Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193954
Dataset. 2019

DEEP SEISMIC REFLECTION PROFILE (IBERSEIS NORMAL INCIDENCE TRANSECT)

IBERSEIS NI - RAW DATA

  • Pérez-Estaún, Andrés
  • Simancas, José Fernando
  • González Lodeiro, Francisco
  • Ayarza, P.
  • Azor, Antonio
  • Juhlin, C.
  • Sáez, R.
  • Almodóvar, G. R.
  • Carbonell, Ramón
IBERSEIS is a 303 km long deep seismic reflection profile. The transect was recorded in 56 days (from May to July 2001) using a 400 channel SERCEL 388 and five 22 Ton Vibroseis trucks. The asymmetric split spread configuration changed along the profile according to the dips of outcropping structures. To achieve a high resolution at shallow levels and to image steep dips, a 35 m station spacing and a 70 m Vibration Point interval was used with a high fold (60 in average). A relatively long sweep (20 s) was chosen to increase the source energy rather than increasing the number of sweeps per Vibration Point. The migrated and stack dataset derived from this raw data are available in http://hdl.handle.net/10261/220989, IBERSEIS NI: Migrated and stack files: http://dx.doi.org/10.20350/digitalCSIC/12643 ; http://hdl.handle.net/10261/220989, IBERSEIS Normal Incidence (IBERSEIS-NI) is a NE-SW oriented deep seismic reflection profile that provided for the first time a complete section at crustal scale of the Variscan Iberian Massif in the SW of Spain. This seismic profile samples three major tectonic terranes: the South Portuguese Zone, the Ossa-Morena Zone, and the Central Iberian Zone. These terranes show a distinctive seismic signature, as do the sutures separating them. Late strike-slip movements through crustal wedges are apparent in the seismic image and have strongly modified the geometry of sutures. The upper crust appears to be decoupled from the lower crust all along the seismic line, but some deformation has been accommodated at deeper levels. A sill-like structure is imaged in the middle crust as a 1–2 s thick and 175 km long high-amplitude conspicuous reflective band. It is interpreted as a great intrusion of mafic magma in a mid-crustal decollement. Taking into account surface geological data and the revealed crustal architecture, a tectonic evolution is proposed for SW Iberia which includes transpressional collision interacting during Early Carboniferous with a mantle plume. The Moho can be identified along the entire transect as subhorizontal and located at 10 to 11 s, indicating a 30–35 km average crustal thickness. Its seismic signature changes laterally, being very reflective beneath the South Portuguese Zone and the Central Iberian Zone, but discontinuous and diffuse below the Ossa Morena Zone., Comisión Interministerial de Ciencia y Tecnología-Fondo Europeo de Desarrollo Regional (CICYT-FEDER), 1FD1997-2179/RYEN1.-- Junta de Andalucía.-- ENRESA.-- Swedish Research Council.-- Instituto Geológico y Minero de España.-- Spanish Ministry of Science and Technology, BTE2000-0583-C02-01, BTE2000-3035-E, BTE2000-1490-C02-01, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/193954
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193954
HANDLE: http://hdl.handle.net/10261/193954
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193954
PMID: http://hdl.handle.net/10261/193954
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193954
Ver en: http://hdl.handle.net/10261/193954
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193954

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193986
Dataset. 2019

WIDE-ANGLE DEEP SEISMIC REFLECTION PROFILE (IBERSEIS WIDE-ANGLE TRANSECT)

