EXPLORACION IN VIVO DE LA RESPUESTA TISULAR A LA RADIACION

PID2022-137114OA-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 16
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Real-time dose reconstruction in proton therapy from in-beam PET measurements

  • Valladolid Onecha, Víctor
  • Espinosa Rodríguez, Andrea
  • Soneira-Landín, C.
  • Arias Valcayo, Fernando
  • Gaitán-Dominguez, S.
  • Martínez Nouvilas, Víctor
  • García Díez, Marcos
  • Ibáñez García, Paula Beatriz
  • España, S.
  • Sánchez Parcerisa, Daniel
  • Cerrón-Campoo, F.
  • Vera-Sánchez, J. A.
  • Mazal, A.
  • Udías Moinelo, José Manuel
  • Fraile Prieto, Luis Mario
Objective. Clinical implementation of in-beam positron emission tomography (PET) monitoring in proton therapy (PT) requires the integration of an online fast and reliable dose calculation engine. This manuscript reports on the achievement of real-time reconstruction of 3D dose and activity maps with proton range verification from experimental in-beam PET measurements. Approach. Several cylindrical homogeneous PMMA phantoms were irradiated with a monoenergetic 70 MeV proton beam in a clinical facility. Additionally, PMMA range-shifting foils of varying thicknesses were placed at the proximal surface of the phantom to investigate range shift prediction capabilities. PET activity was measured using a state-of-the-art in-house developed six-module PET scanner equipped with online PET reconstruction capabilities. For real-time dose estimation, we integrated this system with an in-beam dose estimation algorithm, which combines a graphical processing unit-based 3D reconstruction algorithm with a dictionary-based software, capable of estimating deposited doses from the 3D PET activity images. The range shift prediction performance has been quantitatively studied in terms of the minimum dose to be delivered and the maximum acquisition time. Main results. With this framework, 3D dose maps were accurately reconstructed and displayed with a delay as short as one second. For a dose fraction of 8.4 Gy at the Bragg peak maximum, range shifts as small as 1 mm could be detected. The quantitative analysis shows that accumulating 20 s of statistics from the start of the irradiation, doses down to 1 Gy could be estimated online with total uncertainties smaller than 2 mm. Significance. The hardware and software combination employed in this work can deliver dose maps and accurately predict range shifts after short acquisition times and small doses, suggesting that real-time monitoring and dose reconstruction during PT are within reach. Future work will focus on testing the methodology in more complex clinical scenarios and on upgrading the PET prototype for increased sensitivity.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Dual photoacoustic/ultrasound technologies for preclinical research: current status and future trends

  • Pérez-Liva, Mailyn
  • Alonso de Leciñana, María
  • Gutiérrez-Fernández, María
  • Camacho Sosa-Días, Jorge
  • Fernández Cruza, Jorge
  • Rodríguez-Pardo, Jorge
  • García-Suárez, Iván
  • Laso-García, Fernando
  • L. Herraiz, Joaquín
  • Elvira Segura, Luis
30 páginas, 6 figuras, 2 tablas., Photoacoustic (PA) imaging, by integrating optical and ultrasound (US) modalities, combines high spatial resolution with deep tissue penetration, making it a transformative tool in biomedical research. This review presents a comprehensive analysis of the current status of dual PA/US imaging technologies, emphasising their applications in preclinical research. It details advancements in light excitation strategies, including tomographic and microscopic modalities, innovations in pulsed laser and alternative light sources, and US instrumentation. The review further explores preclinical methodologies, encompassing dedicated instrumentation, signal processing, and data analysis techniques essential for PA/US systems. Key applications discussed include the visualisation of blood vessels, micro-circulation, and tissue perfusion; diagnosis and monitoring of inflammation; evaluation of infections, atherosclerosis, burn injuries, healing, and scar formation; assessment of liver and renal diseases; monitoring of epilepsy and neurodegenerative conditions; studies on brain disorders and preeclampsia; cell therapy monitoring; and tumour detection, staging, and recurrence monitoring. Challenges related to imaging depth, resolution, cost, and the translation of contrast agents to clinical practice are analysed, alongside advancements in high-speed acquisition, artificial intelligence-driven reconstruction, and innovative light-delivery methods. While clinical translation remains complex, this review underscores the crucial role of preclinical studies in unravelling fundamental biomedical questions and assessing novel imaging strategies. Ultimately, this review delves into the future trends of dual PA/US imaging, highlighting its potential to bridge preclinical discoveries with clinical applications and drive advances in diagnostics, therapeutic monitoring, and personalised medicine., The work of Mailyn Pérez-Liva was supported in part by the Program Ramón y Cajal under Grant RYC2021-032739-I, MCIN/AEI/10.13039/501100011033, by the European Union ‘NextGenerationEU’/PRTR and by INVENTOR PID2022-137114OA-I00. Joaquin L Herraiz acknowledges support from TED2021-130592B-I00 funded by MCIN/AEI/10.13039/501100011033 and TARTAGLIA MIA.2021.M02.0005, funded by the Spanish Ministry of EADT, with funds nextGenerationEU/PRTR. Luis Elvira was supported by PID2022-138013OB-I00/ AEI/10.13039/501100011033/FEDER. María Gutiérrez-Fernández was supported by the Program Miguel Servet under Grant CPII20/00002, Carlos III Health Institute (ISCIII). Fernando Laso-García was supported by the Spanish Ministry of Health- (ISCIII) under Grant FI18/00026., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Real-time dose reconstruction in proton therapy from in-beam PET measurements

