Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Tesis doctoral (DoctoralThesis)

Production and measurement of low-energy neutrons using accelerator-based neutron sources for applications in medicine

  • Verdera Garau, Antònia
Accelerator-based neutron sources are currently in the spotlight due to the wide range of uses, particularly in medical applications, such as Boron Neutron Capture Therapy (BNCT). Conventional BNCT facilities, either based on nuclear reactors or on accelerators, require a moderation system or a Beam Shaping Assembly (BSA) to tailor the neutron spectrum, adding complexity, important maintenance and operation and avoiding flexibility in the neutron field. To overcome these challenges, this work proposes a novel approach leveraging the 51V(p,n) and 45Sc(p,n) reactions near their thresholds, eliminating the need for moderation and fulfilling the quality factors established by the International Atomic Energy Agency (IAEA) for BNCT. Neutron time-of-flight measurements were conducted at the accelerator-based neutron facility MONNET at the Joint Research Centre in Geel, Belgium. First, experiments were performed using as a reference the well-known 7Li(p,n) nearthreshold reaction. Subsequently, angle-dependent measurements were carried out for the 51V(p,n) reaction near its threshold, including the integrated neutron spectrum produced by this reaction. The results of the experiments with the 51V(p,n) reaction and the studies on 45Sc(p,n) reaction using available data, demonstrate that the proposed neutron sources achieve the IAEA quality factors with comparable figures of merit to existing BNCT facilities. In particular, the 45Sc(p,n) reaction can be used with available accelerators, meanwhile 51V(p,n) would need higher proton currents than existing accelerators. This approach not only simplifies the design of acceleratorbased BNCT facilities but also enables fine-tuning of neutron penetration depth into the human body through small adjustments in proton energy, opening new possibilities for treatment optimization. This thesis makes significant contributions to the field of accelerator-based neutron sources by providing high-precision experimental data and proposing an innovative approach to neutron generation for BNCT. This new proposal has been submitted as a patent., Las fuentes de neutrones basadas en aceleradores están actualmente en el punto de mira debido a su amplia gama de aplicaciones, especialmente en el ámbito médico, como la Terapia por Captura de Neutrones en Boro (BNCT). Las instalaciones convencionales de BNCT, ya sean basadas en reactores nucleares o en aceleradores, requieren un sistema de moderación o un Ensamblaje de Modelado del Espectro (BSA) para ajustar el espectro de neutrones, lo que añade complejidad, exige un mantenimiento considerable y limita la flexibilidad del campo de neutrones. Para superar estos desafíos, este trabajo propone un enfoque novedoso que aprovecha las reacciones 51V(p,n)51V(p,n) y 45Sc(p,n)45Sc(p,n) cerca de sus umbrales, eliminando la necesidad de moderación, al tiempo que se cumplen los factores de calidad de neutrones establecidos por la Agencia Internacional de Energía Atómica (IAEA) para BNCT. Las mediciones de tiempo de vuelo de neutrones se llevaron a cabo en la instalación de neutrones basada en aceleradores MONNET, en el Joint Research Centre de Geel, Bélgica. En primer lugar, se realizaron experimentos utilizando como referencia la bien conocida reacción 7Li(p,n)7Li(p,n) cerca de su umbral. Posteriormente, se efectuaron mediciones dependientes del ángulo para la reacción 51V(p,n)51V(p,n), incluyendo el espectro de neutrones integrado producido por esta reacción. Los experimentos realizados con la reacción 51V(p,n)51V(p,n), junto con estudios sobre 45Sc(p,n)45Sc(p,n) basados en datos disponibles, demuestran que las fuentes de neutrones propuestas alcanzan los factores de calidad definidos por la IAEA, con figuras de mérito comparables a las de las instalaciones actuales de BNCT. En particular, la reacción 45Sc(p,n)45Sc(p,n) puede utilizarse con los aceleradores disponibles, mientras que la reacción 51V(p,n)51V(p,n) requeriría corrientes de protones más altas que las que ofrecen los aceleradores actuales. Este enfoque no solo simplifica el diseño de las instalaciones de BNCT basadas en aceleradores, sino que también permite un ajuste preciso de la profundidad de penetración de los neutrones en el cuerpo humano mediante pequeñas modificaciones en la energía de los protones, abriendo nuevas posibilidades para la optimización del tratamiento. Se espera que el enfoque propuesto contribuya significativamente a la simplificación de las instalaciones de BNCT basadas en aceleradores. Esta tesis ha realizado aportes relevantes en el campo de las fuentes de neutrones basadas en aceleradores, proporcionando datos experimentales de alta precisión y proponiendo un enfoque innovador para la generación de neutrones en BNCT. Esta nueva propuesta ha sido presentada como patente., Tesis Univ. Granada., Euratom Research and Training Programme 2014-2018 under grant agreement No. 847594
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Measurement of the neutron spectrum of the 51V(p,n)51Cr reaction at 1585 keV

