RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: Experimental study based on an agar phantom

  • Lequerica, Juan L.
  • Herrero, Maria
  • Melecio, Lemuel
  • Hornero, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 degrees C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect on the temperature measured at 2 mm from the esophageal lumen (it has a less effect on the temperature measured on the balloon surface) and (3) the pre- cooling period has a significant effect on the temperature measured on the balloon surface (the effect on the temperaturemeasured 2mmaway is small). The results were in good agreement with those obtained in a previous clinical study. The study suggests that the cooling balloon gives thermal protection to the esophagus when a minimum pre- cooling period of 2 min is programmed at a coolant temperature of 5 degrees C or less., We would like to thank the R+D+i Linguistic Assistance Office at the Technical Universityof Valencia for their help in revising this paper. This work was partially financially supported by the ‘Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica del Ministerio de Educación y Ciencia of Spain (TEC 2005-04199/TCM) and by an R&D contract (CSIC-20060633) between Edwards Life science Ltd. and the Spanish Council for ScientificResearch (CSIC).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model

  • Rodriguez, Ignacio
  • Lequerica, Juan L.
  • Herrero, Maria
  • Hornero, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature reached, and to test the characteristics of ETP as used in clinical practice. We constructed an agar phantom to model the thermal and electrical characteristics of the biological tissues (left atrium, esophagus and connective tissue). The ETP was positioned at 6.5 mm from an ablation electrode and at distances of 0, 5, 10, 15, 20 mm from the catheter axis. A thermocouple was located on the probe to measure the actual temperature of the external esophageal layer during the ablations (55 degrees C, 60 s). The mean temperatures reached at the thermocouple were significantly higher than those measured by the ETP (48.3 +/- 1.9 degrees C versus 39.6 +/- 1.1 degrees C). The temperature values measured with the ETP were significantly lower when the probe was located further from the catheter axis ( up to 2.5 degrees C lower when the distance from the probe - catheter axis was 2 cm). The dynamic calibration of the ETP showed a mean value for the time constant of 8 s. In conclusion, the temperature measured by the ETP always underestimates the temperature reached in the thermocouple. This fact can be explained by the distance gap between the thermocouple and probe and by the dynamic response of the ETP. The longer the distance between the ETP and catheter axis, the higher is the temperature difference., We would like to thank the R+D+i Linguistic Assistance Office at the Universidad Politécnica of Valencia for its help in revising this paper. This work was partially supported by the Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica del Ministerio de Educación y Ciencia of Spain (TEC 2005-04199/TCM) and by an R&D contract (CSIC-20060633) between Edwards Lifescience Ltd. and the Spanish Council for Scientific Research (CSIC).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiofrequency heating of the cornea: an engineering review of electrodes and applicators

  • Berjano, Enrique|||0000-0002-3247-2665
  • Navarro, Enrique
  • Ribera, Vicente
  • Gorris, Javier
  • Alió, Jorge L.
[EN] This paper reviews the different applicators and electrodes employed to create localized heating in the cornea by means of the application of radiofrequency (RF) currents. Thermokeratoplasty (TKP) is probably the best known of these techniques and is based on the principle that heating corneal tissue (particularly the central part of the corneal tissue, i.e. the central stroma) causes collagen to shrink, and hence changes the corneal curvature. Firstly, we point out that TKP techniques are a complex challenge from the engineering point of view, due to the fact that it is necessary to create very localized heating in a precise location (central stroma), within a narrow temperature range (from 58 to 76ºC). Secondly, we describe the different applicator designs (i.e. RF electrodes) proposed and tested to date. This review is planned from a technical point of view, i.e. the technical developments are classified and described taking into consideration technical criteria, such as energy delivery mode (monopolar versus bipolar), thermal conditions (dry versus cooled electrodes), lesion pattern (focal versus circular lesions), and application placement (surface versus intrastromal)., This work was partially supported by the Programa de Investigación y Desarrollo Tecnológico 2007 (Ref: IMIDTA/2007/586) of the Institut de la Petita i Mitjana Indústria de la Comunitat Valenciana (IMPIVA-Generalitat Valenciana), and by the "Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica del Ministerio de Educación y Ciencia" of Spain (TEC 2005-04199/TCM). We would like to thank the R+D+i Linguistic Assistance Office at the Technical University of Valencia for their help in revising this paper.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Small ablation zones created previous to saline infusion result in enlargement of the coagulated area during perfusion RF ablation: an ex vivo experimental study

