Effect of steel tube thickness on the behaviour of CFST columns: Experimental tests and design assessment

  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Hernández-Figueirido, D.
  • Piquer, A.
[EN] In this paper, the results of experimental tests conducted on concrete-filled steel tubular (CFST) columns are presented. There is currently a deficit of data available that can be used to evaluate current guidance documents and provide assessment to improve their accuracy when considering the behaviour of CFST columns filled with high strength concrete. Thus, this paper aims to increase the volume of experimental data available with a series of groups of tests on stub CFST columns subject to axial compression. Among the specimens of the same group only one dimension changes, the steel tube thickness. The columns are filled with both normal and high strength concrete for comparison purposes. The use of high strength concrete in circular tubes increases the concrete contribution, but this effect does not fulfil in rectangular specimens where also the confinement is less effective than in circular CFST even when the former have thin steel tubes and high strength concrete. The specifications of four commonly used codes are discussed. Comparison of their predictions with the experimental data collected shows that AISC is conservative but EC4, DBJ and AS produce similar non-conservative predictions., The authors would like to express their sincere gratitude to Universitat Jaume I for the funding provided through the projects P1- 1A2015-06 and UJI-B2018-58.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental analysis on circular concrete-filled steel tubular beam-columns under unequal load eccentricities

  • Albero, V|||0000-0001-7193-9232
  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Hernández-Figueirido, D.
  • Piquer, A.
[EN] This paper presents eight experimental tests on circular concrete-filled steel tubular (CFST) beam-columns loaded under unequal eccentricities at both ends. This loading scheme has not been widely studied yet in previous research works on CFST columns, but it may be very common into industrial or residential multi-storey frames, where both ends are subjected to different bending moments. Tests results revealed that the ultimate resisting load increases when the column is loaded under unequal eccentricities compared to what is loaded under equal eccentricities. However, under certain conditions, the column ductility decreases. Also, the equations provided by the Eurocode 4 and AISC 360-16 for second order effects were assessed. Specifically, the equivalent moment factors, beta or C-m, were calculated from experimental data and compared to those given by the standards. Although Eurocode 4 presents more accurate predictions, both codes provide safe predictions for higher slenderness beam columns but unsafe predictions for double curvature members with low slenderness. In view of the results, further research is needed to improve the equivalent moment factor proposals including additional parameters apart from the loading eccentricity ratio., The authors would like to express their sincere gratitude to Uni-versitat Jaume I for the funding provided through the project UJI-B2018-58. Funding for open access charge: CRUE-Universitat Jaume I.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Behaviour of slender concrete-filled dual steel tubular columns subjected to eccentric loads

  • Albero, V|||0000-0001-7193-9232
  • Ibáñez, Carmen|||0000-0002-9354-5637
  • Piquer, A.
  • Hernández-Figueirido, D.
[EN] In this paper an experimental program on concrete-filled steel tubular columns subjected to eccentric loads is presented. The columns have different cross-sectional configurations, including single concrete-filled steel tubular columns (CFST) and concrete-filled dual steel tubular columns (CFDST). The response of all the columns was studied and the physical state of all the specimens after the tests was checked. The level of utilisation achieved by each type of column in relation to its cross-sectional resistance was analysed together with the influence of the extra inner tube or the inner filling of concrete for the CFDST specimens. Finally, EN1994-1-1 provisions were assessed by comparing the experimental results with the predictions given by the simplified method which appears to be conservative in this case., The authors would like to express their sincere gratitude to Universitat Jaume I for the funding provided through the project UJI-B2018-58.