Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Correction: Feasibility study of a SiPM-fiber detector for non-invasive measurement of arterial input function for preclinical and clinical positron emission tomography

  • de Scals, Sara
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • Cortés, Laura Martínez
  • Oteo, Marta
  • Morcillo, Miguel Ángel
  • Carreras-Delgado, José Luis
  • Carreras Delgado, José Luis
  • Cabrera Martín, María Nieves
  • España Palomares, Samuel
Correction: EJNMMI Phys11, 12 (2024). https://doi.org/10.1186/s40658-024-00618-2 Following publication of the original article [1], the authors requested to update the Funding section. The original Funding sections was: This work was funded by the Universidad Complutense de Madrid under Project PR27/21 − 009 and by the Ministerio de Ciencia e Innovación under Project TED2021-129933B-C21. S. España is supported by the Ministerio de Ciencia, Innovación y Universidades under Ayudas Ramón y Cajal RYC2018-024495-I. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020-001041-S funded by MICIN/AEI/https://doi.org/10.13039/501100011033). The correct Funding section should read: This work is part of the Project TED2021-129933B-C21 funded by the MCIN/AEI/10.13039/501100011033 and the European Union NextGenerationEU/ PRTR as well as by the Universidad Complutense de Madrid under Project PR27/21-009. S. España is supported by the Ministerio de Ciencia, Innovación y Universidades under Ayudas Ramón y Cajal RYC2018-024495-I. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020-001041-S funded by MICIN/AEI/10.13039/501100011033). The original article [1] has been updated.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fast-Timing Detector through Redshifted Cherenkov Radiation

  • Fernández-Borreguero, C.
  • Fraile, L. M.
  • Udias, J.M
  • España, Samuel
10th Conference on PET, SPECT, and MR Multimodal Technologies, Total Body and Fast Timing in Medical Imaging, 20-23 May, 2024, Isola d'Elba, Italy. 10 figuras, 2 tablas., This study explores advancements in Time-of-Flight PET (TOF-PET) technology, specifically focusing on Redshifted Cherenkov Radiators (RCR) to enhance time resolution in radiation detectors. TOF-PET utilizes radiotracers labeled with positron-emitting radionuclides to track biological targets, aiding in diagnosis, treatment planning, and therapeutic monitoring. Recent hardware, radiotracer, and image analysis advancements have expanded TOF-PET's clinical applications. This study concentrates on the development of RCRs to further improve TOF-PET capabilities. Evaluation of solvents¿ODE, CHCl3, DMSO¿reveals ODE's superior UV transparency. The addition of POPOP dopant in ODE significantly enhances the detection of Cherenkov photons, demonstrating the potential of RCR. Time-correlated single photon counting (TCSPC) analysis indicates that RCR detectors offer competitive time responses compared to pure Cherenkov detectors. Coincidence measurements with LYSO detectors demonstrate favorable Coincidence Time Resolutions (CTR) for RCR detectors. These findings offer insights into the optimization of RCRs, suggesting their role in advancing TOF-PET imaging for enhanced diagnostic accuracy and therapeutic monitoring., This work was funded by the Universidad Complutense de Madrid under Project PR27/21-009 and by MICIN/AEI/https://doi.org/10.13039/501100011033 under projects TED2021-129933B-C21 and TED2021- 130592B-I00. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020- 001041-S funded by MICIN/AEI/https://doi.org/10.13039/501100011033)., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

Feasibility study of a SiPM-fiber detector for non-invasive measurement of arterial input function for preclinical and clinical positron emission tomography

  • de Scals, Sara
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • Martínez Cortés, Laura
  • Oteo, Marta
  • Morcillo, Miguel Ángel
  • Carreras Delgado, José Luis
  • Cabrera Martín, María Nieves
  • España Palomares, Samuel
Pharmacokinetic positron emission tomography (PET) studies rely on the measurement of the arterial input function (AIF), which represents the time-activity curve of the radiotracer concentration in the blood plasma. Traditionally, obtaining the AIF requires invasive procedures, such as arterial catheterization, which can be challenging, time-consuming, and associated with potential risks. Therefore, the development of non-invasive techniques for AIF measurement is highly desirable. This study presents a detector for the non-invasive measurement of the AIF in PET studies. The detector is based on the combination of scintillation fibers and silicon photomultipliers (SiPMs) which leads to a very compact and rugged device. The feasibility of the detector was assessed through Monte Carlo simulations conducted on mouse tail and human wrist anatomies studying relevant parameters such as energy spectrum, detector efficiency and minimum detectable activity (MDA). The simulations involved the use of 18F and 68Ga isotopes, which exhibit significantly different positron ranges. In addition, several prototypes were built in order to study the different components of the detector including the scintillation fiber, the coating of the fiber, the SiPMs, and the operating configuration. Finally, the simulations were compared with experimental measurements conducted using a tube filled with both 18F and 68Ga to validate the obtained results. The MDA achieved for both anatomies (approximately 1000 kBq/mL for mice and 1 kBq/mL for humans) falls below the peak radiotracer concentrations typically found in PET studies, affirming the feasibility of conducting non-invasive AIF measurements with the fiber detector. The sensitivity for measurements with a tube filled with 18F (68Ga) was 1.2 (2.07) cps/(kBq/mL), while for simulations, it was 2.81 (6.23) cps/(kBq/mL). Further studies are needed to validate these results in pharmacokinetic PET studies.