  • Palomeras, Imma
  • Simancas, José Fernando
  • Ayarza, P.
  • González Lodeiro, Francisco
  • Pérez-Estaún, Andrés
  • Azor, Antonio
  • Carbonell, Ramón
The wide-angle seismic reflection data set consists of two transects. Transect A coincides with the trace of the IBERSEIS deep seismic reflection profile and transect B is located farther to the SE. The explosive charge was located in a single 20 cm diameter, 50–60-m deep shothole. Explosive shots with charge sizes of 1000, 750 and 500 kg, where distributed along the transect, with the largest charges located at the edges of the profile. 650 digital seismic recorders (590 Texans and 60 3-component Refteks) from IRIS (Incorporated Research Institutions for Seismology) instrument pool where used. These instruments where placed along the 300-km transect A at a 400-m station spacing. For transect B, a denser trace spacing was used. To achieve this, shots were fired twice. The stations were firstly placed at 300–400 m spacing along transect B. Once the shots were fired, the stations were moved 150–200 m toward the north along the profile. All shots were then fired a second time, resulting in shot records with a 150–200 m trace spacing., The IBERSEIS wide-angle seismic reflection dataset consists of two NE-SW oriented transects acquired in the SW of the Iberian Massif. They crossed three major geological zones (South Portuguese Zone, Ossa-Morena Zone, and Central Iberian Zone), with their tectonic contacts and the Pyrite Belt being of greatest interest. The velocity models obtained by forward modeling show a complex crust, especially in the middle crust. The velocity models are the most detailed ones that have been produced in the area and contain a large amount of new features that are relevant to the understanding of the composition of the crust and upper mantle beneath the zone., Spanish Ministry of Science and Innovation, CGL2004-04623, CSD2006-00041.-- Generalitat de Catalunya.-- Junta de Andalucía.--, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/193986
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193986
HANDLE: http://hdl.handle.net/10261/193986
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193986
PMID: http://hdl.handle.net/10261/193986
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193986
Ver en: http://hdl.handle.net/10261/193986
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/193986

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194002
Dataset. 2019

DEEP SEISMIC REFLECTION PROFILE (ALCUDIA NORMAL INCIDENCE TRANSECT)

  • Pérez-Estaún, Andrés
  • Simancas, José Fernando
  • González Lodeiro, Francisco
  • Ayarza, P.
  • Azor, Antonio
  • Martínez Poyatos, D.
  • Carbonell, Ramón
The ALCUDIA transect is a 230 km long, vertical incidence deep seismic reflection profile acquired in 2007. The acquisition parameters, 35 m station spacing, 70 m Vibration Point spacing resulted in a 60-90 fold high resolution seismic reflection image. A 20 s long Vibroseis sweep with frequencies between 8-80 Hz was recorded by a 400 station recording cable and 14 km long split spread configuration., ALCUDIA Normal Incidence (ALCUDIA-NI) is a NE-SW oriented vertical incidence deep seismic reflection transect in the SW of Spain that aimed to image the Variscan Iberian Massif. This transect sampled the Central Iberian Zone and was designed to be the northward continuation of the IBERSEIS-NI seismic profile. The processed image shows a weakly reflective upper crust, a thick, highly reflective and laminated lower crust, and a flat Moho located at 10 s TWTT (30 km depth). The transect can be divided into three segments with different structural styles in the lower crust. In the central segment, the lower crust is imaged by regular, horizontal and parallel reflectors, whereas in the northern and southern segments it displays oblique reflectors interpreted as an important thrust (north) and tectonic wedging involving the mantle (south). The ALCUDIA-NI shows that in an intracontinental orogenic crust, far from the suture zones, the upper and lower crust may react differently to shortening in different sectors, which is taken as evidence for decoupling. The interpreted structures, as deduced from surface geology and the seismic image, show that deformation was distributed homogeneously in the upper crust, whereas it was concentrated in wedge/thrust structures at specific sectors in the lower crust., Spanish Ministry of Science and Innovation, CGL2004-04623/BTE, CSD2006-00041.-- Ministerio de economía y competitividad, CGL2007-63101/BTE.-- Ministerio de economía y competitividad; Fondos Europeos de desarrollo regional (FEDER), CGL2011-24101.-- Junta de Castilla-La Mancha.--, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/194002
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194002
HANDLE: http://hdl.handle.net/10261/194002
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194002
PMID: http://hdl.handle.net/10261/194002
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194002
Ver en: http://hdl.handle.net/10261/194002
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194002

