Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Mapping intratumoral heterogeneity through PET-derived washout and deep learning after proton therapy

  • Cabrales, Pablo
  • Izquierdo-García, David
  • V. Onecha, Víctor
  • Pérez Liva, Mailyn
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • López Herraiz, Joaquín
The distribution of produced isotopes during proton therapy can be imaged with Positron Emission Tomography (PET) to verify dose delivery. However, biological washout, driven by tissue-dependent processes such as perfusion and cellular metabolism, reduces PET signal-to-noise ratio (SNR) and limits quantitative analysis. In this work, we propose an uncertainty-aware deep learning framework to improve the estimation of washout parameters in post-proton therapy PET, not only enabling accurate correction for washout effects, but also mapping intratumoral heterogeneity as a surrogate marker of tumor status and treatment response. We trained the models on Monte Carlo-simulated data from eight head-and-neck cancer patients, and tested them on four additional head-and-neck and one liver patient. Each patient was represented by 75 digital twins with distinct tumoral washout dynamics and imaged 15 min after treatment, when slow washout components dominate. We also introduced washed-out maps, quantifying the contribution of medium and fast washout components to the loss in activity between the end of treatment and the start of PET imaging. Trained models significantly improved resolution and accuracy, reducing average absolute errors by 60% and 28% for washout rate and washed-out maps, respectively. For intratumoral regions as small as 5.1 mL, errors predominantly fell below thresholds for differentiating vascular status, and the models generalized across anatomical areas and acquisition delays. This study shows the potential of deep learning in post-proton therapy PET to non-invasively map washout kinetics and reveal intratumoral heterogeneity, supporting dose verification, tumor characterization, and treatment personalization. The framework is available at https://github.com/pcabrales/ppw.git .
Docta Complutense
Publicación Artículo científico (JournalArticle)

Stress-induced takotsubo syndrome: dynamic changes in regional cerebral metabolism revealed by quantitative PET imaging

  • Ariza Carrasco, Alejandro
  • Yoganathan, Thulaciga
  • Leciñana, María Alonso de
  • Viel, Thomas
  • Mikail, Nidaa
  • López Herraiz, Joaquín
  • Udías Moinelo, José Manuel
  • Ibáñez García, Paula Beatriz
  • Tavitian, Bertrand
  • Pérez-Liva, Mailyn
Stress significantly contributes to cardiovascular diseases such as Takotsubo syndrome (TTS), which mimics an acute coronary syndrome without coronary obstruction. TTS is triggered by surgery, trauma, and emergency treatments in patients, and is reproduced in animal models by a catecholamine surge that impacts cardiac sympathetic innervation. The action of catecholamines on energy metabolism is well documented in the heart, less so in the brain. We investigated the effects of acute catecholaminergic stress on regional cerebral glucose metabolism and interregional metabolic organization in a TTS rat model using FDG-PET and quantitative two- tissue compartment modeling. Adult female rats received a single intraperitoneal injection of isoprenaline (ISO) (50 mg/kg). Dynamic FDG-PET imaging was performed at baseline, 2 hours (acute phase), and 7 days (recovery phase) post-injection. Kinetic parameters, namely glucose inflow (K1) and glucose phosphorylation (k3), were quantified in 58 brain regions. Interregional metabolic coordination, defined as statistically significant linear correlations between regional kinetic parameters, was assessed across functional brain areas. During the acute phase, the catecholaminergic surge induced widespread reductions in glucose inflow and regional decreases in phosphorylation, particularly in the limbic and sensorimotor areas. During the recovery phase, most regions remained below baseline. Metabolic coordination increased for glucose inflow in both phases but declined for phosphorylation, especially during recovery, indicating a disruption of metabolic synchronization. Persistent changes in brain metabolism imply that mid-to-long-term changes in regional cerebral metabolism may contribute to long-term TTS consequences.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Zinc-Doped Iron Oxide Nanoparticles as a Proton-Activatable Agent for Dose Range Verification in Proton Therapy