  • Onecha, V.V.
  • Espinosa-Rodriguez, A.
  • Soneira-Landín, C.
  • Arias-Valcayo, F.
  • Gaitán-Dominguez, S.
  • Martinez-Nouvilas, V.
  • García-Díez, M.
  • Ibáñez, P.
  • España, Samuel
  • Sanchez-Parcerisa, D.
  • Cerrón-Campoo, F.
  • Vera-Sánchez, J.A.
  • Mazal, A.
  • Udias, J.M.
  • Fraile, L.M.
18 páginas, 11 figuras, 1 tabla., Objective. Clinical implementation of in-beam positron emission tomography (PET) monitoring in proton therapy (PT) requires the integration of an online fast and reliable dose calculation engine. This manuscript reports on the achievement of real-time reconstruction of 3D dose and activity maps with proton range verification from experimental in-beam PET measurements. Approach. Several cylindrical homogeneous PMMA phantoms were irradiated with a monoenergetic 70 MeV proton beam in a clinical facility. Additionally, PMMA range-shifting foils of varying thicknesses were placed at the proximal surface of the phantom to investigate range shift prediction capabilities. PET activity was measured using a state-of-the-art in-house developed six-module PET scanner equipped with online PET reconstruction capabilities. For real-time dose estimation, we integrated this system with an in-beam dose estimation algorithm, which combines a graphical processing unit-based 3D reconstruction algorithm with a dictionary-based software, capable of estimating deposited doses from the 3D PET activity images. The range shift prediction performance has been quantitatively studied in terms of the minimum dose to be delivered and the maximum acquisition time. Main results. With this framework, 3D dose maps were accurately reconstructed and displayed with a delay as short as one second. For a dose fraction of 8.4 Gy at the Bragg peak maximum, range shifts as small as 1 mm could be detected. The quantitative analysis shows that accumulating 20 s of statistics from the start of the irradiation, doses down to 1 Gy could be estimated online with total uncertainties smaller than 2 mm. Significance. The hardware and software combination employed in this work can deliver dose maps and accurately predict range shifts after short acquisition times and small doses, suggesting that real-time monitoring and dose reconstruction during PT are within reach. Future work will focus on testing the methodology in more complex clinical scenarios and on upgrading the PET prototype for increased sensitivity, This work was funded by Comunidad de Madrid, Spain under Projects PRONTO-CM (B2017/BMD-3888) and ASAP-CM (S2022/BMD7434). We acknowledge support by UCM under project pFLASH (PR27/21-014); Spanish MCIN/AEI/10.13039/501100011033 under Grants RADFLAP (PID2021-124094OA-I00), FLASHonCHIP (PLEC2022-009256), PROTOTWIN (TED2021-130592B-I00), mPET (PID2021-126998OB-I00) and INVENTOR (PID2022-137114OA-I00); European Union as part of the European Innovation Council's Pathfinder Open Programme: RETIMAGER, 101099096. The authors acknowledge the support from The Centro de protonterapia Quirónsalud, for the beam time, and its technical staff for their contribution to the operation of the accelerator. This contribution is for the Moncloa Campus of International Excellence, "Nuclear Physics Group-UCM," Ref. 910059. Part of the calculations for this work were performed on the "Computing Cluster for Physical Techniques," funded partially by UCM and partially by EU Regional Funds., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analytical positron range model for PET with cross-code Monte Carlo benchmarking

