Pasar al contenido principal

DETECTORES PARA LAS MEJORAS DE ATLAS PARA EL HL-LHC

PID2021-124660OB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Timing performance and gain degradation after irradiation with protons and neutrons of Low Gain Avalanche Diodes based on a shallow and broad multiplication layer in a float-zone 35μm and 50μm thick silicon substrate

  • Currás, Esteban
  • Doblas, Albert
  • Fernández-García, Marcos
  • Flores, David
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Moll, Michael
  • Navarrete Ramos, Efrén
  • Pellegrini, Giulio
  • Vila, Iván
The high-luminosity upgrade of the ATLAS and CMS experiments includes dedicated sub-detectors to perform the time-stamping of minimum ionizing particles (MIPs). These detectors will be exposed up to fluences in the range of 1.5–2.5 × 1015 𝑛𝑒𝑞∕cm2 and require a time resolution per detecting layer of 30 ps, for non-irradiated sensors, to 50–70 ps (depending on the exposed fluences) for sensors at the end of their lifetime. To cope with these requirements, the low-gain avalanche diode (LGAD) has been chosen as the baseline detection technology. In this article, an in-depth radiation tolerance study on LGADs manufactured at IMB-CNM using a so-called shallow junction is presented. Proton irradiation at CERN-PS up to fluences of 3 × 1015 𝑛𝑒𝑞∕cm2 and neutron irradiation at JSI-Ljubljana up to 2.5 × 1015 𝑛𝑒𝑞∕cm2 were performed. Two different active thicknesses were studied: 35 μm and 50 μm. Gain degradation, operation stability, and timing performance were evaluated., This work was developed in the framework of the RD-50 collaboration and has been supported by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/), by the European Union’s ERDF program “A way of making Europe” (Grant References PID2020-113705RB-C31, PID2020-113705RB-C32, and PID2021-124660OB-C22) and by the European Union’s Horizon 2020 Research and Innovation funding program , under Grant Agreement no. 101004761 (AIDAInnova). We thank Dr. Miquel Vellvehi and Dr. Xavier Perpiña (IMB-CNM-CSIC) for their work in performing the thermographic measurements., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Spectrometric performance of SiC radiation detectors at high temperature

  • Jiménez-Ramos, M. C.
  • García-Osuna, Adrián
  • Rodríguez-Ramos, M.
  • Viezzer, Eleonora
  • Pellegrini, Giulio
  • Godignon, Philippe
  • Rafí, Joan Marc
  • Rius, Gemma
  • García López, J.
In this work, we have investigated the performance of a 4H–SiC radiation sensor in the temperature range from 25 °C to 450 °C to explore its compatibility as detector of fast ion losses in plasma diagnostic of future nuclear fusion reactors. To simulate the escape of fusion-born alpha particles in D-T (deuterium-tritium) fusion plasmas, spectroscopic measurements were carried out in a vacuum chamber by irradiating the detector with a 3.5 MeV alpha beam from a Tandem accelerator. The detector was found to have an energy resolution ≤2% over the entire temperature range analyzed. Relevantly, the excellent spectrometric capabilities of the device have allowed us to calculate from experimental data, with unprecedented accuracy, the average energy required to create a single electron-hole pair in 4H–SiC as a function of temperature., This research was funded by the Spanish Ministry of Science, Innovation and Universities grant numbers RTC-2017-6369-3 (FEDER/EU) and ICTS-2020-02 US-4 (FEDER/EU), the Regional Ministry of Economy, Knowledge, Business and University grant number US-1380791, the Spanish Ministry of Science, Innovation grant number PID 2020 116822RB-I00 and PID 2021-124660OB-C22., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterization of new silicon carbide neutron detectors with thermal and fast neutrons

