Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Dual-stage control strategy for a three-level neutral point clamped converter with selective harmonic mitigation PWM

  • Rosado Galparsoro, Leyre
  • Norambuena, Margarita
  • Samanes Pascual, Javier
  • Lezana, Pablo
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
Grid-connected converters must meet the requirements imposed by grid codes, such as harmonic emission limits and grid voltage support during voltage dips. Selective harmonic mitigation pulsewidth modulation (SHMPWM) is a very interesting technique for high power converters to meet the maximum harmonic emission levels, while keeping a low switching frequency. However, the combination of this modulation with a proportional integral (PI) controller requires slow dynamics, which makes it difficult to comply with the dynamic response requirements of grid codes. As an alternative, model predictive control (MPC) offers a very fast dynamic response, but a wide spread harmonic spectrum in steady state. Thus, the combination of MPC with a PI controller with SHMPWM is advantageous. In this work, a dual-stage control strategy is implemented. During transients, finite control set MPC (FCS-MPC) is activated to rapidly drive the current to the desired reference, while in steady state, the PI controller with SHMPWM is used. Therefore, the dual-stage control strategy allows to comply with the two requirements of grid codes, becoming a suitable strategy for grid-connected converters., This work is part of the projects PID2019-110956RB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It has also been partially supported by Ingeteam Power Technology and the Public University of Navarre. The authors also acknowledge the support of ANID through projects FB0008 Advanced Center for Electrical and Electronics Engineering, FONDECYT 1230250.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Dual-active-bridge modeling for electric vehicle charging stations including variable output cable inductance

  • Galdeano Bujanda, Mikel
  • Barrios Rípodas, Ernesto
  • Elizondo Martínez, David
  • Sanchis Gúrpide, Pablo
This paper proposes a simplified yet accurate small-signal model for dual-active-bridge (DAB) converters that enables straightforward controller design for EV charger applications. The model accounts for all relevant elements of the charging system, including parasitic inductances and resistances, while preserving a compact formulation suitable for control. By systematically linearizing the system dynamics using a small-signal model, precise transfer functions are obtained, each exhibiting different gains depending on the operating power and the control objective (voltage or current regulation). The main contribution of this work lies in the inclusion of charging cable inductance and battery resistance variations in the modeling framework, enabling worst-case Bode analysis for the design of robust control loops. This provides designers with a practical tool that balances accuracy and simplicity, ensuring reliable control performance in electric vehicle charging systems, as validated by simulation results., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00 funded by MICIU/AEI /10.13039/501100011033, by ERDF/EU and by the European Union NextGenerationEU/PRTR. It has also been supported by Ingeteam Power Technology. Mikel Galdeano was supported by a predoctoral contract from the Public University of Navarre (Spain).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Deadbeat voltage control for a grid-forming power converter with LCL filter

  • Samanes Pascual, Javier
  • Rosado Galparsoro, Leyre
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Pérez, Marcelo A.
Grid-forming power converters are controlled as voltage sources to regulate the grid voltage and frequency. These converters can increase power system strength if they impose a voltage waveform resilient to grid transients. For this reason, in this paper, we propose a deadbeat control strategy of the capacitor voltage for high power converters with LCL filter. To damp the LCL resonant poles, an active damping strategy is developed, based on a modification of the deadbeat control law. With this purpose, a notch filter is applied to the electrical variables allowing to emulate different damping resistances for the fundamental component and the harmonics. As a result, the active damping does not introduce tracking errors of the fundamental frequency component, while it provides damping to the filter resonance. The proposed strategy does not require knowledge of the grid impedance, an interesting feature in grid-connected power converters because the grid impedance is generally unknown. Experimental results validate the proposed strategy., This work was supported in part by Spanish State Research Agency (AEI) under Grants PID2019-110956RB-I00 /AEI/ 10.13039 and TED2021-132604B-I00, in part by the Spanish Ministry of Universities through “Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i, Subprograma Estatal de Movilidad, del Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020” Program, in part by the Advanced Center for Electrical and Electronics Engineering (AC3E) under Grant ANID/FB0008, in part by Solar Energy Research Center (SERC) under Grant ANID/FONDAP/15110019, and in part by the ANID/Fondecyt under Regular Grant 1211826.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Negative sequence cancellation in DFIGs via independently controlled dynamic braking resistors