  • Paneque-Yunta, Robert J.
  • Encina-Baranda, Nerea
  • Carter, Lukas M.
  • Galve, Pablo
  • Ibáñez, Paula
  • Abushab, Khaled M.
  • Udías, José M Udías
  • Herraiz, Joaquín L.
22 páginas, 8 figuras, 5 tablas, Introduction. The positron range (PR) effect is a significant factor limiting spatial resolution in positron emission tomography (PET), particularly for high-resolution systems and non-standard isotopes. Objective. This study introduces a novel analytical model to accurately and rapidly describe PR distributions (PRd) for various PET radioisotopes to better include its effect in PET reconstruction algorithms. Approach. The proposed model explicitly incorporates the Coulomb repulsion effect, the multi-branch nature of certain β+ emitters, and the scaling of PR with electronic density. To minimise bias, we used a histogram-free statistical method to derive the cumulative PRd from Monte Carlo (MC) simulated annihilation datasets, avoiding arbitrary histogram binning. A comparative analysis of PR estimates was conducted across three major MC radiation transport algorithm packages: PENELOPE (via PenEasy/PeneloPET), GEANT4 (via GATE), and EGS5 (via PHITS), revealing notable discrepancies between codes, versions, and input configurations, especially at short distances from the source. Main results. The new analytical model demonstrated an excellent reproduction of the simulated data for isotopes including 11C , 13N , 15O , 18F , 64Cu , 68Ga , 82Rb and 124I , achieving in general coefficients of determination (R2) greater than 0.995 and mean absolute percentage errors ≲20%. Compared to previous methods, our model provides a more accurate description of PRd at low distances and offers improved R2 values. Significance. This work provides a robust framework for generating accurate annihilation point spread function kernels, facilitating improved PR correction in quantitative Nuclear Medical Imaging and supporting research with diverse radioisotopes., We acknowledge support from the following grants: FASCINA (PID2021-126998OB-I00), Prototwin Project (TED2021-349130592B-I00), INVENTOR (PID2022-137114OA-I00) and 3PET (PDC2022-133057-I00), funded by the Spanish Ministry of Science, Innovation and Universities (MCIU) through AEI/10.13039/501100011033 and the European Union’s NextGenerationEU/PRT programme and the Spanish Government. P. G. also acknowledges support from the grant JDC2023-051754-I, funded by MCIU/AEI/10.13039/501100011033 and ESF+., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of silicon carbide diodes as cost-effective active detectors for proton UHDR dosimetry

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Ibáñez, Paula
  • Henao, Ángela
  • Sanchez-Parcerisa, Daniel
  • Zazpe, Adrián
  • Del Monte-Garcia, Ines
  • Guardiola Salmerón, Consuelo
Proton therapy allows for better localization of the dose distribution in the tumor. In addition, the FLASH effect can be exploited to reduce the toxicity to healthy tissue by using short-pulsed treatment at ultra-high dose rates (UHDR). Such intense radiation conditions have limited options for active detectors for dosimetry., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Stress-induced takotsubo syndrome: dynamic changes in regional cerebral metabolism revealed by quantitative PET imaging

  • Ariza-Carrasco, Alejandro
  • Yoganathan, Thulaciga
  • Alonso de Leciñana, María
  • Viel, Thomas
  • Mikail, Nidaa
  • Herraiz, Joaquin L.
  • Udias, Jose M.
  • Ibáñez, Paula
  • Tavitian, Bertrand
  • Pérez-Liva, Mailyn
10 páginas, 3 figuras, 1 tabla, Stress significantly contributes to cardiovascular diseases such as Takotsubo syndrome (TTS), which mimics an acute coronary syndrome without coronary obstruction. TTS is triggered by surgery, trauma, and emergency treatments in patients, and is reproduced in animal models by a catecholamine surge that impacts cardiac sympathetic innervation. The action of catecholamines on energy metabolism is well documented in the heart, less so in the brain. We investigated the effects of acute catecholaminergic stress on regional cerebral glucose metabolism and interregional metabolic organization in a TTS rat model using FDG-PET and quantitative two-tissue compartment modeling. Adult female rats received a single intraperitoneal injection of isoprenaline (ISO) (50 mg/kg). Dynamic FDG-PET imaging was performed at baseline, 2 hours (acute phase), and 7 days (recovery phase) post-injection. Kinetic parameters, namely glucose inflow (K1) and glucose phosphorylation (k3), were quantified in 58 brain regions. Interregional metabolic coordination, defined as statistically significant linear correlations between regional kinetic parameters, was assessed across functional brain areas. During the acute phase, the catecholaminergic surge induced widespread reductions in glucose inflow and regional decreases in phosphorylation, particularly in the limbic and sensorimotor areas. During the recovery phase, most regions remained below baseline. Metabolic coordination increased for glucose inflow in both phases but declined for phosphorylation, especially during recovery, indicating a disruption of metabolic synchronization. Persistent changes in brain metabolism imply that mid-to-long-term changes in regional cerebral metabolism may contribute to long-term TTS consequences., MP-L acknowledges support from the Programme Ram´on y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR". JLH acknowl- edges support from grants FASCINA (PID2021-126998OB-I00/), 3PET (PDC2022-133057-I00), Prototwin Project (TED2021-130592B-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/ 10.13039/501100011033/Uni´on Europea Next GenerationEU/PRTR, and “Tecnologías Avanzadas para la Exploraci´on del Universo y sus Componentes” (PR47/21 TAU-CM TAU-PRTR), funded by EU Resilient and NextGeneration funds. This work has been funded with €1.026 million by the Comunidad de Madrid through the LUNABRAIN-CM R&D activities program (TEC-2024/TEC-43), granted by Order 5696/2024, and has also received funding from the Cancer Research for Personalized Medicine – CARPEM project (Site de Recherche Int´egr´e sur le Cancer SIRIC), from the Plan Cancer Physicancer [grant number C16025KS], and from the R´egion Ile-de-France SESAME funds. This work was sup- ported by Knowledge Generation Projects 2022 Type A Oriented Research, Government of Spain PID2022-137114OA-I00. In vivo imag- ing was performed at the Life Imaging Facility of Universit´e Paris Cit´e (Plateforme Imageries du Vivant - PIV), supported by France Life Im- aging [grant number ANR-11-INBS-0006] and Infrastructures Biologie- Sant´e (IBiSa). BT, MP-L, PIG, JLH and JMU acknowledge support from the European Union as part of the European Innovation Council’s Pathfinder Open Programme: RETIMAGER, 101099096., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