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194009
Dataset. 2019

WIDE-ANGLE DEEP SEISMIC REFLECTION PROFILE (ALCUDIA WIDE-ANGLE TRANSECT)

  • Pérez-Estaún, Andrés
  • Ayarza, P.
  • Martínez Poyatos, D.
  • Simancas, José Fernando
  • Azor, Antonio
  • Carbonell, Ramón
The acquisition design included three lines of receivers, having a total length of ca. 350 km. The main line, ALCUDIA-WA, is ca. 310 km long strikes NE-SW to NNE-SSW, it is approximately perpendicular to the structural grain. A 40 km long line of receivers that trends NNW-SSE was deployed perpendicular to the Central System (CS) mountain range. Over 900 TEXANS (single component, digital recording seismic station) from the IRIS-PASSCAL Instrument Pool were deployed from the northern boundary of the Ossa-Morena Zone to the alpine thrust representing the southern boundary of the CS. The entire ALCUDIA-WA survey had a nominal shot and receiver spacing of 70 km and 400m, respectively. Five explosive sources, each one consisting in 1 TM of explosive, were placed in ~55m deep single boreholes, providing a signal rich in high frequencies resulting in shot records characterized by high signal-to-noise ratio. For this reason, these data can be qualified as a high-resolution wide-angle data set., The high-resolution, wide-angle seismic reflection experiment, ALCUDIA-WA, was acquired in 2012 across central Iberia, aiming to constrain the lithospheric structure and resolve the physical properties of the crust and upper mantle. The seismic transect, ca. 310 km long, crossed the Central Iberian Zone from its suture with the Ossa Morena Zone to the southern limit of the Central System mountain range., Spanish Ministry of Science and Innovation, CGL2004-04623/BTE, CGL2007-63101/BTE, CGL2011-24101, CSD2006-00041.--, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/194009
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194009
HANDLE: http://hdl.handle.net/10261/194009
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194009
PMID: http://hdl.handle.net/10261/194009
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194009
Ver en: http://hdl.handle.net/10261/194009
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/194009