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, C.
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
The aim of this work is to present a characterization of a new silicon carbide (SiC) neutron detector fabricated at the Institute of Microelectronics of Barcelona (IMB-CNM-CSIC). The device is based on a 50μm thick p-n diode built in a 4H-SiC wafer. Performance studies were carried out under different neutron energy spectra, including thermal and quasi-monoenergetic fast neutrons at the CNA HiSPANoS facility. We implemented a method for the fabrication of enriched LiF conversion layers to use for the detection of thermal neutrons. The detector was proven to be capable of being used for thermal neutron detection with conversion layers of 10B and LiF. A detection efficiency of 6 ± 1% was achieved with a 25μm thick LiF conversion layer. It was also confirmed that the device can be employed for the detection of recoil nuclei and protons produced by fast neutrons. The spectra obtained experimentally were compared with PHITS simulations. This work represents the first step towards the design and fabrication of new SiC neutron detectors in the IMB-CNM-CSIC clean room with potential applications in various scientific and technological fields., This project has received funding from the European Union Horizon2022 research and innovation programme under the Marie Sklodowska-Curie grant agreement N◦101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Sub-venciones 2022 SUB-08. In addition, it has also received funding bySpanish Ministry of Science, Innovation and Universities grant num-ber CEX2023-001397-M, and by the European Union’s ERDF program(MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22. The authors would like to thank Javier Bravo, IvánLopez Paz, Xavier Ayesta, and Esteve Cot for their technical assistance,and also the staff of IMB-CNM-CSIC and CNA., With funding from the Spanish goverment through th "Severo Ochoa Centre of Excellence" accreditation (CEX2023-001397-M), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

nLGAD gain response to low-penetrating particles

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C.
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
Detecting low-penetrating particles is fundamental for a wide range of applications in the fields of industry, medicine, and pure research. The Low Gain Avalanche Detector built on n-type substrates (nLGAD) is considered a good candidate for that, as it showed to have the potential to detect such particles with high sensitivity while avoiding the high noise levels associated with a traditional avalanche photodetector. An overview of the electrical characterization of the latest nLGAD batch fabricated at the Institute of Microelectronics of Barcelona is presented in this work. Additionally, gain response measurements for light with varying penetration depths in silicon and 600 keV protons are also presented. The results confirm the aforementioned potential of nLGADs to detect low-penetrating particles in silicon. Additionally, it was observed that the gain response of the devices is not only dependent on the penetration depth of the studied particles, but also on the nature and flux of the source., This work has been funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32. Also, it was supported by the following European funding programs: European Union’s Horizon 2020 Research and Innovation (under Grant Agreement No. 101004761, AIDAInnova) and NextGenerationEU (PRTR-C17.I1). M. Carmen Jimenez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has also been partially financed by the project ref. ASTRO21/1.1/1 with financing from the European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla, Spain ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Impact of neutron irradiation on LGADs with a carbon-enriched shallow multiplication layer: Degradation of timing performance and gain

  • Navarrete Ramos, Efrén
  • Duarte Campderros, J.
  • Fernández-García, Marcos
  • Gómez, Gervasio
  • González, Javier
  • Hidalgo, Salvador
  • Jaramillo, R.
  • Martínez Ruiz del Arbol, P.
  • Moll, Michael
  • Quintana San Emeterio, Cristian
  • Sikdar, A. K.
  • Vila, Iván
  • Villegas, Jairo
In this radiation tolerance study, Low Gain Avalanche Detectors (LGADs) with a carbon-enriched broad and shallow multiplication layer were examined in comparison to identical non-carbonated LGADs. Manufactured at IMB-CNM, the sensors underwent neutron irradiation at the TRIGA reactor in Ljubljana, reaching a fluence of 1.5 × 10 15neqcm−2. The results revealed a smaller deactivation of boron and improved resistance to radiation in carbonated LGADs. The study demonstrated the potential benefits of carbon enrichment in mitigating radiation damage effects, particularly the acceptor removal mechanism, reducing the acceptor removal constant by more than a factor of two. Additionally, time resolution and collected charge degradation due to irradiation were observed, with carbonated samples exhibiting better radiation tolerance. A noise analysis focused on baseline noise and spurious pulses showed the presence of thermal-generated dark counts attributed to a too narrow distance between the gain layer end and the p-stop implant at the periphery of the pad for the characterized LGAD design; however, without significant impact of operation performance., This work was developed in the framework of the CERN RD50/DRD3 collaboration and has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C31, PID2020-113705RB-C32 and PID2021-124660OB-C22. Also, it was supported by the following European funding programs: the European Union’s Horizon 2020 Research and Innovation (under Grant Agreement No. 101004761, AIDAInnova) and NextGenerationEU (PRTR-C17.I1). This work was also been developed in the framework of the “Ayudas Maria Zambrano para la atraccion de talento internacional”, co-funded by the Ministry Of University of Spain and the European Union NextGenerationEU, reference code: C21.I4.P1; under the framework of “Ayudas para contratos predoctorales para la formación de doctores 2019”, co-funded by the European Social Fund program “El FSE invierte en tu futuro” with grant reference: PRE2019-087514; and the Plan Complementario en el Área de Astrofísica y Física de Altas Energías, financed by Next Generation EU funds , including the Recovery and Resilience Mechanism (MRR), the Recovery, Transformation and Resilience Plan (PRTR) and the Autonomous Community of Cantabria., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Characterization of new silicon carbide neutron detectors with thermal and fast neutrons, Pérez, M., Zamorano, F., Fleta, C., Fernández, B., Guerrero, C., Godignon, P.,Pellegrini, G., Pérez-Maroto, P., Guardiola, C. (2024, December). Characterization of new silicon carbide neutron detectors with thermal and fast neutrons [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Fernández, Begoña
  • Guerrero, Carlos
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Pérez-Maroto, Pablo
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, European Union Horizon 2022 research and innovation programme under the Marie Sklodowska Curie grant agreement N◦ 101106191 [SiCNeutronFlash]. Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08. Spanish Ministry of Science, Innovation and Universities grant number CEX2023-001397-M, and by the European Union’s ERDF program (MCIN/AEI/10.13039/501100011033/) ‘‘A way of making Europe’’ under grant references RTC-2017-6369-3 (FEDER/EU), and PID2021-124660OB-C22., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for The effects in fabrication and performance of carbon doping on IMB-CNM manufactured LGADs, Jairo Villegas, Viveka Gautam, Neil Moffat, Lucía Castillo, Giulio Pellegrini, Sebastian Grinstein, Salvador Hidalgo, The effects in fabrication and performance of carbon doping on IMB-CNM manufactured LGADs [Data management plan]; versión 1