First Experimental Microdosimetry Maps in Low-Energy Cyclotron Proton Beams

  • Riera-Llobet, Carla
  • Ibáñez, P.
  • Fleta, Celeste
  • Jiménez-Ramos, M. C.
  • García López, J.
  • Bachiller-Perea, Diana
  • Guardiola Salmerón, Consuelo
This work presents the first findings of microdosimetry measurements covering 12 cm ×0.4 mm of sensitive area on low-energy proton beams (3–14 MeV) of the cyclotron at the National Center of Accelerators (CNA, Spain) with clinical-equivalent fluence rates (∼107protons⋅cm−2⋅s−1) . Sensors are arrays of silicon-based 3D-microdetectors ( 20 μm thickness, 25 μm diameter) that were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. Microdosimetry spectra were recorded at several proton energies both individually and in dual irradiation mode. Tool for particle simulation-based Monte-Carlo simulations recreating the experimental configuration were also performed to compare with the experimental data. A good agreement was found between the simulated and the experimental spectra. The experimental y¯f values in silicon covered from ( 6±1 ) to ( 17.4±0.5 ) keVμm−1 . To the best of our knowledge, this is the largest radiation sensitive surface covered with microdosimeters so far., CSIC’s Proyectos Intramurales Especiales (Grant Number: 20225AT008); Project NEWDOSI through MCIN/AEI/10.13039/501100011033/FEDER, UE (Grant Number: PID2021-123484OB-I00); INVENTOR Project (Grant Number: PID2022-137114OA-I00); UCM and EU Regional Funds through the Clúster de Cálculo para Técnicas Físicas; UCM (Grant Number: MV11/22-5); VI PPIT-US Contract; Ramón y Cajal Fellowship (Grant Number: RYC2020-030247-I/AEI/10.13039/501100011033); CSIC PIE Incorporación CT (Grant Number: 2024ICT157), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Numerical Framework for Deep Learning Photoacoustics Image Reconstruction

