RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation

  • Vraka, Aikaterini
  • Moreno-Arribas, José
  • Gracia-Baena, Juan M.
  • Hornero, Fernando
  • Alcaraz, Raúl
  • Rieta, J J
[EN] Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves' features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6-1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended., This research received partial financial support from public grants DPI2017-83952-C3, PID2021-00X128525-IV0, PID2021-123804OB-I00. and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SB-PLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha. and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Dissimilar Impact in Atrial Substrate Modification of Left and Right Pulmonary Veins Isolation after Catheter Ablation of Paroxysmal Atrial Fibrillation

  • Vraka, Aikaterini
  • Bertomeu-González, Vicente
  • Fácila, Lorenzo
  • Moreno-Arribas, José
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Since the discovery of pulmonary veins (PVs) as foci of atrial fibrillation (AF), the commonest cardiac arrhythmia, investigation revolves around PVs catheter ablation (CA) results. Notwith-standing, CA process itself is rather neglected. We aim to decompose crucial CA steps: coronary sinus (CS) catheterization and the impact of left and right PVs isolation (LPVI, RPVI), separately. We recruited 40 paroxysmal AF patients undergoing first-time CA and obtained five-minute lead II and bipolar CS recordings during sinus rhythm (SR) before CA (B), after LPVI (L) and after RPVI (R). Among others, duration, amplitude and atrial-rate variability (ARV) were calculated for P-waves and CS local activation waves (LAWs). LAWs features were compared among CS channels for reliability analysis. P-waves and LAWs features were compared after each ablation step (B, L, R). CS channels: amplitude and area were different between distal/medial (p <= 0.0014) and distal/mid-proximal channels (p <= 0.0025). Medial and distal showed the most and least coherent values, respectively. Correlation was higher in proximal (>= 93%) than distal (<= 91%) areas. P-waves: duration was significantly shortened after LPVI (after L: p = 0.0012, -13.30%). LAWs: insignificant variations. ARV modification was more prominent in LAWs (L: >+73.12%, p <= 0.0480, R: <-33.94%, p <= 0.0642). Medial/mid-proximal channels are recommended during SR. CS LAWs are not significantly affected by CA but they describe more precisely CA-induced ARV modifications. LPVI provokes the highest impact in paroxysmal AF CA, significantly modifying P-wave duration., This research has received partial financial support from public grants DPI2017-83952-C3, PID2021-00X128525-IV0, PID2021-123804OB-I00 and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Relevance of Calibration in Machine Learning-Based Hypertension Risk Assessment Combining Photoplethysmography and Electrocardiography

  • Cano, Jesús
  • Fácila, Lorenzo
  • Gracia-Baena, Juan M.
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] The detection of hypertension (HT) is of great importance for the early diagnosis of cardiovascular diseases (CVDs), as subjects with high blood pressure (BP) are asymptomatic until advanced stages of the disease. The present study proposes a classification model to discriminate between normotensive (NTS) and hypertensive (HTS) subjects employing electrocardiographic (ECG) and photoplethysmographic (PPG) recordings as an alternative to traditional cuff-based methods. A total of 913 ECG, PPG and BP recordings from 69 subjects were analyzed. Then, signal preprocessing, fiducial points extraction and feature selection were performed, providing 17 discriminatory features, such as pulse arrival and transit times, that fed machine-learning-based classifiers. The main innovation proposed in this research uncovers the relevance of previous calibration to obtain accurate HT risk assessment. This aspect has been assessed using both close and distant time test measurements with respect to calibration. The k-nearest neighbors-classifier provided the best outcomes with an accuracy for new subjects before calibration of 51.48%. The inclusion of just one calibration measurement into the model improved classification accuracy by 30%, reaching gradually more than 96% with more than six calibration measurements. Accuracy decreased with distance to calibration, but remained outstanding even days after calibration. Thus, the use of PPG and ECG recordings combined with previous subject calibration can significantly improve discrimination between NTS and HTS individuals. This strategy could be implemented in wearable devices for HT risk assessment as well as to prevent CVDs., This research received financial support from grants PID2021-00X128525-IV0, PID2021123804OB-I00 and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.