Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

IBIC analysis of SiC detectors developed for fusion applications

  • Jiménez-Ramos, M. C.
  • García López, J.
  • García-Osuna, Adrián
  • Rodríguez-Ramos, M.
  • Villalpando Barroso, A.
  • García-Muñoz, M.
  • Andrade, Eduardo
  • Pellegrini, Giulio
  • Otero Ugobono, Sofia
  • Godinho, Vanda
  • Rafí, Joan Marc
  • Rius, Gemma
In this work, we consider a 4H-SiC detector as a plasma diagnostic system for the detection of fusion-born alpha particles in future nuclear fusion reactors. A nuclear microprobe was used to locally irradiate micrometer-sized regions of the detector with 3.5 MeV He ions to fluences from 5 × 109 to 5 × 1011 cm-2. Ion Beam Induced Charge (IBIC) microscopy was employed to study its degradation in Charge Collection Efficiency (CCE) and energy resolution after irradiation. At high reverse-bias voltages, both parameters remain practically unaffected for fluences up to 1 × 1011 cm-2, while a significant deterioration of the spectroscopic performance was observed above 3 × 1011 cm-2. A theoretical drift-diffusion model, in combination with Shockley-Read-Hall recombination statistics, was used to obtain the holes lifetime from the fitting of the experimental CCE values measured at different reverse voltages. Holes lifetime was found to strongly decrease with increasing particle fluence, changing from 57 ns in pristine detectors to 0.2 ns after irradiation with a fluence of 1 × 1011 cm-2., This work was partially funded by the Spanish Ministry of Economy and Competiveness through the Project FIS2015-69362-P (MINECO/FEDER/UE), the Spanish Ministry of Science, Innovation, and Universities through the project RTC-2017-6369-3 (MICINN/FEDER/UE) and the EUROfusion Project CFP-IPH-AWP19-SA-05-CIEMAT-01 (H2020). E. Andrade acknowledges the PASPA-UNAM financial support provided to undertake a sabbatical year and CNA for the invitation to spend his sabbatical in this Institution. G. Rius acknowledges the research grant Nº. RYC-2016-21412., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Research facilities and highlights at the Centro Nacional de Aceleradores (CNA)

  • Gómez-Camacho, Joaquín
  • García López, J.
  • López-Gutiérrez, J. M.
  • García-Tenorio, R.
  • Santos, F. J.
  • Chamizo, Elena
  • Ferrer, F. J.
  • Jiménez-Ramos, M. C.
  • Balcerzyk, Marcin
  • Fernández-Martínez, Begoña
Part of a collection: Focus Point on Small and Medium and Particle Accelerator Facilities in Europe, The Centro Nacional de Aceleradores is a user-oriented accelerator facility in Seville, Spain. Its main facilities are a 3 MV tandem accelerator, an 18 MeV proton Cyclotron, a tandetron used for AMS, a compact accelerator used for radiocarbon measurements, a Co irradiator and a PET/CT scanner. The technical specifications and research applications of these facilities are described. A neutron beam line associated to a charged pulsed beam in the tandem allows for time of flight measurements which determine the neutron energy. The use of an adequate stripper gas in the AMS tandetron permits to measure heavy radionuclides with very low detection levels, allowing to perform environmental studies using these radionuclides as tracers. The use of the microbeam in the tandem accelerator allows to apply the ion beam-induced current technique to investigate the spectroscopic properties and radiation hardness of different semiconductor detectors., Also the funding made available for infrastructures through the ICTS program of the Spanish ministry of science, making use of FEDER funds from the European Union. The continuous support of CNA patrons, the University of Seville, the Junta de Andalucía and CSIC is acknowledged. Private funds, through contracts with companies and institutions, such as Curium, Alter technologies, and the andalusian health service (SAS), made possible to maintain contracts of key personnel. We acknowledge the funding of projects by the European Union, H2020-847594, H2020-654002, H2020-847552, H2020-847594 , by the Spanish ministry of science RTI2018-098117-B-C21, RTC-2017-6369-3, EQC2018-004193-P, EQC2018-004095-P, EQC2018-004166-P, PGC2018-094546-B-I00, and by the Junta de Andalucía FEDER progrem US-1261006, US-1263369, P18-RT-1900.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Spectrometric performance of SiC radiation detectors at high temperature

