Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Analysis of several biomechanical models for the simulation of lamb liver behaivour using similarity coefficients from medical image

  • Martínez Martínez, Francisco
  • Lago Ángel, Miguel Ángel
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • C. Monserrat|||0000-0003-1790-8085
In this study, six biomechanical models for simulating lamb liver behaviour are presented. They are validated using similarity coefficients from Medical Image on reconstructed volumes from computerised tomography images. In particular, the Jaccard and Hausdorff coefficients are used. Loads of 20 and 40 g are applied to the livers and their deformation is simulated by means of the finite element method. The models used are a linear elastic model, a neo-Hookean model, a Mooney¿Rivlin model, an Ogden model, a linear viscoelastic model and a viscohyperelastic model. The model that provided a behaviour that is closest to reality was the viscohyperelastic model, where the hyperelastic part was modelled with an Ogden model., This project has been partially funded by MITYC (reference TSI-020100-2009-189), by CDTI (reference IDI-20101153) and by MICINN (reference TIN2010-20999-C04-01). We would like to express our gratitude to the personnel from the HCB hospital where the experiments with the CT Machine were carried out.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Liver segmentation in MRI: a fully automatic method based on stochastic partitions

  • López-Mir, Fernando|||0000-0001-8286-6796
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Angulo, J.
  • Luna, L.
There are few fully automated methods for liver segmentation in magnetic resonance images (MRI) despite the benefits of this type of acquisition in comparison to other radiology techniques such as computed tomography (CT). Motivated by medical requirements, liver segmentation in MRI has been carried out. For this purpose, we present a new method for liver segmentation based on the watershed transform and stochastic partitions. The classical watershed over-segmentation is reduced using a marker-controlled algorithm. To improve accuracy of selected contours, the gradient of the original image is successfully enhanced by applying a new variant of stochastic watershed. Moreover, a final classifier is performed in order to obtain the final liver mask. Optimal parameters of the method are tuned using a training dataset and then they are applied to the rest of studies (17 datasets). The obtained results (a Jaccard coefficient of 0.91 +/- 0.02) in comparison to other methods demonstrate that the new variant of stochastic watershed is a robust tool for automatic segmentation of the liver in MRI. (C) 2014 Elsevier Ireland Ltd. All rights reserved., This work has been supported by the MITYC under the project NaRALap (ref. TSI-020100-2009-189), partially by the CDTI under the project ONCOTIC (IDI-20101153), by Ministerio de Educacion y Ciencia Spain, Project Game Teen (TIN2010-20187) projects Consolider-C (SEJ2006-14301/PSIC), "CIBER of Physiopathology of Obesity and Nutrition, an initiative of ISCIII" and Excellence Research Program PROMETEO (Generalitat Valenciana. Conselleria de Educacion, 2008-157). We would like to express our gratitude to the Hospital Clinica Benidorm, for providing the MR datasets and to the radiologist team of Inscanner for the manual segmentation of the MR images.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

NaRALap: augmented reality system for navigation in laparoscopic surgery

  • López-Mir, Fernando|||0000-0001-8286-6796
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • C. Monserrat|||0000-0003-1790-8085
  • Martínez Martínez, Francisco
  • Fuertes Cebrián, Juan José
  • Lago, M. A.
The AR system has a good resolution and currently is used for the placement of the trocars. Possible improvements will be performed to make the system independent of the camera position or to use natural marks. The biomechanical model and the AR algorithms will be combined with a tracker, for tracking the surgical instruments, in order to implement a valid system for liver biopsies. It will take into account the deformation due to the pneumoperitoneum and due to the breath of the patient. To develop the navigator that will guide the laparoscopic interventions, both AR system and biomechanical model will be combined with the laparoscopic camera in order to make an easier environment with only one vision in a 2D monitor., This work has been supported by the project MITYC (ref. TSI020100-2009-189). We would like to express our deep gratitude to the Hospital Clínica Benidorm for its participation in this project.