  • Baum, Filip
  • López Taberna, Jesús
  • Samanes Pascual, Javier
  • Bauer, Jan
This paper extends the concept of using dynamic braking resistors (DBRs) in series with the stator of doubly-fed induction generators (DFIGs) to improve low-voltage ride-through (LVRT) performance, specifically under asymmetrical grid faults. Although previous studies have demonstrated the effectiveness of fixed or discrete-valued DBRs in mitigating electrical transients, mechanical issues such as torque loss remain mostly underexplored. In this work, we leverage independent control of the resistance in each stator phase by means of pulse-width modulation to maintain generator torque and cancel the negative sequence component of the grid voltage. By shaping the DBR voltage drop through asymmetric resistances, the resulting negative sequence voltage opposes that of the grid, reducing torque oscillations and enabling more stable DFIG operation during unbalanced faults. Analytical derivations and simulation results validate the proposed control strategy., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MICIU/AEI /10.13039/501100011033, by ERDF/UE and by the European Union NextGeneration EU/PRTR and supported by the Student Grant Competition of the Czech Technical University in Prague under Grant SGS25/140/OHK3/3T/13.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Passivity analysis in power electronic converters with SHE modulation

  • Ramos Arocena, Naroa
  • Pascual Iglesias, Iñigo
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Samanes Pascual, Javier
To ensure the stability of modern power grids, particularly those dominated by power electronics, it is convenient for grid-connected converters to exhibit passivity across the entire frequency spectrum. Furthermore, it is interesting not only for the system to be passive, that is, for the converter system's resistance to be positive, but also for this resistance to have a high value, as it helps dampen potential grid resonances. This article presents a study of a grid-connected converter, achieving passivity and increasing the converter's resistance through control strategies. Given the growing use of Selective Harmonic Elimination (SHE) modulation techniques in high-power converters, the analysis will also focus on how to assess the passivity of a system employing these modulation techniques., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MICIU/AEI/10.13039/501100011033, by ERDF/UE and by the European Union NextGenerationEU/PRTR. It has also been partially supported by Ingeteam Power Technology and the Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Active damping strategies for mitigating resonances in offshore wind farms: a comparative study of PWM and SHEPWM

  • Pascual Iglesias, Iñigo
  • Ramos Arocena, Naroa
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
  • Samanes Pascual, Javier
This paper presents an active damping strategy to mitigate resonances in offshore wind farms caused by the parasitic capacitance of submarine cables, which challenge system stability and grid code compliance. The proposed method emulates a virtual impedance damping the wide range of resonances that appear in offshore wind farms, depending on its configuration and number of turbines connected. Its effectiveness is evaluated for two modulation techniques: PWM and selective harmonic elimination PWM. PWM generates predictable harmonic content outside the resonance range, enabling robust damping of resonances. In contrast, selective harmonic elimination PWM¿though optimized to eliminate the harmonics in the resonance frequency range¿introduces distortion in this range due to modulation-control interactions in closed-loop operation. This distortion demands excessive corrective action from the AD, limiting its practicality. The strategy and its results are validated through simulation., This work is part of the project PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033, by the FSE+, by ERDF/UE and by the European Union NextGenerationEU/PRTR. The authors want to acknowledge Ingeteam Power Technology for its financial and ongoing support.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Torque preservation in DFIG systems during voltage dips with modulated stator-connected dynamic braking resistor

  • Baum, Filip
  • López Taberna, Jesús
  • Samanes Pascual, Javier
  • Bauer, Jan
This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MICIU/AEI /10.13039/501100011033, by ERDF/UE and by the European Union NextGenerationEU/PRTR.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Asymmetrical firing angle modulation for 12-pulse thyristor rectifiers supplying high-power electrolyzers

  • Iribarren Zabalegui, Álvaro
  • Barrios Rípodas, Ernesto
  • Elizondo Martínez, David
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
This paper presents an asymmetrical firing angle modulation strategy for 12-pulse thyristor rectifiers aimed at supplying high-power electrolyzers, which allows to reduce the size of the passive filter and the static compensator (STATCOM) required to comply with grid harmonic regulations and achieve unity power factor. Usually, 12-pulse thyristor rectifiers follow a symmetric modulation strategy in which the same firing angle is applied to both 6-pulse bridges. In this case, large passive ac-side inductances are required to reduce grid current harmonics, which increase the reactive power consumption and thus the required STATCOM size. However, this paper demonstrates that by applying different firing angles to the two 6-pulse bridges it is possible to comply with the harmonic regulation limits using smaller filtering inductances and therefore reducing the STATCOM size. The methodology to find the optimal firing angle values that should be applied in order to minimize the filtering inductance and the STATCOM size for a given electrolyzer is explained. This strategy is validated by simulation, and results show that the required filtering inductance and the apparent power of the STATCOM can be effectively reduced by 62% and 31%, respectively, using this asymmetrical firing angle modulation., This work is part of the projects PID2019-110956RB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It has also been supported by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