  • Ibáñez-Moragues, Marta
  • Fernández-Barahona, Irene
  • Santacruz, Rocío
  • Oteo, Marta
  • Luján-Rodríguez, Víctor M.
  • Muñoz-Hernando, María
  • Magro, Natalia
  • Lagares, Juan I.
  • Romero, Eduardo
  • España, Samuel
  • Espinosa-Rodríguez, Andrea
  • García-Díez, Miguel
  • Martínez-Nouvilas, Víctor
  • Sánchez-Tembleque, Víctor
  • Udías, José Manuel
  • Valladolid-Onecha, Víctor
  • Martín-Rey, Miguel Ángel
  • Almeida-Cordón, Edilia I.
  • Viñals i Onsès, Sílvia
  • Pérez, José Manuel
  • Fraile, Luis Mario
  • Herranz, Fernando
  • Morcillo, Miguel Ángel
Proton therapy allows the treatment of specific areas and avoids the surrounding tissues. However, this technique has uncertainties in terms of the distal dose fall-off. A promising approach to studying the proton range is the use of nanoparticles as proton-activatable agents that produce detectable signals. For this, we developed an iron oxide nanoparticle doped with Zn (IONP@Zn-cit) with a hydrodynamic size of 10 nm and stability in serum. Cytotoxicity, defined as half of the surveillance, was 100 μg Zn/mL in the U251 cell line. The effect on clonogenic cell death was tested after X-ray irradiation, which suggested a radioprotective effect of these nanoparticles at low concentrations (1–10 μg Zn/mL). To evaluate the production of positron emitters and prompt-gamma signals, IONP@Zn-cit was irradiated with protons, obtaining prompt-gamma signals at the lowest measured concentration (10 mg Zn/mL). Finally, 67Ga-IONP@Zn-cit showed accumulation in the liver and spleen and an accumulation in the tumor tissue of 0.95% ID/g in a mouse model of U251 cells. These results suggest the possibility of using Zn nanoparticles as proton-activatable agents to verify the range by prompt gamma detection and face the challenges of prompt gamma detection in a specific biological situation, opening different avenues to go forward in this field., This research was supported by projects B2017/BMD-3888 PRONTO-CM and S2022/BMD-7434 ASAP-CM, both funded by Comunidad de Madrid, and projects PID2019-104558RB-I00 and TED2021-130592B-I00, both funded by MCIN/ AEI/10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Dual photoacoustic/ultrasound technologies for preclinical research: current status and future trends

  • Pérez-Liva, Mailyn
  • Alonso de Leciñana, María
  • Gutiérrez-Fernández, María
  • Camacho Sosa-Días, Jorge
  • Fernández Cruza, Jorge
  • Rodríguez-Pardo, Jorge
  • García-Suárez, Iván
  • Laso-García, Fernando
  • L. Herraiz, Joaquín
  • Elvira Segura, Luis
30 páginas, 6 figuras, 2 tablas., Photoacoustic (PA) imaging, by integrating optical and ultrasound (US) modalities, combines high spatial resolution with deep tissue penetration, making it a transformative tool in biomedical research. This review presents a comprehensive analysis of the current status of dual PA/US imaging technologies, emphasising their applications in preclinical research. It details advancements in light excitation strategies, including tomographic and microscopic modalities, innovations in pulsed laser and alternative light sources, and US instrumentation. The review further explores preclinical methodologies, encompassing dedicated instrumentation, signal processing, and data analysis techniques essential for PA/US systems. Key applications discussed include the visualisation of blood vessels, micro-circulation, and tissue perfusion; diagnosis and monitoring of inflammation; evaluation of infections, atherosclerosis, burn injuries, healing, and scar formation; assessment of liver and renal diseases; monitoring of epilepsy and neurodegenerative conditions; studies on brain disorders and preeclampsia; cell therapy monitoring; and tumour detection, staging, and recurrence monitoring. Challenges related to imaging depth, resolution, cost, and the translation of contrast agents to clinical practice are analysed, alongside advancements in high-speed acquisition, artificial intelligence-driven reconstruction, and innovative light-delivery methods. While clinical translation remains complex, this review underscores the crucial role of preclinical studies in unravelling fundamental biomedical questions and assessing novel imaging strategies. Ultimately, this review delves into the future trends of dual PA/US imaging, highlighting its potential to bridge preclinical discoveries with clinical applications and drive advances in diagnostics, therapeutic monitoring, and personalised medicine., The work of Mailyn Pérez-Liva was supported in part by the Program Ramón y Cajal under Grant RYC2021-032739-I, MCIN/AEI/10.13039/501100011033, by the European Union ‘NextGenerationEU’/PRTR and by INVENTOR PID2022-137114OA-I00. Joaquin L Herraiz acknowledges support from TED2021-130592B-I00 funded by MCIN/AEI/10.13039/501100011033 and TARTAGLIA MIA.2021.M02.0005, funded by the Spanish Ministry of EADT, with funds nextGenerationEU/PRTR. Luis Elvira was supported by PID2022-138013OB-I00/ AEI/10.13039/501100011033/FEDER. María Gutiérrez-Fernández was supported by the Program Miguel Servet under Grant CPII20/00002, Carlos III Health Institute (ISCIII). Fernando Laso-García was supported by the Spanish Ministry of Health- (ISCIII) under Grant FI18/00026., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Real-time dose reconstruction in proton therapy from in-beam PET measurements

