Pasar al contenido principal

N_TOF CONTRIBUTION

PCI2022-135037-2

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Afrontar las Prioridades de Nuestro Entorno
Subprograma Subprograma Estatal de Internacionalización
Convocatoria Proyectos Programación Conjunta Internacional
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario CENTRO DE INVESTIGACION ENERGETICA MEDIOAMBIENTAL Y TECNOLOGICA (CIEMAT)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

  • Balibrea-Correa, Javier
  • Caamaño Fresco, Manuel
  • Durán Escribano, Ignacio
  • Fernández Domínguez, Beatriz
  • Žugec, Petar C.
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C6D6 detectors, and one LaCl3(Ce) detector. The performance of these detection systems is compared using 93Nb(n, γ) data. We also developed a detailed GEANT4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

  • Balibrea, Javier
  • Babiano-Suárez, V.
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Ladarescu, I.
  • Tarifeño-Saldivia, A.
  • Fuente-Rosales, G. de la
  • Gameiro, B.
  • Zaitseva, N.
  • Alcayne, V.
  • Cano-Ott, D.
  • González-Romero, E.
  • Martínez, T.
  • Mendoza, E.
  • de Rada, A.P.
  • del Olmo, J.P.
  • Sánchez-Caballero, A.
  • Casanovas, A.
  • Calviño, F.
  • Valenta, S.
  • Aberle, O.
  • Altieri, S.
  • Amaducci, S.
  • Andrzejewski, J.
  • Bacak, M.
  • Beltrami, C.
  • Bennett, S.
  • Bernardes, A.P.
  • Berthoumieux, E.
  • Beyer, R.
  • Boromiza, M.
  • Bosnar, D.
  • Caamaño, M.
  • Calviani, M.
  • Castelluccio, D.M.
  • Cerutti, F.
  • Cescutti, G.
  • Chasapoglou, S.
  • Chiaveri, E.
  • Colombetti, P.
  • Colonna, N.
  • Camprini, P.C.
  • Cortés, G.
  • Cortés-Giraldo, M.A.
  • Cosentino, L.
  • Cristallo, S.
  • Dellmann, S.
  • Di Castro, M.
  • Di Maria, S.
  • Diakaki, M.
  • Dietz, M.
  • Dressler, R.
  • Dupont, E.
  • Durán, I.
  • Eleme, Z.
  • Fargier, S.
  • Fernández, B.
  • Fernández-Domínguez, B.
  • Finocchiaro, P.
  • Fiore, S.
  • Furman, V.
  • García-Infantes, F.
  • Gawlik-Ramikega, A.
  • Gervino, G.
  • Gilardoni, S.
  • Guerrero, C.
  • Gunsing, F.
  • Gustavino, C.
  • Heyse, J.
  • Hillman, W.
  • Jenkins, D.G.
  • Jericha, E.
  • Junghans, A.
  • Kadi, Y.
  • Kaperoni, K.
  • Kaur, G.
  • Kimura, A.
  • Knapová, I.
  • Kokkoris, M.
  • Kopatch, Y.
  • Krtička, M.
  • Kyritsis, N.
  • Lederer-Woods, C.
  • Lerner, G.
  • Manna, A.
  • Masi, A.
  • Massimi, C.
  • Mastinu, P.
  • Mastromarco, M.
  • Maugeri, E.A.
  • Mazzone, A.
  • Mengoni, A.
  • Michalopoulou, V.
  • Milazzo, P.M.
  • Mucciola, R.
  • Murtas, F.
  • Musacchio-Gonzalez, E.
  • Musumarra, A.
  • Negret, A.
  • Pérez-Maroto, P.
  • Patronis, N.
  • Pavón-Rodríguez, J.A.
  • Pellegriti, M.G.
  • Perkowski, J.
  • Petrone, C.
  • Pirovano, E.
  • Pomp, S.
  • Porras, I.
  • Praena, J.
  • Quesada, J.M.
  • Reifarth, R.
  • Rochman, D.
  • Romanets, Y.
  • Rubbia, C.
  • Sabaté-Gilarte, M.
  • Schillebeeckx, P.
  • Schumann, D.
  • Sekhar, A.
  • Smith, A.G.
  • Sosnin, N.V.
  • Stamati, M.E.
  • Sturniolo, A.
  • Tagliente, G.
  • Tarrío, D.
  • Torres-Sánchez, P.
  • Vagena, E.
  • Variale, V.
  • Vaz, P.
  • Vecchio, G.
  • Vescovi, D.
  • Vlachoudis, V.
  • Vlastou, R.
  • Wallner, A.
  • Woods, P.J.
  • Wright, T.
  • Zarrella, R.
  • Žugec, P.
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C6D6 detectors, and one LaCl3(Ce) detector. The performance of these detection systems is compared using 93Nb(n, γ) data. We also developed a detailed GEANT4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability. © 2024, The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PID2019-104714GB-C21, PID2022-138297NB-C21 and the financial support from MCIN, PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and the European Union NextGenerationEU and Generalitat Valenciana in the call PRTR PC I+D+i ASFAE/2022/027. This work was supported by European Union NextGeneration EU/PRTR project C17.I02.P02-SGI_GICS Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, subproject C17.I02.P02.S01.S03 CSIC CERN. The corresponding author JB acknowledges support from grant ICJ220-045122-I funded by MCIN/AEI/10.13039/501100011033. Author VB is a beneficiary of the Margarita Salas grant (MS21- 178) for the requalification of the Spanish university system from the Ministry of Universities of the Government of Spain, financed by the European Union, NextGenerationUE. Author JL acknowledges the support provided by postdoctoral grants FJC2020-044688-I by MCIN/AEI/10.13039/501100011033 and CIAPOS/2022/020 funded by the Generalitat Valenciana and the European Social Fund and a PhD grant PRE2023 from CSIC . The work on stilbene-d12 development was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Support from the funding agencies of all other participating institutes are also gratefully acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Neutron capture measurements for s-process nucleosynthesis: A review about CERN n_TOF developments and contributions