  • Verdera Garau, Antònia
  • Praena Rodríguez, Antonio Javier
  • Arias De Saavedra Alias, Fernando|||0000-0001-9895-8740
  • Roldán Aranda, Andrés María|||0000-0001-6807-7053
  • Macías, Miguel
  • Fontana, C. L.
  • Bonaldi, C.
  • Geerts, W.
  • Oberstedt, S.
Euratom research and training program 2014–2018 under Grant Agreement No. 847594 (ARIEL)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Research facilities and highlights at the Centro Nacional de Aceleradores (CNA)

  • Gómez-Camacho, Joaquín
  • García López, J.
  • López-Gutiérrez, J. M.
  • García-Tenorio, R.
  • Santos, F. J.
  • Chamizo, Elena
  • Ferrer, F. J.
  • Jiménez-Ramos, M. C.
  • Balcerzyk, Marcin
  • Fernández-Martínez, Begoña
Part of a collection: Focus Point on Small and Medium and Particle Accelerator Facilities in Europe, The Centro Nacional de Aceleradores is a user-oriented accelerator facility in Seville, Spain. Its main facilities are a 3 MV tandem accelerator, an 18 MeV proton Cyclotron, a tandetron used for AMS, a compact accelerator used for radiocarbon measurements, a Co irradiator and a PET/CT scanner. The technical specifications and research applications of these facilities are described. A neutron beam line associated to a charged pulsed beam in the tandem allows for time of flight measurements which determine the neutron energy. The use of an adequate stripper gas in the AMS tandetron permits to measure heavy radionuclides with very low detection levels, allowing to perform environmental studies using these radionuclides as tracers. The use of the microbeam in the tandem accelerator allows to apply the ion beam-induced current technique to investigate the spectroscopic properties and radiation hardness of different semiconductor detectors., Also the funding made available for infrastructures through the ICTS program of the Spanish ministry of science, making use of FEDER funds from the European Union. The continuous support of CNA patrons, the University of Seville, the Junta de Andalucía and CSIC is acknowledged. Private funds, through contracts with companies and institutions, such as Curium, Alter technologies, and the andalusian health service (SAS), made possible to maintain contracts of key personnel. We acknowledge the funding of projects by the European Union, H2020-847594, H2020-654002, H2020-847552, H2020-847594 , by the Spanish ministry of science RTI2018-098117-B-C21, RTC-2017-6369-3, EQC2018-004193-P, EQC2018-004095-P, EQC2018-004166-P, PGC2018-094546-B-I00, and by the Junta de Andalucía FEDER progrem US-1261006, US-1263369, P18-RT-1900.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Continuous and pulsed fast neutron beams at the CNA HiSPANoS facility