  • G. Muñoz, Javier
  • Ariza-Carrasco, Alejandro
  • Cruza, Jorge F.
  • Elvira Segura, Luis
  • Camacho Sosa-Días, Jorge
  • Udías, José M.
  • Alonso de Laciñana, María
  • Rodriguez-Pardo, Jorge
  • Ibáñez García, Paula
  • Pérez-Liva, Mailyn
Forum Acusticum / Euronoise 2025, the 11th EAA Annual European Conference on Acoustics and Noise Control Engineering, joint with the XLVI Spanish Acoustic Conference TECNIACUSTICA 2025, June 23rd to 26th 2025, Málaga (Spain) 4 páginas, 2 figuras, Photoacoustic Imaging (PAI) combines optical excitation with ultrasound detection to produce high-quality molec- ular images of intact biological tissues. Conventional sys- tems rely on Class IV [1] pulsed lasers, which limits clin- ical translation. This work explores the use of pulsed semiconductor diodes for their portability, versatility, and low-cost. However, their lower peak power decreases PAI signal amplitude. Implementing deep learning techniques trained with realistic synthetic data is a promising tech- nique to increase PAI image quality [2]. Here we create a framework which simulates real scenarios taking into account acoustics and optical properties, ultrasound trans- ducer characteristics and fiber bundles features, crucial to optimize reconstruction performance with a Neural Net- work. The simulated experimental setup included an ar- ray of optical fibers connected to semiconductor diodes parallel to a 128-element transducer array which registers the signal generated by the absorbed light. Optical proper- ties were simulated in MCX Monte Carlo software using GPU parallelization. k-Wave software was used for acous- tic simulations and Time-Reversal (TR) image reconstruc- tion. Finally, a Neural Network model implemented using Tensorflow enhanced the reconstruction, recovering up to 3 cm depth and 200 μm of resolution, delivering excep- tional vascular imaging quality., This work received support from the European Union’s Horizon 2020 research and Innovation Pro- gramme under the Marie Sklodowska-Curie Grant Agreement no.101030046, and the Programme Ram´on y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/501100011033 and by the Eu- ropean Union ”NextGenerationEU”/PRTR”. Also, we acknowledge support from grants FASCINA (PID2021- 126998OB-I00/), 3PET (PDC2022-133057-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/10.13039/501100011033/Uni´on Europea Next GenerationEU/PRTR, Prototwin Project (TED2021-349 130592B-I00) and Tecnolog´ıas Avanzadas para la Ex- ploraci´on del Universo y sus Componentes” (PR47/21 TAU-CM TAU- PRTR), funded by EU Resilient and NextGeneration funds. This work was supported by Knowledge Generation Projects 2022 Type A Ori- ented Research, Government of Spain INVENTOR (PID2022-137114OA-I00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Non-Invasive and Low-Cost Photoacoustic/Ultrasound Dual-Modal Imaging System for Carotid Plaque Imaging

  • Ariza-Carrasco, Alejandro
  • G. Muñoz, Javier
  • Cruza, Jorge F.
  • Elvira Segura, Luis
  • L. Herraíz, Joaquín
  • Udías, José M.
  • Alonso de Laciñana, María
  • Rodríguez-Pardo, Jorge
  • Ibáñez García, Paula
  • Pérez-Liva, Mailyn
Forum Acusticum / Euronoise 2025, the 11th EAA Annual European Conference on Acoustics and Noise Control Engineering, joint with the XLVI Spanish Acoustic Conference TECNIACUSTICA 2025, June 23rd to 26th 2025, Málaga (Spain) 4 páginas, 4 páginas, Carotid plaque rupture causes most ischemic strokes, yet current diagnostics focus on arterial stenosis, overlooking 80–90% of vulnerable plaques. This highlights the need for affordable, precise, and non-invasive imaging to as- sess plaque vulnerability. To address this, we developed a low-cost, dual Ultrasound/Photoacoustic system integrat- ing a Vermon L7.5-MHz ultrasound probe, a 128-channel programmable phased array Ultrasound scanner (Dasel, Spain), and pannels of pulsed semiconductor lasers diodes of 5W emitting 100 ns pulses at 447 nm. Synchroniza- tion was managed via external pulse generators, with laser light delivered through optical fibers. Validation utilised phantoms of black nylon threads. GPU-accelerated delay- and-sum beamforming was used for image recontruction. The system achieved 530 μm lateral and 360 μm ax- ial resolution. This system offers a cost-effective, non-invasive approach for high-resolution multiparametric tis- sue characterization. Future aims will be to improve in vivo assessment of plaque vulnerability., This work received support from the European Union’s Horizon 2020 research and Innovation Pro- gramme under the Marie Sklodowska-Curie Grant Agreement no.101030046, and the Programme Ramónn y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/501100011033 and by the Eu- ropean Union ”NextGenerationEU”/PRTR”. Also, we acknowledge support from grants FASCINA (PID2021- 126998OB-I00/), 3PET (PDC2022-133057-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/10.13039/501100011033/Uni´on Europea Next GenerationEU/PRTR, Prototwin Project (TED2021-349 130592B-I00) and Tecnologías Avanzadas para la Ex- ploración del Universo y sus Componentes” (PR47/21 TAU-CM TAU- PRTR), funded by EU Resilient and NextGeneration funds. This work was supported by Knowledge Generation Projects 2022 Type A Ori- ented Research, Government of Spain INVENTOR (PID2022-137114OA-I00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Mapping intratumoral heterogeneity through PET-derived washout and deep learning after proton therapy

