Pasar al contenido principal

Artificial Intelligence for PET signal processing

JDC2023-051754-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Formación
Convocatoria Juan de la Cierva
Año convocatoria 2023
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analytical positron range model for PET with cross-code Monte Carlo benchmarking

  • Paneque-Yunta, Robert J.
  • Encina-Baranda, Nerea
  • Carter, Lukas M.
  • Galve, Pablo
  • Ibáñez, Paula
  • Abushab, Khaled M.
  • Udías, José M Udías
  • Herraiz, Joaquín L.
22 páginas, 8 figuras, 5 tablas, Introduction. The positron range (PR) effect is a significant factor limiting spatial resolution in positron emission tomography (PET), particularly for high-resolution systems and non-standard isotopes. Objective. This study introduces a novel analytical model to accurately and rapidly describe PR distributions (PRd) for various PET radioisotopes to better include its effect in PET reconstruction algorithms. Approach. The proposed model explicitly incorporates the Coulomb repulsion effect, the multi-branch nature of certain β+ emitters, and the scaling of PR with electronic density. To minimise bias, we used a histogram-free statistical method to derive the cumulative PRd from Monte Carlo (MC) simulated annihilation datasets, avoiding arbitrary histogram binning. A comparative analysis of PR estimates was conducted across three major MC radiation transport algorithm packages: PENELOPE (via PenEasy/PeneloPET), GEANT4 (via GATE), and EGS5 (via PHITS), revealing notable discrepancies between codes, versions, and input configurations, especially at short distances from the source. Main results. The new analytical model demonstrated an excellent reproduction of the simulated data for isotopes including 11C , 13N , 15O , 18F , 64Cu , 68Ga , 82Rb and 124I , achieving in general coefficients of determination (R2) greater than 0.995 and mean absolute percentage errors ≲20%. Compared to previous methods, our model provides a more accurate description of PRd at low distances and offers improved R2 values. Significance. This work provides a robust framework for generating accurate annihilation point spread function kernels, facilitating improved PR correction in quantitative Nuclear Medical Imaging and supporting research with diverse radioisotopes., We acknowledge support from the following grants: FASCINA (PID2021-126998OB-I00), Prototwin Project (TED2021-349130592B-I00), INVENTOR (PID2022-137114OA-I00) and 3PET (PDC2022-133057-I00), funded by the Spanish Ministry of Science, Innovation and Universities (MCIU) through AEI/10.13039/501100011033 and the European Union’s NextGenerationEU/PRT programme and the Spanish Government. P. G. also acknowledges support from the grant JDC2023-051754-I, funded by MCIU/AEI/10.13039/501100011033 and ESF+., Peer reviewed