  • Millán Callado, María de los Ángeles
  • Guerrero, C.
  • Fernández-Martínez, Begoña
  • Gómez-Camacho, Joaquín
  • Macías Martínez, Miguel Ángel
  • Quesada, José Manuel
© 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)., The characteristics of the fast neutron beams produced in the HiSPANoS facility at Centro Nacional de Aceleradores (CNA) are presented. The neutrons are generated by deuteron beams from a 3 MV tandem accelerator in either continuous (5 μA) or pulsed (2 ns width, 500 kHz and 4% duty cycle) mode. In this work, the pulsed mode was used in a time-of-flight characterization of the produced neutron beams in terms of yield, flux, energy resolution, and background. The results were then validated through their comparison with previously published data. Quasi-monoenergetic neutron beams between 2 and 6 MeV are produced by means of the H(d,n)He reaction, featuring a neutron yield of 10 n/sr/μC at the target, with an energy resolution of about 7% at 150 cm. Neutron beams with broad energy distributions are produced by deuteron irradiation of thick beryllium and lithium targets, resulting in maximum neutron energies of 10 and 20 MeV, respectively. In this case, the neutron yields are significantly higher, reaching 10 n/sr/μC. On the basis of these results, we consider that the HiSPANoS facility is now fully operational for the usage of fast neutrons by internal and external users of CNA., This work has received funding from the Euratom research and training program 2014–2018 under the grant agreement No 847594 (H2020-Euratom-ARIEL), the Marie Curie actions of the 7th Framework Program under the grant agreement No 334315 (FP7-PEOPLE-NeutANdalus), the Spanish national projects FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, and PID2021-123879OB-C21; and the FEDER Andalucía funds under the project US-1261006., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

COSMONAUT: A COmpact spectrometer for measurements of neutrons at the ASDEX upgrade tokamak

  • Nocente, M.
  • Dal Molin, A.
  • Rigamonti, Davide
  • Dalla Rosa, Marco
  • Fernández, Begoña
  • Fugazza, Simone
  • Guerrero, C.
  • Gorini, Giuseppe
  • Kazakov, Y.
  • Tardini, Giovanni
  • Tardocchi, Marco
A COmpact Spectrometer for Measurements Of Neutrons at the ASDEX Upgrade Tokamak (COSMONAUT) has been developed for spectroscopy measurements of the 2.45 MeV neutron emission from deuterium plasmas at the ASDEX Upgrade. The instrument is based on a CLYC-7 inorganic scintillator, whereby the detection of fusion neutrons occurs via their interaction with 35Cl nuclei in the detector crystal, leading to a peak in the detector response function and providing excellent neutron/gamma-ray discrimination capabilities. The diagnostics is installed along a radial line of sight and makes use of a digital system to record time resolved data for the whole duration of the discharge. Measurements in ASDEX Upgrade plasmas with neutral beam injection have been carried out and are successfully interpreted using state-of-the-art modeling codes. Next step applications of the diagnostics are in experiments aimed at generating energetic particles by ion cyclotron resonance heating schemes. In these scenarios, COSMONAUT will provide unique information on the acceleration of deuterons beyond the beam injection energy and on their confinement, for comparison with modeling., This work has been carried out within the framework of the EUROfusion Consortium, funded by the European Union via the Euratom Research and Training Program (Grant Agreement No. 101052200—EUROfusion). The views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the European Union or the European Commission. Neither the European Union nor the European Commission can be held responsible for them. This work has received funding from the Euratom research and training program 2014–2018 under Grant Agreement No. 847594 (H2020-Euratom-ARIEL)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

New measurement of 50Cr and 53Cr (n,γ) cross sections at n_TOF: a call for chromium nuclear data revision

