Pasar al contenido principal

NEUTRONES, INSTRUMENTACION NUCLEAR E INVESTIGACION RELACIONADA CON TERAPIA CON PROTONES EN EL CNA E INSTALACIONES INTERNACIONALES

RTI2018-098117-B-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE SEVILLA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 33
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Thin film nanostructuring at oblique angles by substrate patterning

  • Muñoz Piña, S.
  • Alcaide, A.M.
  • Limones Ahijón, B.
  • Oliva Ramírez, M.
  • Rico, V.
  • Alcalá Penadés, Germán
  • González, M.U.
  • García Martín, J.M.
  • Álvarez, R.
  • Wang, D.
  • Schaaf, P.
  • González Elipe, A.R.
  • Palmero, A.
It is demonstrated that, besides classical nanocolumnar arrays, the oblique angle geometry induces the growth of singular structures in the nanoscale when using wisely designed patterned substrates. Well-ordered array of crosses, cylindrical nanorods or hole structures arranged in square or hexagonal regular geometries are reported as examples, among others. The fundamental framework connecting substrate topography and film growth at oblique angles is presented, allowing the use of substrate patterning as a feasible thin film nanostructuring technique. A systematic analysis of the growth of TiO2 thin films on 4 different lithographic patterned substrates in 4 different scale lengths is also presented. A first conclusion is the existence of a height-based selective growth in the initial stages of the deposition, by which the film preferentially develops on top of the tallest substrate features. This behavior is maintained until the film reaches a critical thickness, the so-called Oblivion Thickness, above which the film topography becomes gradually independent of the substrate features. A general formula relating the spatial features of the pattern, the coarsening exponent and the Oblivion Thickness has been deduced.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Hybrid compton-PET imaging for ion-range verification: a preclinical study for proton, helium, and carbon therapy at HIT

  • Balibrea-Correa, Javier
  • Lerendegui-Marco, Jorge
  • Ladarescu, Ion
  • Guerrero, Carlos
  • Rodríguez-González, Teresa
  • Jiménez-Ramos, Maria del Carmen
  • Quesada, Jose Manuel
  • Bauer, Julia
  • Brons, Stephan
  • Domingo-Pardo, César
  • Morell-Ortega, Sergio|||0009-0001-7639-2915
[EN] Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and researched methodologies, both of them with their own advantages and challenges. Thus far, both of them have been explored for ion-range verification in an independent way. However, the simultaneous combination of PET and PGI within the same imaging framework may open-up the possibility to exploit more efficiently all radiative emissions excited in the tissue by the ion beam. Here, we report on the first preclinical implementation of an hybrid PET-PGI imaging system, hereby exploring its performance over several ion beam species (H, He and C), energies (55¿275 MeV) and intensities ( - ions/spot), which are representative of clinical conditions. The measurements were carried out using the pencil-beam scanning technique at the synchrotron accelerator of the heavy ion therapy center in Heidelberg utilizing an array of four Compton cameras in a twofold front-to-front configuration. The results demonstrate that the hybrid PET-PGI technique can be well suited for relatively low energies (55¿155 MeV) and beams of protons. On the other hand, for heavier beams of helium and carbon ions at higher energies (155¿275 MeV), range monitoring becomes more challenging owing to large backgrounds from additional nuclear processes. The experimental results are well understood on the basis of realistic Monte Carlo calculations, which show a satisfactory agreement with the measured data. This work can guide further upgrades of the hybrid PET-PGI system toward a clinical implementation of this innovative technique., This work derives from fundamental research carried out with funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation program (ERC Consolidator Grant project HYMNS, with grant agreement No. 681740) and part of this work has been funded under ERC Proof-of-Concept Grant GNVISION (Grant Agreement 101113330). The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PDC2021-121536-C21, PID2019-104714GB-C21 and RTI2018-098117-B-C21. We acknowledge support from the Severo Ochoa Grant CEX2023-001292-S funded by MCIU/AEI. T. Rodriguez-Gonzalez acknowledges the Spanish FPI predoctoral grant. J. Balibrea-Correa is supported by grant ICJ220-045122-I and J. Lerendegui-Marco is supported by grant FJC2020-044688-I funded by MCIN/AEI/10.13039/501100011033 and CIAPOS/2022/020 funded by MICIN/AEI and Generalitat Valenciana. Ion Ladarescu was funded by the R&D grant PDC2022-133382-I00, funded by the Spanish Ministry of Science (MCIN/AEI/10.13039/501100011033). M.C. Jiménez-Ramos acknowledges the support to this work through a VI PPIT-US contract. We would like to thank the crew at the Electronics Laboratory of IFIC, in particular Manuel Lopez Redondo and Jorge Nácher Arándiga for their excellent and efficient work prototyping and manufacturing customized PCBs for this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The PENELOPE Physics Models and Transport Mechanics. Implementation into Geant4

  • Asai, Makoto
  • Cortés-Giraldo, Miguel A.
  • Giménez Gómez, Vicent
  • Salvat, Francesc
  • Giménez-Alventosa, Vicent|||0000-0003-1646-6094
[EN] A translation of the penelope physics subroutines to C++, designed as an extension of the Geant4 toolkit, is presented. The Fortran code system penelope performs Monte Carlo simulation of coupled electron-photon transport in arbitrary materials for a wide energy range, nominally from 50 eV up to 1 GeV. Penelope implements the most reliable interaction models that are currently available, limited only by the required generality of the code. In addition, the transport of electrons and positrons is simulated by means of an elaborate class II scheme in which hard interactions (involving deflection angles or energy transfers larger than pre-defined cutoffs) are simulated from the associated restricted differential cross sections. After a brief description of the interaction models adopted for photons and electrons/positrons, we describe the details of the class-II algorithm used for tracking electrons and positrons. The C++ classes are adapted to the specific code structure of Geant4. They provide a complete description of the interactions and transport mechanics of electrons/positrons and photons in arbitrary materials, which can be activated from the G4ProcessManager to produce simulation results equivalent to those from the original penelope programs. The combined code, named PenG4, benefits from the multi-threading capabilities and advanced geometry and statistical tools of Geant4., Financial support from the Spanish Ministerio de Ciencia, Innovacion y Universidades/Agencia Estatal de Investigacion/European Regional Development Fund, European Union, (projects nos. RTI2018-098117-B-C21 and RTI2018-098117-B-C22) is gratefully aknowledged. The work of VA was supported by the program Ayudas para la contratacion de personal investigador en formacion de caracter predoctoral, programa VALi+d under grant number ACIF/2018/148 from the Conselleria dEducacio of the Generalitat Valenciana and the Fondo Social Europeo (FSE). VG acknowledges partial support from FEDER/MCIyU-AEI under grant FPA2017-84543-P, by the Severo Ochoa Excellence Program under grant SEV-2014-0398 and by Generalitat Valenciana through the project PROMETEO/2019/087.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Production of carbon-11 for PET preclinical imaging using a high-repetition rate laser-driven proton source

  • Peñas, Juan
  • Alejo, Aaron
  • Bembibre, Adrian
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, Carlos
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán-Callado, María Ángeles
  • Puyuelo-Valdés, Pilar
  • Benlliure, José
  • Seimetz, Michael
[EN] Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the frst time the use of a high-repetition rate, ultraintense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10¿14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11B(p,n)11C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Signifcant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-theart technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the Maria de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovacion y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by 'la Caixa' Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by 'European Union NextGenerationEU'.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Novel solid 4He targets for experimental studies on nuclear reactions: 6Li + 4He differential cross-section measurement at incident energy of 5.5 MeV

  • Ferrer, F. J.
  • Fernández-Martínez, Begoña
  • Fernández-García, J. P.
  • Barba, F. G.
  • Fernández, Asunción
  • Galaviz, D.
  • Godinho, Vanda
  • Gómez-Camacho, Joaquín
  • Sánchez-Benítez, A. M.
A specially prepared Si/He thin solid film was investigated as a suitable target for experimental studies on nuclear reactions involving 4He targets. For that purpose, the elastically scattered 4He recoil coming from the reaction 6Li + 4He at incident energy of 5.5 MeV was measured. The differential cross section of 6Li on 4He has been found to be fully consistent with previous measurements in the literature. The prospective advantages of using these solid He targets in experiments at radioactive beam facilities are discussed., This work was supported by the Spanish Ministry of Science, Innovation and Universities and co-financed by EU FEDER funds under the following grants: FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, RTI2018-093871-B-I00, PGC2018-096994-B-C22, PGC2018-096994-B-C21 and US-1261006. CSIC support under grant PIE-201760E002 is also acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Preparation of a radiobiology beam line at the 18 MeV proton cyclotron facility at CNA