  • Onecha, V.V.
  • Espinosa-Rodriguez, A.
  • Soneira-Landín, C.
  • Arias-Valcayo, F.
  • Gaitán-Dominguez, S.
  • Martinez-Nouvilas, V.
  • García-Díez, M.
  • Ibáñez, P.
  • España, Samuel
  • Sanchez-Parcerisa, D.
  • Cerrón-Campoo, F.
  • Vera-Sánchez, J.A.
  • Mazal, A.
  • Udias, J.M.
  • Fraile, L.M.
18 páginas, 11 figuras, 1 tabla., Objective. Clinical implementation of in-beam positron emission tomography (PET) monitoring in proton therapy (PT) requires the integration of an online fast and reliable dose calculation engine. This manuscript reports on the achievement of real-time reconstruction of 3D dose and activity maps with proton range verification from experimental in-beam PET measurements. Approach. Several cylindrical homogeneous PMMA phantoms were irradiated with a monoenergetic 70 MeV proton beam in a clinical facility. Additionally, PMMA range-shifting foils of varying thicknesses were placed at the proximal surface of the phantom to investigate range shift prediction capabilities. PET activity was measured using a state-of-the-art in-house developed six-module PET scanner equipped with online PET reconstruction capabilities. For real-time dose estimation, we integrated this system with an in-beam dose estimation algorithm, which combines a graphical processing unit-based 3D reconstruction algorithm with a dictionary-based software, capable of estimating deposited doses from the 3D PET activity images. The range shift prediction performance has been quantitatively studied in terms of the minimum dose to be delivered and the maximum acquisition time. Main results. With this framework, 3D dose maps were accurately reconstructed and displayed with a delay as short as one second. For a dose fraction of 8.4 Gy at the Bragg peak maximum, range shifts as small as 1 mm could be detected. The quantitative analysis shows that accumulating 20 s of statistics from the start of the irradiation, doses down to 1 Gy could be estimated online with total uncertainties smaller than 2 mm. Significance. The hardware and software combination employed in this work can deliver dose maps and accurately predict range shifts after short acquisition times and small doses, suggesting that real-time monitoring and dose reconstruction during PT are within reach. Future work will focus on testing the methodology in more complex clinical scenarios and on upgrading the PET prototype for increased sensitivity, This work was funded by Comunidad de Madrid, Spain under Projects PRONTO-CM (B2017/BMD-3888) and ASAP-CM (S2022/BMD7434). We acknowledge support by UCM under project pFLASH (PR27/21-014); Spanish MCIN/AEI/10.13039/501100011033 under Grants RADFLAP (PID2021-124094OA-I00), FLASHonCHIP (PLEC2022-009256), PROTOTWIN (TED2021-130592B-I00), mPET (PID2021-126998OB-I00) and INVENTOR (PID2022-137114OA-I00); European Union as part of the European Innovation Council's Pathfinder Open Programme: RETIMAGER, 101099096. The authors acknowledge the support from The Centro de protonterapia Quirónsalud, for the beam time, and its technical staff for their contribution to the operation of the accelerator. This contribution is for the Moncloa Campus of International Excellence, "Nuclear Physics Group-UCM," Ref. 910059. Part of the calculations for this work were performed on the "Computing Cluster for Physical Techniques," funded partially by UCM and partially by EU Regional Funds., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fast-Timing Detector through Redshifted Cherenkov Radiation