  • Jiménez-Ramos, M. C.
  • García-Osuna, Adrián
  • Rodríguez-Ramos, M.
  • Viezzer, Eleonora
  • Pellegrini, Giulio
  • Godignon, Philippe
  • Rafí, Joan Marc
  • Rius, Gemma
  • García López, J.
In this work, we have investigated the performance of a 4H–SiC radiation sensor in the temperature range from 25 °C to 450 °C to explore its compatibility as detector of fast ion losses in plasma diagnostic of future nuclear fusion reactors. To simulate the escape of fusion-born alpha particles in D-T (deuterium-tritium) fusion plasmas, spectroscopic measurements were carried out in a vacuum chamber by irradiating the detector with a 3.5 MeV alpha beam from a Tandem accelerator. The detector was found to have an energy resolution ≤2% over the entire temperature range analyzed. Relevantly, the excellent spectrometric capabilities of the device have allowed us to calculate from experimental data, with unprecedented accuracy, the average energy required to create a single electron-hole pair in 4H–SiC as a function of temperature., This research was funded by the Spanish Ministry of Science, Innovation and Universities grant numbers RTC-2017-6369-3 (FEDER/EU) and ICTS-2020-02 US-4 (FEDER/EU), the Regional Ministry of Economy, Knowledge, Business and University grant number US-1380791, the Spanish Ministry of Science, Innovation grant number PID 2020 116822RB-I00 and PID 2021-124660OB-C22., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Performance of neutron-irradiated 4H-silicon carbide diodes subjected to alpha radiation

  • Gaggl, Philipp
  • Gsponer, Andreas
  • Thalmeier, Richard
  • Waid, Simon
  • Pellegrini, Giulio
  • Godignon, Philippe
  • Rafí, Joan Marc
  • Bergauer, Thomas
The unique electrical and material properties of 4H-silicon-carbide (4H-SiC) make it a promising candidate material for high rate particle detectors. In contrast to the ubiquitously used silicon (Si), 4H-SiC offers a higher carrier saturation velocity and larger breakdown voltage, enabling a high intrinsic time resolution and mitigating pile-up effects. Additionally, as radiation hardness requirements grow more demanding in the context of future high luminosity high energy physics experiments, wide-bandgap materials such as 4H-SiC could offer better performance due to low dark currents and higher atomic displacement thresholds. In this work, the detector performance of 50 µm thick 4H-SiC p-in-n planar pad sensors was investigated at room temperature, using an 241Am alpha source at reverse biases of up to 1100 V. Samples subjected to neutron irradiation with fluences of up to 1 × 1016 neq/cm2 were included in the study in order to quantify the radiation hardness properties of 4H-SiC. A calibration of the absolute number of collected charges was performed using a GATE simulation. The obtained results are compared to previously performed UV transient current technique (TCT) studies. Samples exhibit a drop in charge collection efficiency (CCE) with increasing irradiation fluence, partially compensated at high reverse bias voltages far above full depletion voltage. At fluences of 5 × 1014 neq/cm2 and 1 × 1015 neq/cm2, CCEs of 64 % and 51 % are obtained, decreasing to 15 % at 5 × 1015 neq/cm2. A plateau of the collected charges is observed in accordance with the depletion of the volume the alpha particles penetrate for an unirradiated reference detector. For the neutron-irradiated samples, such a plateau only becomes apparent at higher reverse bias, roughly 600 V and 900 V for neutron fluences of 5 × 1014 neq/cm2 and 1 × 1015 neq/cm2. For the highest investigated fluence, CCE behaves almost linearly with increasing reverse bias. Compared to UV-TCT measurements, the reverse bias required to deplete a sensitive volume covering full energy deposition is lower, due to the small penetration depth of the alpha particles. At the highest reverse bias, the measured CCE values agree well with earlier UV-TCT studies, with discrepancies between 1% and 5%., This project has received funding from the Austrian Research Promotion Agency FFG, Grant Number 883652. Production and development of the 4H-SiC samples was supported by the Spanish State Research Agency (AEI) and the European Regional Development Fund (ERDF), ref. RTC-2017-6369-3., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of new silicon carbide neutron detectors with thermal and fast neutrons