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The effects in fabrication and performance of carbon doping on IMB-CNM manufactured LGADs

  • Villegas, Jairo
  • Gautam, Viveka
  • Moffat, Neil
  • Castillo, Lucía
  • Pellegrini, Giulio
  • Grinstein, Sebastian
  • Hidalgo, Salvador
Over the past few years, Low Gain Avalanche Detectors (LGAD) have shown excellent timing performance with the hope to be utilized for 4D-tracking of high-energy charged particles. LGADs co-doping with carbon has been demonstrated to be a key factor in the enhancement of their performance as detectors with intrinsic amplification in harsh radiation environments. A wide characterization, before irradiation, of the latest carbonated LGADs fabricated at the IMB-CNM is presented in this work. The results show that the addition of carbon improves the gain of the devices, given a specific bias voltage, but only up to a certain point. Moreover, a comprehensive study of how carbonation enhances the diffusion suppression of dopants in silicon sensors during its fabrication is also presented., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for nLGAD gain response to low-penetrating particles, Villegas, J., Torres, C., Manojlovic, M., Jimenez-Ramos, M. C., Moffat, N., Lopez, J. G., & Hidalgo, S. (2025, March). nLGAD gain response to low-penetrating particles [Data management plan]; versión 1

  • Villegas, Jairo
  • Torres Muñoz, Carmen
  • Manojlovic, Milos
  • Jiménez-Ramos, M. C
  • Moffat, Neil
  • García López, J.
  • Hidalgo, Salvador
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with nLGAD silicon detectors fabricated at IMB-CNM-CSIC for the paper: "nLGAD gain response to low-penetrating particles”, Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: CEX2023-001397-M, PID2020-113705RB-C32, PID2021-124660OB-C22, PDC2021-121718-C32 and PDC2023-145925-C32 European Union’s Horizon 2020 Research and Innovation. Grant Agreement No. 101004761 (AIDAInnova) NextGenerationEU, Spain (PRTR-C17.I1). CNA is also partially funded by the ASTRO21/1.1/1 (European Union- NextGenerationEU, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, Spain, the Department of University, Research and Innovation of the Junta de Andalucia and the University of Sevilla)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Position-resolved charge collection of silicon carbide detectors with an epitaxially-grown graphene layer