  • Fernández-Borreguero, C.
  • Fraile, L. M.
  • Udias, J.M
  • España, Samuel
10th Conference on PET, SPECT, and MR Multimodal Technologies, Total Body and Fast Timing in Medical Imaging, 20-23 May, 2024, Isola d'Elba, Italy. 10 figuras, 2 tablas., This study explores advancements in Time-of-Flight PET (TOF-PET) technology, specifically focusing on Redshifted Cherenkov Radiators (RCR) to enhance time resolution in radiation detectors. TOF-PET utilizes radiotracers labeled with positron-emitting radionuclides to track biological targets, aiding in diagnosis, treatment planning, and therapeutic monitoring. Recent hardware, radiotracer, and image analysis advancements have expanded TOF-PET's clinical applications. This study concentrates on the development of RCRs to further improve TOF-PET capabilities. Evaluation of solvents¿ODE, CHCl3, DMSO¿reveals ODE's superior UV transparency. The addition of POPOP dopant in ODE significantly enhances the detection of Cherenkov photons, demonstrating the potential of RCR. Time-correlated single photon counting (TCSPC) analysis indicates that RCR detectors offer competitive time responses compared to pure Cherenkov detectors. Coincidence measurements with LYSO detectors demonstrate favorable Coincidence Time Resolutions (CTR) for RCR detectors. These findings offer insights into the optimization of RCRs, suggesting their role in advancing TOF-PET imaging for enhanced diagnostic accuracy and therapeutic monitoring., This work was funded by the Universidad Complutense de Madrid under Project PR27/21-009 and by MICIN/AEI/https://doi.org/10.13039/501100011033 under projects TED2021-129933B-C21 and TED2021- 130592B-I00. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020- 001041-S funded by MICIN/AEI/https://doi.org/10.13039/501100011033)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Stress-induced takotsubo syndrome: dynamic changes in regional cerebral metabolism revealed by quantitative PET imaging

