AVANCES EN IMAGEN RADIOLOGICA

TEC2013-47270-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2013
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSIDAD CARLOS III DE MADRID
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Simplified statistical image reconstruction for X-ray CT with beam-hardening artifact compensation

  • Abella García, Mónica
  • Desco Menéndez, Manuel
  • Vaquero López, Juan José
  • Martínez Sánchez, Cristóbal
CT images are often affected by beam-hardening artifacts due to the polychromatic nature of the X-ray spectra. These artifacts appear in the image as cupping in homogeneous areas and as dark bands between dense regions, such as bones. This paper proposes a simplified statistical reconstruction method for X-ray CT based on Poisson statistics that accounts for the non-linearities caused by beam hardening. The main advantages of the proposed method over previous algorithms is that it avoids the preliminary segmentation step, which can be tricky, especially for low-dose scans, and it does not require knowledge of the whole source spectrum, which is often unknown. Each voxel attenuation is modeled as a mixture of bone and soft tissue by defining density-dependent tissue fractions, maintaining one unknown per voxel. We approximate the energy-dependent attenuation corresponding to different combinations of bone and soft tissue, so called beam-hardening function, with the 1D function corresponding to water plus two parameters that can be tuned empirically. Results on both simulated data with Poisson sinogram noise and two rodent studies acquired with the ARGUSCT system showed a beam hardening reduction (both cupping and dark bands) similar to analytical reconstruction followed by post-processing techniques, but with reduced noise and streaks in cases with low number of projections, as expected for statistical image reconstruction., This work was partially funded by NIH grants R01-HL-098686 and U01 EB018753, by Spanish Ministerio de Economia y Competitividad (projects TEC2013-47270-R and RTC-2014-3028-1) and the Spanish Ministerio de Economia, Industria y Competitividad (projects DPI2016-79075-R AEI/FEDER, UE - Agencia Estatal de Investigación and DTS17/00122 Instituto de Salud Carlos III - FIS), and co-financed by ERDF (FEDER) Funds from the European Commission, “A way of making Europe”. The CNIC is supported by the Spanish Ministerio de Economia, Industria y Competitividad and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505)., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Enabling tomography with low-cost C-arm systems

  • Abella García, Mónica
  • Molina Gómez, Claudia de
  • Ballesteros Tenrero, Nerea
  • García Santos, Alba
  • Martínez Álvaro, Alberto
  • García Barquero, Inés
  • Desco Menéndez, Manuel
In scenarios where the use of a Computed Tomography (CT) is difficult, such as during surgery or in the ICU, the use of a C-arm system to generate tomographic information could contribute with interesting additional clinical information. Recent days are seeing the development of the so-called cone-beam CT (CBCT) based on advanced motorized isocentric C-arm systems. To be able to make use of more basic C-arm systems, apart from the geometric non-idealities common to any CBCT, we need to address other difficulties. First, the trajectory of the source-detector pair may differ from a circular path and the system may suffer mechanical strains that modify the relative positions of the source and detector for different projection angles. Second, and more importantly, the exact position of the source and detector elements may not be repeatable for consecutive rotations due to low mechanical precision, thus preventing an accurate geometrical calibration of the system. Finally, the limitation of the angular span and the difficulty of obtaining a high number of projections pose a great challenge to the image reconstruction. In this work, we present a novel method to adapt a standard C-arm, originally designed for planar imaging, to be used as a tomograph. The key parts of the new acquisition protocol are (1) a geometrical calibration method to compensate mechanical inaccuracies that prevent an accurate repetition of source-detector position between acquisitions, and (2) an advanced image reconstruction method able to deal with limited angle data, sparse projections and non-circular trajectories. Both methods exploit surface information from the patient, which can be obtained using a 3D surface scanner. The proposed method was evaluated with two real C-arm systems, based on an image intensifier and a flat panel detector respectively, showing the feasibility of the proposal., This work was supported by Spanish Ministry of Economy and Competitiveness (projects TEC2013-47270-R and RTC-2014-3028-1), Spanish Ministry of Economy, Industry and Competitiveness (projects DPI2016-79075-R AEI/FEDER, UE—Agencia Estatal de Investigación and DTS17/00122 Instituto de Salud Carlos III—FIS), and co-financed by ERDF (FEDER) Funds from the European Commission, “A way of making Europe”. The CNIC is supported by the Spanish Ministry of Economy, Industry and Competitiveness and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

FUX-Sim: implementation of a fast universal simulation/reconstruction framework for X-ray systems

  • Abella García, Mónica
  • Serrano López, Estefania
  • García Blas, Francisco Javier
  • García Barquero, Inés
  • Molina Gómez, Claudia de
  • Carretero Pérez, Jesús
  • Desco Menéndez, Manuel
The availability of digital X-ray detectors, together with advances in reconstruction algorithms, creates an opportunity for bringing 3D capabilities to conventional radiology systems. The downside is that reconstruction algorithms for non-standard acquisition protocols are generally based on iterative approaches that involve a high computational burden. The development of new flexible X-ray systems could benefit from computer simulations, which may enable performance to be checked before expensive real systems are implemented. The development of simulation/reconstruction algorithms in this context poses three main difficulties. First, the algorithms deal with large data volumes and are computationally expensive, thus leading to the need for hardware and software optimizations. Second, these optimizations are limited by the high flexibility required to explore new scanning geometries, including fully configurable positioning of source and detector elements., This work was funded by the projects TEC2013-47270-R, RTC-2014-3028-1, TIN2016-79637-P, DPI2016-79075-R, and the Cardiovascular Research Network (RIC, RD12/0042/0057) from the Spanish Ministerio de Economía y Competitividad (www.mineco.gob.es/) and, FPU14/03875 grant from the Spanish Ministerio de Educación, Cultura y Deporte (http://www.mecd.gob.es). We also thank NVidia for providing the Tesla K40 device used to perform the experiments.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

XAP-Lab: A software tool for designing flexible X-ray acquisition protocols

  • Martínez, Álvaro
  • García Santos, Alba
  • Ballesteros Tenrero, Nerea
  • Desco Menéndez, Manuel
  • Abella García, Mónica
Background and Objective:the availability of digital X-ray detectors, together with the development of new robotized hardware and reconstruction algorithms, opens the opportunity to provide 3D capabilities with conventional radiology systems. This would be based on the acquisition of a limited number of projections with non-standard geometrical configurations. The versatility of these techniques is enormous, enabling the introduction of tomography in situations where a CT system is hardly available, such as during surgery or in an ICU, or in which a reduction of radiation dose is key, as in pediatrics. Computer simulations are a valuable tool to explore these possibilities before their actual implementation on real systems. Existing software tools generally simulate only standard acquisition protocols, such as cone-beam with circular trajectory, thus not allowing the users to evaluate more sophisticated projection geometries. The goal of this work is to design a simulation tool that enables the design of acquisition protocols with flexible projection geometries...., This work was supported by Spanish Ministerio de Economia y Competitividad (projects TEC2013-47270-R and RTC-2014-3028-1), Spanish Ministerio de Economia, Industria y Competitividad (projects DPI2016-79075-R AEI/FEDER, UE - Agencia Estatal de Investigación and DTS17/00122 Instituto de Salud Carlos III - FIS), and co-financed by ERDF (FEDER) Funds from the European Commission, “A way of making Europe”. The CNIC is supported by the Spanish Ministerio de Economia, Industria y Competitividad and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (SEV-2015-0505).