  • Pérez-Maroto, Pablo
  • Guerrero, C.
  • Casanovas, A.
  • Fernández, B.
  • Mendoza, E.
  • Alcayne, V.
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Quesada, J. M.
  • Capote, R.
  • Aberle, O.
  • Altieri, S.
  • Amaducci, S.
  • Andrzejewski, J.
  • Babiano-Suarez, V.
  • Bacak, M.
  • Balibrea-Correa, J.
  • Beltrami, C.
  • Bennett, S.
  • Bernardes, A. P.
  • Berthoumieux, E.
  • Beyer, R.
  • Boromiza, M.
  • Bosnar, D.
  • Caamaño, M.
  • Calviño, F.
  • Calviani, M.
  • Cano-Ott, D.
  • Castelluccio, D. M.
  • Cerutti, G.
  • Chasapoglou, S.
  • Chiaveri, E.
  • Colombetti, P.
  • Colonna, N.
  • Console Camprini, P.
  • Cortés, G.
  • Cortés-Giraldo, M. A.
  • Cosentino, L.
  • Cristallo, S.
  • Dellmann, S. F.
  • Diakaki, M.
  • Di Castro, M.
  • Dietz, M,
  • Di Maria, S.
  • Dressler, R.
  • Dupont, E.
  • Durán, I.
  • Eleme, Z.
  • Fargier, S.
  • Fernández-Domínguez, B.
  • Finocchiaro, P.
  • Fiore, S.
  • Furman, V.
  • García-Infantes, F.
  • Gawlik-Ramiega, A.
  • Gervino, G.
  • Gilardoni, S.
  • González-Romero, E.
  • Gunsing, F.
  • Gustavino, C.
  • Heyse, J.
  • Hillman, W.
  • Jenkins, D. G.
  • Jericha, E.
  • Junghans, A.
  • Kadi, Y.
  • Kaperoni, K.
  • Kaur, G.
  • Kimura, A.
  • Knapová, I.
  • Kokkoris, M.
  • Kopatch, Y.
  • Krtička, M.
  • Kyritsis, N.
  • Ladarescu, I.
  • Lederer-Woods, C.
  • Lerner, G.
  • Manna, A.
  • Martínez, T.
  • Masi, A.
  • Massimi, C.
  • Mastinu, P.
  • Mastromarco, M.
  • Maugeri, E. A.
  • Mazzone, A.
  • Mengoni, A.
  • Michalopoulou, V.
  • Milazzo, P. M.
  • Mucciola, R.
  • Murtas, F.
  • Musacchio González, E.
  • Musumarra, A.
  • Negret, A.
  • Patronis, N.
  • Pavón, J. A.
  • Pellegriti, M. G.
  • Pérez de Rada Fiol, A.
  • Perkowski, J.
  • Petrone, C.
  • Pirovano, E.
  • Plaza del Olmo, J.
  • Pomp, S.
  • Porras, I.
  • Praena, J.
  • Reifarth, R.
  • Rochman, D.
  • Romanets, Y.
  • Rubbia, C.
  • Sánchez-Caballero, A.
  • Sabaté-Gilarte, M.
  • Schillebeeckx, P.
  • Schumann, D.
  • Sekhar, A.
  • Smith, A. G.
  • Sosnin, N. V.
  • Stamati, M. E.
  • Sturniolo, A.
  • Tagliente, G.
  • Tarifeño-Saldivia, A.
  • Tarrío, D.
  • Torres-Sánchez, P.
  • Urlass, S.
  • Vagena, E.
  • Valenta, S.
  • Variale, V.
  • Vaz, P.
  • Vecchio, G.
  • Vescovi, D.
  • Vlachoudis, V.
  • Vlastou, R.
  • Wallner, A.
  • Woods, P. J.
  • Wright, T.
  • Zarrella, R.
  • Žugec, P.
50Cr and 53Cr are very relevant in criticality safety benchmarks related to nuclear reactors. The discrepancies of up to 30% between the neutron capture cross section evaluations have an important effect on the kef f and k∞ in criticality benchmarks particularly sensitive to chromium. In this work, the 50,53Cr(n,γ ) cross sections are to be determined between 1 and 100 keV with an 8–10% accuracy following the requirements of the NEA High Priority Request List (HPRL) to solve the current discrepancies. We have measured these reactions by the time-of-flight technique at the EAR1 experimental area of the n_TOF facility, using an array of four C6D6 detectors with very low neutron sensitivity. The highly-enriched samples used are significantly thinner than in previous measurements, thus minimizing the multiple-scattering effects. We have produced, and analysed with the R-matrix analysis code SAMMY, capture yields featuring 33 resonances of 50Cr and 51 of 53Cr with an accuracy between 5% and 9%, hence fulfilling the requirements made by the NEA. The differential and integral cross sections have been compared to previous data and evaluations. The new measured 50,53Cr(n,γ ) cross sections provide a valuable input for upcoming evaluations, which are deemed necessary given that the results presented herein do not support the increase in both cross sections proposed in the recent INDEN evaluation., Funding for open access publishing: Universidad de Sevilla/CBUA. his measurement has received funding from the Euroatom research and training programme 2014-2018 under grant agreement No 847594 (ARIEL), and from the Spanish national projects RTI2018-098117-B-C21, PID2019-104714GB-C22, PID2021-123879 OB-C21 and PID2022-138297NB-C21. This work is also part of the PhD thesis of P. Pérez-Maroto at Universidad de Sevilla, Spain [53], funded through the FPI national Grant No PRE2019-089678. We also acknowledge the National Science Centre, Poland (Grant No. UMO-2021/41/B/ST2/00326)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Methodology for Assessing Neutron-Induced Effects on Field-Programmable Gate Array Memories

