Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of new silicon carbide neutron detectors with thermal and fast neutrons

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, C.
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
The aim of this work is to present a characterization of a new silicon carbide (SiC) neutron detector fabricated at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC). The device is based on a 50μm thick p-n diode built in a 4H-SiC wafer. Performance studies were carried out under different neutron energy spectra, including thermal and quasi-monoenergetic fast neutrons at the CNA HiSPANoS facility. We implemented a method for the fabrication of enriched LiF conversion layers to use for the detection of thermal neutrons. The detector was proven to be capable of being used for thermal neutron detection with conversion layers of 10B and LiF. A detection efficiency of 6 ± 1% was achieved with a 25μm thick LiF conversion layer. It was also confirmed that the device can be employed for the detection of recoil nuclei and protons produced by fast neutrons. The spectra obtained experimentally were compared with PHITS simulations. This work represents the first step towards the design and fabrication of new SiC neutron detectors in the IMB-CNM-CSIC clean room with potential applications in various scientific and technological fields., This project has received funding from the European Union Horizon2022 research and innovation programme under the Marie Sklodowska-Curie grant agreement N◦101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Sub-venciones 2022 SUB-08. In addition, it has also received funding bySpanish Ministry of Science, Innovation and Universities grant num-ber CEX2023-001397-M, and by the European Union’s ERDF program(MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22. The authors would like to thank Javier Bravo, IvánLopez Paz, Xavier Ayesta, and Esteve Cot for their technical assistance,and also the staff of IMB-CNM-CSIC and CNA., With funding from the Spanish goverment through th "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Characterization of new silicon carbide neutron detectors with thermal and fast neutrons, Pérez, M., Zamorano, F., Fleta, C., Fernández, B., Guerrero, C., Godignon, P.,Pellegrini, G., Pérez-Maroto, P., Guardiola, C. (2024, December). Characterization of new silicon carbide neutron detectors with thermal and fast neutrons [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, Carlos
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, European Union Horizon 2022 research and innovation programme under the Marie Sklodowska Curie grant agreement N◦ 101106191 [SiCNeutronFlash]. Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08. Spanish Ministry of Science, Innovation and Universities grant number CEX2023-001397-M, and by the European Union’s ERDF program (MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’ under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs, Zamorano, Felipe; 2025; Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs [Data management plan]; Versión 1.0.

  • Pérez, Martín
  • Zamorano, Felipe
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Bianchini, Sebastián
  • Blostein, Juan Jerónimo
  • Lipovetzky, José
  • Fleta, Celeste
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor., Most relevant data obtained for the Varian TrueBeam (TB) 15 MV with flattening filter (FF), related to the paper: "Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs”, CSIC PIE Incorporación CT (2024ICT157); María de Maeztu Unit of Excelence CEX2023-001397-M/AEI/10.13039/501100011033; Marie Sklodowska-Curie 101106191; Spanish Nuclear Safety Council (CSN) 2022 SUB-08, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Production and characterization of deuterated bacterial nanocellulose