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, C.
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
The aim of this work is to present a characterization of a new silicon carbide (SiC) neutron detector fabricated at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC). The device is based on a 50μm thick p-n diode built in a 4H-SiC wafer. Performance studies were carried out under different neutron energy spectra, including thermal and quasi-monoenergetic fast neutrons at the CNA HiSPANoS facility. We implemented a method for the fabrication of enriched LiF conversion layers to use for the detection of thermal neutrons. The detector was proven to be capable of being used for thermal neutron detection with conversion layers of 10B and LiF. A detection efficiency of 6 ± 1% was achieved with a 25μm thick LiF conversion layer. It was also confirmed that the device can be employed for the detection of recoil nuclei and protons produced by fast neutrons. The spectra obtained experimentally were compared with PHITS simulations. This work represents the first step towards the design and fabrication of new SiC neutron detectors in the IMB-CNM-CSIC clean room with potential applications in various scientific and technological fields., This project has received funding from the European Union Horizon2022 research and innovation programme under the Marie Sklodowska-Curie grant agreement N◦101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Sub-venciones 2022 SUB-08. In addition, it has also received funding bySpanish Ministry of Science, Innovation and Universities grant num-ber CEX2023-001397-M, and by the European Union’s ERDF program(MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22. The authors would like to thank Javier Bravo, IvánLopez Paz, Xavier Ayesta, and Esteve Cot for their technical assistance,and also the staff of IMB-CNM-CSIC and CNA., With funding from the Spanish goverment through th "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Characterisation of SiC radiation technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
Raw data obtained at the ALBA synchrotron with SiC diode devices for the paper: "Characterisation of SiC radiation detector technologies with synchrotron X-rays", This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., List of files: . Fig3-linescan-SiC-Graphene_50x50_2.dat . Fig3-linescan-SiC-Metal3um_50x50_2.dat . Fig3-LineScan_SiC-NoMetal3um_50x50_2.dat . Fig3-LineScan_SiC_metal50um_50x50.dat . Fig4-currenscan_SiC_metal50um_50x50.dat . Fig4-currentscan-SiC-Graphene_50x50_3.dat . Fig4-currentscan-SiC-Metal3um_50x50_3.dat . Fig5-Energyscan-SiC-Graphene_50x50_2.dat . Fig5-Energyscan-SiC-Metal3um_50x50_1.dat . Fig5-Energyscan-SiC-Metal3um_inRing_50x50_2.dat . Fig5-Energyscan-SiliconReference_Hamamatsu-P1_sample1_50x50_3_sorted.dat . Fig5-EnergyScan_SiC_metal50um_50x50_removed_saturated.dat, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterisation of SiC radiation detector technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
To cope with environments with high levels of radiation, non-silicon semiconductors such as silicon carbide detectors are being proposed for instrumentation. 4H-SiC diodes for radiation detection have been fabricated in the IMB-CNM Clean Room, for which different strategies to define the electrical contact of the implants had been implemented, in an attempt to optimise the technology for, e.g., medical applications or low energy radiation detection, as the material choice can affect the sensitivity of the device. Among these technologies, it is included an epitaxially-grown graphene layer as part of the electrical contact. In this paper, a selection of four configurations of the IMB-CNM SiC diodes are characterised in terms of radiation detector response. Photodiode performance under 20 keV X-rays irradiation in the XALOC beam line at ALBA Synchrotron is presented. Over-responses in the range of 12-19% linked to the interaction of the radiation with the metallic layers are observed. A good uniformity response as well as a good linearity at 0~V bias is reported, even in the under-depleted devices. This work exemplifies the good performance of SiC detectors fabricated at IMB-CNM specifically for low-energy X ray characterization at high X-ray intensities., This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023- 001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Dosímetros de Carburo de Silicio resistentes a la radiación para radioterapia de protones y FLASH

  • Ivan Lopez Paz
  • Fleta, Celeste
  • Ángela Henao
  • Marcio Jimenez
  • Mª Carmen Jimenez-Ramos
  • Carmen Torres-Muñoz
  • Javier García-López
  • Paula Ibañez
  • Daniel Sanchez-Parcerisa
  • Adrián Zazpe
  • Inés del Monte-Garcia
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Caracterización de nuevos dosímetros resistentes a la radiación en condiciones FLASH con electrones

  • Angela Henao
  • Iván López Paz
  • Fleta, Celeste
  • Sophie Heinrich
  • Faustino Gómez
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Innovative SiC detectors for FLASH radiotherapy

  • Angela Henao Isaza
  • Ivan Lopez Paz
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

SiC dosimetry monitor for FLASH Radiotherapy treatments

  • Angela María Henao Isaza
  • Guardiola Salmerón, Consuelo
  • Iván López Paz
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Characterization of new silicon carbide neutron detectors with thermal and fast neutrons, Pérez, M., Zamorano, F., Fleta, C., Fernández, B., Guerrero, C., Godignon, P.,Pellegrini, G., Pérez-Maroto, P., Guardiola, C. (2024, December). Characterization of new silicon carbide neutron detectors with thermal and fast neutrons [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, Carlos
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, European Union Horizon 2022 research and innovation programme under the Marie Sklodowska Curie grant agreement N◦ 101106191 [SiCNeutronFlash]. Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08. Spanish Ministry of Science, Innovation and Universities grant number CEX2023-001397-M, and by the European Union’s ERDF program (MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’ under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22., No