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196460
Dataset. 2019

DYBAGA: WEEKLY HYDROGRAPHIC DATASET ON SW GALICIAN SHELF

  • Pérez, Fiz F.
  • Nieto-Cid, Mar
  • Álvarez-Salgado, Xosé Antón
  • Castro, Carmen G.
  • Rosón, Gabriel
  • Redondo, W.
  • Gilcoto, Miguel
  • Ríos, Aida F.
Este dataset está compuesto por 2 archivos, de los cuales el primero es el conjunto de datos con 1421 análisis de muestras de agua de temperatura, salinidad, oxígeno, nutrientes, pH, alcalinidad, clorofila y materia orgánica, y el otro (Readme.txt) incluye una pequeña descripción de las variables calculadas, Durante un año, se estudió la variabilidad a frecuencia semanal de los fenómenos de afloramiento y hundimiento en la plataforma gallega frente a la Ría de Vigo y su impacto en las diferentes variables biogeoquímicas y del ciclo del carbono. Se evaluó la importancia relativa de los procesos físicos y biológicos en la variabilidad de la pCO2. Se determinaron las tasas netas de producción de especies de carbono en el ecosistema (DIC, POC, DOC) para evaluar la importancia relativa de la acumulación versus la exportación de fracciones orgánicas disueltas y partículas recién formadas. El trabajo de campo también desarrolla el estudio de las composiciones elementales y bioquímicas de (1) la materia orgánica disuelta en el agua de mar, (2) las partículas blandas y duras suspendidas en el agua y (3) los materiales biogénicos que han sido mineralizados en la columna de agua del sistema de afloramiento del noroeste ibérico. Cuatro estaciones fueron muestreadas semanalmente desde mayo de 2001 hasta abril de 2002 entre la plataforma de separación y el centro de la Ría de Vigo (45 m de profundidad). La salinidad y la temperatura se registraron con una sonda de profundidad de conductividad-temperatura SBE 9/11 conectada al muestreador de roseta con doce botellas de PVC Niskin de 10 L con muelles internos de acero inoxidable. Las mediciones de la conductividad se convirtieron en valores prácticos de la escala de salinidad con la ecuación de la UNESCO (1986). La precisión de las mediciones de CTD para temperatura y salinidad fueron de 0,004 DEG-C y 0,005, respectivamente. Las muestras para los análisis de oxígeno disuelto, pH, alcalinidad total, sales de nutrientes, carbono orgánico disuelto y particulado y nitrógeno fueron recogidas semanalmente con la roseta de 12 botellas Niskin. Para la determinación de nutrientes, las muestras de agua se recogieron en botellas de polietileno de 50 ml y se mantuvieron frías (4ºC) hasta su análisis en el laboratorio utilizando procedimientos estándar de análisis de flujo segmentado. Las precisiones fueron 0,02 microM para nitrito, 0,1 microM para nitrato, 0,05 microM para amonio, 0,02 microM para fosfato y 0,05 microM para silicato. El oxígeno se determinó por titulación potenciométrica de Winkler utilizando un analizador Titrino 720 con una precisión de 0,5 micromol/kg. Las muestras de alcalinidad total (TA) y pH (escala de concentración total de hidrógeno, 25°C) se recogieron en frascos de vidrio de 500 ml y se analizaron en pocas horas en el laboratorio base. El pH del agua de mar se midió espectrofotométricamente siguiendo a Clayton y Byrne (1993) aplicándose una adición de 0,0047 (DelValls & Dickson, 1998). La precisión fue 0,003 unidades de pH. El TA se determinó por titulación a pH 4,4 con HCl, según el método potenciométrico de Pérez y Fraga (1987) con una precisión de ±2 micromol/kg, La materia orgánica suspendida se recolectó bajo vacío en filtros precombustionados (450ºC, 4 horas) Whatman GF/F de 25 mm de diámetro y 0,7 micrómetros de tamaño nominal de poro (POC/PON, 0,5-1,5 L de agua de mar). Todos los filtros se secaron durante la noche y se congelaron (-20ºC) antes del análisis. Las mediciones de POC y PON se realizaron con un analizador Perkin Elmer 2400 CHN. Se utilizó un estándar de acetanilida diariamente. La precisión del método es de 0,3 micromol C/L y 0,1 micromol N/L. La materia orgánica disuelta se recolectó en frascos de 500 ml limpiados con ácido y se filtraron a través de filtros precombustionados (450°C, 4 horas) Whatman GF/F de 47 mm de diámetro (tamaño nominal de poro, 0,7 mm) en un sistema de filtración de vidrio limpiado con ácido, a baja presión de flujo N2. Las alícuotas para el análisis de DOC/DON se recogieron en ampollas de vidrio precombustionadas de 10 mL (450 °C, 12 horas). Después de la acidificación con H3PO4 a pH<2, las ampollas fueron termoselladas y almacenadas en la oscuridad a 4°C hasta el análisis. DOC y DON se midieron simultáneamente con un detector de quimioluminiscencia de óxido nítrico Antek 7020 específico de nitrógeno, acoplado en serie con el analizador de gas infrarrojo específico de carbono de un analizador de carbono orgánico Shimadzu TOC-5000 (Alvarez-Salgado y Miller, 1998). La precisión es de 0,7 micromol C/L para el carbono y 0,2 micromol N/L para el nitrógeno, CSIC y Plan Nacional de I+D del Gobierno de España, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/196460
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196460
HANDLE: http://hdl.handle.net/10261/196460
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196460
PMID: http://hdl.handle.net/10261/196460
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196460
Ver en: http://hdl.handle.net/10261/196460
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196460