  • López Paz, Iván
  • Godignon, Philippe
  • Moffat, Neil
  • Pellegrini, Giulio
  • Rafí, Joan Marc
  • Rius, Gemma
Silicon carbide (SiC) has outstanding physical properties therefore, diodes based on SiC are being considered for many radiation detection applications such as particle accelerator experiments and medical dosimetry. Moreover, by reducing the metal on the surface of the diode there is the potential to enhance its performance in some fields where the presence of metal is detrimental. To this end, SiC detectors with an epitaxially-grown graphene layer (EG), that substitutes the metallic contact, in the sensitive region were produced at IMB-CNM, profiting from the conductivity of the mono-atomic layer material. To isolate the effect of the graphene on the charge collection, samples without graphene were produced in parallel. In this paper, the effect of EG on Silicon Carbide p-in-n radiation detectors is studied in terms of charge collection with a radioactive source and by means of the transient current technique (TCT), which allows for position-dependent signal formation analysis. As a result of the former, we show the capability of the EG-SiC sensor for charge collection after signal integration, to a resolution close to that of a sensor fully metallised. Moreover, from the TCT studies, we observe uniform charge collection across the active region, as well as an up-to ∼ 40% transient amplitude damping which, compared with the ∼ 90% on the sample containing no metallic contact, proves that the presence of graphene benefits the performance of the device and that the technology is viable for radiation detection as an alternative to metal., This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D.Grant references: PID2021-124660OB-C22 and by the European Union\u2019s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova). Support from Ayudas Ramon y Cajal Ref. RYC-2016-21412 is also acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Position-resolved charge collection of silicon carbide detectors with an epitaxially-grown graphene layer, Lopez Paz, I., Godignon, P., Moffat, N. et al. Position-resolved charge collection of silicon carbide detectors with an epitaxially-grown graphene layer. Sci Rep 14, 10376 (2024)

  • Lopez Paz, Ivan
  • Godignon, Philippe
  • Moffat, Neil
  • Pellegrini, Giulio
  • Rafí, Joan Marc
  • Rius, Gemma
Silicon carbide (SiC) has outstanding physical properties therefore, diodes based on SiC are being considered for many radiation detection applications such as particle accelerator experiments and medical dosimetry. Moreover, by reducing the metal on the surface of the diode there is the potential to enhance its performance in some fields where the presence of metal is detrimental. To this end, SiC detectors with an epitaxially-grown graphene layer (EG), that substitutes the metallic contact, in the sensitive region were produced at IMB-CNM, profiting from the conductivity of the mono-atomic layer material. To isolate the effect of the graphene on the charge collection, samples without graphene were produced in parallel. In this paper, the effect of EG on Silicon Carbide p-in-n radiation detectors is studied in terms of charge collection with a radioactive source and by means of the transient current technique (TCT), which allows for position-dependent signal formation analysis. As a result of the former, we show the capability of the EG-SiC sensor for charge collection after signal integration, to a resolution close to that of a sensor fully metallised. Moreover, from the TCT studies, we observe uniform charge collection across the active region, as well as an up-to ∼40% transient amplitude damping which, compared with the ∼90% on the sample containing no metallic contact, proves that the presence of graphene benefits the performance of the device and that the technology is viable for radiation detection as an alternative to metal. © The Author(s) 2024., This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D.Grant references: PID2021-124660OB-C22 and by the European Union\u2019s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova). Support from Ayudas Ramon y Cajal Ref. RYC-2016-21412 is also acknowledged., The transient signals obtained under the triple-alpha radioactive source set-up are shown in Fig. 5. The waveforms obtained from all samples showcase a dip after the main transient pulse attributed to an impedance mismatch, causing a reflection. The integration window in Sample-1M was chosen before this undershoot, since the pulses from charge collection are faster. However, as the signals are longer in the other samples, the integration window for the charge determination is chosen longer, which in turn results in an under-estimation of the charge collection. Amplitude distribution for all samples under a bias voltage of -500 V are shown in Fig. 6 (left). Notably, Sample-1 has an overall lower amplitude distribution, although Sample-1M is the only detector showcasing the three peaks expected from the three alpha particle energies from the radioactive source. However - after integration - the same features appear in Sample-1G, as shown in Fig. 6 (right). As it will be observed in the following sections in more detail, the apparent charge collection loss in Sample-1 is a result of the higher resistance observed by the transient signal before reaching the bias ring with respect to the other samples, which reduces the waveform amplitudes away from it, to the point where noise is a large contribution in the integration. A 30 ns extra integration window was used in Sample-1 in order to recover charge levels comparable to Samples-1G and -1M. The same damping effect is seen in Sample-1G to a lesser degree., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of 3D sensors for fast timing applications