  • Baratto-Roldan, Anna
  • Jiménez-Ramos, M. C.
  • Jimeno, Sonia
  • Huertas Sánchez, Pablo
  • García López, J.
  • Gallardo, María Isabel
  • Cortés-Giraldo, Miguel Antonio
  • Espino, J. M.
Proton therapy has gained interest in recent years due to its excellent clinical outcomes. However, the lack of accurate biological data, especially in the Bragg peak region of clinical beams, makes it difficult to implement biophysically optimized treatment plans in clinical practice. In this context, low energy proton accelerator facilities provide the perfect environment to collect good radiobiological data, as they can produce high LET beams with narrow energy distributions. This study presents the radiobiology beam line that has been designed at the 18 MeV proton cyclotron facility at the National Centre of Accelerators (CNA, Seville, Spain), to perform irradiations of mono-layer cell cultures. To ensure that all the cells receive the same dose with a suitable dose rate, low beam intensities and broad and homogeneous beam profiles are necessary. To do so, at the CNA an unfocused beam has been used, broadened with a 500 μm thick aluminium scattering foil. Homogeneous dose profiles, with deviations lower than 10% have been obtained over a circular surface of 35 mm diameter for an incident average energy of 12.8 MeV. Further, a Monte Carlo simulation of the beam line has been developed with Geant4, and benchmarked towards experimental measurements, with differences generally below 1%. Once validated, the code has been used, together with an ionization chamber, for dosimetry studies, to characterize the beam and monitor the dose. Finally, cultures of Human Bone Osteosarcoma cells (U2OS) have been successfully irradiated at the radiobiology beam line, investigating the effects of radiation in terms of DNA damage induction., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant No. 675265, OMA–Optimization of Medical Accelerators; from the Spanish Plan for Scientific and Technical Research and Innovation under Grant No. FPA2016-77689-C2-1-R, Grant No. RTI2018-098117-B-C21 and Grant No. SAF2016-74855-P; and from the Council for Innovation, Science and Commerce of the Andalusian Government under Grant No. P12-FQM-1605. CABIMER is supported by the regional Government of Andalucia (Junta de Andalucía)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Determining B(E1) distributions of weakly bound nuclei from breakup cross sections using Continuum Discretized Coupled Channels calculations. Application to 11Be

  • Moro, A.M.
  • Lay, J. A.
  • Gómez-Camacho, Joaquín
A novel method to extract the B(E1) strength of a weakly bound nucleus from experimental Coulomb dissociation data is proposed. The method makes use of continuum discretized coupled channels (CDCC) calculations, in which both nuclear and Coulomb forces are taken into account to all orders. This is a crucial advantage with respect to the standard procedure based on the Equivalent Photon Method (EPM) which does not properly take into account nuclear distortion, higher order coupling effects, or Coulombnuclear interference terms. The systematic and statistical uncertainties of this procedure are evaluated. The procedure is applied to the 11Be nucleus using two sets of available experimental data at different energies, for which seemingly incompatible B(E1) have been reported using the EPM. We show that the present procedure gives consistent B(E1) strengths, thus solving the aforementioned long-standing discrepancy between the two measurements., This work has been partially supported by the Spanish Ministerio de Ciencia, Innovación y Universidades and FEDER funds under projects FIS2017-88410-P and RTI2018-098117-B-C21 and by the European Union's Horizon 2020 research and innovation program under Grant Agreement No. 654002., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Quantification of boron compound concentration for BNCT using positron emission tomography

  • Balcerzyk, Marcin
  • De-Miguel, Manuel
  • Guerrero, C.
  • Fernández-Martínez, Begoña
This article belongs to the Special Issue Biology of Boron Neutron Capture Therapy (BNCT)., [Background]: Boron neutron capture therapy requires a 2 mM 10B concentration in the tumor. The well-known BNCT patient treatment method using boronophenylalanine (BPA) as a boron-carrying agent utilizes [18F]fluoroBPA ([18F]FBPA) as an agent to qualify for treatment. Precisely, [18F]FBPA must have at least a 3:1 tumor to background tissue ratio to qualify the patient for BNCT treatment. Normal, hyperplasia, and cancer thyroids capture iodine and several other large ions, including BF4−, through a sodium-iodine symporter (NIS) expressed on the cell surface in normal conditions. In cancer, NIS is also expressed within the thyroid cell and is not functional., [Methods]: To visualize the thyroids and NIS, we have used a [18F]NaBF4 positron emission tomography (PET) tracer. It was injected into the tail veins of rats. The [18F]NaBF4 PET tracer was produced from NaBF4 by the isotopic exchange of natural 19F with radioactive 18F. Rats were subject to hyperplasia and tumor-inducing treatment. The NIS in thyroids was visualized by immunofluorescence staining. The boron concentration was calculated from Standard Uptake Values (SUV) in the PET/CT images and from the production data. Results: 41 MBq, 0.64 pmol of [18F]NaBF4 PET tracer that contained 0.351 mM, 53 nmol of NaBF4 was injected into the tail vein. After 17 min, the peak activity in the thyroid reached 2.3 MBq/mL (9 SUVmax). The natB concentration in the thyroid with hyperplasia reached 381 nM., [Conclusions]: Such an incorporation would require an additional 110 mg/kg dose of [10B]NaBF4 to reach the necessary 2 mM 10B concentration in the tumor. For future BNCT treatments of thyroid cancer, contrary to the 131I used now, there is no post-treatment radioactive decay, the patient can be immediately discharged from hospital, and there is no six-month moratorium for pregnancy. This method can be used for BNCT treatment compounds of the type R-BFn, where 1 <= n <= 3, labeled with 18F relatively easily, as in our example. A patient may undergo injection of a mixture of nonradioactive R-BFn to reach the necessary 10B concentration for BNCT treatment in the tumor together, with [18F]R-BFn for boron mapping., This project was partially funded by the Spanish RTI2018-098117-B-C21 project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

New data for the definition of neutron beams for Boron Neutron capture therapy

  • Macías-Montero, M.
  • Fernández-Martínez, Begoña
  • Praena, Javier
Boron Neutron Capture Therapy (BNCT) is neutron radiotherapy used to treat tumours cells previously doped with Boron-10. This therapy requires an epithermal neutron beam for the treatment of deep tumours and a thermal beam for shallow ones. Thanks to recent high-current commercial accelerators, Accelerator-Based Neutron Sources (ABNS) are a competitive option for providing therapeutic neutron beams in hospitals. In this work, the neutron field generated by the Li (p,n)Be reaction at 1950 keV is studied as a neutron source in ABNS, being measured by the Time-Of-Flight (TOF) technique at HiSPANoS facility (Spain). Moreover, two Beam Shaping Assemblies (BSA) for deep and shallow tumour treatment, which are specially designed for the 1950 keV neutron field, are evaluated for BNCT via Monte Carlo simulations (MCNP). Results in agreement with the International Atomic Energy Agency (IAEA) figures of merit endorse the use of this neutron field for BNCT., The authors thank CNA technicians for their help during the experiment. We acknowledge the financial support for this work from the Spanish MINECO and FEDER funds under contract FIS 2015-69941-C2-1-P, FPA 2016-77689-C2-1-R, A-FQM-371-UGR18 (Programa Operativo FEDER Andalucıa 2014–2020), Asociación Española Contra el Cáncer (AECC) under contract PS16163811PORR, Junta de Andalucía under contract P11-FQM-8229, the founders of the University of Granada Chair Neutrons for Medicine: Spanish Fundación ACS and Capitán Antonio, US-1261006 (Proyectos I + D + i FEDER Andalucía 2014–2020), and RTI 2018-098117-B-C21 (MINECO). M. Macías acknowledges the FPI fellowship BES-2014-068808 granted in the project FPA 2013-47327-C2-1-R.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Research facilities and highlights at the Centro Nacional de Aceleradores (CNA)