  • Cabrales, Pablo
  • Izaquierdo-García, David
  • Onechea, Víctor V.
  • Pérez-Liva, Mailyn
  • Fraile, Luis Mario
  • Udías, José Manuel
  • Herráiz, Joaquín L.
13 páginas, 7 figuras, 4 tablas, The distribution of produced isotopes during proton therapy can be imaged with Positron Emission Tomography (PET) to verify dose delivery. However, biological washout, driven by tissue-dependent processes such as per fusion and cellular metabolism, reduces PET signal-to-noise ratio (SNR) and limits quantitative analysis. In this work, we propose an uncertainty-aware deep learning framework to improve the estimation of washout param eters in post-proton therapy PET, not only enabling accurate correction for washout effects, but also mapping intratumoral heterogeneity as a surrogate marker of tumor status and treatment response. We trained the models on Monte Carlo-simulated data from eight head-and-neck cancer patients, and tested them on four additional head-and-neck and one liver patient. Each patient was represented by 75 digital twins with distinct tumoral washout dynamics and imaged 15 min after treatment, when slow washout components dominate. We also in troduced washed-out maps, quantifying the contribution of medium and fast washout components to the loss in activity between the end of treatment and the start of PET imaging. Trained models significantly improved resolution and accuracy, reducing average absolute errors by 60% and 28% for washout rate and washed-out maps, respectively. For intratumoral regions as small as 5.1 mL, errors predominantly fell below thresholds for differentiating vascular status, and the models generalized across anatomical areas and acquisition delays. This tudy shows the potential of deep learning in post-proton therapy PET to non-invasively map washout kinet ics and reveal intratumoral heterogeneity, supporting dose verification, tumor characterization, and treatment personalization. The framework is available at https://github.com/pcabrales/ppw.git., This work was supported by Spanish MCIN/AEI/10.13039/ 501100011033 and the European Union NextGenerationEU/PRTR un der grants TED2021-130592B-I00 PROTOTWIN, PID2021-126998OB- I00 FASCINA, and PDC2022-133057-I00 3PET; by Comunidad de Madrid (Spain) under projects ASAP-CM P2022/BMD-7434 and TAU- CM PR47/21 (PRTR), and by Grupo de Física Nuclear (910059) at Universidad Complutense de Madrid. Additionally, Pablo Cabrales acknowledges support from the Complutense University Predoctoral Fellowship (CT15-23), funded by the Universidad Complutense de Madrid and Banco Santander, as well as from the Ayuda para estancias breves fellowship (EB33/24), funded by the Universidad Complutense de Madrid. M.Pérez-Liva was supported by the Program Ramón y Cajal RYC2021-032739-I, MCIN/AEI/10.13039/501100011033, by the European Union NextGenerationEU/PRTR, by INVENTOR PID2022- 137114OA-I00, and by LUNABRAIN (PR37/24 TEC-2024/TEC-43), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Numerical Framework for Deep Learning Photoacoustics Image Reconstruction

  • G. Muñoz, Javier
  • Ariza-Carrasco, Alejandro
  • Díaz Cañadas, Bárbara
  • Cruza, Jorge F.
  • Elvira Segura, Luis
  • Camacho Sosa-Días, Jorge
  • L. Herraiz, Joaquín
  • Udías, José M.
  • Bertolet Reina, Alejandro
  • Alonso de Laciñana Cases, María
  • Rodriguez-Pardo, Jorge
  • Mariño Trillo, Eduardo
  • Laso García, Fernando
  • Ibáñez García, Paula
  • Pérez-Liva, Mailyn
23rd IEEE International Symposium on Biomedical Imaging, ISBI 2026, 08-11 April 2026, London, UK. 4 páginas, 3 figuras., Photoacoustic imaging (PAI) combines pulsed optical excitation with ultrasound detection to produce high-contrast molecular and structural images of biological tissues. Conventional PAI systems rely on high-energy pulsed lasers that, despite their excellent performance, remain bulky, costly, and constrained by strict safety requirements, limiting their clinical translation. This work explores the use of pulsed semiconductor diodes as a compact, low-cost, and portable alternative. Although these sources exhibit lower peak power and reduced fluence, advanced computational approaches can compensate for these limitations. We present a numerical framework that integrates realistic optical and acoustic simulations with deep learning reconstruction to enhance image quality under low-fluence conditions. The framework accounts for light propagation, transducer response, and acoustic field effects to generate training datasets that accurately represent experimental conditions. The proposed hybrid reconstruction recovers fine vascular structures up to 3 cm in depth with 200μ m spatial resolution, demonstrating the potential of diode-based PAI systems for affordable and viable PAI., This work received support from: Programme Ramón y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/ 501100011033 and by the European Union “NextGenerationEU”/PRTR”; FASCINA (PID2021-126998OB-I00/), 3PET (PDC2022-133057-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/10.13039/501100011033/ Unión Europea Next GenerationEU/PRTR, Prototwin Project (TED2021-349 130592B-I00) and Tecnologías Avanzadas para la Exploración del Universo y sus Componentes” (PR47/21 TAU-CM TAU- PRTR), funded by EU Resilient and NextGeneration funds; INVENTOR (PID2022-137114OA-I00);project LUNABRAIN-CM (TEC-2024/TEC-43), funded with € 1.026 million by the Comunidad de Madrid through the RD activities program in technologies, granted by Order 5696/2024., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