  • Ariza-Carrasco, Alejandro
  • Yoganathan, Thulaciga
  • Alonso de Leciñana, María
  • Viel, Thomas
  • Mikail, Nidaa
  • Herraiz, Joaquin L.
  • Udias, Jose M.
  • Ibáñez, Paula
  • Tavitian, Bertrand
  • Pérez-Liva, Mailyn
10 páginas, 3 figuras, 1 tabla, Stress significantly contributes to cardiovascular diseases such as Takotsubo syndrome (TTS), which mimics an acute coronary syndrome without coronary obstruction. TTS is triggered by surgery, trauma, and emergency treatments in patients, and is reproduced in animal models by a catecholamine surge that impacts cardiac sympathetic innervation. The action of catecholamines on energy metabolism is well documented in the heart, less so in the brain. We investigated the effects of acute catecholaminergic stress on regional cerebral glucose metabolism and interregional metabolic organization in a TTS rat model using FDG-PET and quantitative two-tissue compartment modeling. Adult female rats received a single intraperitoneal injection of isoprenaline (ISO) (50 mg/kg). Dynamic FDG-PET imaging was performed at baseline, 2 hours (acute phase), and 7 days (recovery phase) post-injection. Kinetic parameters, namely glucose inflow (K1) and glucose phosphorylation (k3), were quantified in 58 brain regions. Interregional metabolic coordination, defined as statistically significant linear correlations between regional kinetic parameters, was assessed across functional brain areas. During the acute phase, the catecholaminergic surge induced widespread reductions in glucose inflow and regional decreases in phosphorylation, particularly in the limbic and sensorimotor areas. During the recovery phase, most regions remained below baseline. Metabolic coordination increased for glucose inflow in both phases but declined for phosphorylation, especially during recovery, indicating a disruption of metabolic synchronization. Persistent changes in brain metabolism imply that mid-to-long-term changes in regional cerebral metabolism may contribute to long-term TTS consequences., MP-L acknowledges support from the Programme Ram´on y Cajal RYC2021-032739-I, funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR". JLH acknowl- edges support from grants FASCINA (PID2021-126998OB-I00/), 3PET (PDC2022-133057-I00), Prototwin Project (TED2021-130592B-I00) from the Spanish Ministry of Science and Innovation (MCIN) AEI/ 10.13039/501100011033/Uni´on Europea Next GenerationEU/PRTR, and “Tecnologías Avanzadas para la Exploraci´on del Universo y sus Componentes” (PR47/21 TAU-CM TAU-PRTR), funded by EU Resilient and NextGeneration funds. This work has been funded with €1.026 million by the Comunidad de Madrid through the LUNABRAIN-CM R&D activities program (TEC-2024/TEC-43), granted by Order 5696/2024, and has also received funding from the Cancer Research for Personalized Medicine – CARPEM project (Site de Recherche Int´egr´e sur le Cancer SIRIC), from the Plan Cancer Physicancer [grant number C16025KS], and from the R´egion Ile-de-France SESAME funds. This work was sup- ported by Knowledge Generation Projects 2022 Type A Oriented Research, Government of Spain PID2022-137114OA-I00. In vivo imag- ing was performed at the Life Imaging Facility of Universit´e Paris Cit´e (Plateforme Imageries du Vivant - PIV), supported by France Life Im- aging [grant number ANR-11-INBS-0006] and Infrastructures Biologie- Sant´e (IBiSa). BT, MP-L, PIG, JLH and JMU acknowledge support from the European Union as part of the European Innovation Council’s Pathfinder Open Programme: RETIMAGER, 101099096., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Mapping intratumoral heterogeneity through PET-derived washout and deep learning after proton therapy

  • Cabrales, Pablo
  • Izaquierdo-García, David
  • Onechea, Víctor V.
  • Pérez-Liva, Mailyn
  • Fraile, Luis Mario
  • Udías, José Manuel
  • Herráiz, Joaquín L.
13 páginas, 7 figuras, 4 tablas, The distribution of produced isotopes during proton therapy can be imaged with Positron Emission Tomography (PET) to verify dose delivery. However, biological washout, driven by tissue-dependent processes such as per fusion and cellular metabolism, reduces PET signal-to-noise ratio (SNR) and limits quantitative analysis. In this work, we propose an uncertainty-aware deep learning framework to improve the estimation of washout param eters in post-proton therapy PET, not only enabling accurate correction for washout effects, but also mapping intratumoral heterogeneity as a surrogate marker of tumor status and treatment response. We trained the models on Monte Carlo-simulated data from eight head-and-neck cancer patients, and tested them on four additional head-and-neck and one liver patient. Each patient was represented by 75 digital twins with distinct tumoral washout dynamics and imaged 15 min after treatment, when slow washout components dominate. We also in troduced washed-out maps, quantifying the contribution of medium and fast washout components to the loss in activity between the end of treatment and the start of PET imaging. Trained models significantly improved resolution and accuracy, reducing average absolute errors by 60% and 28% for washout rate and washed-out maps, respectively. For intratumoral regions as small as 5.1 mL, errors predominantly fell below thresholds for differentiating vascular status, and the models generalized across anatomical areas and acquisition delays. This tudy shows the potential of deep learning in post-proton therapy PET to non-invasively map washout kinet ics and reveal intratumoral heterogeneity, supporting dose verification, tumor characterization, and treatment personalization. The framework is available at https://github.com/pcabrales/ppw.git., This work was supported by Spanish MCIN/AEI/10.13039/ 501100011033 and the European Union NextGenerationEU/PRTR un der grants TED2021-130592B-I00 PROTOTWIN, PID2021-126998OB- I00 FASCINA, and PDC2022-133057-I00 3PET; by Comunidad de Madrid (Spain) under projects ASAP-CM P2022/BMD-7434 and TAU- CM PR47/21 (PRTR), and by Grupo de Física Nuclear (910059) at Universidad Complutense de Madrid. Additionally, Pablo Cabrales acknowledges support from the Complutense University Predoctoral Fellowship (CT15-23), funded by the Universidad Complutense de Madrid and Banco Santander, as well as from the Ayuda para estancias breves fellowship (EB33/24), funded by the Universidad Complutense de Madrid. M.Pérez-Liva was supported by the Program Ramón y Cajal RYC2021-032739-I, MCIN/AEI/10.13039/501100011033, by the European Union NextGenerationEU/PRTR, by INVENTOR PID2022- 137114OA-I00, and by LUNABRAIN (PR37/24 TEC-2024/TEC-43), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Measurement of 27Al(𝛼, 𝑛) thick-target yields by activation and 27Al(𝛼, 𝑛𝛾) reaction prompt 𝛾 rays