  • Vilas-Bôas, Alexis C.
  • Jiménez Sánchez, Jorge
  • Palomo, Francisco Rogelio
  • Finco, Saulo
  • Guerrero, C.
  • Fernández-Martínez, Begoña
  • Guazzelli, Marcilei A.
This work proposes a methodology to evaluate the robustness of commercial Field-Programmable Gate Arrays (FPGAs) against radiation effects induced by fast neutrons. The automated data acquisition system implemented in this study enables monitoring and characterization of neutron-induced er- rors in the devices. The results allowed us to observe consistently that irradiation with fast neutrons at CNA HiSPANoS produced errors in the FPGA, including Single Event Upsets (SEUs), which affect the implemented control logic, and Single Event Functional Interrupts (SEFIs), leading to a complete loss of data. The proposed approach provides a framework for as- sessing the susceptibility of commercial FPGAs to neutron-in- duced faults and serves as a foundation for future investigations in this field., Authors acknowledge financial and/or structural support from: FAPESP 2023/16053-8, 2022/09131-0, 2018/25225-9, 2020/04867-2, 2019/07764-1; INCT-FNA: 408419/2024-5; CNPq: 150135/2025-4, 404054/2023-4, 408800/2021-6, 301576/2022-0, 30360/2020-9. CPSAE (CTI): 314013/2025-3; Projeto CITAR. Centro Nacional de Aceleradores (CNA), CAPES:88881.690571/2022-01. Universidad de Sevilla, Proyecto PID 2021-123879OB-C21 del Ministerio de Ciencia e Innovación and EC H2020-Euratom research and training programme 2014–2018 under GA 847594 (ARIEL)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Single-event fast neutron time-of-flight spectrometry with a petawatt-laser-driven neutron source

  • Millán Callado, María de los Ángeles
  • Scheuren, S.
  • Alejo, Aarón
  • Benlliure, José
  • Beyer, R.
  • Cowan, T. E.
  • Fernández-Martínez, Begoña
  • Griesmayer, E.
  • Junghans, A. R.
  • Kohl, J.
  • Kroll, F.
  • Metzkes-Ng, J.
  • Prencipe, I.
  • Quesada, José Manuel
  • Rehwald, M.
  • Rödel, C.
  • Rodríguez-González, M. Teresa
  • Schramm, U.
  • Roth, M.
  • Štefaníková, R.
  • Urlass, S.
  • Weiss, C.
  • Zeil, K.
  • Ziegler, T.
  • Guerrero, C.
Laser-driven neutron sources (LDNSs) offer unique advantages for fundamental physics and applications: ultrashort pulses providing superior energy resolution, high instantaneous flux, and a reduced footprint. While single-event neutron spectroscopy has been demonstrated with epithermal neutrons, its application for fast neutrons is more challenging and remains unproven. This demands stable multi-shot operation and detectors resilient to this particularly extreme environment. Here, a proof-of-concept experiment at the DRACO PW laser is presented. This setup stably produced ~ 108 fast neutrons per shot sustained over more than 200 shots at a shot-per-minute rate. Neutron time-of-flight measurements with a diamond detector at only 150 cm from the source resolved individual neutron-induced reactions at a rate consistent with simulations informed by real-time diagnostics of accompanying gammas, ions, and electrons. Combined with the recent advances in the field, this work establishes LDNSs as a promising, scalable platform for future fast neutron-induced reaction studies, particularly those involving short-lived isotopes., The authors acknowledge financial support by: - The Spanish Ministry of Economy and Competitiveness (RYC-2014-15271, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PID2023-152894OA-I00 and RYC2021-032654I projects); - MAMC has received funding from the EC Euratom research and training program 2014-2018 under grant agreement No 847594 (ARIEL) and the EC PEOPLE Marie-Curie Action program 2007-2013 under grant agreement No 334315 (NeutAndalus); - Xunta de Galicia (grant ED431F2023/21, CIGUS Network of Research Centers); - “La Caixa” Foundation (ID 100010434), fellowship code LCF/BQ/PI20/11760027; - María de Maeztu grant CEX2023-001318-M funded by MICIU/AEI/10.13039/501100011033S; - The project was supported by Hi-Acts, an innovation platform under the grant of the Helmholtz Association HGF and funded by BMFTR under the project PLANET 13N16951- SSch acknowledges support from Trumpf SE + Co. KG; - CR acknowledges support from the LOEWE excellence program of the state of Hesse - This work was supported by CIVIDEC Instrumentation., Open Access funding enabled and organized by Projekt DEAL., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Measurement of the 235U fission cross section relative to the standard 10B(n, a) reaction at the CERN n_TOF facility: Results for En< 2 eV

