Pasar al contenido principal

TECNICAS HARDWARE Y SOFTWARE PARA EL ANALISIS, DETECCION Y RECUPERACION DE ERRORES INDUCIDOS POR LA RADIACION EN SISTEMAS DIGITALES EMBARCADOS EN MISIONES ESPACIALES II

TIN2017-87237-P

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D (Excelencia / Generación de Conocimiento)
Año convocatoria 2017
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of a COTS 65-nm SRAM under 15 MeV protons and 14 MeV neutrons at low VDD

  • Rezaei, Mohammadreza
  • Martín Holgado, Pedro
  • Morilla, Yolanda
  • Franco, Francisco J.
  • Fabero, Juan Carlos
  • Mecha, Hortensia
  • Puchner, Helmut
  • Hubert, Guillaume
  • Clemente, Juan Antonio
This article presents an experimental study on the sensitivity of a commercial-off-the-shelf (COTS) bulk 65-nm static random access memory (SRAM) under 15.6 MeV proton irradiation when powered up at ultralow bias voltage. Tests were run on standby and while reading the memory. Results show obvious evidence indicating that decreasing the bias voltage below 1 V exponentially increases the number of observed errors. Single-bit upsets (SBUs) and multiple-cell upsets (MCUs) (mostly with vertical shapes according to the manufacturers' layout) are reported and their behavior is analyzed in this article. Predictions on the single-event upset (SEU) sensitivity obtained with the multiscales single-event phenomena predictive platform (MUSCA-SEP3) modeling tool are also provided and compared with the experimental results. These are also compared with 14.2 MeV neutrons, showing a significant difference in the cross sections for both irradiation sources. Total ionizing dose (TID) tests and GEANT4 simulations were also run to check for the reason behind the difference in the cross section between these two particles., This work was supported in part by the Spanish MINECO project TIN2017-87237. The work at the CNA has been supported in part by the Spanish Ministry of Economy and Competitiveness under project ESP2015-68245-C4-4-P., Peer reviewed
Docta Complutense
Publicación Artículo científico (JournalArticle)

A real-time FPGA implementation of the CCSDS 123.0-B-2 standard

  • González, Carlos
  • Mozos Muñoz, Daniel
  • Bascones García, Daniel
Hyperspectral images are a useful remote sensing tool which often reach hundreds of megabytes in size. The CCSDS 123.0-B-2 is a recent algorithm that achieves lossless and nearlossless compression of hyperspectral images by introducing a configurable maximum error over its predecessor CCSDS 123.0- B-1. In this paper, an FPGA implementation of the revised standard that works in real-time is presented. We have developed an extremely pipelined and fast core in VHDL, that is able to process a sample per cycle at over 250MHz, working 8 times faster than real-time for the AVIRIS-NG sensor. New dependencies in the revised standard are avoided by using a novel sample ordering called Frame Interleaved by Diagonal. The predictor stage has been designed to work in this order, and two reorder buffers encapsulate it to be Band Interleaved by Pixel compliant. Predictor data is encoded using a novel FPGA implementation of the CCSDS 123.0-B-2 hybrid coder. The modules are tested and verified on a Virtex-7 VC709 board. For medium (256 bands × 4096 frames × 512 samples) and large (512×4096×1024) images, the core occupies respectively 14% and 50% of a XQRKU060 FPGA.