  • Navarro, Ana C.
  • Burdío, Fernando
  • Güemes, Antonio
  • Burdío, José M.
  • Sousa, Ramón
  • Lozano, Ricardo
  • Tejero, Eloy
  • de Gregorio, Miguel A.
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] One of the strategies for enlarging coagulation zone dimensions during RF ablation of liver tumours is to infuse saline solutions into the tissue during ablation. The aim of this study was to evaluate experimentally whether the creation of a small coagulation adjacent to a bipolar RF applicator and prior to perfused RF ablation would allow enlargement of the coagulation zone. Thirty bipolar RF ablations (group A, n = 15; group B, n = 15) were performed in excised bovine livers. Additionally, in group B a monopolar RF application (60 W, 20 s) was performed before bipolar ablation using three small additional electrodes. Electrical parameters and dimensions of the ablation zone were compared between groups. Despite the fact that all three ablation zone diameters were greater in group B, only one of the minor diameters was significantly longer (5.52 +/- 0.66 cm versus 4.87 +/- 0.47 cm). Likewise, volume was significantly bigger in group B(100.26 +/- 24.10 cm(3) versus 79.56 +/- 15.59 cm(3)). There were no differences in the impedance evolution, allowing a relatively high constant power in both groups (around 90 W). The efficacy of delivering energy (expressed as the delivered energy per coagulation volume) was significantly better in group B, showing a lower value (578 J cm(-3) versus 752 J cm(-3)). These results suggest that the creation of small ablation zones prior to saline infusion improves the performance of this perfusion system, and hence the total volume., The authors would like to thank the R+D+i Linguistic Assistance Office at the Universidad Politécnica of Valencia for their help in revising this paper. They also thank the reviewers for their constructive comments. This work was partially supported by the Programa de Promoción de la Investigación Biomédica y en Ciencias de la Salud del Ministerio de Sanidad y Consumo of Spain (PI052498) and by the Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica del Ministerio de Educación y Ciencia of Spain (TEC 2005-04199/TCM).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Reliability assessment of a cooled intraesophageal balloon to prevent thermal injury during RF cardiac ablation: an agar phantom study

  • Lequerica, Juan L.
  • Herrero, Maria
  • Hornero, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Cooled Balloon Prevents Thermal Injury During RF Ablation. Introduction: The use of a cooled intraesophageal balloon has recently been proposed to minimize the risk of thermal injury in the esophagus during radiofrequency (RF) ablation of the left atrium. However, the capacity of this device to adequately protect the esophagus under different procedural and anatomical conditions remains unknown. Methods and Results: An agar phantom-based model was built that provided temperature readings not only on the cooled balloon (T-b) but also at a hypothetical point between the esophageal lumen and myocardium at a distance of 2 mm (T2-mm). The RF ablations were conducted considering two anatomical factors (total distance between the electrode and balloon and flow rate around the electrode) and two procedural factors (angle and pressure between the electrode and agar surface). The results show that most of the parameters studied have no significant influence on the temperature measured on the cooled balloon (T-b), the exception being a variation in the flow rate, which was found to influence the temperature. On the other hand, T2-mm was affected to a great extent by all the factors considered, the smallest influence being that of the contact pressure. The results also suggest that when an intraesophageal balloon is employed, the applied power is not a good predictor either of the temperature on the balloon or of the temperature measured at a distance 2 mm away. Conclusion: The results suggest that a cooled intraesophageal balloon provides effective thermal protection of the esophageal lumen. However, under certain circumstances, the temperature reached at a distance 2 mm away could possibly put at risk the integrity of the inner layers of the esophagus. (J Cardiovasc Electrophysiol, Vol. 19, pp. 1188-1193, November 2008)., This work was partially supported by the "Plan Nacional de Investigacion Cientifica, Desarrollo e Innovaci on Tecnologica del Ministerio de Educacion y Cienciaa of Spain (TEC 2005-04199/TCM) and by an R&D contract (CSIC-20060633) between Edwards Lifescience Ltd. and the Spanish Council for Scientific Research (CSIC).