  • Diehl, Leena
  • Argyropoulos, Spyros
  • Ferrer, Oscar
  • Hauser, Marc
  • Jakobs, Karl
  • King, Montague
  • Lex, Fabian
  • Kramberger, Gregor
  • Parzefall, Ulrich
  • Pellegrini, Giulio
  • Schwemmbauer, Christina
  • Sperlich, Dennis
Novel collider experiments demand an increased performance of the silicon detectors used, such as withstanding up to 1×10<sup>17</sup>n<inf>eq</inf>/cm<sup>2</sup> in unprecedented pile-up conditions and providing time resolution around 10 ps. Currently, Low Gain Avalanche Diodes (LGADs) are the standard, achieving resolutions below 30 ps. However, their limited radiation hardness is an area of ongoing research. As an alternative to LGADs, 3D sensors are interesting due to their proven radiation hardness. In 3D sensors, where the columns are etched into the sensor from the top (junction columns) and the back (ohmic columns), the drift distances can be very short, the depletion voltage is low and the electric field can be high, resulting in fast and short signals. In this study, the time resolution of different 3D pixel and strip sensors is investigated with signals generated by electrons as well as an infra-red laser. TCT Timing measurements allow to study the position dependence of the time resolution, which is interesting for 3D sensors due to their complex electric field structure. Position-timing maps prove the direct correlation between time resolution and electric field. The time resolution of 3D sensors before and after irradiation is presented, showing that 3D sensors can reach the time resolution of standard 50μm LGADs, which is limited by Landau fluctuations. In addition, the results demonstrate that the radiation-induced performance degradation in 3Ds is less severe than in LGADs. Furthermore, initial results from a production run of dedicated fast 3D sensors which have recently been produced at CNM as a common RD50 project will be presented. Finally, the option of using fast 3D sensors as timing detectors in future collider experiments will be discussed., Funding text 1 This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union's ERDF program \u201CA way of making Europe\u201D. Grant references: PID2021-124660OB-C22. Also, it was funded by the European Union's Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova) and partially by the RD50 CERN collaboration. Funding text 2 This work has been funded by the Spanish Ministry of Science and Innovation ( MCIN/AEI/10.13039/501100011033/ ) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D . Grant references: PID2021-124660OB-C22 . Also, it was funded by the European Union\u2019s Horizon 2020 Research and Innovation funding program , under Grant Agreement No. 101004761 (AIDAInnova) and partially by the RD50 CERN collaboration ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC, Perez, M.; Zamorano, F.; Fleta, C.; Muñoz-Montplet, C.; Jurado-Bruggeman, D.; Jimenez, M.; Guardia, P.; Grabulosa-Morera, G.; Morales-Pérez, R.; Rius, G.; Godignon, P.; Pellegrini, G.; Guardiola, C.; Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC [Data management plan]; versión 1

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Jimenez, Marcio
  • Guardia, Pablo
  • Grabulosa-Morera, Gina
  • Morales-Pérez, Roger
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper "Evaluation of a silicon carbide P–N diode for thermal neutron detection in a radiotherapy LINAC", European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N◦ 101106191; Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08 Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/). European Union ERDF program ’A way of making Europe’. Grant references: PID2021-124660OB-C22. Spanish government through the ’María de Maeztu Unit of Excelence’ accreditation (CEX2023-001397-M). MCIN/AEI/10.13039/501100011033 (Grant No. CNS2022-13558).'Severo Ochoa' Programme for Center of Excellence in R&D funded by MCIN and by FEDER, “A way of making Europe” (Grant No. CEX2023-001263-S). P. G. acknowledges financial support from the Ramon y Cajal program funded by the MCIN/AEI/10.13039/501100011033 and the “FSE invierte en tu futuro” (Grant No. RYC2019-028414)., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Investigating irradiation effects and space charge sign inversion in n-type Low Gain Avalanche Detectors

