Pasar al contenido principal

DETECCION EN TIEMPO REAL DE CANCER DE COLON PARA LA EVALUACION DE LA CALIDAD DE LAS COLONOSCOPIAS

TIN2009-10435

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2009
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario CENTRO DE VISION POR COMPUTADOR
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

GRowing Algorithm for Intersection Detection (GRAID) in branching patterns

  • Núñez Do Rio, Joan M.|||0000-0001-8268-5389
  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Vilariño, Fernando|||0000-0002-7705-4141
Analysis of branching structures represents a very important task in fields such as medical diagnosis, road detection or biometrics. Detecting intersection landmarks becomes crucial when capturing the structure of a branching pattern. We present a very simple geometrical model to describe intersections in branching structures based on two conditions: Bounded Tangency (BT) condition and Shortest Branch (SB) condition. The proposed model precisely sets a geometrical characterization of intersections and allows us to introduce a new unsupervised operator for intersection extraction. We propose an implementation that handles the consequences of digital domain operation that, unlike existing approaches, is not restricted to a particular scale and does not require the computation of the thinned pattern. The new proposal, as well as other existing approaches in the bibliography, are evaluated in a common framework for the first time. The performance analysis is based on two manually segmented image data sets: DRIVE retinal image database and COLON-VESSEL data set, a newly created data set of vascular content in colonoscopy frames. We have created an intersection landmark ground truth for each data set besides comparing our method in the only existing ground truth. Quantitative results confirm that we are able to outperform state-of-the-art performance levels with the advantage that neither training nor parameter tuning is needed.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

WM-DOVA maps for accurate polyp highlighting in colonoscopy, Validation vs. saliency maps from physicians

  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Fernández-Esparrach, Gloria|||0000-0002-3378-3940
  • Gil, Debora|||0000-0002-2770-4767
  • Rodríguez De Miguel, Cristina|||0000-0002-5576-0854
  • Vilariño, Fernando|||0000-0002-7705-4141
We introduce in this paper a novel polyp localization method for colonoscopy videos. Our method is based on a model of appearance for polyps which defines polyp boundaries in terms of valley information. We propose the integration of valley information in a robust way fostering complete, concave and continuous boundaries typically associated to polyps. This integration is done by using a window of radial sectors which accumulate valley information to create WM-DOVA (Window Median Depth of Valleys Accumulation) energy maps related with the likelihood of polyp presence. We perform a double validation of our maps, which include the introduction of two new databases, including the first, up to our knowledge, fully annotated database with clinical metadata associated. First we assess that the highest value corresponds with the location of the polyp in the image. Second, we show that WM-DOVA energy maps can be comparable with saliency maps obtained from physicians' fixations obtained via an eye-tracker. Finally, we prove that our method outperforms state-of-the-art computational saliency results. Our method shows good performance, particularly for small polyps which are reported to be the main sources of polyp miss-rate, which indicates the potential applicability of our method in clinical practice.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Towards Automatic Polyp Detection with a Polyp Appearance Model

  • Bernal del Nozal, Jorge|||0000-0001-8493-9514
  • Sánchez, F. Javier|||0000-0002-9364-3122
  • Vilariño, Fernando|||0000-0002-7705-4141
This work aims at automatic polyp detection by using a model of polyp appearance in the context of the analysis of colonoscopy videos. Our method consists of three stages: region segmentation, region description and region classification. The performance of our region segmentation method guarantees that if a polyp is present in the image, it will be exclusively and totally contained in a single region. The output of the algorithm also defines which regions can be considered as non-informative. We define as our region descriptor the novel Sector Accumulation-Depth of Valleys Accumulation (SA-DOVA), which provides a necessary but not sufficient condition for the polyp presence. Finally, we classify our segmented regions according to the maximal values of the SA-DOVA descriptor. Our preliminary classification results are promising, especially when classifying those parts of the image that do not contain a polyp inside.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Low Cost Eye Tracking, The Current Panorama

  • Ferhat, Onur
  • Vilariño, Fernando|||0000-0002-7705-4141
Despite the availability of accurate, commercial gaze tracker devices working with infrared (IR) technology, visible light gaze tracking constitutes an interesting alternative by allowing scalability and removing hardware requirements. Over the last years, this field has seen examples of research showing performance comparable to the IR alternatives. In this work, we survey the previous work on remote, visible light gaze trackers and analyze the explored techniques from various perspectives such as calibration strategies, head pose invariance, and gaze estimation techniques. We also provide information on related aspects of research such as public datasets to test against, open source projects to build upon, and gaze tracking services to directly use in applications. With all this information, we aim to provide the contemporary and future researchers with a map detailing previously explored ideas and the required tools.