Twin axial vortices generated by Fibonacci lenses

  • Calatayud Calatayud, Arnau
  • Remón Martín, Laura
  • WALTER DANIEL FURLAN
  • Ferrando, Vicente|||0000-0002-7434-7109
  • Monsoriu Serra, Juan Antonio|||0000-0003-3350-7951
Optical vortex beams, generated by Diffractive Optical Elements (DOEs), are capable of creating optical traps and other multifunctional micromanipulators for very specific tasks in the microscopic scale. Using the Fibonacci sequence, we have discovered a new family of DOEs that inherently behave as bifocal vortex lenses, and where the ratio of the two focal distances approaches the golden mean. The disctintive optical properties of these Fibonacci vortex lenses are experimentally demonstrated. We believe that the versatility and potential scalability of these lenses may allow for new applications in micro and nanophotonics., We acknowledge the financial support from Ministerio de Economia y Competitividad (grant FIS2011-23175), Generalitat Valenciana (grant PROMETEO2009-077), and Universitat Politecnica de Valencia (SP20120569), Spain. L.R. acknowledges a fellowship of "Fundacion CajaMurcia", Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Bifocal Fibonacci Diffractive Lenses

  • Monsoriu Serra, Juan Antonio|||0000-0003-3350-7951
  • Calatayud Calatayud, Arnau
  • Remón Martín, Laura
  • Furlan, Walter Daniel
  • Saavedra, G.
  • Andrés Bou, Pedro
The focusing properties of diffractive lenses designed using the Fibonacci sequence are studied. It is demonstrated that these lenses present two equal intensity foci and that the ratio of the two focal distances approaches the golden mean. This distinctive optical characteristic is experimentally confirmed. It is suggested that the versatility and potential scalability of these lenses may allow for new applications ranging from X-ray microscopy to THz imaging., This work was supported in part by the Ministerio de Economia y Competitividad under Grants FIS2011-23175 and TRA2009-0215, by the Generalitat Valenciana under Grant PROMETEO2009-077, and by the Universitat Politecnica de Valencia, Spain, under Grants PAID-05-11 and SP20120569. The work of L. Remon was supported by a fellowship of "Fundacion Cajamurcia," Spain. Corresponding author: J. A. Monsoriu (e-mail: jmonsori@fis.upv.es).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Imaging quality of multifocal intraocular lenses: automated assessment setup

  • Calatayud, Arnau
  • Remón, Laura
  • Martos, Julio
  • Furlan, Walter D.
  • Monsoriu Serra, Juan Antonio|||0000-0003-3350-7951
[EN] Purpose: A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. Methods: The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial corneas, to optimise the axial resolution in the sampling of the MTF of the MIOL under test, and different pupils, to test the dependence of the optical performance of the MIOL on the eye pupil diameter. Results: The performance and sensitivity of the apparatus is tested with different commercial MIOLs. The through-focus MTF for a refractive MIOL was measured at different moments during the process of hydration of a hydrophilic lens. Next, to show the performance of our proposal, two commercial refractive and diffractive MIOLs were evaluated. Conclusions: We have designed a precise and robust optical method for testing MIOLs in vitro. The proposed method represents a valuable technical improvement to make the procedure of MIOL evaluation more versatile, efficient and trustworthy., We acknowledge the financial support from Ministerio de Economia y Competitividad (grants FIS2011-23175 and TRA2009-0215), Generalitat Valenciana (grant PROMETEO2009-077), and Univeritat Politecnica de Valencia (INNOVA SP20120569), Spain. L.R. acknowledges a fellowship of 'Fundacion Cajamurcia', Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Effect of Fractal Contact Lenses on Peripheral Refraction in Myopic Model Eyes

  • Rodríguez Vallejo, Manuel
  • Benlloch Fornés, Josefa Isabel
  • Pons Martí, Amparo
  • Furlan, Walter Daniel
  • Monsoriu Serra, Juan Antonio|||0000-0003-3350-7951
Purpose: To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Methods: Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90–180 astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35 in steps of 5, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available contact lens designed for the same intended use: the Dual Focus (DF). Results: PRE was greater with FCL than with DF when both designs were tested for a 3.5 mm PD, and with and without decentration of the lenses. However, PRE depended on PD with both multizone lenses, with a remarkable reduction of the myopic relative effect for a PD of 5.5 mm. The myopic PRE with contact lenses decreased as the myopic refractive error increased, but this could be compensated by increasing the power of treatment zones. A peripheral myopic shift was also induced by the FCLs in the accommodated model eye. In regard to visual performance, a myopia under-correction with reference to the circle of least confusion was obtained in all cases for a 5.5 mm PD. The ghost images, generated by treatment zones of FCL, were dimmer than the ones produced with DF lens of the same power. Conclusions: FCLs produce a peripheral myopic defocus without compromising central vision in photopic conditions. FCLs have several design parameters that can be varied to obtain optimum results: lens diameter, number of zones, addition and asphericity; resulting in a very promising customized lens for the treatment of myopia progression., This research was supported by the Ministerio de Economia y Competitividad (grant FIS2011-23175), the Generalitat Valenciana (grant PROMETEO2009-077) and the Universitat Politecnica de Valencia (grant INNOVA SP20120569), Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ophthalmic: Laboratorio virtual para el diseño de nuevas lentes oftálmicas multifocales

  • Calatayud, Arnau
  • Remón, Laura
  • Monsoriu, Juan A.
  • Giménez, Fernado
  • Furlan, Walter D.
[EN] This work presents a new virtual laboratory, OPHTALMIC, developed with MATLAB GUI for using in Optics and Optometry courses as a computer tool for studying the focusing properties of multifocal diffractive both on unconventional structures both periodic and aperiodic. This virtual laboratory enables students to quickly and easily analyze the influence of the different parameters of construction and find the best solution for a user., [ES] En este trabajo presentamos un nuevo laboratorio virtual, OPHTALMIC, desarrollado en MATLAB GUI (Interfaz Gráfica de Usuario) para su uso en cursos de Óptica y Optometría como una herramienta informática para estudiar las propiedades de focalización de lentes oftálmicas multifocales basadas en estructuras no convencionales, tanto periódicas como aperiódicas. A modo de ejemplo, este laboratorio virtual permite a los estudiantes analizar rápida y fácilmente la in fluencia de los diferentes parámetros de construcción y de este modo encontrar el diseño de la lente oftálmica que más se adecue a las necesidades del usuario., Este trabajo ha sido financiado por el Ministerio de Ciencia e Innovación (FIS 2011-23175 y TRACE 2009-0215), por la Generalitat Valenciana (PROMETEO 2009-077) y por la Universitat Politècnica de València (PAID-05-11 y SP20120569). L.R. agradece a la Fundación CajaMurcia la concesión de un contrato predoctoral. Este trabajo ha sido desarrollado por los Grupos de Innovación Docente GCID35/2009 y MoMa de la Universitat de València y de la Universitat Politècnica de València, respectivamente.