Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Non-enzymatic glucose sensor using mesoporous carbon screen-printed electrodes modified with cobalt phthalocyanine by phase inversion

  • González-Sánchez, María I.
  • Khadhraoui, Hanen
  • Jiménez-Pérez, Rebeca
  • Iniesta, Jesus
  • Valero, Edelmira
  • Iniesta, Jesus|||/items/9131f62f-f4a8-44bf-83be-90c9270e5d9d
The development of non-enzymatic glucose electrochemical sensors is still required to be used for the determination of glucose in complex biological media. This study presents a straightforward and remarkably efficient tool for the preparation of highly stable and sensitive glucose electrochemical sensors based on the deposition of cobalt phthalocyanine (CoPc) onto mesoporous carbon screen-printed electrodes (MCs). Results show that the MC electrochemical activation (aMC) followed by phase inversion (PI), which consisted of drop casting of CoPc in dimethylformamide onto a wetting electrolyte leading to the electrode aMC-CoPc/PI, enhanced sensitivity towards glucose determination in complex media. The beneficial need for MC surface activation and PI has been explored by scanning electron microscopy, energy dispersive X-ray spectroscopy, Raman spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The aMC-CoPc/PI electrode exhibited the highest electrocatalytic activity of the series (namely, MC-CoPc, MC-CoPc/PI and aMC-CoPc) towards glucose oxidation. By using square wave voltammetry technique, the aMC-CoPc/PI glucose electrochemical sensor demonstrated a sensitivity of 22.3 µA mM−1 and a low detection limit of 27.4 µM (S/N = 3) in a linear dynamic range of 0.1 to 3.5 mM. Additionally, it also displayed high selectivity, robust stability, repeatability and reproducibility toward the quantification of glucose concentration in complex samples such as horse serum, intravenous glucose saline solution and culture medium for sperm cells.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Highly sensitive ammonia sensing at room temperature with Ce/Pr mixed oxide/oxidized MWCNT composite

  • Aguirre-Cortés, Jhon Mauricio
  • Villa-Díaz, Miriam
  • Baeza-Romero, María Teresa
  • Solla-Gullón, José
  • Valero, Edelmira
  • Solla-Gullón, José|||/items/59027465-51a1-4647-8345-0b316b59de48
Ammonia is a hazardous atmospheric pollutant of major industrial relevance, yet reliable room-temperature (RT) detection in real conditions remains challenging for conventional metal-oxide sensors due to high operating temperatures, poor sensitivity and selectivity, humidity effects and limited real air validation. Herein, we report a chemiresistive NH3 gas sensor based on a Ce/Pr mixed oxide nanocomposite with oxidized multi-walled carbon nanotubes. The sensing layer, deposited by a simple and cost-effective airbrush spray-coating technique and thoroughly structurally and morphologically characterized, exhibits superior detection performance at RT. In real air at 40% relative humidity and RT, the sensor exhibits an exceptionally strong and low-noise response of 7.1% to just 200 ppb NH3, whereas the mixed oxide alone showed no detectable signal below 10 ppm. Furthermore, the device achieves an ultra-low detection limit of ∼60 ppb and an unusually broad linear range of more than three orders of magnitude (0.2–500 ppm), supported by 32 concentration points. Notably, the sensor response remains stable across a wide relative humidity range (35% to 70%) and displays excellent operational stability by retaining a reproducible signal over 240 consecutive measurements in real air. Selectivity tests demonstrated negligible cross-sensitivity to common gases (CH4, CO, CO2, H2) and representative volatile organic compounds. Importantly, equivalent response amplitudes were obtained when alternating between real and synthetic air, which underscores the sensor’s reliability in real environments. Overall, these results establish this hybrid material as a robust and highly sensitive platform for sub-ppm ammonia detection in challenging samples such as air and breath.