Publicación Artículo científico (JournalArticle)

Visco-Hyperelastic Model with Damage for Simulating Cyclic Thermoplastic Elastomers Behavior Applied to an Industrial Component

  • Tobajas, Rafael
  • Elduque, Daniel
  • Ibarz, Elena
  • Javierre, Carlos
  • Canteli, Alfonso F.
  • Gracia, Luis
In this work a nonlinear phenomenological visco-hyperelastic model including damage consideration is developed to simulate the behavior of Santoprene 101-73 material. This type of elastomeric material is widely used in the automotive and aeronautic sectors, as it has multiple advantages. However, there are still challenges in properly analyzing the mechanical phenomena that these materials exhibit. To simulate this kind of material a lot of theories have been exposed, but none of them have been endorsed unanimously. In this paper, a new model is presented based on the literature, and on experimental data. The test samples were extracted from an air intake duct component of an automotive engine. Inelastic phenomena such as hyperelasticity, viscoelasticity and damage are considered singularly in this model, thus modifying and improving some relevant models found in the literature. Optimization algorithms were used to find out the model parameter values that lead to the best fit of the experimental curves from the tests. An adequate fitting was obtained for the experimental results of a cyclic uniaxial loading of Santoprene 101-73.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Tribological and mechanical properties of graphene nanoplatelet/PEEK composites

  • Puértolas, J.A.
  • Castro, M.
  • Morris, J.A.
  • Ríos, R.
  • Ansón-Casaos, A.
Poly(ether ether ketone) (PEEK) is a relevant thermoplastic in industry and in the biomedical sector. In this work, the lubricant capability of graphene nanoplatelets (GNPs) is used for improving the PEEK wear properties. Nanocomposites were prepared by solvent-free melt-blending and injection molding at various compositions between 1 and 10 wt. % of GNPs. The Raman G band shows a progressive increment proportional to the bulk GNP percentage. From calorimetric data, the polymer matrix structure is interpreted in terms of a 3-phase model, in which the crystalline phase fluctuates from 39 to 34% upon GNP addition. Thermal conductivity varies in accordance with the polymer crystallinity. Tensile and flexural tests show a progressive increase in the modulus, as well as a decrease in the fracture strength and the work of fracture. Most important, the composite surface undergoes a substantial improvement in hardness (60%), together with a decrease in the coefficient of friction (-38%) and a great reduction in the wear factor (-83%). Abrasion and fatigue wear mechanisms are predominant at the lowest and highest GNP concentrations respectively. In conclusion, GNPs are used without any chemical functionalization as the filler in PEEK-based materials, improving the surface hardness and the tribological properties.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of processing conditions on microstructural, mechanical and tribological properties of graphene nanoplatelet reinforced UHMWPE

  • Martínez-Morlanes, M.J.
  • Pascual, F.J.
  • Guerin, G.
  • Puértolas, J.A.
Ultra-high molecular weight polyethylene (UHMWPE) is a relevant thermoplastic in industry and a well-proven standard biomaterial in joint replacements. To enhance its tribological properties while preserving its bulk ones, composite coatings on a UHMWPE substrate were prepared using non-functionalised graphene nanoplatelet (GNP) at reinforcement concentration of 0.1–5 wt% and two mechanical mixing techniques (ball mill or blade mixer) with different consolidation temperatures of 175–240 °C. Changes in morphology and size of the UHMWPE particles before hot-pressing were observed in function of the mechanical mixing techniques applied. Wear rate was affected by graphene content, reaching a minimum at 0.5 wt% GNP, with a reduction of 20 and 15%, for ball milling and blade mixer, respectively. However, blade mixer increased the wear rate by around twice respect the ball milling results, for all the studied materials. The coefficient of friction decreased notably, by ~25%, below 3 wt% GNP content, and hardness increased by 24%, regardless of the mechanical mixing process used. Finally, consolidation temperature had a positive influence on wear rate at temperatures of around 195 °C, which could be related to the free radical scavenger effect of the GNP.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Evaluation of Cytocompatibility of PEEK-Based Composites as a Function of Manufacturing Processes

  • Gil-Albarova, Jorge
  • Martínez-Morlanes, María José
  • Fernández, José Miguel
  • Castell, Pere
  • Gracia, Luis
  • Puértolas, José Antonio
The biocompatible polymer polyetheretherketone (PEEK) is a suitable candidate to be part of potential all-polymer total joint replacements, provided its use is associated with better osseointegration, mechanical performance, and wear resistance. Seeking to meet the aforementioned requirements, respectively, we have manufactured a PEEK composite with different fillers: carbon fibers (CF), hydroxyapatite particles (HA) and graphene platelets (GNP). The mechanical outcomes of the composites with combinations of 0, 1.5, 3.0 wt% GNP, 5 and 15 wt% HA and 30% of wt% CF concentrations pointed out that one of the best filler combinations to achieve the previous objectives was 30 wt% CF, 8 wt% HA and 2 wt% of GNP. The study compares the bioactivity of human osteoblasts on this composite prepared by injection molding with that on the material manufactured by the Fused Filament Fabrication 3D additive technique. The results indicate that the surface adhesion and proliferation of human osteoblasts over time are better with the composite obtained by injection molding than that obtained by 3D printing. This result is more closely correlated with morphological parameters of the composite surface than its wettability behavior.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Influence of mechanical blending method and consolidation temperature on electrical properties of the prepared graphene nanoplatelet/UHMWPE composite

  • Puértolas, José Antonio
  • Martínez Morlanes, María José
  • Pascual, Francisco Javier
  • Morimoto, Takahiro
The high performance of ultra-high molecular weight polyethylene (UHMWPE) has led to its use in aerospace, industrial and medical applications. Reinforced with conductive fllers, it has been used to develop conductive polymer composites through the formation of a segregated structure. For assessing the infuence of processing conditions on electrical properties, coatings based on graphene nanoplatelet (GNP)/UHMWPE composites at a GNP content of 0.1 to 8 wt% were prepared, by two diferent mechanical blending methods, i.e., using a ball mill (BM) or blade mixer (BL), followed by a hot-compression process at diferent consolidation temperatures, 175 ºC or 240 ºC. Percolation thresholds at 0.5 wt% and 3.0 wt% were observed with the aforementioned mechanical techniques, respectively, with a jump in conductivity exceeding ten orders of magnitude. The use of the highest consolidation temperatures provided a decrease of the percolation threshold to 0.3 wt% in the composites prepared by ball mill, while maintain the same critical content by using the blade mixer technique. Images obtained by optical and scanning electron microscopy allowed to associate the former behavior to the diferent relative position of GNP and UHMWPE powder: the ball mill faked the GNPs onto the surface while the blade mixer embedded the GNPs into voids in the fbrillary structure. Lock-in thermography (LIT) revealed on the surface of the composite manufactured by ball milling a better distribution of the graphene and the corresponding electrical paths, compared with the composites prepared by blade mixer.