  • Kraus, Veronika
  • Biveinytė, Margarita
  • Fernández-García, Marcos
  • Hidalgo, Salvador
  • Moll, Michael
  • Villegas, Jairo
  • Wiehe, Moritz
Low Gain Avalanche Detectors built on n-type substrate (nLGADs) have been developed by IMB-CNM to enhance the detection of low-penetrating particles, with a wide range of applications from medicine, industry to synergies with developments for high-energy physics (HEP). In this work, irradiation effects on nLGADs were investigated through proton irradiation at the CERN PS-IRRAD facility up to proton fluences of 1 x 1014 cm−2. Electrical characterization before and after irradiation reveals space charge sign inversion of the n-type bulk, leading to significant modifications in the depletion behavior and electric field distribution. Utilizing UV TCT and TPA-TCT measurements, the impact of irradiation on the electric fields and the gain are studied in more detail, confirming a change of sensor depletion and a reduced electric field in the gain layer. The results suggest that donor removal in nLGADs is stronger pronounced already at lower fluences compared to acceptor removal in traditional p-type LGADs. These findings provide not only first insights into the effects of irradiation on nLGADs but also contribute to the development of methods to quantify the donor removal., This project has received funding from the European Union’s Horizon Europe Research and Innovation program under Grant Agreement No 101057511 (EURO-LABS). We thank IMB-CNM for the samples, which have been funded by the Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe” (Grant references: PID2020-113705RB-C32, PID2021-124660OB-C22)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of a silicon carbide P-N diode for thermal neutron detection in a radiotherapy LINAC

  • Pérez, Martín
  • Zamorano, Felipe
  • Fleta, Celeste
  • Muñoz-Montplet, Carles
  • Jurado-Bruggeman, Diego
  • Jiménez, Marcio
  • Guardia, Pablo
  • Grabulosa-Morera, Gina
  • Morales-Pérez, Roger
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Guardiola, Consuelo
Accurate neutron detection in mixed photon-neutron and pulsed radiation fields is technically challenging, impacting industrial and medical applications. This paper presents the first measurements of thermal neutrons in conventional radiotherapy accelerators using a silicon carbide (SiC) P-N diode with different neutron converters. SiC detectors enable real-time estimation of secondary thermal neutron contributions, crucial for emerging radiotherapy techniques requiring precise neutron fluence monitoring. Beyond medical applications, the presented detectors show potential for neutron dosimetry, radiation monitoring, nuclear safety, and scientific research. The SiC diode active detection layer is less than 30 µm thick, and provides excellent gamma rejection ([Formula: see text]), allowing discrimination of neutrons-induced events in mixed radiation fields. Experimental tests conducted on a TrueBeam radiotherapy LINAC demonstrated a thermal neutron detection efficiency of (4.32 ± 0.02)% for a (50 ± 10) µm thick [Formula: see text]LiF neutron converter. The detector, placed at 1.2 m from the accelerator isocenter, was used to measure neutron fluences at different monitor unit (MU) rates, ranging from 100 to 600 MU/min, with the LINAC operating at 15 MV. Under these conditions, the detector exhibited good linearity, without saturation or dead time effects., This project has received funding from the European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08, and by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union ERDF program ’A way of making Europe’. Grant references: PID2021-124660OB-C22. This work has also been founded by the Spanish government through the ’María de Maeztu Unit of Excelence’ accreditationCEX2023-001397-M, funded by MICIU/AEI/10.13039/501100011033. This work was partially funded by the MCIN/AEI/10.13039/501100011033 (Grant No. CNS2022-13558), and the ‘Severo Ochoa’ Programme for Center of Excellence in R&D funded by MCIN and by FEDER, “A way of making Europe” (Grant No. CEX2023-001263-S). P. G. acknowledges financial support from the Ramon y Cajal program funded by the MCIN/AEI/10.13039/501100011033 and the “FSE invierte en tu futuro” (Grant No. RYC2019-028414). The authors thank Javier Bravo, Iván Lopez Paz, Xavier Ayesta, and Esteve Cot for their technical assistance, and also the staff of IMB-CNM-CSIC and ICO-Girona., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Experimental Evaluation of Silicon Carbide P-N Detectors Under Thermal and Fast Neutron Irradiation at the RA-6 Nuclear Research Reactor, Martín Pérez; Juan Jerónimo Blostein; Felipe Zamorano; Celeste Fleta; Julio Marín; Giulio Pellegrini; Consuelo Guardiola, Experimental Evaluation of Silicon Carbide P-N Detectors Under Thermal and Fast Neutron Irradiation at the RA-6 Nuclear Research Reactor [Data management plan]; versión 1