  • Alonso-Sañudo, Odette
  • Fraile, Luis M.
  • Briz, José Antonio
  • Agramunt, Jorge
  • Benito, J.
  • García Borge, María José
  • Caballero, M.
  • Cano Ott, Daniel
  • Cortés, Guillem
  • Espinosa-Rodríguez, A.
  • Fernández-Martínez, Begoña
  • García, Gastón
  • García Távora, Vicente
  • Guerrero, C.
  • Llanes, J.
  • Llanos-Expósito, M.
  • Martínez, T.
  • Mont-Geli, Nil
  • Murias, J. R.
  • Nácher, Enrique
  • Nakbi, A.
  • Nouvillas, V. M.
  • Onecha, V. V.
  • Pallás, Max
  • Perea, Ángel
  • Pérez de Rada, A.
  • Sánchez-Prieto, J.
  • Sánchez-Tembleque, V.
  • Taín, José Luis
  • Tarifeño-Saldivia, A.
  • Tengblad, Olof
  • Udías, J. M.
  • Viñals, S.
This work presents a study of the 27Al(𝛼, n) reaction over an extended energy range (3.5–15 MeV) relative to previous datasets, performed at the Centro de Micro-Análisis de Materiales in Madrid. Thick-target yields were obtained from activation by the online measurement of the decay of the 30P reaction product, using the recently developed Gamma-detection Array for Reaction Yield measurements. The results show good agreement with existing data and confirm the newest thick-target yields at low energies. Direct 27Al(𝛼, 𝑛𝛾) 30P 𝛾-yields were measured in order to address (𝛼, n) branches to excited states in 30P. The angular dependence of the emitted prompt 𝛾 rays was investigated, revealing significant differences as a function of angle with respect to the beam direction. The results provide benchmark data for future (𝛼, n) yield studies using online activation measurements and prompt 𝛾-ray detection., This work was funded by the Spanish MCIN/AEI/501100011033 under grants TED2021-130592B-I00 PROTOTWIN and PID2021-126998OB-I00. We acknowledge the support by the HISTARS CERN-MRR project funded by the Spanish MCIN and the European Union NextGenerationEU RRF. The authors also acknowledge the support from The Centro de Microanálisis de Materiales (CMAM) – Universidad Autónoma de Madrid , for the beam time, and its technical staff for their contribution to the operation of the accelerator. This is a contribution for the Moncloa Campus of International Excellence, “Grupo de Física Nuclear-UCM”, Ref. [910059]., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

Measurement of 27Al (α,n) thick-target yields by activation and 27Al (α,nγ) reaction prompt γ rays