  • Gómez-Camacho, Joaquín
  • García López, J.
  • López-Gutiérrez, J. M.
  • García-Tenorio, R.
  • Santos, F. J.
  • Chamizo, Elena
  • Ferrer, F. J.
  • Jiménez-Ramos, M. C.
  • Balcerzyk, Marcin
  • Fernández-Martínez, Begoña
Part of a collection: Focus Point on Small and Medium and Particle Accelerator Facilities in Europe, The Centro Nacional de Aceleradores is a user-oriented accelerator facility in Seville, Spain. Its main facilities are a 3 MV tandem accelerator, an 18 MeV proton Cyclotron, a tandetron used for AMS, a compact accelerator used for radiocarbon measurements, a Co irradiator and a PET/CT scanner. The technical specifications and research applications of these facilities are described. A neutron beam line associated to a charged pulsed beam in the tandem allows for time of flight measurements which determine the neutron energy. The use of an adequate stripper gas in the AMS tandetron permits to measure heavy radionuclides with very low detection levels, allowing to perform environmental studies using these radionuclides as tracers. The use of the microbeam in the tandem accelerator allows to apply the ion beam-induced current technique to investigate the spectroscopic properties and radiation hardness of different semiconductor detectors., Also the funding made available for infrastructures through the ICTS program of the Spanish ministry of science, making use of FEDER funds from the European Union. The continuous support of CNA patrons, the University of Seville, the Junta de Andalucía and CSIC is acknowledged. Private funds, through contracts with companies and institutions, such as Curium, Alter technologies, and the andalusian health service (SAS), made possible to maintain contracts of key personnel. We acknowledge the funding of projects by the European Union, H2020-847594, H2020-654002, H2020-847552, H2020-847594 , by the Spanish ministry of science RTI2018-098117-B-C21, RTC-2017-6369-3, EQC2018-004193-P, EQC2018-004095-P, EQC2018-004166-P, PGC2018-094546-B-I00, and by the Junta de Andalucía FEDER progrem US-1261006, US-1263369, P18-RT-1900.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The Hussein–McVoy formula for inclusive breakup revisited, A Tribute to Mahir Hussein

  • Gómez-Ramos, M.
  • Gómez-Camacho, Joaquín
  • Lei, J.
  • Moro, A.M.
Part of a collection: cluster Structure and Dynamics of Nuclei - A tribute to Mahir Hussein, In 1985, Hussein and McVoy [Nuc. Phys. A445 (1985) 124] elucidated a formula for the evaluation of the nonelastic breakup (“stripping”) contribution in inclusive breakup reactions. The formula, based on the spectator core model, acquires a particularly simple and appealing form in the eikonal limit, to the extent that it has become the standard procedure to analyze single-nucleon knockout reactions at intermediate energies. In this contribution, a critical assessment of this formula is presented and its connection with other, noneikonal expressions discussed. Some calculations comparing the different formulae are also presented for the one-nucleon removal of O+Be reaction at several incident energies., This work has been partially supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under projects FIS2017-88410-P and RTI2018-098117-B-C21 and by the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 654002. J.L. acknowledges support from the National Natural Science Foundation of China (Grants No. 12035011, No. 11975167, and No. 11535004), by the National Key R&D Program of China (Contracts No. 2018YFA0404403 and 2016YFE0129300), and by the Fundamental Research Funds for the Central Universities (Grant No. 22120200101). M. G.-R. acknowledges support from the Alexander von Humboldt foundation.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Experimental study of the nature of the and excited states in using the reaction in inverse kinematics

  • Kuhn, K.
  • Sarazin, F.
  • Nunes, F. M.
  • Álvarez, M. A. G.
  • Andreoiu, C.
  • Bardayan, D. W.
  • Bender, P. C.
  • Blackmon, J. C.
  • García Borge, María José
  • Braid, R.
  • Brown, B. A.
  • Catford, W. N.
  • Diget, C. Aa.
  • Di Pietro, A.
  • Drake, T. E.
  • Figuera, P.
  • Garnsworthy, A.B.
  • Gómez-Camacho, Joaquín
  • Hackman, G.
  • Hager, U.
  • Ilyushkin, S. V.
  • Nácher, Enrique
  • O'Malley, P. D.
  • Perea, Ángel
  • Pesudo, V.
  • Pittman, S. T.
  • Smalley, D.
  • Svensson, C. E.
  • Tengblad, Olof
  • Thompson, P.
  • Unsworth, C.
  • Wang, Z. M.
10 pags., 8 figs., 4 tabs., The nature of the and excited states in is studied using the transfer reaction in inverse kinematics at 10A MeV at TRIUMF ISAC-II, in particular to assess whether either of them can be considered as an excited halo state. The angular distributions for both states are extracted using deuteron- coincidences and analyzed using a transfer model taking into account one-step and two-step processes. A good fit of the angular distributions is obtained considering only the one-step process, whereby an inner neutron of is removed, leaving the halo neutron intact. Higher-order processes however cannot be rejected. The small spectroscopic factors extracted suggest that the structure of both states is not uniquely halo-like, but rather display a more complex configuration mixing cluster and halo structures. Further insights are limited, as this experiment specifically probed the halo-like (but not cluster-like) configuration in both states., This work was partially supported by the U.S. Department of Energy (DOE) through Grants/Contracts No. DE-FG03-93ER40789 (Colorado School of Mines), No. DEFG02-96ER40978 (Louisiana State), No. DE-SC0021422 (Michigan State), No. DE-AC05-00OR22725 (Oak Ridge National Laboratory), the National Nuclear Security Administration (NNSA) under the Stewardship Science Academic Alliances program through U.S. DOE Cooperative Agreements No. DE-FG52-08NA28552, and the National Science Foundation under Grant No. PHY-1811815 (Michigan State). This work is also supported by the Natural Sciences and Engineering Research Council of Canada (NSERC), the Canadian Foundation for Innovation (CFI), the British Columbia Knowledge and Development Fund (BCKDF), the Italian National Institute for Nuclear Physics (INFN), the Spanish Ministry of Science and Innovation and FEDER funds under Projects RTI2018-098117-B-C21 and PGC2018-096994-BC21, and the Spanish Agency of Research (AEI) via Project No. PID2019-104714GB-C21., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Thin film nanostructuring at oblique angles by substrate patterning

  • Muñoz-Piña, Sandra
  • Alcaide, Antonio M.
  • Limones-Ahijón, Blanca
  • Oliva-Ramírez, Manuel
  • Rico, Víctor J.
  • Alcalá, Germán
  • González Sagardoy, María Ujué
  • García-Martín, José Miguel
  • Álvarez, Rafael
  • Wang, Dong
  • Schaaf, Peter
  • González-Elipe, Agustín R.
  • Palmero, Alberto
It is demonstrated that, besides classical nanocolumnar arrays, the oblique angle geometry induces the growth of singular structures in the nanoscale when using wisely designed patterned substrates. Well-ordered array of crosses, cylindrical nanorods or hole structures arranged in square or hexagonal regular geometries are reported as examples, among others. The fundamental framework connecting substrate topography and film growth at oblique angles is presented, allowing the use of substrate patterning as a feasible thin film nanostructuring technique. A systematic analysis of the growth of TiO2 thin films on 4 different lithographic patterned substrates in 4 different scale lengths is also presented. A first conclusion is the existence of a height-based selective growth in the initial stages of the deposition, by which the film preferentially develops on top of the tallest substrate features. This behavior is maintained until the film reaches a critical thickness, the so-called Oblivion Thickness, above which the film topography becomes gradually independent of the substrate features. A general formula relating the spatial features of the pattern, the coarsening exponent and the Oblivion Thickness has been deduced., The authors thank the financial support from MCIN/AEI/10.13039/ 501100011033 projects PID2019-110430GB-C21, PID2020-112620GBI00, PID2020-114270RA-I00 and RTI2018-098117-B-C21 (also financed by FEDER Una manera de hacer europa), the Junta de Andalucía (PAIDI- 2020 through projects P18-RT-3480 and P18-RT-6079, and through its 2019 PhD Researcher Hiring Program), the CSIC (2019AEP161 and 201860E050), the Regional Government of Madrid (project IND2017/ IND-7668 and YEI contract PEJ-2019-AI/IND-14451 with support from FSE), the H2020-EU.1.2.1-FET OPEN program (grant 899352, project SOUNDofICE, and the EFRE Infra-Pro project ChAMP), and the University of Seville (VI PPIT-US). The work is supported by the Deutsche Forschungsgemeinschaft (DFG, grant Scha 632/24, “Tailored Disorder” and Scha 632/27, “DFGGer ¨atezentrum”). This work is also supported by the free state of Thuringia under grants 2015 FGI 0025 305 (FastμXRD) and B715-10009 (BioMacroNano2020), all co-financed by the European Union within the framework of the European Regional Development Fund (ERDF). The service from the MiNa Laboratory at IMN-CNM (CSIC), funded from CM (project S2018/NMT-4291 TEC2SPACE), MINECO (project CSIC13-4E- 1794) and EU (FEDER, FSE), is also acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Compositional gradients at the nanoscale in substoichiometric thin films deposited by magnetron sputtering at oblique angles: A case study on SiOx thin films