  • Pérez, Martín
  • Blostein, Juan Jerónimo
  • Zamorano, Felipe
  • Fleta, Celeste
  • Marín, Julio
  • Pellegrini, Giulio
  • Guardiola Salmerón, Consuelo
There will not be restrictions to use the generated data after its publication, but external users will be asked to cite the source and/or the papers properly, and the redistribution of the data must be authorized by the researcher/supervisor. The identity of the person accessing the data will be ascertained with the following questionnaire, there won't be a need for a data access committee., Raw data obtained with SiC neutron detectors for the paper: "Characterization of new silicon carbide neutron detectors with thermal and fast neutrons”, This project has received funding from the European Union Horizon 2022 research and innovation program under the Marie Sklodowska-Curie grant agreement N°101106191. This work has also been funded by the Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08, and by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union ERDF program ’A way of making Europe’. Grant references: PID2021-124660OB-C22. This work has also been founded by the Spanish government through the ’María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M). This work was partially funded by the MCIN/AEI/10.13039/501100011033 (Grant No. CNS2022-13558), and the ‘Severo Ochoa’ Programme for Center of Excellence in R&D funded by MCIN and by FEDER, “A way of making Europe” (Grant No. CEX2023-001263-S). This work has also been funded by the projects PICT-2020-01016 and ICT-2020-03065, ANPCyT; PIP CONICET 11220200103237; and SIIP UNCuyo Cód. 06/C055-T1, Argentina., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gain Response and Ion Beam-Induced Donor Removal in nLGAD Detector: Global Gain Quenching

  • Manojlovic, Milos
  • Crnjac, Andreo
  • Moffat, Neil
  • Villegas, Jairo
  • Pintilie, Ioana
  • Cabruja, Enric
  • Pellegrini, Giulio
  • Hidalgo, Salvador
This study investigates the response of n-type low-gain avalanche detectors (nLGADs) to local ion-beam irradiation with low-penetrating 1.285-MeV gallium ions, focusing on charge collection efficiency (CCE) and gain degradation. Using the transient current technique (TCT), we present charge collection maps before and after local irradiation. A 404-nm blue laser was used in postcharacterization, with no signal detected in the damaged zones after irradiation, suggesting significant charge trapping. The results reveal a pronounced vulnerability of nLGADs, with significant gain loss observed at fluences as low as 4 × 10<sup>9</sup> ions/cm<sup>2</sup>. This study confirms that a donor removal mechanism occurs at low fluences, and we hypothesize that this effect is linked to a vacancy-mediated mechanism. In addition, we report a global reduction in CCE, suggesting a long-range impact on electric field triggered by local defects. This phenomenon is referred to as the global gain quenching (GGQ). Simulations of the electric field provide further confirmation of GGQ’s occurrence., This work was supported in part by the Spanish Ministry of Science, Innovation and Universities, under Grant MICIU/AEI/10.13039/501100011033; in part by the European Regional Development Fund (ERDF) Program “A Way of Making Europe” under Grant CEX2023-001397-M, Grant PID2021-124660OB-C22, Grant DC2021-121718-C32, Grant PID2023-148418NB-C42, and Grant PDC2023-145925-C32; and in part by the European Union’s Horizon 2020 Research and Innovation Funding Program (AIDAInnova) under Grant Agreement 101004761 and Project IFA-CERN 07/2024., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Potential of Low Gain Avalanche Detectors (LGAD) for Plasma Diagnostics in pB Fusion Experiments

  • Manojlovic, Milos
  • Moffat, Neil
  • Lastovicka-Medin, Gordana
  • Perez, Martin
  • Fernández Martínez, Pablo
  • Cabruja Casas, Enric
  • Hidalgo, Salvador
  • Pellegrini, Giulio
This work has been funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union’s ERDF program “A way of making Europe”. Grant references: PID2020-113705RB-C32 and PID2021-124660OB-C22. Also, it was funded by the European Union’s Horizon 2020 Research and Innovation funding program, under Grant Agreement No. 101004761 (AIDAInnova)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Timing parameters of 3D Si sensors characterized by Two Photon Absorption-Transient Current Technique

