Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Mapping intratumoral heterogeneity through PET-derived washout and deep learning after proton therapy

  • Cabrales, Pablo
  • Izquierdo-García, David
  • V. Onecha, Víctor
  • Pérez Liva, Mailyn
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • López Herraiz, Joaquín
The distribution of produced isotopes during proton therapy can be imaged with Positron Emission Tomography (PET) to verify dose delivery. However, biological washout, driven by tissue-dependent processes such as perfusion and cellular metabolism, reduces PET signal-to-noise ratio (SNR) and limits quantitative analysis. In this work, we propose an uncertainty-aware deep learning framework to improve the estimation of washout parameters in post-proton therapy PET, not only enabling accurate correction for washout effects, but also mapping intratumoral heterogeneity as a surrogate marker of tumor status and treatment response. We trained the models on Monte Carlo-simulated data from eight head-and-neck cancer patients, and tested them on four additional head-and-neck and one liver patient. Each patient was represented by 75 digital twins with distinct tumoral washout dynamics and imaged 15 min after treatment, when slow washout components dominate. We also introduced washed-out maps, quantifying the contribution of medium and fast washout components to the loss in activity between the end of treatment and the start of PET imaging. Trained models significantly improved resolution and accuracy, reducing average absolute errors by 60% and 28% for washout rate and washed-out maps, respectively. For intratumoral regions as small as 5.1 mL, errors predominantly fell below thresholds for differentiating vascular status, and the models generalized across anatomical areas and acquisition delays. This study shows the potential of deep learning in post-proton therapy PET to non-invasively map washout kinetics and reveal intratumoral heterogeneity, supporting dose verification, tumor characterization, and treatment personalization. The framework is available at https://github.com/pcabrales/ppw.git .
Docta Complutense
Publicación Artículo científico (JournalArticle)

miniTRASGO: design and initial results of a compact resistive plate chamber telescope for worldwide cosmic ray monitoring

  • Soneira-Landín, C.
  • Blanco, A.
  • Fraile Prieto, Luis Mario
  • Garzón, J.A.
  • Kornakov, G.
  • Lopes, L.
  • Michel, J.
  • Martínez Nouvilas, Víctor
  • Udías Moinelo, José Manuel
Cosmic rays, composed primarily of high-energy protons and atomic nuclei, interact with Earth’s atmosphere, generating secondary particles that can be detected at ground level. Understanding these interactions requires precise measurements across various geomagnetic and atmospheric conditions. To address this challenge, miniTRASGO is introduced: a cost-effective and portable cosmic ray detector based on Resistive Plate Chambers, designed for worldwide deployment. This study describes the miniTRASGO system, including its design, data acquisition, and calibration processes. The detector measures charged secondary cosmic rays, reconstructs particle trajectories, and accounts for environmental influences such as pressure and temperature. Performance evaluations indicate an angular precision better than and an efficiency of approximately 95 %. The first operational miniTRASGO stations, deployed in Madrid (Spain), Warsaw (Poland), Puebla, and Monterrey (Mexico), allow for multi-site monitoring of cosmic ray flux. A Forbush Decrease event observed in March 2024 by the Madrid station validates the detector’s capability for space weather studies. The results highlight the potential of miniTRASGO to contribute to global cosmic ray monitoring, improving the characterization of cosmic ray variations and their implications for space weather.