  • Muñoz Juan, Amanda
  • Diaz, Daniela
  • Marin Ortega, Judith
  • Murugarren, Nerea
  • Campoy Quiles, Mariano
  • Zamorano, Felipe
  • Guardiola, Consuelo
  • Pérez, Martín
  • Laromaine, Anna
“Production and characterization of deuterated bacterial nanocellulose“ CSIC digital repository collects the data published in RSC Applied Polymers in 2026 with the title “Engineering Deuterated Bacterial Cellulose via Biosynthesis for Neutron Applications” in accordance with the data availability statement of the journal. The project aimed to produce deuterated bacterial nanocellulose (dBNC) using the “film to film” protocol to reduce time and costs. The second objective was to characterize the deuterated bacterial nanocellulose films using various physicochemical techniques (FTIR, NIR, Raman, and SR-µFTIR). These techniques demonstrated the homogeneous incorporation of deuterium into the chemical structure of bacterial nanocellulose (BNC). Finally, natural and deuterated BNC were irradiated with neutrons to determine whether neutrons interact differently with deuterated BNC, paving the way for future applications of dBNC in neutron-based technologies. The data in this repository support the results presented in the publication and are organized in order of appearance: 1.-Film to Film protocol for bacterial cellulose deuteration. It summarizes the materials and steps to produce dBNC. 2.-Table1_Absorbance values. Absorbance values at each wavelength, the formula used to calculate, and the ratios (average and standard deviation). 3.-FTIR_Figure2A. FTIR spectra used for the graphic in Figure 2.A. Equipment and conditions are also described. 4. X-Ray_Figure2B. Data, equipment, and conditions for Figure 2B. 5.-NIR spectra_Figure2C. NIR spectra presented in Figure 2.C. The integrity area for each region used to calculate the crystallinity index (CRNIR) is also collected here. 6.-ZetaPotentialData. Measurements were performed to analyze the surface charge of BNC and dBNC fibers. 7.-Figure 3 RamanData. Folder with the data, equipment, and conditions used for the characterization of dBNC. 8.-SR-uFTIR_Figure4. Data, equipment, and conditions for SR-µFTIR data obtained at ALBA Synchrotron. 9.-Figure5. Neutron interaction data. Information about neutrons' interaction with BNC and dBNC, and the simulations performed at the HISPaNoS facility of the National Accelerator Center (CAN) in Sevilla. The data is presented in text files (.txt) and spreadsheets (.csv). We recommend using text editors (such as Notepad, Wordpad), MS Word or Standard PDF viewers for text files. Numerical data is presented in a spreadsheet (.csv), and we recommend using MS Excel software. The methodology is explained in detail in the accompanying publication. The equipment characteristics, software, and measurement conditions are included in each file., SR-µFTIR experiments were performed at the BL01-MIRAS beamline at ALBA Synchrotron with the collaboration of ALBA staff (ID:2020094625). We are grateful to Agustin Mihi (ICMAB-CSIC) for providing access to the spectrometer, supervising the measurements, and guiding in data analysis. This research was supported by the Spanish Ministry of Science and Innovation through the RTI2018-096273-B-I00 and PID2021-122645OB-100 projects, ‘Severo Ochoa’ Program for Center of Excellence in R&D (CEX2019-000917), the Generalitat de Catalunya (2017SGR765 grant). A.M.J. acknowledges the Ph.D. scholarship (FPU18/05190) in the framework of the Biotechnology Ph.D. program of the UAB. A.M.J. and A.L. participate in the Spanish National Research Council (CSIC) interdisciplinary platform for sustainable plastics towards a circular economy (SusPlast), the Aerogels COST ACTION (CA 18125), the EPNOE network, Conexión Nanomedicina del CSIC, and Red Nanocare 2.0. M.P. thanks funding from the European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N◦ 101106191. C.G. acknowledges the Subvenciones 2022 SUB-08 program from the Spanish Nuclear Safety Council (CSN) and the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M). Finally, the authors would like to express their gratitude to ICMAB-CSIC and CNA for their technical support., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S)., "1.-Film to Film protocol for bacterial cellulose deuteration. 2.-Table1_Absorbance values. 3.-FTIR_Figure2A. 4. X-Ray_Figure2B. 5.-NIR spectra_Figure2C. 6.-ZetaPotentialData. 7.-Figure 3 RamanData. 8.-SR-uFTIR_Figure4. 9.-Figure5. Neutron interaction data. ", Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs, Replication data for Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs

  • Zamorano, Felipe
  • Pérez, Martín
  • Fleta, Celeste
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Bianchini, Sebastián
  • Blostein, Juan Jerónimo
  • Lipovetzky, José
  • Guardiola Salmerón, Consuelo
Neutron contamination near medical linear accelerators (LINACs) has raised increasing concerns regarding secondary risks for patients undergoing photon-based radiotherapy (RT) at energies above 6 MV.Objective.In this work the aim was to evaluate in real-time the secondary neutron fluence to compare the neutron production between two widely used LINACs (Varian TrueBeam and Elekta Synergy) operating at 15 MV. Thermal neutron contributions were measured in the treatment rooms using a 10 × 10 cm2field size, flattening filter, and doses ranging from 100 to 1000 monitor units (MU) and dose rates from 100 to 600 MU min-1.Approach.An ultra-thin (20μm) silicon detector with 3D electrodes, paired with a (45 ± 5)μm thick10B-enriched conversion layer was used to quantify the thermal neutron field in both LINAC treatment rooms. The thin active volume of 20μm thick offers a high gamma rejection factor (>10-8), which is crucial for effectively isolating neutron signals in high-gamma RT environments. A customized readout electronics was developed for online measurements. The detector responses were compared with those obtained with PHITS Monte Carlo simulations using an extended model of the TrueBeam LINAC head operating at 15 MV. This model, which includes detailed head shielding for the first time, was validated with percentage depth dose data.Main results.The findings demonstrated the ability of the sensors to characterize the thermal neutron field, achieving a detection efficiency of (1.53 ± 0.02)% at a 660 keV energy threshold and operating without interference from the high intense photon background. The results show that the secondary neutron field produced by the Varian TrueBeam was approximately four times higher than that of the Elekta Synergy.Significance.These findings highlight significant differences in neutron contamination between LINAC models, thus with implications for patient safety and shielding design in RT facilities., This project has been funded by the Spanish Nuclear Safety Council (CSN) under the Subvenciones 2022 SUB-08 programme and the CSIC PIE Incorporación CT (2024ICT157). Additional funding was provided by the European Union’s Horizon 2022 research and innovation programme under the Marie Skłodowska-Curie Grant Agreement N. 101106191. The project also received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M/AEI/ 10.13039/501100011033). This work was carried out within the framework of the Doctoral Program in Physics at the Autonomous University of Barcelona, Peer reviewed