  • Alonso-Sañudo, O.
  • Fraile Prieto, Luis Mario
  • Briz Monago, José Antonio
  • Illana Sisón, Andrés
  • Benito García, Jaime
  • Espinosa Rodríguez, Andrea
  • Llanos Expósito, Marcos
  • Rodríguez Murias, Javier
  • Nouvillas, V. M.
  • Valladolid Onecha, Víctor
  • Sánchez Tembleque Verbo, Víctor
  • Udías Moinelo, José Manuel
  • Viñals, S.
This work presents a study of the 27Al(α, n) reaction over an extended energy range (3.5–15 MeV) relative to previous datasets, performed at the Centro de Micro-Análisis de Materiales in Madrid. Thick-target yields were obtained from activation by the online measurement of the decay of the 30P reaction product, using the recently developed Gamma-detection Array for Reaction Yield measurements. The results show good agreement with existing data and confirm the newest thick-target yields at low energies. Direct 27Al(α,nγ)30P γ-yields were measured in order to address (α, n) branches to excited states in 30P. The angular dependence of the emitted prompt γ rays was investigated, revealing significant differences as a function of angle with respect to the beam direction. The results provide benchmark data for future (α, n) yield studies using online activation measurements and prompt γ-ray detection.
Docta Complutense
Publicación Artículo científico (JournalArticle)

MLTiming: pairwise-constrained learning for improving timing resolution in TOF-PET

  • Avellaneda, José A.
  • Sánchez Tembleque Verbo, Víctor
  • Rodríguez, Miriam Caballero
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • López Herraiz, Joaquín
Accurate timing characterization of detected radiation events in Positron Emission Tomography (PET) provides Time-of-flight (TOF) information for detected coincidences, which improves the signal-to-noise ratio of the reconstructed images. In this work, we propose a method, called MLTiming, to train machine learning (ML) models to assign accurate timestamps to events measured in radiation detectors training using just the signals detected by the individual single-channel detectors, without the need of resorting to other detector signals nor simulations. We performed a proof-of-concept study using three different neural network (NN) architectures, including the recently proposed Kolmogorov-Arnold network (KAN), trained with event pairs constructed with the measured signal and a delayed version of it. The delay is used as a label in the training process. The proposed trained model was evaluated with coincidence data acquired with a 22Na point source using a pair of LaBr3(Ce) crystals in the shape of truncated cones coupled to fast photomultiplier tubes (PMTs). The detected γ-ray pulses were sampled at 5 Gsamples/s. A 3% improvement in Coincidence Time Resolution (CTR) over an ultra optimized genetic algorithm–enhanced digital CFD (D-CFD) method (246±3 ps to 238±1 ps) was achieved. The possibility of training ML models for each individual detector using only the information contained in their own detected events may facilitate the use of ML models for large and medium-sized scanners, as well as other research areas. MLTiming is available at https://github.com/wjosefw/MLTiming.git.
Docta Complutense
Publicación Artículo científico (JournalArticle)

PROTOTWIN-PET: A deep learning and GPU-based workflow for dose verification in proton therapy with PET

  • Cabrales, Pablo
  • Onecha, Víctor V.
  • Izquierdo-García, David
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • López Herraiz, Joaquín
In proton therapy (PT), accurate dose delivery verification is critical for detecting treatment plan deviations. This can be achieved by imaging activated positron emitters with a positron emission tomography (PET) acquisition and converting the data into a delivered dose image. This work presents PROTOTWIN-PET (PROTOn therapy digital TWIN models for dose verification with PET), a patient-specific, deep learning (DL) and GPU-based workflow for 3-D dose verification. The proposed workflow generates a dataset of simulated, realistic 3-D PET and dose pairs that reflect possible clinical deviations in patient positioning and physical parameters. Using this dataset, a DL model is trained to estimate the delivered dose from the PET image, incorporating a deviation-predicting branch (DPB) to estimate patient positioning deviations. PROTOTWIN-PET is demonstrated on a two-field oropharyngeal cancer treatment plan, estimating the delivered dose in milliseconds with an average mean relative error of 0.6% and near-perfect gamma passing rates (3 mm, 3%). Positioning deviations are estimated on average within a tenth of a millimeter and degree. PROTOTWIN-PET can be implemented within the one-day interval between the plan CT acquisition and the first treatment session, potentially enabling timely treatment plan adjustments and maximizing the precision of PT. PROTOTWIN-PET is available at github.com/pcabrales/prototwin-pet.git.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Development and validation of a Monte Carlo model of a mobile accelerator for intraoperative radiation therapy

