Pasar al contenido principal

DESARROLLOS TECNOLOGICOS PARA NUEVOS DETECTORES DE ESTADO SOLIDO PARA DOSIMETRIA AVANZADA

PID2021-123484OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 16
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Characterisation of SiC radiation technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
Raw data obtained at the ALBA synchrotron with SiC diode devices for the paper: "Characterisation of SiC radiation detector technologies with synchrotron X-rays", This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., List of files: . Fig3-linescan-SiC-Graphene_50x50_2.dat . Fig3-linescan-SiC-Metal3um_50x50_2.dat . Fig3-LineScan_SiC-NoMetal3um_50x50_2.dat . Fig3-LineScan_SiC_metal50um_50x50.dat . Fig4-currenscan_SiC_metal50um_50x50.dat . Fig4-currentscan-SiC-Graphene_50x50_3.dat . Fig4-currentscan-SiC-Metal3um_50x50_3.dat . Fig5-Energyscan-SiC-Graphene_50x50_2.dat . Fig5-Energyscan-SiC-Metal3um_50x50_1.dat . Fig5-Energyscan-SiC-Metal3um_inRing_50x50_2.dat . Fig5-Energyscan-SiliconReference_Hamamatsu-P1_sample1_50x50_3_sorted.dat . Fig5-EnergyScan_SiC_metal50um_50x50_removed_saturated.dat, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterisation of SiC radiation detector technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
To cope with environments with high levels of radiation, non-silicon semiconductors such as silicon carbide detectors are being proposed for instrumentation. 4H-SiC diodes for radiation detection have been fabricated in the IMB-CNM Clean Room, for which different strategies to define the electrical contact of the implants had been implemented, in an attempt to optimise the technology for, e.g., medical applications or low energy radiation detection, as the material choice can affect the sensitivity of the device. Among these technologies, it is included an epitaxially-grown graphene layer as part of the electrical contact. In this paper, a selection of four configurations of the IMB-CNM SiC diodes are characterised in terms of radiation detector response. Photodiode performance under 20 keV X-rays irradiation in the XALOC beam line at ALBA Synchrotron is presented. Over-responses in the range of 12-19% linked to the interaction of the radiation with the metallic layers are observed. A good uniformity response as well as a good linearity at 0~V bias is reported, even in the under-depleted devices. This work exemplifies the good performance of SiC detectors fabricated at IMB-CNM specifically for low-energy X ray characterization at high X-ray intensities., This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023- 001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Silicon Carbide Diodes at IMB-CNM: Advancing High-Precision Dosimetry for FLASH Radiotherapy

  • Celeste Fleta
  • Iván López-Paz
  • Giulio Pellegrini
  • Marcio Jiménez
  • Angela Henao
  • Consuelo Guardiola
  • María del Carmen Jiménez-Ramos
  • Carmen Torres-Muñoz
  • Javier García López
  • Faustino Gómez
  • José Paz-Martín
The main challenge in radiotherapy (RT) is to deliver a sufficiently high curative dose to the tumour while maintaining tolerable doses to nearby organs at risk, and new treatment modalities are rapidly emerging. FLASH radiotherapy delivers a therapeutic dose several orders of magnitude faster (≥ 40 Gy/s) than conventional RT (0.05 Gy/s) and has been shown to reduce the likelihood of complications in normal tissues while providing a similar or better tumour control rate than conventional dose rates, reducing treatment time and organ motion-related issues. However, there are significant challenges to the clinical implementation of FLASH RT, as its requirements make most existing dosimetry equipment obsolete. The physical properties of silicon carbide (SiC) make it an interesting material for radiation dosimetry. The wide bandgap of SiC reduces the rate of thermally generated charge carriers, thereby reducing leakage current and noise compared to silicon. Of particular interest is the signal yield per deposited mGy in SiC (425 pC/(mGy·mm3) for 4H-SiC) which is lower than for silicon. This makes SiC a good option for dosimetry in ultra-high dose pulsed radiation fields or direct beam monitoring, where the instantaneous dose deposition in the semiconductor is large and could saturate conventional silicon diodes. In addition, SiC has a higher displacement energy threshold and therefore higher radiation hardness than silicon. Today, SiC technology is mature and high quality substrates are available up to 200mm, allowing widespread use. In this talk we will present the novel silicon carbide PiN diodes that have been designed and fabricated at IMB-CNM with the aim to respond to the technological challenges of FLASH RT. In a first characterization with 20 MeV FLASH electron beams at PTB (Germany), these diodes showed their suitability for relative dosimetry up to a dose of 11 Gy per pulse (4 MGy/s) and a dosimetric performance comparable to commercial diamond dosimeters [doi:10.1088/1361-6560/ad37eb]. The performance of the SiC diodes with FLASH proton beams was tested with 7 MeV protons at CMAM (Spain) where they showed good signal linearity with dose rate and reproducible response up to a dose per pulse of at least 20 Gy. Finally, the radiation resistance of the diodes was studied at CNA (Spain) using high LET, intense pulsed proton beams. The sensitivity of the diodes showed a progressive decrease at an initial rate of -1.34%/kGy of 1 MeV protons, and stabilised only for doses close to 750 kGy. However, the linear response with dose per pulse was maintained over a wide range of dose rates even for cumulative doses of several MGy. All of these measurements were made without the need for an external applied voltage. In conclusion, silicon carbide diodes fabricated at IMB-CNM are a real alternative to silicon and diamond dosimeters in a wide range of applications where accurate real-time relative dosimetry, fast response and long-term stability are required., UHDPulse: the EMPIR programme cofinanced by the Participating States and from the European Union's Horizon 2020 research and innovation program (18HLT04). NEWDOSI: Desarrollos tecnológicos para nuevos detectores de estado solido para dosimetría avanzada (PID2021-123484OB-I00). CARACTERIZACION: Caracterización de dosímetros avanzados fabricados en el IMB-CNM para aplicaciones médicas (202250I185). Microdetectors for medical applications. Proyectos Intramurales Especiales CSIC (20225AT008). Dosimetry monitor for FLASH therapy. LaCaixa foundation (HR23-00718), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Dosímetros de Carburo de Silicio resistentes a la radiación para radioterapia de protones y FLASH