  • García-Valenzuela, Aurelio
  • Alcaide, Antonio M.
  • Rico, Víctor J.
  • Ferrer, F. J.
  • Alcalá, Germán
  • Rojas, T. Cristina
  • Álvarez, Rafael
  • González-Elipe, Agustín R.
  • Palmero, Alberto
We demonstrate the existence of stoichiometric variations at the nanoscale when growing nanocolumnar SiO thin films by reactive magnetron sputtering deposition at oblique angles. Results show stoichiometric variations in the range 0.3 < x < 1.3 when growing a SiO thin film. This agrees with results from a numerical growth model that obtains a shift of the stoichiometry in all nanocolumns from lower values at the side facing the Si target to higher values at the opposite side. The different momentum distribution of the gaseous reactive and sputtered species results in preferential incorporation of the latter at a particular side of the nanocolumns. The general occurrence of this mechanism during the reactive magnetron sputtering deposition of substoichiometric thin films at oblique angles is discussed., The authors thank the FEDER program through AEI-MICINN (PID2019-110430GB-C21) and the Junta de Andalucía (PAIDI-2020 through projects P18-RT-3480 and P18-RT-6079), the CSIC (2019AEP161 and 201860E050), the Regional Government of Madrid (project IND2017/IND-7668), the Spanish Ministry of Science and Innovation (PID2020-112620GB-I00, RTI2018-098117-B-C21, and PID2020-114270RA-I00), the H2020-EU.1.2.1-FET OPEN program (grant 899352, project SOUNDofICE, and the EFRE Infra-Pro project ChAMP), and the University of Seville (V and VI PPIT-US) for financial support. We also acknowledge the Centro Nacional de Aceleradores (CNA) for its support., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Production yields at the distal fall-off of the β+ emitters 11C and 13N for in-vivo range verification in proton therapy

  • Rodríguez González, M. Teresa
  • Guerrero, C.
  • Jiménez-Ramos, M. C.
  • Lerendegui-Marco, J.
  • Millán Callado, María de los Ángeles
  • Parrado-Gallego, Ángel
  • Gómez-Camacho, Joaquín
  • Quesada, José Manuel
In proton therapy, Positron Emission Tomography (PET) range verification relies on the comparison of the measured and estimated activity distributions from β emitters produced by the proton beam in the patient. The accuracy of the estimated activity distributions is basically that of the underlying reaction cross section data. In this context, we have developed a new method for measuring β production yields combining the multi-foil technique with a clinical PET scanner, resulting in energy differential cross sections from a single irradiation. The method has been applied to the production of C11 (t = 20.36 min) and Ny13 (t = 9.97 min), the main candidates for off-line PET range verification, in carbon, nitrogen and oxygen, the main elements of the human body. The energy range studied with the 18 MeV CNA cyclotron corresponds to the distal fall-off of the activity curve, i.e. near the Bragg peak., This project has received funding from the Spanish Ministry of Economy and Competitiveness projects RYC-2014-15271, FPA2016-77689-C2-1-R and RTI2018-098117-B-C21, from the European H2020-847552 (SANDA) and the V Plan Propio de Investigación Programme from the University of Sevilla. T. Rodriguez-Gonzalez acknowledges the Spanish FPI predoctoral grant.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Study of ionization charge density-induced gain suppression in LGADs

  • Jiménez-Ramos, M. C.
  • García López, J.
  • García-Osuna, Adrián
  • Vila, Iván
  • Currás, Esteban
  • Jaramillo, R.
  • Hidalgo, Salvador
  • Pellegrini, Giulio
This article belongs to the Section Physical Sensors., Gain suppression induced by excess carriers in Low Gain Avalanche Detectors (LGADs) has been investigated using 3 MeV protons in a nuclear microprobe. In order to modify the ionization density inside the detector, Ion Beam Induced Current (IBIC) measurements were performed at different proton beam incidence angles between 0° and 85°. The experimental results have been analyzed as a function of the ionization density projected on the multiplication layer, finding that the increase of ionization density leads to greater gain suppression. For bias voltages close to the gain onset value, this decrease in gain results into a significant distortion of the transient current waveforms measured by the Time-Resolved IBIC (TRIBIC) technique due to a deficit in the secondary holes component. For angles of incidence such that the Bragg peak falls within the sensitive volume of the detector, the formation of microplasmas modifies the behavior of the gain curves, producing an abrupt decrease in gain as the angle increases., This research was funded by the Spanish Ministry of Science, Innovation and Universities grant numbers RTI2018-098117-B-C21 and MCIN/AEI/10.13039/501100011033, the Spanish Ministry of Science, Innovation and Universities/FEDER funds grant numbers ICTS-2020-02-US-4, the Regional Ministry of Economy, Knowledge, Business and University grant number US-1380791 and the European Union’s ERDF program “A Way of making Europe” grant numbers FPA2017-85155-C4-1-R, FPA2017-85155-C4-2-R., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification

  • Balibrea, Javier
  • Lerendegui-Marco, J.
  • Ladarescu, I.
  • Guerrero, C.
  • Rodríguez González, M. Teresa
  • Jiménez-Ramos, M. C.
  • Fernández-Martínez, Begoña
  • Domingo Pardo, César
We report on a hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA cyclotron facility using a set of two synchronous Compton imagers and different target materials. The time structure of the 18 MeV proton beam was shaped with a series of beam-on and beam-off intervals, thereby mimicking a pulsed proton beam on a long time scale. During beam-on intervals, Compton imaging was performed utilizing the high energy γ-rays promptly emitted from the nuclear reactions occurring in the targets. In the course of the beam-off intervals in situ positron-emission tomography was accomplished with the same imagers using the β decay of activated nuclei. The targets used were stacks of different materials covering also various proton ranges and energies. A systematic study on the performance of these two complementary imaging techniques is reported and the experimental results interpreted on the basis of Monte Carlo calculations. The results demonstrate the possibility to combine both imaging techniques in a concomitant way, where high-efficiency prompt-gamma imaging is complemented with the high spatial accuracy of PET. Empowered by these results we suggest that a pulsed beam with a suitable duty cycle, in conjunction with in situ Compton- and PET-imaging may help to attain complementary information and quasi real-time range monitoring with high accuracy., Open Access funding provided thanks to the CRUE-CSIC agreement with springer nature. This work has been carried out in the framework of a project funded by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC Consolidator Grant project HYMNS, with grant agreement No.~681740). The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PID2019-104714GB-C21, FPA2017-83946-C2-1-P, FIS2015-71688-ERC, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, CSIC for funding PIE-201750I26 and from the European H2020-847552 (SANDA). This work was partially supported by Generalitat Valenciana PROMETEO/2019/007. J. Balibrea-Correa is supported by grant ICJ220-045122-I funded by MCIN/AEI/10.13039/501100011033 and by European Union NextGenerationEU/PRTR. J. Lerendegui-Marco is supported by grant FJC2020-044688-I funded by MCIN/AEI/10.13039/501100011033 and by European UnionNextGenerationEU/PRTR.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Production of 11C, 13N and 15O in proton-induced nuclear reactions up to 200 MeV