Analytical positron range model for PET with cross-code Monte Carlo benchmarking

  • Paneque-Yunta, Robert J
  • Encina-Baranda, Nerea
  • Carter, Lukas M
  • Galve Lahoz, Pablo
  • Ibáñez García, Paula Beatriz
  • Abushab, Khaled M
  • Udías Moinelo, José Manuel
  • López Herraiz, Joaquín
Introduction. The positron range (PR) effect is a significant factor limiting spatial resolution in positron emission tomography (PET), particularly for high-resolution systems and non-standard isotopes. Objective. This study introduces a novel analytical model to accurately and rapidly describe PR distributions (PRd) for various PET radioisotopes to better include its effect in PET reconstruction algorithms. Approach. The proposed model explicitly incorporates the Coulomb repulsion effect, the multi-branch nature of certain beta+ emitters, and the scaling of PR with electronic density. To minimise bias, we used a histogram-free statistical method to derive the cumulative PRd from Monte Carlo (MC) simulated annihilation datasets, avoiding arbitrary histogram binning. A comparative analysis of PR estimates was conducted across three major MC radiation transport algorithm packages: PENELOPE (via PenEasy/PeneloPET), GEANT4 (via GATE), and EGS5 (via PHITS), revealing notable discrepancies between codes, versions, and input configurations, especially at short distances from the source. Main results. The new analytical model demonstrated an excellent reproduction of the simulated data for isotopes including 11C, 13N, 15O, 18F, 64Cu, 68Ga, 82Rb and 124I, achieving in general coefficients of determination (R2) greater than 0.995 and mean absolute percentage errors less than or similar to 20%. Compared to previous methods, our model provides a more accurate description of PRd at low distances and offers improved R2 values. Significance. This work provides a robust framework for generating accurate annihilation point spread function kernels, facilitating improved PR correction in quantitative Nuclear Medical Imaging and supporting research with diverse radioisotopes.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Dosimetric evaluation of 6 MV photon beams in small fields using PRIMO-penEasy Monte Carlo

  • Díaz, Nataly
  • Villa Abaunza, Amaia
  • Muñoz, Jorge
  • Udías Moinelo, José Manuel
  • Ibáñez García, Paula Beatriz
Dosimetric validation of clinical radiotherapy plans for small fields requires high-precision instrumentation to ensure accuracy and spatial resolution. This study proposes a combination of PRIMO and penEasy Monte Carlo simulators to address scenarios where direct measurements are impractical, challenging, or yield inconsistent results due to detector limitations. We compared three dosimetric tools: A Semiflex ionization chamber PTW (model 31010) within a water-filled acrylic tank; EBT3 radiochromic films positioned between solid water layers; and PRIMO-PenEasy simulations. Experiments were performed at San Ignacio University Hospital in Bogota, Colombia, with dose measurements in two small fields and one conventional field for an Axesse-type linear accelerator. Results indicate that EBT3 radiochromic film show better agreement with MC simulation than the Semiflex ionization chamber, likely due to the chamber dose averaging effect across its detection volume. Additionally, variations in off-axis ratios were noted in both crossplane and inplane directions with more pronounced discrepancies observed in small fields compared to the conventional field. Overall, PRIMO-PenEasy MC simulations demonstrated accurate dose distributions and can be used as a viable for dosimetric validation in small photon fields.
Docta Complutense
Publicación Artículo científico (JournalArticle)

First experimental microdosimetry maps in low-energy cyclotron proton beams

  • Carla Riera-Llobet
  • Ibáñez García, Paula Beatriz
  • Celeste Fleta
  • MC Jiménez-Ramos
  • J. García López
  • D. Bachiller-Perea
  • Consuelo Guardiola
This work presents the first findings of microdosimetry measurements covering 12 cm x 0.4 mm of sensitive area on low-energy proton beams (3-14 MeV) of the cyclotron at the National Center of Accelerators (CNA, Spain) with clinical-equivalent fluence rates (similar to 10(7)protons cm(-2) s(-1)). Sensors are arrays of silicon-based 3D-microdetectors (20 mu m thickness, 25 mu m diameter) that were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. Microdosimetry spectra were recorded at several proton energies both individually and in dual irradiation mode. Tool for particle simulation-based Monte-Carlo simulations recreating the experimental configuration were also performed to compare with the experimental data. A good agreement was found between the simulated and the experimental spectra. The experimental y(f )values in silicon covered from (6 +/- 1) to (17.4 +/- 0.5) keV mu m(-1). To the best of our knowledge, this is the largest radiation sensitive surface covered with microdosimeters so far.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Impact on the estimated dose of different tissue assignment strategies during partial breast irradiations with INTRABEAM

