Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Numerical Framework for Deep Learning Photoacoustics Image Reconstruction

  • G. Muñoz, Javier
  • Ariza-Carrasco, Alejandro
  • Cruza, Jorge F.
  • Elvira Segura, Luis
  • Camacho Sosa-Días, Jorge
  • Udías, José M.
  • Alonso de Laciñana, María
  • Rodriguez-Pardo, Jorge
  • Ibáñez García, Paula
  • Pérez-Liva, Mailyn
Forum Acusticum / Euronoise 2025, the 11th EAA Annual European Conference on Acoustics and Noise Control Engineering, joint with the XLVI Spanish Acoustic Conference TECNIACUSTICA 2025, June 23rd to 26th 2025, Málaga (Spain) 4 páginas, 2 figuras, Photoacoustic Imaging (PAI) combines optical excitation with ultrasound detection to produce high-quality molec- ular images of intact biological tissues. Conventional sys- tems rely on Class IV [1] pulsed lasers, which limits clin- ical translation. This work explores the use of pulsed semiconductor diodes for their portability, versatility, and low-cost. However, their lower peak power decreases PAI signal amplitude. Implementing deep learning techniques trained with realistic synthetic data is a promising tech- nique to increase PAI image quality [2]. Here we create a framework which simulates real scenarios taking into account acoustics and optical properties, ultrasound trans- ducer characteristics and fiber bundles features, crucial to optimize reconstruction performance with a Neural Net- work. The simulated experimental setup included an ar- ray of optical fibers connected to semiconductor diodes parallel to a 128-element transducer array which registers the signal generated by the absorbed light. Optical proper- ties were simulated in MCX Monte Carlo software using GPU parallelization. k-Wave software was used for acous- tic simulations and Time-Reversal (TR) image reconstruc- tion. Finally, a Neural Network model implemented using Tensorflow enhanced the reconstruction, recovering up to 3 cm depth and 200 μm of resolution, delivering excep- tional vascular imaging quality., This work received support from the European Union’s Horizon 2020 research and Innovation Pro- gramme under the Marie Sklodowska-Curie Grant Agreement no.101030046, and the Programme Ram´on y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/501100011033 and by the Eu- ropean Union ”NextGenerationEU”/PRTR”. Also, we acknowledge support from grants FASCINA (PID2021- 126998OB-I00/), 3PET (PDC2022-133057-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/10.13039/501100011033/Uni´on Europea Next GenerationEU/PRTR, Prototwin Project (TED2021-349 130592B-I00) and Tecnolog´ıas Avanzadas para la Ex- ploraci´on del Universo y sus Componentes” (PR47/21 TAU-CM TAU- PRTR), funded by EU Resilient and NextGeneration funds. This work was supported by Knowledge Generation Projects 2022 Type A Ori- ented Research, Government of Spain INVENTOR (PID2022-137114OA-I00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Numerical Framework for Deep Learning Photoacoustics Image Reconstruction

  • G. Muñoz, Javier
  • Ariza-Carrasco, Alejandro
  • Díaz Cañadas, Bárbara
  • Cruza, Jorge F.
  • Elvira Segura, Luis
  • Camacho Sosa-Días, Jorge
  • L. Herraiz, Joaquín
  • Udías, José M.
  • Bertolet Reina, Alejandro
  • Alonso de Laciñana Cases, María
  • Rodriguez-Pardo, Jorge
  • Mariño Trillo, Eduardo
  • Laso García, Fernando
  • Ibáñez García, Paula
  • Pérez-Liva, Mailyn
23rd IEEE International Symposium on Biomedical Imaging, ISBI 2026, 08-11 April 2026, London, UK. 4 páginas, 3 figuras., Photoacoustic imaging (PAI) combines pulsed optical excitation with ultrasound detection to produce high-contrast molecular and structural images of biological tissues. Conventional PAI systems rely on high-energy pulsed lasers that, despite their excellent performance, remain bulky, costly, and constrained by strict safety requirements, limiting their clinical translation. This work explores the use of pulsed semiconductor diodes as a compact, low-cost, and portable alternative. Although these sources exhibit lower peak power and reduced fluence, advanced computational approaches can compensate for these limitations. We present a numerical framework that integrates realistic optical and acoustic simulations with deep learning reconstruction to enhance image quality under low-fluence conditions. The framework accounts for light propagation, transducer response, and acoustic field effects to generate training datasets that accurately represent experimental conditions. The proposed hybrid reconstruction recovers fine vascular structures up to 3 cm in depth with 200μ m spatial resolution, demonstrating the potential of diode-based PAI systems for affordable and viable PAI., This work received support from: Programme Ramón y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/ 501100011033 and by the European Union “NextGenerationEU”/PRTR”; FASCINA (PID2021-126998OB-I00/), 3PET (PDC2022-133057-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/10.13039/501100011033/ Unión Europea Next GenerationEU/PRTR, Prototwin Project (TED2021-349 130592B-I00) and Tecnologías Avanzadas para la Exploración del Universo y sus Componentes” (PR47/21 TAU-CM TAU- PRTR), funded by EU Resilient and NextGeneration funds; INVENTOR (PID2022-137114OA-I00);project LUNABRAIN-CM (TEC-2024/TEC-43), funded with € 1.026 million by the Comunidad de Madrid through the RD activities program in technologies, granted by Order 5696/2024., Peer reviewed