  • Rodríguez González, M. Teresa
  • Guerrero, C.
  • Bäcker, C. M.
  • Bauer, J.
  • Bäumer, C.
  • Brons, S.
  • Jentzen, W.
  • Jiménez-Ramos, M. C.
  • Millán Callado, María de los Ángeles
  • Schömers, C.
  • Timmermann, B.
  • Quesada, José Manuel
  • Capote-Noy, Roberto
Production cross sections of light positron emitters 11C (t1/2=20.36 min), 13N (t1/2=9.97 min) and 15O (t1/2=122 s) have been measured for proton-induced reactions on the main relevant constituents of the human body (C, N and O) from threshold up to 200 MeV of proton incident energy. This has been accomplished by means of two complementary experiments at the clinical proton treatment centers WPE (Essen) and HIT (Heidelberg), both in Germany. In the first case, the multi-foil activation technique was combined with PET imaging, a methodology previously developed at CNA (Seville, Spain). In the second experiment, aimed at energies below 50 MeV, the activation of single foils was measured with conventional LaBr3 detectors. In both cases the IAEA monitor reaction natCu(p,x)63Zn data was used for validation purposes. The most complete and accurate set of excitation functions for the production of light-positron emitters 11C, 13N and 15O in proton induced reactions on human tissue up to 200 MeV is presented. These data are needed for nuclear reaction model development and are extremely important to improve the accuracy of the PET range verification in proton radiotherapy. Seven excitation functions have been measured: 12C(p,x)11C, 14N(p,x)11C, 14N(p,x)13N, 14N(p,γ)15O, 16O(p,x)11C, 16O(p,x)13N and 16O(p,x)15O up to 200 MeV of proton incident energy., The research work presented herein has received funding from the Spanish Ministry of Economy and Competitiveness projects under grants no RYC-2014-15271, FPA2016-77689-C2-1-R and RTI2018-098117-B-C21, from the EC project H2020-847552 (SANDA), from the “Consejería de Economía y Conocimiento de la Junta de Andalucía” project under grant no. P18-RT-1900, from the Regional Ministry of Economy, Knowledge, Business and University/FEDER funds under grant no. US-1380791 and from the “V Plan Propio de Investigación (V PPIT-US)” programme from the University of Sevilla. M.C. Jiménez Ramos acknowledges the support to this work through a VI PPIT-US contract. J. Bauer acknowledges funding from the Universtity of Heidelberg as Olympia-Morata fellow. T. Rodriguez-Gonzalez acknowledges the Spanish FPI PhD grant associated to the project FPA2016-77689-C2-1-R., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Continuous and pulsed fast neutron beams at the CNA HiSPANoS facility

  • Millán Callado, María de los Ángeles
  • Guerrero, C.
  • Fernández-Martínez, Begoña
  • Gómez-Camacho, Joaquín
  • Macías Martínez, Miguel Ángel
  • Quesada, José Manuel
© 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)., The characteristics of the fast neutron beams produced in the HiSPANoS facility at Centro Nacional de Aceleradores (CNA) are presented. The neutrons are generated by deuteron beams from a 3 MV tandem accelerator in either continuous (5 μA) or pulsed (2 ns width, 500 kHz and 4% duty cycle) mode. In this work, the pulsed mode was used in a time-of-flight characterization of the produced neutron beams in terms of yield, flux, energy resolution, and background. The results were then validated through their comparison with previously published data. Quasi-monoenergetic neutron beams between 2 and 6 MeV are produced by means of the H(d,n)He reaction, featuring a neutron yield of 10 n/sr/μC at the target, with an energy resolution of about 7% at 150 cm. Neutron beams with broad energy distributions are produced by deuteron irradiation of thick beryllium and lithium targets, resulting in maximum neutron energies of 10 and 20 MeV, respectively. In this case, the neutron yields are significantly higher, reaching 10 n/sr/μC. On the basis of these results, we consider that the HiSPANoS facility is now fully operational for the usage of fast neutrons by internal and external users of CNA., This work has received funding from the Euratom research and training program 2014–2018 under the grant agreement No 847594 (H2020-Euratom-ARIEL), the Marie Curie actions of the 7th Framework Program under the grant agreement No 334315 (FP7-PEOPLE-NeutANdalus), the Spanish national projects FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, and PID2021-123879OB-C21; and the FEDER Andalucía funds under the project US-1261006., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Low temperature nucleation of thermochromic VO2 crystal domains in nanocolumnar porous thin films

  • Alcaide, A M
  • Regodón, Guillermo
  • Ferrer, F J
  • Rico, Víctor J.
  • Álvarez, Rafael
  • Rojas, T. Cristina
  • González-Elipe, Agustín R.
  • Palmero, Alberto
The low temperature formation of monoclinic VO2crystal domains in nanocolumnar vanadium/oxygen thin films prepared by magnetron sputtering at oblique angles is analyzed. The synthesis procedure involved the deposition of amorphous nanocolumnar VO1.9thin films at room temperature and its subsequent annealing at temperatures between 250 °C and 330 °C in an oxygen atmosphere. The thermochromic transition of these films was found at a temperature of 47 °C when the annealing temperature was 270 °C and 58 °C when the annealing temperature was 280 °C and 290 °C, presenting a clear drop of the optical transmittance in the infrared region of the spectrum. The significant downshift in the temperature window to obtain VO2in comparison with compact films and other strategies in literature is explained by the particular morphology of the nanocolumnar structures, which contains numerous defects along with open and embedded porosity., The authors thank the financial support from MCIN/AEI/10.13039/501100011033 projects PID2019-110430GB-C21, PID2020-112620GB-I00, PID2020-114270RA-I00 and RTI2018-098117-B-C21 (also financed by FEDER Una manera de hacer europa'), the Junta de Andalucia (PAIDI-2020 through project P18-RT-3480), the H2020-EU.1.2.1-FET OPEN program (Grant 899352, project SOUNDofICE, and the EFRE Infra-Pro project ChAMP), and the University of Seville (VI PPIT-US). Guillermo Regodon would like to acknowledge funding from the European Comission-NextGenerationEU through the 'Plan de Recuperacion, Transformacion y Resiliencia' from the Spanish Government. The authors also thank Daniel Fernandez de los Reyes for the HAADF-STEM and EELS measurements, funded by Grant UCA/R155REC/2021, that were carried out at the DME-SC-ICyT-ELECMI-UCA., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

  • Domingo Pardo, César
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Caballero Ontanaya, Luis
  • Ladarescu, I.
  • Lerendegui-Marco, J.
  • Tain, José Luis
  • Tarifeño-Saldivia, A.
  • n_TOF Collaboration
This article presents a few selected developments and future ideas related to the measurement of (n, γ) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with γ-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Production of carbon‑11 for PET preclinical imaging using a high‑repetition rate laser‑driven proton source

  • Peñas, Juan
  • Alejo, Aarón
  • Bembibre, Adrián
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, C.
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán Callado, María de los Ángeles
  • Puyuelo-Valdés, Pilar
  • Seimetz, Michael
  • Benlliure, José
Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the first time the use of a high-repetition rate, ultra-intense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10-14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11 B(p,n) 11 C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Significant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-the-art technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the María de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovación y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by ‘la Caixa’ Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by ‘European Union NextGenerationEU., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Neutron activation as benchmark for cross section evaluations: Demonstration through the MACS of 50Cr for nuclear technology applications

  • Pérez-Maroto, Pablo
  • Guerrero, C.
  • Fernández-Martínez, Begoña
  • Casanovas-Hoste, A.
  • Stamati, M. E.
Neutron cross section libraries often differ with each other due to the limited availability of differential cross section data from time-of-flight experiments. These are indeed challenging, requiring state-of-the-art facilities and detectors, as well as an involved data analysis. However, in some cases, an easier alternative can be found in simpler integral experiments, as it is demonstrated herein. The capture cross section of 50Cr plays an important role in nuclear reactors and recent criticality safety benchmarks pointed to an increase of 20%, which has been incorporated in the recent INDEN (2023) evaluated library. In this work we have carried out an epithermal neutron activation measurement on 50Cr at the CNA HiSPANoS facility. The resulting Maxwellian Average Cross Section (MACS) at 30 keV, 37.1(20) mb, provides enough evidence to discard the proposed increase in the cross section. Furthermore, it illustrates the suitability of the activation technique to benchmark cross section evaluations in the epithermal energy region. This can in principle be extended to other reactions (as far as they result in radioactive nuclei) and to the fast neutron range by employing mono-energetic beams from D-D and D-T reactions in similarly simple experiments., This measurement has received funding from the Euratom Research and Training Programme 2014-2018 under grant agreement No 847594 (ARIEL), and from the Spanish national projects RTI2018-098117-B-C21 and PID2021-123879OB-C21. From the UPC side, we would like to acknowledge also Spanish projects PID2019-104714GB-C21 and PID2022-138297NB-C21. The work presented herein is part of the PhD thesis of P. Pérez-Maroto at Universidad de Sevilla, Spain, funded through the FPI national Grant No PRE2019-089678., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Algebraic DVR approaches applied to describe the stark effect

