DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación
Artículo científico (JournalArticle)
Conceptual design of the ITER fast-ion loss detector
et al., A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices., This research was supported in part by the Spanish Ministry of Economy and Competitiveness (Grant Nos. RYC2011-09152, FIS2015-69362-P, and ENE2012- 31087) and the Marie Curie FP7 Integration Grant (No. PCIG11-GA2012-321455)., Peer Reviewed