Hybrid compton-PET imaging for ion-range verification: a preclinical study for proton, helium, and carbon therapy at HIT

  • Balibrea-Correa, Javier
  • Lerendegui-Marco, Jorge
  • Ladarescu, Ion
  • Guerrero, Carlos
  • Rodríguez-González, Teresa
  • Jiménez-Ramos, Maria del Carmen
  • Quesada, Jose Manuel
  • Bauer, Julia
  • Brons, Stephan
  • Domingo-Pardo, César
  • Morell-Ortega, Sergio|||0009-0001-7639-2915
[EN] Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and researched methodologies, both of them with their own advantages and challenges. Thus far, both of them have been explored for ion-range verification in an independent way. However, the simultaneous combination of PET and PGI within the same imaging framework may open-up the possibility to exploit more efficiently all radiative emissions excited in the tissue by the ion beam. Here, we report on the first preclinical implementation of an hybrid PET-PGI imaging system, hereby exploring its performance over several ion beam species (H, He and C), energies (55¿275 MeV) and intensities ( - ions/spot), which are representative of clinical conditions. The measurements were carried out using the pencil-beam scanning technique at the synchrotron accelerator of the heavy ion therapy center in Heidelberg utilizing an array of four Compton cameras in a twofold front-to-front configuration. The results demonstrate that the hybrid PET-PGI technique can be well suited for relatively low energies (55¿155 MeV) and beams of protons. On the other hand, for heavier beams of helium and carbon ions at higher energies (155¿275 MeV), range monitoring becomes more challenging owing to large backgrounds from additional nuclear processes. The experimental results are well understood on the basis of realistic Monte Carlo calculations, which show a satisfactory agreement with the measured data. This work can guide further upgrades of the hybrid PET-PGI system toward a clinical implementation of this innovative technique., This work derives from fundamental research carried out with funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation program (ERC Consolidator Grant project HYMNS, with grant agreement No. 681740) and part of this work has been funded under ERC Proof-of-Concept Grant GNVISION (Grant Agreement 101113330). The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PDC2021-121536-C21, PID2019-104714GB-C21 and RTI2018-098117-B-C21. We acknowledge support from the Severo Ochoa Grant CEX2023-001292-S funded by MCIU/AEI. T. Rodriguez-Gonzalez acknowledges the Spanish FPI predoctoral grant. J. Balibrea-Correa is supported by grant ICJ220-045122-I and J. Lerendegui-Marco is supported by grant FJC2020-044688-I funded by MCIN/AEI/10.13039/501100011033 and CIAPOS/2022/020 funded by MICIN/AEI and Generalitat Valenciana. Ion Ladarescu was funded by the R&D grant PDC2022-133382-I00, funded by the Spanish Ministry of Science (MCIN/AEI/10.13039/501100011033). M.C. Jiménez-Ramos acknowledges the support to this work through a VI PPIT-US contract. We would like to thank the crew at the Electronics Laboratory of IFIC, in particular Manuel Lopez Redondo and Jorge Nácher Arándiga for their excellent and efficient work prototyping and manufacturing customized PCBs for this work.
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Ambient dosimetry in pulsed neutron fields with LINrem detectors

  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Blas del Hoyo, Alfredo de|||0000-0002-0868-9514
  • Brusasco, Benedetta|||0009-0004-6933-1585
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cives Fernández, Ana M.
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • García Sánchez, Roger|||0000-0001-7435-9436
  • Molina Palacios, Francisco
  • Mont i Geli, Nil|||0000-0003-4249-7281
  • Pallàs i Solís, Max|||0000-0001-6137-0812
  • Pávez Mercado, Christian
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fields generated by fusion plasmas and high-intensity pulsed lasers are presented. Additionally, prospects and future plans for the LINrem project are outlined., This work has been supported by Agència de Gestió d’Ajuts Universitaris i de Recerca (AGAUR), Spain grant 2018-LLAV-00039. Grant ACM2019-014 Universidad Politécnica de Catalunya-FEDER, Spain. Grants from Ministerio de Ciencia e Innovacion, Spain PID2019-104714GBC21, PID2019-104714GB-C22 and PDC2021-121536-C21/2. F. M. acknowledges support from ANID-FONDECYT, Chile project N◦ 1221364. C. P. acknowledges support from ANID-Fondecyt, Chile project N◦ 1211885. The authors would like to express their gratitude to the technical and scientific staff at CLPU for their support during the experimental activities. Additionally, we extend our thanks to the reviewers for their time and effort in reviewing our manuscript. We sincerely appreciate their valuable comments and suggestions, which have significantly improved the quality of our work., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Ambient dosimetry in pulsed neutron fields with LINrem detectors

  • Tarifeño Saldivia, Ariel Esteban
  • Calviño Tavares, Francisco
  • Blas del Hoyo, Alfredo de
  • Brusasco, Benedetta
  • Casanovas Hoste, Adrià
  • Cives Fernández, Ana M.
  • Cortés Rossell, Guillem Pere
  • García Sánchez, Roger
  • Molina Palacios, Francisco
  • Mont i Geli, Nil
  • Pallàs i Solís, Max
  • Pávez Mercado, Christian
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fields generated by fusion plasmas and high-intensity pulsed lasers are presented. Additionally, prospects and future plans for the LINrem project are outlined., This work has been supported by Agència de Gestió d’Ajuts Universitaris i de Recerca (AGAUR), Spain grant 2018-LLAV-00039. Grant ACM2019-014 Universidad Politécnica de Catalunya-FEDER, Spain. Grants from Ministerio de Ciencia e Innovacion, Spain PID2019-104714GBC21, PID2019-104714GB-C22 and PDC2021-121536-C21/2. F. M. acknowledges support from ANID-FONDECYT, Chile project N◦ 1221364. C. P. acknowledges support from ANID-Fondecyt, Chile project N◦ 1211885. The authors would like to express their gratitude to the technical and scientific staff at CLPU for their support during the experimental activities. Additionally, we extend our thanks to the reviewers for their time and effort in reviewing our manuscript. We sincerely appreciate their valuable comments and suggestions, which have significantly improved the quality of our work., Peer Reviewed, Postprint (published version)