Pasar al contenido principal

Particle acceleration using ultra-intense lasers

RYC2021-032654-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDADE DE SANTIAGO DE COMPOSTELA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Optimisation of a laser-driven X-ray source operating in air

  • Reija-Vecino, Alicia
  • Coathup, Andrew
  • Alejo, Aarón
  • Bembibre, Adrián
  • Contreras-Martínez, Ramiro
  • Peñas, Juan
  • Ruiz, Camilo
  • Benlliure, Jose
  • Seimetz, Michael
[EN] X-ray sources with high photon fluxes and small source sizes have been widely pursued in the last decades. With synchrotron and XFEL facilities being complex, scarce and not easily accessible, laser-driven x-ray sources have emerged as a promising option because of their compactness, high photon yield and micrometric source size. In this work, we present the optimisation of an x-ray source driven by means of 0.8 mJ, 35 fs laser pulses focused on a solid Cu target in air. A detailed characterisation of the main x-ray beam parameters is included. A Cu K alpha flux of 2.3<middle dot>10(9) photons/s has been measured in 2 pi sr. Despite the simplicity of our setup, this flux is competitive with respect to that achieved with vacuum-based sources. A clear non-isotropic distribution of the x-ray continuum has been recorded, differing from the isotropic emission reported in dedicated studies. The beam is emitted within a cone with a semiangle of approximate to 14 degrees, directed primarily along the target normal. Given the achieved flux, this source stands as a competitive alternative to more complex laser-driven x-ray sources operating in vacuum or in a He environment. (c) 2025 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement, Funding. 'la Caixa' Foundation (LCF/BQ/PI20/11760027) ; Xunta de Galicia (ED431F2023/21, CIGUS Network of Research Centres) ; Agencia Estatal de Investigacion (PID2023-152894OA-I00, RYC2021-032654I, CEX2023-001318-M) ; Generalitat Valenciana (CIAICO/2022/008) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A multi-shot target wheel assembly for high-repetition-rate, laser-driven proton acceleration

  • Peñas, J.
  • Bembibre, Adrian
  • Cortina-Gil, D.
  • Martín, L.
  • Reija, A.
  • Ruiz, C.
  • Alejo, Aaron
  • Benlliure, Jose
  • Seimetz, Michael
[EN] A multi-shot target assembly and automatic alignment procedure for laser-plasma proton acceleration at high repetition rate are introduced. The assembly is based on a multi-target rotating wheel capable of hosting more than 5000 targets, mounted on a 3D motorized stage to allow rapid replenishment and alignment of the target material between laser irradiations. The automatic alignment procedure consists of a detailed mapping of the impact positions at the target surface prior to the irradiation that ensures stable operation of the target, which alongside the purpose-built design of the target wheel, enables operation at rates up to 10 Hz. Stable and continuous laser-driven proton acceleration at 10 Hz is demonstrated, with observed cut-off energy stability about 15%., This work was supported by the Spanish Ministerio de Ciencia, Innovacion y Universidades under grants RTI2018-101578-B-C21, RTI2018-101578-B-C22, FPI predoctorals BES-2017-08917 and PRE2019-090730, and Unidad de Excelencia Maria de Maetzu under project MdM-2016-0692-17-2, the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21 and a grant of the program Grupos de investigacion consolidados (CIAICO/2022/008) financed by Generalitat Valenciana. Action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014-2020 (IDIFEDER/2021/002). This work was supported by 'la Caixa' Foundation (ID 100010434) (fellowship code LCF/BQ/PI20/11760027) and grant RYC2021-032654-I funded by MICIU/AEI/10.13039/501100011033 and by 'European Union NextGenerationEU'.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design and Implementation of an Energy Selector for Laser-Accelerated Protons

