- Moffat, Neil
- Soto-Oton, J. A.
- Rius, Gemma
- Cabruja Casas, Enric
- Pellegrini, Giulio
We introduce an innovative graphene-on-silicon photodiode designed for low penetrating radiation. Its standout feature lies in its remarkably-thin dead layer in the entrance window, setting it apart from existing photodetectors. Conventional photodetectors suffer from sensitivity limitations in the low wavelength or energy, respectively, for light or particles, due to their shallow penetration depth. Most conventional photodiodes employ a junction implant which suffers from recombination of low-penetrating photons/particles within the dead layer. Instead, we utilise the nearly transparent properties of single-layer graphene to create a depletion layer that minimises the dead layer. We combine a single junction ring (highly doped [Formula: see text] bias ring) with single-layer graphene. The graphene acts as a field plate, extended over the junction ring and covering the entire entrance window (5×5 [Formula: see text] active area), while being electrically isolated by an ultrathin, high K dielectric layer. In operation, the photodiode undergoes depletion upon applying a reverse bias as expected, which primarily occurs within the region beneath the field plate. We conducted Transient Current Technique measurements as the best method to assess the charge collection uniformity of the device. Remarkably, the results reveal a consistent total 100% uniformity across the entire detector area. Nevertheless, while the collection time is position-dependent, increasing as the laser incidence point moves farther away from the bias ring, responsivity measurements show excellent response in both the deep ultra violet and vacuum ultra violet regions with ≥ 100% external quantum efficiency at wavelengths below 150 nm., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been financed by the Spanish Ministry of Science and Innovation (MICIN) through the Particle Physics National Program RTI2018-094906-B-C22. This work was also supported by Ayudas Ramon y Cajal, Grant Ref. RYC-2016-21412 and this work has been financed by the Spanish Ministry of Science and Innovation (MCIN/AEI/10.13039/501100011033/) Project references: SPID202000X118404SV1, PID2020-118275RB-C22, PID2021-124660OB-C22, PDC2023-145815-C22. This work has received funding by the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. All the manufacturing was performed at the IMB-CNM clean room facilities, member of the Spanish ICTS Network MICRONANOFABS partially supported by MICIN and FEDER funds. The authors thank the Experimental Neutrino Group at IFIC (CSIC–UV), Spain, for providing access to their optical laboratory and equipment, acquired with the support of the Ministerio de Ciencia, Innovación y Universidades (MICIN) and funding from the European Union NextGenerationEU (PRTR-C17.I01), as well as the Generalitat Valenciana, Project (IFIC-NuLight), ASFAE/2022/029., Peer reviewed