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196476
Dataset. 2019

REMODA SURVEYS: HYDROGRAPHIC AND CHEMICAL DATA

  • Álvarez-Salgado, Xosé Antón
  • Álvarez, Marta
  • Brea, S.
  • Castro, Carmen G.
  • Gago, Jesús
  • Gilcoto, Miguel
  • Nieto-Cid, Mar
  • Piedracoba, Silvia
  • Rellán, Trinidad
  • Redondo, W.
  • Rosón, Gabriel
  • Souto, C.
  • Varela, Ramiro
Este dataset está compuesto por 2 archivos, de los cuales el primero es el conjunto de datos con 203 análisis de muestras de agua de temperatura, salinidad, oxígeno, nutrientes, pH, alcalinidad, clorofila y materia orgánica disuelta y particulada, y el otro (Readme.txt) incluye una pequeña descripción de las variables calculadas, REMODA se centra en el estudio del origen y destino de la materia orgánica disuelta en la Ría de Vigo a escalas temporales corta (3–4 días) y estacional. Se combinan medidas de variables de estado relevantes (carbono y nitrógeno orgánico, carbohidratos, fluorescencia tanto de la materia orgánica disuelta como en suspensión) con tasas de producción/consumo, tanto microbiano como fotoquímico (oxigeno, fluorescencia). Estas se relacionan con las condiciones, meteorológicas, termohalinas e hidrodinámicas del medio. Se muestrearon tres estaciones en una sección transversal en el centro de la Ría de Vigo. La estación central con 45 m de profundidad, se ha realizado un amplió muestreo de variables de estado. La salinidad y la temperatura se registraron con una sonda de profundidad de conductividad-temperatura SBE 9/11 conectada al muestreador de roseta con doce botellas de PVC Niskin de 10 L con muelles internos de acero inoxidable. Las mediciones de la conductividad se convirtieron en valores prácticos de la escala de salinidad con la ecuación de la UNESCO (1986). La precisión de las mediciones de CTD para temperatura y salinidad fueron de 0,004 ºC y 0,005, respectivamente. Para la determinación de oxígeno disuelto, las muestras se recogieron directamente en frascos de vidrio calibrados de 110 mL y, tras la fijación con Cl2Mn y NaOH/NaI, se mantuvieron en la oscuridad hasta su análisis en el laboratorio 24 horas más tarde. El oxígeno se determinó por titulación potenciométrica del punto final de Winkler utilizando un analizador Titrino 720 (Metrohm) con una precisión de 0,5 micromol/kg., Para la determinación de nutrientes, las muestras de agua se recogieron en botellas de polietileno de 50 ml y se mantuvieron frías (4ºC) hasta su análisis en el laboratorio utilizando procedimientos estándar de análisis de flujo segmentado. Las precisiones fueron 0,02 microM para nitrito, 0,1 microM para nitrato, 0,05 microM para amonio, 0,02 microM para fosfato y 0,05 microM para silicato. Las muestras de alcalinidad total (TA) y pH (escala de concentración total de hidrógeno, 25°C) se recogieron en frascos de vidrio de 500 ml y se analizaron en pocas horas en el laboratorio base. El pH del agua de mar se midió espectrofotométricamente siguiendo a Clayton y Byrne (1993) aplicándose una adición de 0,0047 (DelValls & Dickson, 1998). La precisión fue 0.003 unidades de pH. El TA se determinó por titulación a pH 4,4 con HCl, según el método potenciométrico de Pérez y Fraga (1987) con una precisión de ±2 micromol/kg. La materia orgánica suspendida se