  • Ivan Lopez Paz
  • Fleta, Celeste
  • Ángela Henao
  • Marcio Jimenez
  • Mª Carmen Jimenez-Ramos
  • Carmen Torres-Muñoz
  • Javier García-López
  • Paula Ibañez
  • Daniel Sanchez-Parcerisa
  • Adrián Zazpe
  • Inés del Monte-Garcia
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Caracterización de nuevos dosímetros resistentes a la radiación en condiciones FLASH con electrones

  • Angela Henao
  • Iván López Paz
  • Fleta, Celeste
  • Sophie Heinrich
  • Faustino Gómez
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Innovative SiC detectors for FLASH radiotherapy

  • Angela Henao Isaza
  • Ivan Lopez Paz
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

SiC dosimetry monitor for FLASH Radiotherapy treatments

  • Angela María Henao Isaza
  • Guardiola Salmerón, Consuelo
  • Iván López Paz
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of silicon carbide diodes as cost-effective active detectors for proton UHDR dosimetry

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Ibáñez, Paula
  • Henao, Ángela
  • Sanchez-Parcerisa, Daniel
  • Zazpe, Adrián
  • Del Monte-Garcia, Ines
  • Guardiola Salmerón, Consuelo
Proton therapy allows for better localization of the dose distribution in the tumor. In addition, the FLASH effect can be exploited to reduce the toxicity to healthy tissue by using short-pulsed treatment at ultra-high dose rates (UHDR). Such intense radiation conditions have limited options for active detectors for dosimetry., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions

  • Jiménez-Ramos, M. Carmen
  • Torres-Múñoz, Carmen
  • García-López, Javier
  • Barroso-Molina, Diego
  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications., This work has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse. It has also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718) M. Carmen Jim´enez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4” with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions, Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions

  • Jiménez-Ramos, M. Carmen
  • Torres-Múñoz, Carmen
  • García-López, Javier
  • Barroso-Molina, Diego
  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications., This work has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse. It has also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718) M. Carmen Jim´enez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4” with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla., List of files: . Fig_11_12_Ratio; Fig_11_Ratio; Fig_13_Detector; Fig3_single; Fig7a_RBS; Fig7b_MCS; Fig8_9RBS; Fig10; README.txt, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Microdosimetry Maps in Continuous and Pulsed Alpha Beams