  • Bermúdez-Montaña, M.
  • Rodríguez-Arcos, M.
  • Lemus, R.
  • Arias, J.M.
  • Gómez-Camacho, Joaquín
  • Orgaz, E.
Two algebraic approaches based on a discrete variable representation are introduced and applied to describe the Stark effect in the non-relativistic Hydrogen atom. One approach consists of considering an algebraic representation of a cutoff 3D harmonic oscillator where the matrix representation of the operators 𝑟2 and 𝑝2 are diagonalized to define useful bases to obtain the matrix representation of the Hamiltonian in a simple form in terms of diagonal matrices. The second approach is based on the 𝑈(4) dynamical algebra which consists of the addition of a scalar boson to the 3D harmonic oscillator space keeping constant the total number of bosons. This allows the kets associated with the different subgroup chains to be linked to energy, coordinate and momentum representations, whose involved branching rules define the discrete variable representation. Both methods, although originating from the harmonic oscillator basis, provide different convergence tests due to the fact that the associated discrete bases turn out to be different. These approaches provide powerful tools to obtain the matrix representation of 3D general Hamiltonians in a simple form. In particular, the Hydrogen atom interacting with a static electric field is described. To accomplish this task, the diagonalization of the exact matrix representation of the Hamiltonian is carried out. Particular attention is paid to the subspaces associated with the quantum numbers 𝑛=2,3 with 𝑚=0., This research received no external funding. This work is partially supported by DGAPA-UNAM, Mexico, under project IN-212020, by the Consejería de Economía, Conocimiento, Empresas y Universidad de la Junta de Andalucía (Spain) under Group FQM-160, by the Spanish Ministerio de Ciencia e Innovaciíon, ref. FIS2017-88410-P, RTI2018-098117-B-C21 and PID2019-104002GB-C22, and by the European Commission, ref. H2020-INFRAIA-2014-2015 (ENSAR2). First author is grateful to DGAPA-UNAM for the postdoctoral scholarship (Facultad de Química). Second author is also grateful for the scholarship (Posgrado en Ciencia e Ingeniería de Materiales) provided by CONACyT, México., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Measurement of the 33S(n,α)30Si Thermal Cross-Section with Slow Neutrons at ILL

  • Praena, Javier
  • Fernández-Martínez, Begoña
  • Macías, Miguel
  • Porras, Ignacio
  • Pedrosa-Rivera, María
  • Koivunoro, Hanna
  • Sabaté-Gilarte, Marta
  • Arias de Saavedra, Fernando
This article belongs to the Special Issue Quantum Beam Science: Feature Papers 2025, This work is focused on an accurate experimental determination of the thermal 33S(n,α) 30Si cross-section. This cross-section is a critical parameter for the potential use of 33S as a cooperative target in boron neutron capture therapy or to understand its role in the stellar nucleosynthesis of 36S. At present, there are large discrepancies in this experimental value; therefore, in this work we measured it relative to the 10B(n,α) 7Li standard cross-section at the high flux reactor of the Institut Laue-Langevin. The experimental setup was based on a double-sided silicon strip detector. Two 33S samples were used. One 10B sample was used as reference. Particular attention was taken to the characterization of the mass thickness of the samples before and after the experiment because of the high volatility of 33S. Such work was already published in a dedicated paper. A cross-check of the 10B sample was carried out with the neutron flux monitor at the n_TOF-CERN facility. The obtained cross-section of (280 ± 33) mb is significantly higher than the existing data., This work was carried out within the framework of Project No. PID2020.117969RB. i00 funded by MICIU/AEI/10.13039/5011000110 33, RTI2018-098117-B-C21 (AEI-MICIN), Spanish Association Against Cancer (AECC) (Grant PS16163811PORR), Junta de Andalucía P11-FQM-8229 and the sponsors of the University of Granada Chair Neutrons for Medicine (Fundación ACS, Capitán Antonio and La Kuadrilla) and the funding agencies of the participating institutes., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Microdosimetry performance of the first multi-arrays of 3D-cylindrical microdetectors

  • Bachiller-Perea, Diana
  • Zhang, Mingming
  • Fleta, Celeste
  • Quirion, David
  • Bassignana, Daniela
  • Gómez, Faustino
  • Guardiola Salmerón, Consuelo
The present work reports on the microdosimetry measurements performed with the two first multi-arrays of microdosimeters with the highest radiation sensitive surface covered so far. The sensors are based on new silicon-based radiation detectors with a novel 3D cylindrical architecture. Each system consists of arrays of independent microdetectors covering 2 mm× 2 mm and 0.4 mm× 12 cm radiation sensitive areas, the sensor distributions are arranged in layouts of 11× 11 microdetectors and 3× 3 multi-arrays, respectively. We have performed proton irradiations at several energies to compare the microdosimetry performance of the two systems, which have different spatial resolution and detection surface. The unitcell of both arrays is a 3D cylindrical diode with a 25 μm diameter and a 20 μm depth that results in a welldefined and isolated radiation sensitive micro-volume etched inside a silicon wafer. Measurements were carried out at the Accélérateur Linéaire et Tandem à Orsay (ALTO) facility by irradiating the two detection systems with monoenergetic proton beams from 6 to 20 MeV at clinical-equivalent fluence rates. The microdosimetry quantities were obtained with a spatial resolution of 200 μm and 600 μm for the 11× 11 system and for the 3× 3 multi-array system, respectively. Experimental results were compared with Monte Carlo simulations and an overall good agreement was found. The good performance of both microdetector arrays demonstrates that this architecture and both configurations can be used clinically as microdosimeters for measuring the lineal energy distributions and, thus, for RBE optimization of hadron therapy treatments. Likewise, the results have shown that the devices can be also employed as a multipurpose device for beam monitoring in particle accelerators., he 3D-cylindrical microdetectors fabrication was funded from the H2020 project AIDA-2020, GA no. 654168 (second run) and from the European Union’s Horizon research and innovation program under the Marie Skłodowska-Curie grant agreement No 745109 (third run). This work made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. D. Bachiller-Perea and C. Guardiola thanks the funding from the CNRS-Momentum fellow and the staff of the ALTO facility for their help to perform the calibration tests. C. Guardiola gratefully acknowledges the support from the CNRS/IN2P3 Computing Center (Lyon, France) for providing the computing and data-processing resources needed for this work. Authors thank C. Lacasta and G. Llosá for their advices for addressing issues related to the readout electronics., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

New measurement of 50Cr and 53Cr (n,γ) cross sections at n_TOF: a call for chromium nuclear data revision