recolectó bajo vacío en filtros precombustionados (450ºC, 4 horas) Whatman GF/F de 25 mm de diámetro y 0,7 micrómetros de tamaño nominal de poro (POC/PON, 0,5-1,5 L de agua de mar). Todos los filtros se secaron durante la noche y se congelaron (-20ºC) antes del análisis. Las mediciones de POC y PON se realizaron con un analizador Perkin Elmer 2400 CHN. Se utilizó un estándar de acetanilida diariamente. La precisión del método es de 0,3 microM para el carbono y 0,1 microM para el nitrógeno. La determinación de fósforo orgánico particulado (POP), se siguieron los mismos procedimientos de recolección y almacenamiento que para POC/PON, después de la filtración de 250 ml de agua de mar. Se determinó por digestión H2SO4/HClO4 a 220°C del material particulado recogido en los filtros GF/F de Whatman. El ácido fosfórico producido se analizó, tras la neutralización, mediante el procedimiento SFA para el fosfato. Los estándares de fosfato se aplicaron todos los días de análisis. La precisión para todo el análisis fue de 0.02 microM., La materia orgánica disuelta se recolectó en frascos de 500 ml limpiados con ácido y se filtraron a través de filtros precombustionados (450°C, 4 horas) Whatman GF/F de 47 mm de diámetro (tamaño nominal de poro, 0,7 mm) en un sistema de filtración de vidrio limpiado con ácido, a baja presión de flujo N2. Las alícuotas para el análisis de DOC/DON se recogieron en ampollas de vidrio precombustionadas de 10 mL (450 °C, 12 horas). Después de la acidificación con H3PO4 a pH<2, las ampollas fueron termoselladas y almacenadas en la oscuridad a 4°C hasta el análisis. DOC y DON se midieron simultáneamente con un detector de quimioluminiscencia de óxido nítrico Antek 7020 específico de nitrógeno, acoplado en serie con el analizador de gas infrarrojo específico de carbono de un analizador de carbono orgánico Shimadzu TOC-5000 (Alvarez-Salgado y Miller, 1998). La precisión es de 0,7 microM para el carbono y 0,2 microM para el nitrógeno. Las muestras para la determinación de fosforo orgánico disuelto fueron recolectadas y filtradas como se indica para las muestras DOC/DON. El filtrado se recogió en contenedores de polietileno de 50 mL y se congeló a -20°C hasta su análisis. Se midió mediante el sistema SFA para fosfato, tras la oxidación con Na2S2O8/borax y la radiación UV (Armstrong et al., 1966). Sólo se analizan los ésteres orgánicos monofosfóricos, ya que los polifosfatos son resistentes a este procedimiento de oxidación. Calibraciones diarias con fosfato, fosfato de fenilo y adenosina 5'-monofosfato (AMP) en de agua de mar. Se analizaron las normas de AMP para calcular la recuperación de los ésteres monofosfóricos (alrededor del 80%). La precisión del método se estimó en 0,04 microM, CSIC y Plan Nacional de I+D del Gobierno de España, 1 data csv ‘29MY20020702_hy1.csv’ file and 1 readme.txt file, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/196476
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196476
HANDLE: http://hdl.handle.net/10261/196476
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196476
PMID: http://hdl.handle.net/10261/196476
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196476
Ver en: http://hdl.handle.net/10261/196476
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196476