  • Michalopoulou, Veatriki
  • Diakaki, Maria
  • Kyritsis, Nikolaos
  • Kokkoris, Michael
  • Vlastou, Roza
  • Babiano Suárez, Víctor
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
The neutron induced fission of 235U is a very important reaction for nuclear technology applications and for the design of future systems to produce clean and safe energy. In addition, it is used as a reference reaction for neutron cross-section measurements, thus, its cross section is needed with a high accuracy over a wide energy range. In this work, the measurement for the 235U(n,f) reaction was carried out at the n_TOF facility located at CERN, at experimental area EAR-2. The standard 10B(n, ) reaction was used as reference, while a setup based on the gaseous Micromegas detectors was implemented for the detection of the fission fragments and and 7Li-particles of the two reactions, respectively. In order to determine the thickness of the 10B sample NRA measurements were carried out at the National Center for Scientific Research “Demokritos”., This project is carried out within the framework of the National Recovery and Resilience Plan Greece 2.0, funded by the European Union–NextGenerationEU (Implementation body: HFRI) This project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No 847594 (ARIEL)., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Measurement of the 235U fission cross section relative to the standard 10B(n, a) reaction at the CERN n_TOF facility: Results for En< 2 eV

  • Michalopoulou, Veatriki
  • Diakaki, Maria
  • Kyritsis, Nikolaos
  • Kokkoris, Michael
  • Vlastou, Roza
  • Babiano Suárez, Víctor
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
The neutron induced fission of 235U is a very important reaction for nuclear technology applications and for the design of future systems to produce clean and safe energy. In addition, it is used as a reference reaction for neutron cross-section measurements, thus, its cross section is needed with a high accuracy over a wide energy range. In this work, the measurement for the 235U(n,f) reaction was carried out at the n_TOF facility located at CERN, at experimental area EAR-2. The standard 10B(n, ) reaction was used as reference, while a setup based on the gaseous Micromegas detectors was implemented for the detection of the fission fragments and and 7Li-particles of the two reactions, respectively. In order to determine the thickness of the 10B sample NRA measurements were carried out at the National Center for Scientific Research “Demokritos”., This project is carried out within the framework of the National Recovery and Resilience Plan Greece 2.0, funded by the European Union–NextGenerationEU (Implementation body: HFRI) This project has received funding from the Euratom research and training programme 2014–2018 under grant agreement No 847594 (ARIEL)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed, Postprint (published version)
Archivo Digital UPM
Publicación Tesis doctoral (DoctoralThesis)

Application of OpenCL to FPGA-based systems in EPICS. Contribution to the standardization of advanced instrumentation systems for Big Science experiments