  • Pérez-Maroto, Pablo
  • Guerrero, C.
  • Casanovas, A.
  • Fernández, B.
  • Mendoza, E.
  • Alcayne, V.
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Quesada, J. M.
  • Capote, R.
  • Aberle, O.
  • Altieri, S.
  • Amaducci, S.
  • Andrzejewski, J.
  • Babiano-Suarez, V.
  • Bacak, M.
  • Balibrea-Correa, J.
  • Beltrami, C.
  • Bennett, S.
  • Bernardes, A. P.
  • Berthoumieux, E.
  • Beyer, R.
  • Boromiza, M.
  • Bosnar, D.
  • Caamaño, M.
  • Calviño, F.
  • Calviani, M.
  • Cano-Ott, D.
  • Castelluccio, D. M.
  • Cerutti, G.
  • Chasapoglou, S.
  • Chiaveri, E.
  • Colombetti, P.
  • Colonna, N.
  • Console Camprini, P.
  • Cortés, G.
  • Cortés-Giraldo, M. A.
  • Cosentino, L.
  • Cristallo, S.
  • Dellmann, S. F.
  • Diakaki, M.
  • Di Castro, M.
  • Dietz, M,
  • Di Maria, S.
  • Dressler, R.
  • Dupont, E.
  • Durán, I.
  • Eleme, Z.
  • Fargier, S.
  • Fernández-Domínguez, B.
  • Finocchiaro, P.
  • Fiore, S.
  • Furman, V.
  • García-Infantes, F.
  • Gawlik-Ramiega, A.
  • Gervino, G.
  • Gilardoni, S.
  • González-Romero, E.
  • Gunsing, F.
  • Gustavino, C.
  • Heyse, J.
  • Hillman, W.
  • Jenkins, D. G.
  • Jericha, E.
  • Junghans, A.
  • Kadi, Y.
  • Kaperoni, K.
  • Kaur, G.
  • Kimura, A.
  • Knapová, I.
  • Kokkoris, M.
  • Kopatch, Y.
  • Krtička, M.
  • Kyritsis, N.
  • Ladarescu, I.
  • Lederer-Woods, C.
  • Lerner, G.
  • Manna, A.
  • Martínez, T.
  • Masi, A.
  • Massimi, C.
  • Mastinu, P.
  • Mastromarco, M.
  • Maugeri, E. A.
  • Mazzone, A.
  • Mengoni, A.
  • Michalopoulou, V.
  • Milazzo, P. M.
  • Mucciola, R.
  • Murtas, F.
  • Musacchio González, E.
  • Musumarra, A.
  • Negret, A.
  • Patronis, N.
  • Pavón, J. A.
  • Pellegriti, M. G.
  • Pérez de Rada Fiol, A.
  • Perkowski, J.
  • Petrone, C.
  • Pirovano, E.
  • Plaza del Olmo, J.
  • Pomp, S.
  • Porras, I.
  • Praena, J.
  • Reifarth, R.
  • Rochman, D.
  • Romanets, Y.
  • Rubbia, C.
  • Sánchez-Caballero, A.
  • Sabaté-Gilarte, M.
  • Schillebeeckx, P.
  • Schumann, D.
  • Sekhar, A.
  • Smith, A. G.
  • Sosnin, N. V.
  • Stamati, M. E.
  • Sturniolo, A.
  • Tagliente, G.
  • Tarifeño-Saldivia, A.
  • Tarrío, D.
  • Torres-Sánchez, P.
  • Urlass, S.
  • Vagena, E.
  • Valenta, S.
  • Variale, V.
  • Vaz, P.
  • Vecchio, G.
  • Vescovi, D.
  • Vlachoudis, V.
  • Vlastou, R.
  • Wallner, A.
  • Woods, P. J.
  • Wright, T.
  • Zarrella, R.
  • Žugec, P.
50Cr and 53Cr are very relevant in criticality safety benchmarks related to nuclear reactors. The discrepancies of up to 30% between the neutron capture cross section evaluations have an important effect on the kef f and k∞ in criticality benchmarks particularly sensitive to chromium. In this work, the 50,53Cr(n,γ ) cross sections are to be determined between 1 and 100 keV with an 8–10% accuracy following the requirements of the NEA High Priority Request List (HPRL) to solve the current discrepancies. We have measured these reactions by the time-of-flight technique at the EAR1 experimental area of the n_TOF facility, using an array of four C6D6 detectors with very low neutron sensitivity. The highly-enriched samples used are significantly thinner than in previous measurements, thus minimizing the multiple-scattering effects. We have produced, and analysed with the R-matrix analysis code SAMMY, capture yields featuring 33 resonances of 50Cr and 51 of 53Cr with an accuracy between 5% and 9%, hence fulfilling the requirements made by the NEA. The differential and integral cross sections have been compared to previous data and evaluations. The new measured 50,53Cr(n,γ ) cross sections provide a valuable input for upcoming evaluations, which are deemed necessary given that the results presented herein do not support the increase in both cross sections proposed in the recent INDEN evaluation., Funding for open access publishing: Universidad de Sevilla/CBUA. his measurement has received funding from the Euroatom research and training programme 2014-2018 under grant agreement No 847594 (ARIEL), and from the Spanish national projects RTI2018-098117-B-C21, PID2019-104714GB-C22, PID2021-123879 OB-C21 and PID2022-138297NB-C21. This work is also part of the PhD thesis of P. Pérez-Maroto at Universidad de Sevilla, Spain [53], funded through the FPI national Grant No PRE2019-089678. We also acknowledge the National Science Centre, Poland (Grant No. UMO-2021/41/B/ST2/00326)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade

  • n_TOF Collaboration
  • Lerendegui-Marco, J.
  • Casanovas, A.
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Domingo Pardo, César
  • Ladarescu, I.
The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the performance of both neutron beamlines at the experimental areas 1 and 2 (EAR1 and EAR2) and the commissioning of a new experimental area (NEAR). Due to improved coupling of the spallation target with the EAR2 beamline, the upgrade resulted in a significantly increased neutron flux and improved neutron energy resolution. This paper presents the results of the commissioning phase that followed to characterise the EAR2 neutron beamline and validate the FLUKA Monte Carlo simulations of the facility. The main characteristics of the neutron beam, namely the neutron flux, spatial profile and energy resolution, are evaluated and compared to the previous target. The neutron flux presents a general increase of 20% below 1 eV, 40% between 1 eV and 100 keV and 50% between 100 keV and 10 MeV. The measured width of the beam profile was 3 cm full width at half maximum (FWHM) at the reference position for neutron capture measurements. The energy resolution with the new spallation target shows a significant improvement compared to the previous one. Moreover, FLUKA Monte Carlo simulations present a good agreement with the measured neutron flux and profile within uncertainties, and a remarkable reproduction of the energy resolution., This work was financially supported by Grant PID2021-098117-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. Additionally, the authors thank the support of postdoctoral grants FJC2020-044688-I and CIAPOS/2022/020 funded, respectively, by MCIN AEI/10.13039/501100011033 and Generalitat Valenciana. Support from the funding agencies of all other participating institutes is gratefully acknowledged. The authors thank the n_TOF Collaboration members for their support during the commissioning campaign., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Single-event fast neutron time-of-flight spectrometry with a petawatt-laser-driven neutron source

  • Millán Callado, María de los Ángeles
  • Scheuren, S.
  • Alejo, Aarón
  • Benlliure, José
  • Beyer, R.
  • Cowan, T. E.
  • Fernández-Martínez, Begoña
  • Griesmayer, E.
  • Junghans, A. R.
  • Kohl, J.
  • Kroll, F.
  • Metzkes-Ng, J.
  • Prencipe, I.
  • Quesada, José Manuel
  • Rehwald, M.
  • Rödel, C.
  • Rodríguez-González, M. Teresa
  • Schramm, U.
  • Roth, M.
  • Štefaníková, R.
  • Urlass, S.
  • Weiss, C.
  • Zeil, K.
  • Ziegler, T.
  • Guerrero, C.
Laser-driven neutron sources (LDNSs) offer unique advantages for fundamental physics and applications: ultrashort pulses providing superior energy resolution, high instantaneous flux, and a reduced footprint. While single-event neutron spectroscopy has been demonstrated with epithermal neutrons, its application for fast neutrons is more challenging and remains unproven. This demands stable multi-shot operation and detectors resilient to this particularly extreme environment. Here, a proof-of-concept experiment at the DRACO PW laser is presented. This setup stably produced ~ 108 fast neutrons per shot sustained over more than 200 shots at a shot-per-minute rate. Neutron time-of-flight measurements with a diamond detector at only 150 cm from the source resolved individual neutron-induced reactions at a rate consistent with simulations informed by real-time diagnostics of accompanying gammas, ions, and electrons. Combined with the recent advances in the field, this work establishes LDNSs as a promising, scalable platform for future fast neutron-induced reaction studies, particularly those involving short-lived isotopes., The authors acknowledge financial support by: - The Spanish Ministry of Economy and Competitiveness (RYC-2014-15271, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PID2023-152894OA-I00 and RYC2021-032654I projects); - MAMC has received funding from the EC Euratom research and training program 2014-2018 under grant agreement No 847594 (ARIEL) and the EC PEOPLE Marie-Curie Action program 2007-2013 under grant agreement No 334315 (NeutAndalus); - Xunta de Galicia (grant ED431F2023/21, CIGUS Network of Research Centers); - “La Caixa” Foundation (ID 100010434), fellowship code LCF/BQ/PI20/11760027; - María de Maeztu grant CEX2023-001318-M funded by MICIU/AEI/10.13039/501100011033S; - The project was supported by Hi-Acts, an innovation platform under the grant of the Helmholtz Association HGF and funded by BMFTR under the project PLANET 13N16951- SSch acknowledges support from Trumpf SE + Co. KG; - CR acknowledges support from the LOEWE excellence program of the state of Hesse - This work was supported by CIVIDEC Instrumentation., Open Access funding enabled and organized by Projekt DEAL., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Neutron capture measurements for s-process nucleosynthesis: A review about CERN n_TOF developments and contributions