  • Reija-Vecino, Alicia
  • Esteban, David
  • Alejo, Aaron
  • Apiñaniz, Jon Imanol
  • Bembibre, Adrian
  • Benlliure, José
  • Ehret, Michael
  • García López, Javier
  • Jiménez-Ramos, M. Carmen
  • Méndez, Cruz
  • Pascual, David
  • Rodríguez Frías, M. Dolores
  • Rodríguez Ramos, Mauricio
  • Juan-Morales, Jéssica|||0009-0005-9962-3973
  • Seimetz, Michael
[EN] Highly intense bunches of protons and ions with energies of several MeV/u can be generated with ultra-short laser pulses focused on solid targets. In the most common interaction regime, target normal sheath acceleration, the spectra of these particles are spread over a wide range following a Maxwellian distribution. We report on the design and testing of a magnetic chicane for the selection of protons within a limited energy window. This consisted of two successive, anti-parallel dipole fields generated by cost-effective permanent C-magnets with customized configuration and longitudinal positions. The chicane was implemented into the target vessel of a petawatt laser facility with constraints on the direction of the incoming laser beam and guidance of the outgoing particles through a vacuum port. The separation of protons and carbon ions within distinct energy intervals was demonstrated and compared to a ray tracing code. Measurements with radiochromic film stacks indicated the selection of protons within [2.4, 6.9] MeV, [5.0, 8.4] MeV, or ¿6.9 MeV depending on the lateral dispersion. A narrow peak at 4.8 MeV was observed with a time-of-flight detector., Project CIAICO/2022/008 funded by the regional government (Generalitat Valenciana) within the program I+D+i Subvenciones para grupos de investigación consolidados AICO . Additional support by Generalitat Valenciana in the Garantía Juvenil program, ref. EDGJID/2021/204. The authors would like to thank the Spanish Center of Pulsed Lasers (CLPU) and the members of the Consortium (Central Government, Regional Government of Castilla y León and Universidad de Salamanca) for considering experiment 00562-0101 as a strategic proposal that develops new potentialities for CLPU and, therefore, for financing the access to its facilities; they also acknowledge the results obtained with its petawatt laser system (VEGA-3) and its scientific and technical assistance. Supported by the Government of Castilla y León under the project CLP263P20 Transport and manipulation of particles in laser accelerators: New scenarios in flash radiotherapy (TYMPAL) , co-financed with FEDER funds. M. Carmen Jiménez-Ramos acknowledges the support of this work through a VI PPIT-US contract. Work supported by the Xunta de Galicia grant ED431F2023/21, by la Caixa Foundation (ID 100010434) (fellowship code LCF/BQ/PI20/11760027) and grant RYC2021-032654I funded by MICIU/AEI/10.13039/501100011033 and by European Union NextGenerationEU .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Production of carbon-11 for PET preclinical imaging using a high-repetition rate laser-driven proton source

  • Peñas, Juan
  • Alejo, Aaron
  • Bembibre, Adrian
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, Carlos
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán-Callado, María Ángeles
  • Puyuelo-Valdés, Pilar
  • Benlliure, José
  • Seimetz, Michael
[EN] Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the frst time the use of a high-repetition rate, ultraintense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10¿14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11B(p,n)11C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Signifcant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-theart technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the Maria de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovacion y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by 'la Caixa' Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by 'European Union NextGenerationEU'.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Design and Implementation of an Energy Selector for Laser-Accelerated Protons

  • Reija, Alicia
  • Esteban, David
  • Alejo, Aarón
  • Apiñaniz, Jon Imanol
  • Bembibre, Adrián
  • Benlliure, José
  • Ehret, Michael
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Juan-Morales, Jessica
  • Méndez, Cruz
  • Pascual, David
  • Frías, M. Dolores Rodríguez
  • Rodríguez-Ramos, M.
  • Seimetz, Michael
Highly intense bunches of protons and ions with energies of several MeV/u can be generated with ultra-short laser pulses focused on solid targets. In the most common interaction regime, target normal sheath acceleration, the spectra of these particles are spread over a wide range following a Maxwellian distribution. We report on the design and testing of a magnetic chicane for the selection of protons within a limited energy window. This consisted of two successive, anti-parallel dipole fields generated by cost-effective permanent C-magnets with customized configuration and longitudinal positions. The chicane was implemented into the target vessel of a petawatt laser facility with constraints on the direction of the incoming laser beam and guidance of the outgoing particles through a vacuum port. The separation of protons and carbon ions within distinct energy intervals was demonstrated and compared to a ray tracing code. Measurements with radiochromic film stacks indicated the selection of protons within [2.4, 6.9] MeV, [5.0, 8.4] MeV, or ≥6.9 MeV depending on the lateral dispersion. A narrow peak at 4.8 MeV was observed with a time-of-flight detector., Project CIAICO/2022/008 funded by the regional government (Generalitat Valenciana) within the program “I+D+i Subvenciones para grupos de investigación consolidados AICO”. Additional support by Generalitat Valenciana in the Garantía Juvenil program, ref. EDGJID/2021/204. The authors would like to thank the Spanish Center of Pulsed Lasers (CLPU) and the members of the Consortium (Central Government, Regional Government of Castilla y León and Universidad de Salamanca) for considering experiment 00562-0101 as a strategic proposal that develops new potentialities for CLPU and, therefore, for financing the access to its facilities; they also acknowledge the results obtained with its petawatt laser system (VEGA-3) and its scientific and technical assistance. Supported by the Government of Castilla y León under the project CLP263P20 “Transport and manipulation of particles in laser accelerators: New scenarios in flash radiotherapy (TYMPAL)”, co-financed with FEDER funds. M. Carmen Jiménez-Ramos acknowledges the support of this work through a VI PPIT-US contract. Work supported by the Xunta de Galicia grant ED431F2023/21, by “la Caixa” Foundation (ID 100010434) (fellowship code LCF/BQ/PI20/11760027) and grant RYC2021-032654I funded by MICIU/AEI/10.13039/501100011033 and by “European Union NextGenerationEU”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Production of carbon‑11 for PET preclinical imaging using a high‑repetition rate laser‑driven proton source

