in part by: a grant from the Conselleria d'Educacio, Cultura i Esport, Generalitat Valenciana Conselleria (GV/2014/029), two grants from the Universitat Politecnica de Valencia (SP20120490 and INNOVA SP20120469) and by a VLC_Campus grant (Prematuro 2013-0507)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode

  • Ye Lin, Yiyao
  • Alberola Rubio, José
  • Perales Marin, Alfredo Jose
  • Desantes, D.
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
The conduction velocity and propagation patterns of Electrohysterogram (EHG) provide fundamental information about uterine electrophysiological condition. The accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations the aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare it with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences among channels in either duration or dominant frequency in the Fast Wave High frequency range were found. Nonetheless, the high pass filtering effect of the BC-EHG records resulted in lower frequency content within the range 0.1 to 0.2 Hz than the bipolar ones. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing uterine electrophysiological condition., The authors are grateful to the Obstetrics Unit of the Hospital Universitario La Fe de Valencia (Valencia, Spain), where the recording sessions were carried out. The work was supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC2010-16945), by the Universitat Politecnica de Valencia (PAID SP20120490) and Generalitat Valenciana (GV/2014/029) and by General Electric Healthcare.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Prediction of labor onset type: Spontaneous vs induced, role of electrohysterography?

  • Alberola Rubio, José
  • Prats-Boluda, Gema
  • Desantes, D.
  • Valero, J.
  • Perales Marin, Alfredo Jose
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Background and objective: Induction of labor (IOL) is a medical procedure used to initiate uterine contractions in order to achieve delivery. IOL entails medical risks and has a significant impact on both maternal and neonatal well-being. An automatic system capable of distinguishing women who will enter labor spontaneously from those who will require late-term IOL could support clinicians and mothers in making informed decisions about prolonging pregnancy. With this aim, we developed and evaluated predictive models using not only traditional obstetrical data but also electrophysiological parameters derived from the electrohysterogram (EHG). Methods: EHG recordings were obtained from singleton term pregnancies. A set of 10 temporal and spectral parameters was calculated to characterize EHG bursts, and 6 common obstetrical parameters was also considered in the design of the predictive models. Different models were implemented based on single-layer Support Vector Machines (SVM) and on SVM ensembles using majority voting (double layer), to distinguish between two groups: term spontaneous labor (≤ 41 weeks of gestation) and late-term IOL. The areas under the receiver operating characteristic curve (AUC) of the models were compared. Results: Obstetrical and EHG parameters did not differ significantly between the two groups. Among the non-contextualized single-input SVM models, the best-performing obstetrical predictors were the Bishop score (AUC = 0.65) and gestational age at recording time (AUC = 0.68). When the EHG parameter median frequency was contextualized with these two obstetrical parameters, performance improved to an AUC of 0.76. A multiple-input SVM model using all EHG parameters achieved an AUC of 0.70. The best performance was obtained with the majority-voting SVM ensemble using contextualized EHG parameters, which reached an AUC of 0.93. Conclusions: Measuring the electrophysiological uterine condition by means of electrohysterographic recordings yielded a promising clinical decision support system for distinguishing patients that will spontaneously achieve active labor before the end of full term from those who will require late term IOL. The importance of considering these EHG measurements in the patient's individual context was also shown by combining EHG parameters with obstetrical parameters. Clinicians considering elective labor induction would benefit from this technique., General Electric Healthcare
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of a portable wireless system for bipolar concentric ECG recording

  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Bueno Barrachina, José Manuel
  • Senent, Esther
  • Rodríguez de Sanabria Gil, Rafael
[EN] Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization)., Research supported in part by: a grant from the Conselleria d'Educacio, Cultura i Esport, Generalitat Valenciana Conselleria (GV/2014/029), a grant from the Universitat Politecnica de Valencia (SP20120490) and by a VLC_Campus grant (Prematuro ID34).