SiC MOSFET turn-off overvoltage measurement

  • Galdeano Bujanda, Mikel
  • Barrios Rípodas, Ernesto
  • Elizondo Martínez, David
  • Sanchis Gúrpide, Pablo
Selecting the appropriate measurement system is crucial in power electronics. This is especially important during MOSFET's turn-off process, where it is essential to measure the voltage rise and accurately capture the peak overvoltage. During turn-off, the interaction between the MOSFET and the parasitic element of the PCB creates a resonance. This phenomenon leads to an overvoltage, which peaks at the resonance frequency and can potentially damage the device. This paper discusses the characteristics of the measurement system needed to capture the peak overvoltage accurately. A step-by-step guide is proposed to ensure the correct selection of the probe and its correct use. This guide is experimentally validated on a three-level converter, where drain-source voltage measurements have been performed with and without a ground reference. The drain to source measurement method proposed in this paper is accurate, costeffective and capable of minimizing induced noise., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00 funded by MICIU/AEI /10.13039/501100011033, by ERDF/EU and by the European Union NextGenerationEU/PRTR. It has also been supported by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Novel two-stage three-level converter with inherently-balanced dc voltage for EV fast-charging applications

  • Elizondo Martínez, David
  • Barrios Rípodas, Ernesto
  • Galdeano Bujanda, Mikel
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The design of EV fast chargers faces a new challenge due to the boost in the battery voltage of electric cars and heavyduty electric vehicles. Two-stage converters, that consist of an isolated dc-dc stage and an extra regulated dc-dc converter, are attracting an increasing attention thanks to their outstanding performance. The potential benefits of multilevel converters, such as lower power losses and more compact filters, can be incorporated to two-stage architectures at the expense of simplicity due to the need of a voltage balancing method. In this article, a novel dc-dc two-stage three-level (2S3L) architecture is presented, which guarantees that the multilevel input dc voltages are balanced without any specific balancing technique or extra components. Moreover, it accomplishes lossless switching in the isolated dc-dc stage, enabling a high efficiency. A 15 kW test bench is built in order to experimentally verify the inherentlybalanced voltages. The experimental tests demonstrate that the dc-link voltages are inherently-balanced (no control needed) in both transient and steady states, and that it is robust against tolerances and faulty operation. The test bench is able to provide a wide output voltage, from 200 to 900 V, and reaches a high peak efficiency of 98.2% at rated power., This work is part of the projects PID2019-110956RB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It was also been supported by the Public University of Navarre (UPNA) under a postdoctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Modeling of the steady-state ac current fluctuation in two-stage electric car fast chargers based on solid-state transformers

  • Elizondo Martínez, David
  • Barrios Rípodas, Ernesto
  • Sanchis Gúrpide, Pablo
Two-stage conversion structures are increasingly attracting attention, particularly for electric vehicles fast charging, and those based on a solid-state transformer (SST) and with a postregulator stand out. As a consequence of this postregulator, there is a steady-state fluctuation in the ac current of the SST, which turns into a greater rms current value that can impact on the converter performance. Hence, an analytical formula of this fluctuation should be considered during the design process. This work proposes a model for two different conversion structures (two-level and three-level), which is validated through simulations. The design process can be benefited from implementing the presented model, as it shows the interactions between the two power conversion stages and allows accomplishing a limited current fluctuation in the SST while avoiding more expensive and bulkier dc-link capacitors than necessary., This work is partially funded by UPNA, and is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MICIU/AEI /10.13039/501100011033, by ERDF/UE and by the European Union NextGenerationEU/PRTR.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Selective harmonic mitigation: limitations of classical control strategies and benefits of model predictive control