  • Peñas, Juan
  • Alejo, Aarón
  • Bembibre, Adrián
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, C.
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán Callado, María de los Ángeles
  • Puyuelo-Valdés, Pilar
  • Seimetz, Michael
  • Benlliure, José
Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the first time the use of a high-repetition rate, ultra-intense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10-14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11 B(p,n) 11 C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Significant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-the-art technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the María de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovación y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by ‘la Caixa’ Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by ‘European Union NextGenerationEU., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Optimisation of a laser-driven X-ray source operating in air

  • Reija, Alicia
  • Coathup, Andrew
  • Alejo, Aarón
  • Bembibre, Adrián
  • Contreras-Martínez, Ramiro
  • Peñas, Juan
  • Ruiz, Camilo
  • Seimetz, Michael
  • Benlliure, J.
© 2025 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement, X-ray sources with high photon fluxes and small source sizes have been widely pursued in the last decades. With synchrotron and XFEL facilities being complex, scarce and not easily accessible, laser-driven x-ray sources have emerged as a promising option because of their compactness, high photon yield and micrometric source size. In this work, we present the optimisation of an x-ray source driven by means of 0.8 mJ, 35 fs laser pulses focused on a solid Cu target in air. A detailed characterisation of the main x-ray beam parameters is included. A Cu Kα flux of 2.3·109 photons/s has been measured in 2π sr. Despite the simplicity of our setup, this flux is competitive with respect to that achieved with vacuum-based sources. A clear non-isotropic distribution of the x-ray continuum has been recorded, differing from the isotropic emission reported in dedicated studies. The beam is emitted within a cone with a semiangle of ≈14°, directed primarily along the target normal. Given the achieved flux, this source stands as a competitive alternative to more complex laser-driven x-ray sources operating in vacuum or in a He environment., 'la Caixa' Foundation (LCF/BQ/PI20/11760027); Xunta de Galicia (ED431F2023/21, CIGUS Network of Research Centres); Agencia Estatal de Investigación (PID2023-152894OA-I00, RYC2021-032654I, CEX2023-001318-M); Generalitat Valenciana (CIAICO/2022/008)., With funding form the Spanish government through the “María de Maeztu Unit of Excellence” accreditation (CEX2023-001318-M)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Single-event fast neutron time-of-flight spectrometry with a petawatt-laser-driven neutron source

  • Millán Callado, María de los Ángeles
  • Scheuren, S.
  • Alejo, Aarón
  • Benlliure, José
  • Beyer, R.
  • Cowan, T. E.
  • Fernández-Martínez, Begoña
  • Griesmayer, E.
  • Junghans, A. R.
  • Kohl, J.
  • Kroll, F.
  • Metzkes-Ng, J.
  • Prencipe, I.
  • Quesada, José Manuel
  • Rehwald, M.
  • Rödel, C.
  • Rodríguez-González, M. Teresa
  • Schramm, U.
  • Roth, M.
  • Štefaníková, R.
  • Urlass, S.
  • Weiss, C.
  • Zeil, K.
  • Ziegler, T.
  • Guerrero, C.
Laser-driven neutron sources (LDNSs) offer unique advantages for fundamental physics and applications: ultrashort pulses providing superior energy resolution, high instantaneous flux, and a reduced footprint. While single-event neutron spectroscopy has been demonstrated with epithermal neutrons, its application for fast neutrons is more challenging and remains unproven. This demands stable multi-shot operation and detectors resilient to this particularly extreme environment. Here, a proof-of-concept experiment at the DRACO PW laser is presented. This setup stably produced ~ 108 fast neutrons per shot sustained over more than 200 shots at a shot-per-minute rate. Neutron time-of-flight measurements with a diamond detector at only 150 cm from the source resolved individual neutron-induced reactions at a rate consistent with simulations informed by real-time diagnostics of accompanying gammas, ions, and electrons. Combined with the recent advances in the field, this work establishes LDNSs as a promising, scalable platform for future fast neutron-induced reaction studies, particularly those involving short-lived isotopes., The authors acknowledge financial support by: - The Spanish Ministry of Economy and Competitiveness (RYC-2014-15271, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PID2023-152894OA-I00 and RYC2021-032654I projects); - MAMC has received funding from the EC Euratom research and training program 2014-2018 under grant agreement No 847594 (ARIEL) and the EC PEOPLE Marie-Curie Action program 2007-2013 under grant agreement No 334315 (NeutAndalus); - Xunta de Galicia (grant ED431F2023/21, CIGUS Network of Research Centers); - “La Caixa” Foundation (ID 100010434), fellowship code LCF/BQ/PI20/11760027; - María de Maeztu grant CEX2023-001318-M funded by MICIU/AEI/10.13039/501100011033S; - The project was supported by Hi-Acts, an innovation platform under the grant of the Helmholtz Association HGF and funded by BMFTR under the project PLANET 13N16951- SSch acknowledges support from Trumpf SE + Co. KG; - CR acknowledges support from the LOEWE excellence program of the state of Hesse - This work was supported by CIVIDEC Instrumentation., Open Access funding enabled and organized by Projekt DEAL., Peer reviewed