  • Zhu, Yuwei
  • Riera-Llobet, Carla
  • Fleta, Celeste
  • Manna, Maria
  • Leite, Amelia Maia
  • Lopez, Gaston Garcia
  • Tavora, Vicente Garcia
  • Bachiller-Perea, Diana
  • Mouchard, Quentin
  • Guardiola Salmerón, Consuelo
The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2D-maps delivered by alpha beams with the highest resolution so far (400 μm × 600 μm) using a customized sensor. It consists of 3 multi-arrays of 50 3 × 3 microdetectors with a pitch of 200 μm that cover a total radiation sensitive area of 9 cm × 0.4 mm. The microdetectors are based on a novel 3D-cylindrical silicon architecture with 25-μm diameter and 20-μm thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accelerateur Lineaire et Tandem a Orsay (ALTO), France, and irradiated with pulsed beams (from 1.4 μs to 3.3 μs pulse widths) of 7.5 MeV alphas in the Centro de Micro-Analisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode (~ 10<sup>8</sup> cm<sup>‒2</sup>s<sup>‒1</sup>) and in pulsed regimes with higher fluence rates up to ~ 10<sup>10</sup> cm<sup>-2</sup>-s<sup>-1</sup>. Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes., This work was supported in part by the \u201CTowards Clinical Implementation of Advanced Microdosimetry and Radiobiology for Hadron Therapy\u201D Projects (LabEx P2IO). Consuelo Guardiola thanks the funding from the Proyecto Intramural Especial a (20225AT008) of CSIC. The 3D-cylindrical microdetectors fabrication was funded from the H2020 project AIDA-2020, GA no. 654168. This work made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. The work also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE. Gast\u00F3n Garc\u00EDa L\u00F3pez acknowledges funding by Comunidad de Madrid under projects S2022/BMD-7434 ASAP-CM \u201CAdvanced Strategies and new Approaches for Protontherapy\u201D and PR27/21-014 (pFLASH), and by the Agencia Estatal de Investigaci\u00F3n under projects PLEC2022-009256 \u201CComprendiendo la radioterapia flash con dispositivos de tejido-en-chip y resonancia magn\u00E9tica mejorada con hiperpolarizaci\u00F3n\u201D ?FLASH-on-chip) and PID2021-124094OA-I00 (RADFLAP). (Corresponding author: Consuelo Guardiola). This work did not involve human subjects or animals in its research., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

First Experimental Microdosimetry Maps in Low-Energy Cyclotron Proton Beams

  • Riera-Llobet, Carla
  • Ibáñez, P.
  • Fleta, Celeste
  • Jiménez-Ramos, M. C.
  • García López, J.
  • Bachiller-Perea, Diana
  • Guardiola Salmerón, Consuelo
This work presents the first findings of microdosimetry measurements covering 12 cm ×0.4 mm of sensitive area on low-energy proton beams (3–14 MeV) of the cyclotron at the National Center of Accelerators (CNA, Spain) with clinical-equivalent fluence rates (∼107protons⋅cm−2⋅s−1) . Sensors are arrays of silicon-based 3D-microdetectors ( 20 μm thickness, 25 μm diameter) that were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. Microdosimetry spectra were recorded at several proton energies both individually and in dual irradiation mode. Tool for particle simulation-based Monte-Carlo simulations recreating the experimental configuration were also performed to compare with the experimental data. A good agreement was found between the simulated and the experimental spectra. The experimental y¯f values in silicon covered from ( 6±1 ) to ( 17.4±0.5 ) keVμm−1 . To the best of our knowledge, this is the largest radiation sensitive surface covered with microdosimeters so far., CSIC’s Proyectos Intramurales Especiales (Grant Number: 20225AT008); Project NEWDOSI through MCIN/AEI/10.13039/501100011033/FEDER, UE (Grant Number: PID2021-123484OB-I00); INVENTOR Project (Grant Number: PID2022-137114OA-I00); UCM and EU Regional Funds through the Clúster de Cálculo para Técnicas Físicas; UCM (Grant Number: MV11/22-5); VI PPIT-US Contract; Ramón y Cajal Fellowship (Grant Number: RYC2020-030247-I/AEI/10.13039/501100011033); CSIC PIE Incorporación CT (Grant Number: 2024ICT157), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Small dose monitor based on silicon-carbide diodes for FLASH radiotherapy

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Henao, Ángela
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
The FLASH biological effect in radiotherapy has been observed to appear at ultra-high dose rates UHDR ( >$>$ 40 Gy/s), where the accurate dosimetry at such high rates is still a challenge., This study was funded by the LaCaixa Health foundation DosiFLASH Project (HR23-00718), the UHDPulse project, EMPIR programme cofinanced by the European Union's Horizon 2020 research and innovation program (18HLT04), the TWAC: EIC Pathfinder Open 2021 (101046504 project), the CSIC PIE Incorporación CT (2024ICT157), and the NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE. The project also received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M / AEI/10.13039/501100011033). The authors would like to thank Nabil Karkour, Vincent Alaphilippe and Guillaume Martinet from the IJCLab (CNRS) for their technical assistance during the data taking period. The authors would also like to thank Faustino Gómez for his assistance with a part of the readout electronics., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ion-beam-induced charge study of new 4H-SiC detectors for microdosimetry