  • n_TOF Collaboration
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Fuente-Rosales, G. de la
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Tarifeño-Saldivia, A.
  • Torres-Sánchez, Pablo
This article presents a review about the main CERN n_TOF contributions to the field of neutron-capture experiments of interest for s-process nucleosynthesis studies over the last 25 years, with a special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on s-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the s-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented., The authors acknowledge support from all the funding agencies of participating institutions. Part of this work was supported by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC-COG Nr. 681740 and ERC-STG Nr.677497), European H2020-847552 (SANDA), the MCIN/AEI 10.13039/501100011033 under grants Severo Ochoa CEX2023-001292-S, PID2022-138297NB-C21, PID2019-104714GB-C21, FPA2017-83946-C2-1-P, FIS2015-71688-ERC, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PGC2018-096717-B-C21, PID2021-123100NB-I00 funded by MCIN/AEI 10.13039/501100011033/FEDER, UE, PCI2022-135037-2 funded by MCIN/AEI 10.13039/501100011033 and EU-NextGenerationEU/PRTR. The corresponding author has applied a Creative Commons Attribution (CC BY-NC-ND 4.0) license., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A new design of secondary electron detector for low-energy radioactive ion beam

  • Pancin, J.
  • Fernández-Martínez, Begoña
  • Fisichella, M.
  • Frémont, G.
  • Gangnant, P.
  • Goupil, J.
  • Herlant, S.
  • Balasmeh, Y.
  • Berthoumieux, E.
  • Caceres, L.
  • Chakma, R.
  • Doré, D.
  • Drouart, A.
  • Ducret, J. E.
  • Houarner, C.
  • Jacquot, B.
  • Piot, J.
  • Ramos, D.
  • Roger, T.
  • Saillant, F.
  • Savajols, H.
  • Spitaels, C.
  • Stodel, C.
  • Vos̆tinar, M.
  • Wittwer, G.
New facilities like FAIR at GSI or SPIRAL2 at GANIL, will permit to provide radioactive ion beams at low energies (less than 10 MeV per nucleon). Such beams have generally a large emittance, which requires the use of beam tracking detectors to reconstruct the exact trajectories of the nuclei. To reduce the angular and energy straggling that classical beam tracking detectors would generate in the beam due to their thickness, the use of SED (Secondary Electron Detectors) is proposed. In this work, the development and characterization of a low-pressure gaseous detector (around 10 mbar) based on wire chamber, coupled with an emissive foil placed in the beam path, is presented. Such systems are particularly well suited for low-energy radioactive ion beams, where the use of conventional tracking detectors can lead to significant energy loss and angular straggling due to the detector thickness. The performances achievable at very low pressure are excellent since the fast charge collection leads to excellent timing properties as well as high counting rate capabilities, even for a wire chamber. The spatial, temporal and counting rate performances of the final detector were measured both with radioactive source and a 238U beam. Spatial and time resolutions (𝜎) of about 0.7 mm and 150 ps were obtained, respectively, at high counting rates of 20 kHz/cm2 , demonstrating the reliable operation of the proposed detection system and confirming its suitability for beam-tracking applications at next generation radioactive ion beam facilities. A comparison of CF4 and iC4H10 was also performed, including systematic gain measurement, providing new insights concerning the behavior of these gases at very low pressure., Apart from the direct contribution of GANIL laboratory, this work was supported by S3 project that has been funded by the French Research Agency (ANR), through EQUIPEX (EQUIPment of EXcellence) ANR10-EQPX-46, the FEDER (Fond Européen en Développement Economique et Régional) and the CPER (Contrat Plan Etat Région). This work was also supported by the CNRS multipartner NEEDS program. Financial supports from the Spanish Ministry of Economy and Competitiveness (FPA2016-77689-C2-1 R project) and the Spanish Ministry of Science and Innovation (RTI2018-098117-B-C21, PID2021-123879OB-C21 projects) were also obtained., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Neutron activation as benchmark for cross section evaluations: demonstration through the MACS of 50Cr for nuclear technology applications

  • Pérez Maroto, Pablo
  • Guerrero, Carlos
  • Fernández, B.
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Stamati, Maria Elisso
Neutron cross section libraries often differ with each other due to the limited availability of differential cross section data from time-of-flight experiments. These are indeed challenging, requiring state-of-the-art facilities and detectors, as well as an involved data analysis. However, in some cases, an easier alternative can be found in simpler integral experiments, as it is demonstrated herein. The capture cross section of 50Cr plays an important role in nuclear reactors and recent criticality safety benchmarks pointed to an increase of 20%, which has been incorporated in the recent INDEN (2023) evaluated library. In this work we have carried out an epithermal neutron activation measurement on 50Cr at the CNA HiSPANoS facility. The resulting Maxwellian Average Cross Section (MACS) at 30 keV, 37.1(20) mb, provides enough evidence to discard the proposed increase in the cross section. Furthermore, it illustrates the suitability of the activation technique to benchmark cross section evaluations in the epithermal energy region. This can in principle be extended to other reactions (as far as they result in radioactive nuclei) and to the fast neutron range by employing mono-energetic beams from D-D and D-T reactions in similarly simple experiments., The authors gratefully acknowledge the contribution of Dr. Emilio Mendoza (CIEMAT), who created on demand the GEANT4 nuclear data files corresponding to the latest INDEN evaluation. We would like to thank also Ángel Romero and David Pascual for operating the accelerator during the experiment. This measurement has received funding from the Euratom Research and Training Programme 2014-2018 under grant agreement No 847594 (ARIEL), and from the Spanish national projects RTI2018-098117-B-C21 and PID2021-123879OB-C21. From the UPC side, we would like to acknowledge also Spanish projects PID2019-104714GB-C21 and PID2022-138297NB-C21. The work presented herein is part of the PhD thesis of P. Pérez-Maroto at Universidad de Sevilla, Spain, funded through the FPI national Grant No PRE2019-089678., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Neutron activation as benchmark for cross section evaluations: demonstration through the MACS of 50Cr for nuclear technology applications

  • Pérez Maroto, Pablo
  • Guerrero, Carlos
  • Fernández, B.
  • Casanovas Hoste, Adrià
  • Stamati, Maria Elisso
Neutron cross section libraries often differ with each other due to the limited availability of differential cross section data from time-of-flight experiments. These are indeed challenging, requiring state-of-the-art facilities and detectors, as well as an involved data analysis. However, in some cases, an easier alternative can be found in simpler integral experiments, as it is demonstrated herein. The capture cross section of 50Cr plays an important role in nuclear reactors and recent criticality safety benchmarks pointed to an increase of 20%, which has been incorporated in the recent INDEN (2023) evaluated library. In this work we have carried out an epithermal neutron activation measurement on 50Cr at the CNA HiSPANoS facility. The resulting Maxwellian Average Cross Section (MACS) at 30 keV, 37.1(20) mb, provides enough evidence to discard the proposed increase in the cross section. Furthermore, it illustrates the suitability of the activation technique to benchmark cross section evaluations in the epithermal energy region. This can in principle be extended to other reactions (as far as they result in radioactive nuclei) and to the fast neutron range by employing mono-energetic beams from D-D and D-T reactions in similarly simple experiments., The authors gratefully acknowledge the contribution of Dr. Emilio Mendoza (CIEMAT), who created on demand the GEANT4 nuclear data files corresponding to the latest INDEN evaluation. We would like to thank also Ángel Romero and David Pascual for operating the accelerator during the experiment. This measurement has received funding from the Euratom Research and Training Programme 2014-2018 under grant agreement No 847594 (ARIEL), and from the Spanish national projects RTI2018-098117-B-C21 and PID2021-123879OB-C21. From the UPC side, we would like to acknowledge also Spanish projects PID2019-104714GB-C21 and PID2022-138297NB-C21. The work presented herein is part of the PhD thesis of P. Pérez-Maroto at Universidad de Sevilla, Spain, funded through the FPI national Grant No PRE2019-089678., Peer Reviewed, Postprint (published version)