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196478
Dataset. 2019

CRIA SURVEYS: HYDROGRAPHIC AND CHEMICAL DATA

  • Barton, Eric D.
  • Castro, Carmen G.
  • Alonso Pérez, Fernando
  • Zúñiga, Diana
  • Rellán, Trinidad
  • Arbones, Belén
  • Castaño, Mónica
  • Gilcoto, Miguel
  • Torres, R.
  • Figueiras, F. G.
  • Pérez, Fiz F.
  • Ríos, Aida F.
Este dataset está compuesto por 2 archivos, de los cuales el primero es el conjunto de datos con 197 análisis de muestras de agua de temperatura, salinidad, oxígeno, nutrientes, pH, alcalinidad, clorofila y materia orgánica disuelta y particulada, y el otro (Readme.txt) incluye una pequeña descripción de las variables calculadas, El proyecto CRIA tuvo como objetivos (1) determinar la trayectoria y naturaleza del flujo a través de la ría exterior, (2) examinar la configuración de la circulación de las dos capas y seguir la propagación de las aguas afloradas y hundidas a través de la ría, y (3) determinar la tasa de descarga y las velocidades verticales relacionadas en la ría, tanto en condiciones de afloramiento como de hundimiento. Las observaciones detalladas proporcionan una visión de alta resolución de los procesos de intercambio entre los océanos y las rías y revelan importantes asimetrías en las respuestas de afloramiento y de hundimiento. En septiembre de 2006 y junio de 2007, a bordo R/V Mytilus, se realizaron tomas de muestras hidrográficas en la Ría de Vigo acompañando un muestreo de alta frecuencia sobre la circulación. Tiradas con un SeaBird 9/11 CTD equipado con una roseta con botellas Niskin de 1.7 L, para capturar muestras de agua de tres a seis profundidades. Se tomaron muestras para la determinación de salinidad, clorofila, nutrientes, pH y alcalinidad. Las salinidades se determinaron en un salinómetro Guildline Autosal 8400. La precisión de las mediciones de CTD para temperatura y salinidad fueron de 0,004 ºC y 0,005, respectivamente. Para la determinación de oxígeno disuelto, las muestras se recogieron directamente en frascos de vidrio calibrados de 110 mL y, tras la fijación con Cl2Mn y NaOH/NaI, se mantuvieron en la oscuridad hasta su análisis en el laboratorio 24 horas más tarde. El oxígeno se determinó por titulación potenciométrica del punto final de Winkler utilizando un analizador Titrino 720 (Metrohm) con una precisión de 0,5 micromol/kg., Para la determinación de nutrientes, las muestras de agua se recogieron en botellas de polietileno de 50 ml y se mantuvieron frías (4ºC) hasta su análisis en el laboratorio utilizando procedimientos estándar de análisis de flujo segmentado. Las precisiones fueron 0,02 micromol/L para nitrito, 0,1 microM para nitrato, 0,05 micromol/L para amonio, 0,02 micromol/L para fosfato y 0,05 micromol/L para silicato. Las muestras de alcalinidad total (TA) y pH (escala de concentración total de hidrógeno, 25°C) se recogieron en frascos de vidrio de 500 ml y se analizaron en pocas horas en el laboratorio base. El pH del agua de mar se midió espectrofotométricamente siguiendo a Clayton y Byrne (1993) aplicándose una adición de 0,0047 (DelValls & Dickson, 1998). La precisión fue 0.003 unidades de pH. El TA se determinó por titulación a pH 4,4 con HCl, según el método potenciométrico de Pérez y Fraga (1987) con una precisión de ±2 micromol/kg. Se determinaron las concentraciones de clorofila A en un fluorómetro TD700 de Turner Designs después de filtrar 100 ml de agua de mar a través de filtros GF/F de 25 mm [Welschmeyer, 1994]. La materia orgánica suspendida se recolectó bajo vacío en filtros precombustionados (450ºC, 4 horas) Whatman GF/F de 25 mm de diámetro y 0,7 micrómetros de tamaño nominal de poro (POC/PON, 0,5-1,5 L de agua de mar). Todos los filtros se secaron durante la noche y se congelaron (-20ºC) antes del análisis. Las mediciones de POC y PON se realizaron con un analizador Perkin Elmer 2400 CHN. Se utilizó un estándar de acetanilida diariamente. La precisión del método es de 0,3 micromol/L para el carbono y 0,1 micromol/L para el nitrógeno. La determinación de fósforo orgánico particulado (POP), se siguieron los mismos procedimientos de recolección y almacenamiento que para POC/PON, después de la filtración de 250 ml de agua de mar. Se determinó por digestión H2SO4/HClO4 a 220°C del material particulado recogido en los filtros GF/F de Whatman. El ácido fosfórico producido se analizó, tras la neutralización, mediante el procedimiento SFA para el fosfato. Los estándares de fosfato se aplicaron todos los días de análisis. La precisión para todo el análisis fue de 0.02 micromol/L, CSIC y Plan Nacional de I+D del Gobierno de España, Peer reviewed

