Microdosimetry performance of the first multi-arrays of 3D-cylindrical microdetectors
The present work reports on the microdosimetry measurements performed with the two first multi-arrays of microdosimeters with the highest radiation sensitive surface covered so far. The sensors are based on new silicon-based radiation detectors with a novel 3D cylindrical architecture. Each system consists of arrays of independent microdetectors covering 2 mm× 2 mm and 0.4 mm× 12 cm radiation sensitive areas, the sensor distributions are arranged in layouts of 11× 11 microdetectors and 3× 3 multi-arrays, respectively. We have performed proton irradiations at several energies to compare the microdosimetry performance of the two systems, which have different spatial resolution and detection surface. The unitcell of both arrays is a 3D cylindrical diode with a 25 μm diameter and a 20 μm depth that results in a welldefined and isolated radiation sensitive micro-volume etched inside a silicon wafer. Measurements were carried out at the Accélérateur Linéaire et Tandem à Orsay (ALTO) facility by irradiating the two detection systems with monoenergetic proton beams from 6 to 20 MeV at clinical-equivalent fluence rates. The microdosimetry quantities were obtained with a spatial resolution of 200 μm and 600 μm for the 11× 11 system and for the 3× 3 multi-array system, respectively. Experimental results were compared with Monte Carlo simulations and an overall good agreement was found. The good performance of both microdetector arrays demonstrates that this architecture and both configurations can be used clinically as microdosimeters for measuring the lineal energy distributions and, thus, for RBE optimization of hadron therapy treatments. Likewise, the results have shown that the devices can be also employed as a multipurpose device for beam monitoring in particle accelerators., he 3D-cylindrical microdetectors fabrication was funded from the H2020 project AIDA-2020, GA no. 654168
(second run) and from the European Union’s Horizon research and innovation program under the Marie
Skłodowska-Curie grant agreement No 745109 (third run). This work made use of the Spanish ICTS Network
MICRONANOFABS partially supported by MEINCOM. D. Bachiller-Perea and C. Guardiola thanks the funding
from the CNRS-Momentum fellow and the staff of the ALTO facility for their help to perform the calibration
tests. C. Guardiola gratefully acknowledges the support from the CNRS/IN2P3 Computing Center (Lyon, France)
for providing the computing and data-processing resources needed for this work. Authors thank C. Lacasta and
G. Llosá for their advices for addressing issues related to the readout electronics., Peer reviewed