  • Jiménez Venegas, Marcio
  • Guardiola Salmerón, Consuelo
  • Pellegrini, Giulio
  • Torres Muñoz, Carmen
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Godignon, Philippe
  • Fleta, Celeste
Novel radiation detectors based on 4H-SiC, developed at IMB-CNM, CSIC, have been characterized by means of the ion beam induced charge (IBIC) technique. In this work, two 4H-SiC microdetector designs (planar and 3D), with a thickness of 3 μm and a diameter of 30 μm, were tested using 2.5 MeV He2+ ions. The energy spectral response indicates diffusion effects at 0 V in the planar detector, which are significantly minimized in the 3D detector thanks to its geometry obtained through a SiC mesa process. The 3D architecture confines the charge collection region and reduces charge contributions from outside of the sensitive volume. Such characteristics highlight the advantages of 3D structures for applications requiring well-defined sensitive volumes, such as microdosimetry. Additionally, the 4H-SiC devices exhibited up to a 26% decrease in charge collection efficiency and a 16% reduction in the frequency mean lineal energy (yF ) after irradiation of 2.5 MeV alpha particles at a fluence of 1.55 × 1011 alphas/cm2 at 0 V, attributed to charge collection degradation due to radiation-induced lattice defects that introduce carrier trapping and recombination centers. Applying reverse bias partially restored the initial performance. Therefore, proper calibration becomes essential once the accumulated fluence leads to variations in both energy spectrum and yF beyond the acceptable deviation limits., This work has received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN/AEI/10.13039/501100011033/FEDER, UE, from project FLASH (PDC2022-133120-C21), financed by MCIN/AEI/10.13039/501100011033/NextGenerationEU/PRTR, and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718). The project also received support from the Spanish government through the “María de Maeztu Unit of Excellence” accreditation (CEX2023-001397-M, funded by MICIU/AEI/10.13039/501100011033)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Radiation damage study of three-dimensional cylindrical silicon microdosimeters

  • Torres Muñoz, Carmen
  • Jiménez-Ramos, M. C.
  • García López, J.
  • García-Osuna, Adrián
  • Fleta, Celeste
  • Gómez, Faustino
  • Guardiola Salmerón, Consuelo
A novel silicon microdosimeter with a 3D cylindrical “dartboard” geometry has been developed at the National Center of Microelectronics (IMB-CNM) in Barcelona, Spain. The detector features concentric 3D electrodes etched into a 20μ⁢m-thick sensitive silicon volume. Its performance has been characterized using the ion beam-induced charge (IBIC) technique, and its radiation hardness has been investigated in view of potential applications in proton therapy., The central region was irradiated with 1.17 MeV protons up to a cumulative fluence of 1.7×1⁢012cm−2, with a bias voltage of 5 V. Spatially resolved charge collection efficiency (CCE) maps and pulse height spectra were analyzed as a function of the accumulated fluence. No significant degradation was observed for fluences below 6×1⁢010cm−2. At higher fluences, however, progressive CCE reduction occurs, accompanied by peak broadening, spectral redistribution towards lower pulse height and contraction of the effective high-efficiency sensor region. This degradation is more pronounced at the periphery of the sensitive volume, which is consistent with the radial electric field distribution inherent to the 3D geometry., This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4”, with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla. This work has received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN/AEI/10.13039/501100011033/ FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718). This project has been also funded by the Spanish Nuclear Safety Council (CSN) under the Subvenciones 2022 SUB-08 programme. This work has received funding from the project “CNA activities for the CMS high luminosity upgrade and ECFA DRDs” (PID2023-148418NB-C44), financed by Ministry of Science, Innovation and Universities ., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

First experimental microdosimetry maps in low-energy cyclotron proton beams

  • Carla Riera-Llobet
  • Ibáñez García, Paula Beatriz
  • Celeste Fleta
  • MC Jiménez-Ramos
  • J. García López
  • D. Bachiller-Perea
  • Consuelo Guardiola
This work presents the first findings of microdosimetry measurements covering 12 cm x 0.4 mm of sensitive area on low-energy proton beams (3-14 MeV) of the cyclotron at the National Center of Accelerators (CNA, Spain) with clinical-equivalent fluence rates (similar to 10(7)protons cm(-2) s(-1)). Sensors are arrays of silicon-based 3D-microdetectors (20 mu m thickness, 25 mu m diameter) that were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. Microdosimetry spectra were recorded at several proton energies both individually and in dual irradiation mode. Tool for particle simulation-based Monte-Carlo simulations recreating the experimental configuration were also performed to compare with the experimental data. A good agreement was found between the simulated and the experimental spectra. The experimental y(f )values in silicon covered from (6 +/- 1) to (17.4 +/- 0.5) keV mu m(-1). To the best of our knowledge, this is the largest radiation sensitive surface covered with microdosimeters so far.