  • Lastovicka-Medin, G.
  • Kramberger, G.
  • Velkovska, I.
  • Pellegrini, Giulio
  • Moffat, Niel
  • Manna, Maria
  • Rebarz, M.
3D silicon sensors offer excellent radiation hardness and intrinsic time resolution, making them suitable for demanding applications such as those at the High-Luminosity Large Hadron Collider. Columnar electrode pixel detectors are already in use in ATLAS experiment and they are alternative for trench-type sensors which achieve time resolutions near 10 ps, even under extreme irradiation but face fabrication challenges. This study compares the latest 3D silicon sensors developed at Centre Nacional de Microelectrònica (CNM) through the RD50 collaboration, focusing on evaluating how electrode geometry (square vs. hexagonal) affects timing parameters of the signal: Time-of-Arrival (ToA) and Rising Time (RT). Presented results demonstrate Two-Photon Absorption Transient Current Technique (TPA-TCT) as an excellent 3D diagnostic tool for timing non-uniformity caused by electric field inhomogeneity. We present spatially-resolved measurements of ToA and RT as function of bias voltage and laser power across sensor depth., The authors acknowledge the use of the ELI Beamlines Facility, Extreme Light Infrastructure ERIC. The authors acknowledge also the AIDAinnova project (Advancement and Innovation for Detectors atAccelerators); this research has received funding from the European Union\u2019s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. Authors acknowledge also the project \u201CTAIDA: Technological Advancement and Innovation for Detectors at Accelerators\u201D, Contract No. 0402- 082/23-1740/5 (funding agency: Ministry of Education, Science and Innovation in Montenegro). This work has been also funded by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) and by the European Union\u2019s ERDF program \u201CA way of making Europe\u201D. Grant references: PID2021-124660OB-C22., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A graphene-on-silicon photodetector for low penetrating radiation

  • Moffat, Neil
  • Soto-Oton, J. A.
  • Rius, Gemma
  • Cabruja Casas, Enric
  • Pellegrini, Giulio
We introduce an innovative graphene-on-silicon photodiode designed for low penetrating radiation. Its standout feature lies in its remarkably-thin dead layer in the entrance window, setting it apart from existing photodetectors. Conventional photodetectors suffer from sensitivity limitations in the low wavelength or energy, respectively, for light or particles, due to their shallow penetration depth. Most conventional photodiodes employ a junction implant which suffers from recombination of low-penetrating photons/particles within the dead layer. Instead, we utilise the nearly transparent properties of single-layer graphene to create a depletion layer that minimises the dead layer. We combine a single junction ring (highly doped [Formula: see text] bias ring) with single-layer graphene. The graphene acts as a field plate, extended over the junction ring and covering the entire entrance window (5×5 [Formula: see text] active area), while being electrically isolated by an ultrathin, high K dielectric layer. In operation, the photodiode undergoes depletion upon applying a reverse bias as expected, which primarily occurs within the region beneath the field plate. We conducted Transient Current Technique measurements as the best method to assess the charge collection uniformity of the device. Remarkably, the results reveal a consistent total 100% uniformity across the entire detector area. Nevertheless, while the collection time is position-dependent, increasing as the laser incidence point moves farther away from the bias ring, responsivity measurements show excellent response in both the deep ultra violet and vacuum ultra violet regions with ≥ 100% external quantum efficiency at wavelengths below 150 nm., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been financed by the Spanish Ministry of Science and Innovation (MICIN) through the Particle Physics National Program RTI2018-094906-B-C22. This work was also supported by Ayudas Ramon y Cajal, Grant Ref. RYC-2016-21412 and this work has been financed by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) Project references: SPID202000X118404SV1, PID2020-118275RB-C22, PID2021-124660OB-C22, PDC2023-145815-C22. This work has received funding by the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. All the manufacturing was performed at the IMB-CNM clean room facilities, member of the Spanish ICTS Network MICRONANOFABS partially supported by MICIN and FEDER funds. The authors thank the Experimental Neutrino Group at IFIC (CSIC–UV), Spain, for providing access to their optical laboratory and equipment, acquired with the support of the Ministerio de Ciencia, Innovación y Universidades (MICIN) and funding from the European Union NextGenerationEU (PRTR-C17.I01), as well as the Generalitat Valenciana, Project (IFIC-NuLight), ASFAE/2022/029., Peer reviewed