  • Ayala, Rafael
  • Soza, Álvaro
  • García, María Jesús
  • García, Rocío
  • Udías Moinelo, José Manuel
  • Ibáñez García, Paula Beatriz
Background Intraoperative electron radiation therapy (IOERT) relies on accurate and precise dose delivery to the tumor or tumor bed using mobile accelerators and interchangeable applicators, while critical organs are typically displaced or shielded during surgery. Treatment planning and linac commissioning are often based on water measurements, Monte Carlo (MC) simulations of the accelerator head and applicator system provide detailed insights into dose distributions and beam characteristics, offering additional support for clinical evaluation. Purpose This study develops an MC model of the Liac HWL mobile accelerator using a hypothetical linac head geometry, due to the limited availability of detailed information on its internal components resulting from manufacturer disclosure policies. The model is optimized by adjusting three geometric parameters of the linac head and the initial beam energy spectrum to match experimental data. Additionally, it provides a set of Phase Space Files (PSFs) to support research and clinical applications. Methods The MC code PENELOPE, integrated with the penEasy framework, was used to simulate the Liac HWL. The hypothetical head geometry was defined by parameters such as the inner diameter of the head, the thickness of the scattering foil, and the thickness of the exit window. Output factors (OFs), percentage depth doses (PDDs), and off‐axis ratios (OARs) were calculated in a virtual water phantom for different applicator sizes, bevel angles, and energies. Gamma analysis was employed to validate the model by comparing calculated and measured dose distributions. PSFs were made available in the IAEA PHSP format at four energies (6, 8, 10, and 12 MeV). Results The model matched measured OFs within 2.5%. PDDs and OARs met the gamma analysis criteria (2% dose difference and 1 mm distance‐to‐agreement) in more than 93% of the studied cases, with the worst‐case scenario occurring for the smallest applicator (3 cm diameter) with a 45° bevel angle at 6 MeV, resulting in OAR gamma passing rates of 85.7% at and 86.1% at . Conclusions Despite the use of a hypothetical geometry, the model offers accurate dosimetric data and practical guidance for IOERT commissioning and treatment planning. It highlights potential dosimetric issues, particularly the lack of homogeneity in OARs for large‐diameter applicators, and allows fine‐tuning based on real‐world data. Additionally, the PSFs generated in this study provide a reliable resource for simulating IORT dose distributions and analyzing the characteristics of IOERT beams.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Time response of an undoped LaCl3 crystal

  • Caballero Rodríguez, Miriam
  • Sánchez Tembleque Verbo, Víctor
  • Fraile Prieto, Luis Mario
  • Fonseca Vargas, C.
  • Gaitán Domínguez, Sara
  • Kim, H.J.
  • Martínez Nouvilas, Víctor
  • Martínez Roig, M.
  • Nácher, E.
  • Udías Moinelo, José Manuel
  • Vuong, P.Q.
We have characterized a detector equipped with an undoped LaCl truncated cone crystal with dimensions of 22.5 mm in the largest diameter, 16 mm in the smallest diameter, and 16 mm in height, coupled to a fast Photonis XP2020/URQ photomultiplier tube (PMT). Its time response at 511 keV (22Na) and 60Co photon energies has been measured against a reference detector using a fast digitizer module by digital signal processing methods based on a genetic algorithm. The time resolution was optimized by the choice of the photomultiplier bias voltage and the fine-tuning of the digital parameters of the time pickup algorithm. The de-convoluted full width at half maximum (FWHM) time resolution is found to be 250 ± 10 ps at 60Co energies, and 444 ± 8 ps using positron annihilation -rays from 22Na, providing good prospects for the use of the crystal in applications requiring a fast time response.