  • Rosado Galparsoro, Leyre
  • Samanes Pascual, Javier
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
Selective harmonic mitigation pulsewidth modulation (SHMPWM) combined with model predictive control (MPC) is a promising approach for grid-connected power converters. SHMPWM can guarantee grid code compliance in steady state, e.g. grid harmonic injection, with a reduced output converter filter, while MPC improves dynamic response and allows grid code compliance in the event of grid transients. This paper presents a survey of the MPC strategies already published in the literature developed for their use with SHMPWM. The existing strategies fall into two categories: direct model predictive control with an implicit selective harmonic mitigation modulator, and direct model predictive control based on finite control set (FCS-MPC). One representative control strategy of each group is compared to each other and to the performance of classical proportional- integral (PI) controllers combined with SHMPWM. The goal is to identify the potential benefits of MPC for grid-connected power converters, and determine the main advantages and limitations of the two selected state-of-the-art control strategies. Their performance is assessed through Hardware-in-the-Loop (HIL) experimental results in terms of real-time implementation, harmonic content grid code compliance, dynamic response and performance under grid transients., This work is part of the projects PID2019-110956RB-I00 and TED2021- 132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It has also been partially supported by Ingeteam Power Technology and the Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Turn-off overvoltage in SiC power electronic converters

  • Galdeano Bujanda, Mikel
  • Barrios Rípodas, Ernesto
  • Elizondo Martínez, David
  • Sanchis Gúrpide, Pablo
In power electronics converters, understanding the semiconductor turn-off process is key. During turn-off, the semiconductor withstands the bus voltage plus the overvoltage produced in the parasitic inductances and due to the di/dt in the turn-off. In SiC MOSFET turn-off, this overvoltage is critical since these devices operate with higher di/dt and can be operated with blocking voltage close to their breakdown voltage. In this paper, a simple equation-based procedure that allows for an accurate overvoltage calculation in SiC MOSFET turn-off is presented. The proposed step-by-step procedure is applied to calculate the overvoltage during the turn-off of the SiC module CAB016M12FM3 for different gate resistors and switched currents. This analysis can be used to select the correct value of the gate resistor. The obtained results are validated by comparison with LTspice simulation results., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00 funded by MICIU/AEI /10.13039/501100011033, by ERDF/EU and by the European Union NextGenerationEU/PRTR. It has also been supported by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Influence of the grid-side converter synchronization loop on the small-signal stability of a grid-forming DFIG wind turbine

  • Samanes Pascual, Javier
  • Oraa Iribarren, Iker
  • Gubía Villabona, Eugenio
  • López Taberna, Jesús
In grid-forming mode (GFM) doubly-fed induction generator based wind turbines connected to the grid, the converter connected to the rotor side is normally responsible for providing the grid-forming characteristics, while the grid-side converter commonly controls the DC-bus voltage thanks to a current control loop implemented in a rotating reference frame. The angle for the rotating reference frame is obtained by means of a phase-locked loop, which synchronizes the converter with the grid. However, this synchronization loop can introduce stability problems in weak grids. This paper proposes to synchronize the grid-side converter by means of the power synchronization loop of the GFM control of the rotor-side converter. This eliminates the need to use of a specific phase-locked loop, improving small-signal stability as demonstrated in the small-signal stability analysis performed in this paper., This work is part of the Projects PID2022-142791OB-I00 and TED2021-132604B-I00, funded by MICIU/AEI /10.13039/501100011033, by ERDF/UE and by the European Union NextGenerationEU/PRTR. It has also been supported by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Contribución de congreso (ConferenceOutput)

Small-signal stability analysis of power converters with optimal pulsewidth modulation strategies

  • Rosado Galparsoro, Leyre
  • Samanes Pascual, Javier
  • López Taberna, Jesús
  • Gubía Villabona, Eugenio
Optimal pulsewidth modulation strategies are commonly used in power electronics applications with closed-loop controllers. However, there is a lack of specific studies in the literature that analyze and study the dynamics of these modulators, which makes it difficult to derive small-signal models for stability analysis and controller design. Moreover, in many studies, the influence of optimal pulsewidth modulation on the small-signal stability analysis is disregarded. This article addresses these issues by proposing a modeling methodology for optimal pulsewidth modulators, applied to a selective harmonic elimination modulator. The proposed methodology is based on the frequency response analysis, which is particularly convenient for controller design. The study shows that the classical zero-order hold model employed for carrier-based pulsewidth modulators is valid for characterizing the dynamics of optimal pulse-width modulation strategies. Simulation results validate this conclusion., This work is part of the projects PID2019-110956RB-I00 and TED2021-132604B-I00, funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. It has also been partially supported by Ingeteam Power Technology and the Public University of Navarre.