Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of the effects of Atosiban on uterine electromyograms recorded in women with threatened preterm labor

  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales, Alfredo
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
[EN] Although research studies using electrohysterography on women without tocolytic therapy have shown its potential for preterm birth diagnosis, tocolytics are usually administered in emergency rooms at the first sign of threatened preterm labor (TPL). Information on the uterine response during tocolytic treatment could prove useful for the development of tools able to predict true preterm deliveries under normal clinical conditions. The aim of this study was thus to analyze the effects of Atosiban on Electrohysterogram (EHG) parameters and to compare its effects on women who delivered preterm (WDP) and at term (WDT). Electrohysterograms recorded in different Atosiban therapy stages (before, during and after drug administration) on 40 WDT and 27 WDP were analyzed by computing linear, and non-linear EHG parameters. Results reveal that Atosiban does not greatly affect the EHG signal amplitude, but does modify its spectral content and reduces the energy associated with the fast wave high component in both WDP and WDT, with a faster response in the latter. EHG signal complexity remained constant in WDT, while it increased in WDP until it reached similar values to WDT during Atosiban treatment. The spectral and complexity parameters were able to separate (p < 0.05) WDT and WDP prior to and during tocolytic treatment and before and after treatment, respectively. The results pave the way for developing better and more reliable medical decision support systems based on EHG for preterm delivery prediction in TPL women in clinical scenarios., This work received financial support from the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R), VLC/Campus (UPV-FE-2018-B03) and by Conselleria de Educación, Investigación, Cultura y Deporte, Generalitat Valenciana (GV/2018/104).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design and Assessment of a Robust and Generalizable ANN-Based Classifier for the Prediction of Premature Birth by means of Multichannel Electrohysterographic Records

  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales Marín, Alfredo José
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Preterm labor is one of the major causes of neonatal deaths and also the cause of significant health and development impairments in those who survive. However, there are still no reliable and accurate tools for preterm labor prediction in clinical settings. Electrohysterography (EHG) has been proven to provide relevant information on the labor time horizon. Many studies focused on predicting preterm labor by using temporal, spectral, and nonlinear parameters extracted from single EHG recordings. However, multichannel analysis, which includes information from the whole uterus and about coupling between the recording areas, may provide better results. The cross validation method is often used to design classifiers and evaluate their performance. However, when the validation dataset is used to tune the classifier hyperparameters, the performance metrics of this dataset may not properly assess its generalization capacity. In this work, we developed and compared different classifiers, based on artificial neural networks, for predicting preterm labor using EHG features from single and multichannel recordings. A set of temporal, spectral, nonlinear, and synchronization parameters computed from EHG recordings was used as the input features. All the classifiers were evaluated on independent test datasets, which were never ¿seen¿ by the models, to determine their generalization capacity. Classifiers¿ performance was also evaluated when obstetrical data were included. The experimental results show that the classifier performance metrics were significantly lower in the test dataset (AUC range 76-91%) than in the train and validation sets (AUC range 90-99%). The multichannel classifiers outperformed the single-channel classifiers, especially when information was combined into mean efficiency indexes and included coupling information between channels. Including obstetrical data slightly improved the classifier metrics and reached an AUC of for the test dataset. These results show promise for the transfer of the EHG technique to preterm labor prediction in clinical practice., This work was supported by the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (DPI2015-68397-R, MINECO/FEDER, and RTI2018-094449-A-I00-AR); Generalitat Valenciana (AICO/2019/220); and the VLC/Campus (UPV-FE-2018-B03).