  • Ibáñez García, Paula Beatriz
  • Villa Abaunza, Amaia
  • Udías Moinelo, José Manuel
Purpose: Partial breast irradiations with electronic brachytherapy or kilovoltage intraoperative radiotherapy devices such as Axxent or INTRABEAM are becoming more common every day. Breast is mainly composed of glandular and adipose tissues, which are not always clearly disentangled in planning breast CTs. In these cases, breast tissues are replaced with an average soft tissue, or even water. However, at kilovoltage energies, this may lead to large differences in the delivered dose, due to the dominance of photoelectric effect. Therefore, the aim of this work was to study the effect on the dose prescribed in breast with the INTRABEAM device using different soft tissue assignment strategies that would replace the adipose and glandular tissues that constitute the breast in cases where these tissues cannot be adequately distinguished in a CT scan. Methods and materials: Dose was computed with a Monte Carlo code in five patients with a 3 cm diameter INTRABEAM spherical applicator. Tissues within the breast were assigned following six different strategies: one based on the TG-43 recommendations, representing the whole breast as water of unity density, another one also water-based but with CT derived density, and the other four also based on CT-derived densities, using a single tissue resulting from different mixes of glandular and adipose tissues. These were compared against the reference dose computed in an accurately segmented CT, following TG-186 recommendations. Relative differences and dose ratios between the reference and the other tissue assignment strategies were obtained in three regions of interest inside the breast. Results and conclusions: Dose planning in water-based tissues was found inaccurate for breast treatment with INTRABEAM, as it would incur in up to 30% under-prescription of dose. If accurate soft tissue assignments in the breast cannot be safely done, a single-tissue composition of 80% adipose and 20% glandular tissue, or even a 100% adipose tissue, would be recommended to avoid dose under-prescription.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Development and validation of a Monte Carlo model of a mobile accelerator for intraoperative radiation therapy

  • Ayala, Rafael
  • Soza, Álvaro
  • García, María Jesús
  • García, Rocío
  • Udías Moinelo, José Manuel
  • Ibáñez García, Paula Beatriz
Background Intraoperative electron radiation therapy (IOERT) relies on accurate and precise dose delivery to the tumor or tumor bed using mobile accelerators and interchangeable applicators, while critical organs are typically displaced or shielded during surgery. Treatment planning and linac commissioning are often based on water measurements, Monte Carlo (MC) simulations of the accelerator head and applicator system provide detailed insights into dose distributions and beam characteristics, offering additional support for clinical evaluation. Purpose This study develops an MC model of the Liac HWL mobile accelerator using a hypothetical linac head geometry, due to the limited availability of detailed information on its internal components resulting from manufacturer disclosure policies. The model is optimized by adjusting three geometric parameters of the linac head and the initial beam energy spectrum to match experimental data. Additionally, it provides a set of Phase Space Files (PSFs) to support research and clinical applications. Methods The MC code PENELOPE, integrated with the penEasy framework, was used to simulate the Liac HWL. The hypothetical head geometry was defined by parameters such as the inner diameter of the head, the thickness of the scattering foil, and the thickness of the exit window. Output factors (OFs), percentage depth doses (PDDs), and off‐axis ratios (OARs) were calculated in a virtual water phantom for different applicator sizes, bevel angles, and energies. Gamma analysis was employed to validate the model by comparing calculated and measured dose distributions. PSFs were made available in the IAEA PHSP format at four energies (6, 8, 10, and 12 MeV). Results The model matched measured OFs within 2.5%. PDDs and OARs met the gamma analysis criteria (2% dose difference and 1 mm distance‐to‐agreement) in more than 93% of the studied cases, with the worst‐case scenario occurring for the smallest applicator (3 cm diameter) with a 45° bevel angle at 6 MeV, resulting in OAR gamma passing rates of 85.7% at and 86.1% at . Conclusions Despite the use of a hypothetical geometry, the model offers accurate dosimetric data and practical guidance for IOERT commissioning and treatment planning. It highlights potential dosimetric issues, particularly the lack of homogeneity in OARs for large‐diameter applicators, and allows fine‐tuning based on real‐world data. Additionally, the PSFs generated in this study provide a reliable resource for simulating IORT dose distributions and analyzing the characteristics of IOERT beams.