Proyecto: //
DOI: http://hdl.handle.net/10261/196478
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196478
HANDLE: http://hdl.handle.net/10261/196478
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196478
PMID: http://hdl.handle.net/10261/196478
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196478
Ver en: http://hdl.handle.net/10261/196478
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/196478

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/197045
Dataset. 2019

ARIOS SURVEYS: HYDROGRAPHIC AND CHEMICAL DATA ON SW GALICIAN SHELF

  • Padín, X. A.
  • Doval, M. Dolores
  • Álvarez-Fernández, María Jesús
  • Rey, J.
  • Rellán, Trinidad
  • Fontela, Marcos
  • Broullón, Daniel
  • Mohamed-Santamaría, Sara
  • Gilcoto, Miguel
  • Prego, R.
  • Pérez, Fiz F.
Este dataset está compuesto por 2 archivos, de los cuales el primero es el conjunto de datos con 1421 análisis de muestras de agua de temperatura, salinidad, oxígeno, nutrientes, pH, alcalinidad, clorofila y materia orgánica, y el otro (Readme.txt) incluye una pequeña descripción de las variables calculadas, Durante un año, se estudió la variabilidad a frecuencia mensual (quincenal en la época estival) de los fenómenos de afloramiento y hundimiento en la plataforma gallega frente a la Ría de Vigo y su impacto en las diferentes variables biogeoquímicas y del ciclo del carbono. Se evaluó la importancia relativa de los procesos físicos y biológicos en la variabilidad del sistema del carbonato con especial interés en la acidificación oceánica. Nueve estaciones fueron muestreadas desde el nueve de junio 2017 hasta junio del 2018 desde el borde del talud continental frente Ría de Vigo hasta el interior de la misma en el límite del estuario de San Simón. La salinidad y la temperatura se registraron con una sonda de profundidad de conductividad-temperatura SBE 9/11 conectada al muestreador de roseta con doce botellas de PVC Niskin de 10 L. Las mediciones de la conductividad se convirtieron en valores prácticos de la escala de salinidad con la ecuación de la UNESCO (1986). La precisión de las mediciones de CTD para temperatura y salinidad fueron de 0,004 ºC y 0,005, respectivamente. Las muestras para los análisis de oxígeno disuelto, pH, alcalinidad total, sales de nutrientes, carbono orgánico disuelto fueron recogidas semanalmente con la roseta de 12 botellas Niskin. Para la determinación de nutrientes, las muestras de agua se recogieron en botellas de polietileno de 50 mL y se congelaron (-20ºC) hasta su análisis en el laboratorio utilizando procedimientos estándar de análisis de flujo segmentado. Las precisiones fueron 0,02 micromol/L para nitrito, 0,1 micromol/L para nitrato, 0,05 micromol/L para amonio, 0,02 micromol/L para fosfato y 0,05 micromol/L para silicato. El oxígeno se determinó por titulación potenciométrica de Winkler utilizando un analizador Titrino 720 con una precisión de 0,5 micromol/kg. Las muestras de alcalinidad total (TA) y pH (escala de concentración total de hidrógeno, 25°C) se recogieron en frascos de vidrio de 500 mL y se analizaron en pocas horas en el laboratorio base. El pH del agua de mar se midió espectrofotométricamente siguiendo a Clayton y Byrne (1993) aplicándose una adición de 0,0047 (DelValls & Dickson, 1998). La precisión fue 0,003 unidades de pH. El TA se determinó por titulación a pH 4,4 con HCl, según el método potenciométrico de Pérez y Fraga (1987) con una precisión de 2 micromol/kg, CSIC y Plan Nacional de I+D del Gobierno de España, 1 data csv ‘29MY20170609_hy1.csv’ file and 1 readme.txt file, Peer reviewed

DOI: http://hdl.handle.net/10261/197045
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/197045
HANDLE: http://hdl.handle.net/10261/197045
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/197045
PMID: http://hdl.handle.net/10261/197045
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/197045
Ver en: http://hdl.handle.net/10261/197045
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/197045

Buscador avanzado