  • n_TOF Collaboration
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Fuente-Rosales, G. de la
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Tarifeño-Saldivia, A.
  • Torres-Sánchez, Pablo
This article presents a review about the main CERN n_TOF contributions to the field of neutron-capture experiments of interest for s-process nucleosynthesis studies over the last 25 years, with a special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on s-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the s-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented., The authors acknowledge support from all the funding agencies of participating institutions. Part of this work was supported by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC-COG Nr. 681740 and ERC-STG Nr.677497), European H2020-847552 (SANDA), the MCIN/AEI 10.13039/501100011033 under grants Severo Ochoa CEX2023-001292-S, PID2022-138297NB-C21, PID2019-104714GB-C21, FPA2017-83946-C2-1-P, FIS2015-71688-ERC, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PGC2018-096717-B-C21, PID2021-123100NB-I00 funded by MCIN/AEI 10.13039/501100011033/FEDER, UE, PCI2022-135037-2 funded by MCIN/AEI 10.13039/501100011033 and EU-NextGenerationEU/PRTR. The corresponding author has applied a Creative Commons Attribution (CC BY-NC-ND 4.0) license., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

  • Balibrea Correa, Javier
  • Babiano Suárez, Víctor
  • Lerendegui Marco, Jorge
  • Domingo Pardo, César
  • Ladarescu, Ion
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
  • Fuente Rosales, Gabriel de la
  • Gameiro, Bernardo
  • Zaitseva, Natalia P.
  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • González Romero, Enrique Miguel
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called -flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C6D6 detectors, and one LaCl3(Ce) detector. The performance of these detection systems is compared using 93Nb(, ) data. We also developed a detailed Geant4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability. Previous article in issue Next article in issue, The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PID2019-104714GB-C21, PID2022-138297NB-C21 and the financial support from MCIN, PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and the European Union NextGenerationEU and Generalitat Valenciana in the call PRTR PC I+D+i ASFAE/2022/027. This work was supported by European Union NextGeneration EU/PRTR project C17.I02.P02-SGI_GICS Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, subproject C17.I02.P02.S01.S03 CSIC CERN. The corresponding author JB acknowledges support from grant ICJ220-045122-I funded by MCIN/AEI/10.13039/501100011033. Author VB is a beneficiary of the Margarita Salas grant (MS21- 178) for the requalification of the Spanish university system from the Ministry of Universities of the Government of Spain, financed by the European Union, NextGenerationUE. Author JL acknowledges the support provided by postdoctoral grants FJC2020-044688-I by MCIN/AEI/10.13039/501100011033 and CIAPOS/2022/020 funded by the Generalitat Valenciana and the European Social Fund and a PhD grant PRE2023 from CSIC . The work on stilbene-d12 development was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Support from the funding agencies of all other participating institutes are also gratefully acknowledged., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

  • Balibrea Correa, Javier
  • Babiano Suárez, Víctor
  • Lerendegui Marco, Jorge
  • Domingo Pardo, César
  • Ladarescu, Ion
  • Tarifeño Saldivia, Ariel Esteban
  • Fuente Rosales, Gabriel de la
  • Gameiro, Bernardo
  • Zaitseva, Natalia P.
  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • González Romero, Enrique Miguel
  • Casanovas Hoste, Adrià
  • Calviño Tavares, Francisco
  • Cortés Rossell, Guillem Pere
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called -flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C6D6 detectors, and one LaCl3(Ce) detector. The performance of these detection systems is compared using 93Nb(, ) data. We also developed a detailed Geant4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability. Previous article in issue Next article in issue, The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PID2019-104714GB-C21, PID2022-138297NB-C21 and the financial support from MCIN, PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and the European Union NextGenerationEU and Generalitat Valenciana in the call PRTR PC I+D+i ASFAE/2022/027. This work was supported by European Union NextGeneration EU/PRTR project C17.I02.P02-SGI_GICS Nuevas actuaciones en grandes infraestructuras de investigación europeas e internacionales, subproject C17.I02.P02.S01.S03 CSIC CERN. The corresponding author JB acknowledges support from grant ICJ220-045122-I funded by MCIN/AEI/10.13039/501100011033. Author VB is a beneficiary of the Margarita Salas grant (MS21- 178) for the requalification of the Spanish university system from the Ministry of Universities of the Government of Spain, financed by the European Union, NextGenerationUE. Author JL acknowledges the support provided by postdoctoral grants FJC2020-044688-I by MCIN/AEI/10.13039/501100011033 and CIAPOS/2022/020 funded by the Generalitat Valenciana and the European Social Fund and a PhD grant PRE2023 from CSIC . The work on stilbene-d12 development was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Support from the funding agencies of all other participating institutes are also gratefully acknowledged., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed, Postprint (published version)