Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Lateral flow immunoassay for simultaneous detection of C. difficile, MRSA, and K. pneumoniae

  • Rubio-Monterde, Ana|||0000-0003-0068-9621
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Gallegos, Marc
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Merkoçi, Arben|||0000-0003-2486-8085
Mainly performed within a rapid diagnostic tests company, a lateral flow (LF) system using gold nanoparticles (AuNPs) as transducers is presented able to detect three bacteria of interest, of relevance for antimicrobial resistance (AMR): Clostridioides difficile, methicillin-resistant Staphylococcus aureus (MRSA), and Klebsiella pneumoniae, with a limit of detection of 25 ng/mL of glutamate dehydrogenase (GDH) for C. difficile, 36 ng/mL of penicillin-binding protein 2a (PBP2a) for MRSA, and 4 × 10 CFU/mL for K. pneumoniae. The system showed good results with bacteria culture samples, is user-friendly, and suitable for rapid testing, as the results are obtained within 15 min.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Wearable, battery-free, wireless multiplexed printed sensors for heat stroke prevention with mussel-inspired bio-adhesive membranes

  • Maroli, Gabriel|||0000-0001-8921-4205
  • Rosati, Giulio|||0000-0002-0227-4561
  • Suárez García, Salvio|||0000-0002-4156-0579
  • Bedmar-Romero, Daniel
  • Kobrin, Robert
  • González-Laredo, Álvaro
  • Urban, Massimo|||0000-0001-6083-833X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Ruiz-Molina, Daniel|||0000-0002-6844-8421
  • Merkoçi, Arben|||0000-0003-2486-8085
Wearable technologies are becoming pervasive in our society, and their development continues to accelerate the untapped potential of continuous and ubiquitous sensing, coupled with big data analysis and interpretation, has only just begun to unfold. However, existing wearable devices are still bulky (mainly due to batteries and electronics) and have suboptimal skin contact. In this work, we propose a novel approach based on a sensor network produced through inkjet printing of nanofunctional inks onto a semipermeable substrate. This network enables real-time monitoring of critical physiological parameters, including temperature, humidity, and muscle contraction. Remarkably, our system operates under battery-free and wireless near-field communication (NFC) technology for data readout via smartphones. Moreover, two of the three sensors were integrated onto a naturally adhesive bioinspired membrane. This membrane, developed using an eco-friendly, high-throughput process, draws inspiration from the remarkable adhesive properties of mussel-inspired molecules. The resulting ultra-conformable membrane adheres effortlessly to the skin, ensuring reliable and continuous data collection. The urgency of effective monitoring systems cannot be overstated, especially in the context of rising heat stroke incidents attributed to climate change and high-risk occupations. Heat stroke manifests as elevated skin temperature, lack of sweating, and seizures. Swift intervention is crucial to prevent progression to coma or fatality. Therefore, our proposed system holds immense promise for the monitoring of these parameters on the field, benefiting both the general population and high-risk workers, such as firefighters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Introducing all-inkjet-printed microneedles for in-vivo biosensing

  • Rosati, Giulio|||0000-0002-0227-4561
  • Deroco, Patricia Batista
  • Bonando, Matheus Guitti
  • Dalkiranis, Gustavo G.
  • Cordero Edwards, Kumara|||0000-0003-3721-7863
  • Maroli, Gabriel|||0000-0001-8921-4205
  • Kubota, Lauro Tatsuo
  • Oliveira, Osvaldo N.|||0000-0002-5399-5860
  • Saito, Lúcia Akemi Miyazato
  • De Carvalho Castro Silva, Cecilia|||0000-0003-3933-1838
  • Merkoçi, Arben|||0000-0003-2486-8085
Microneedles are mainly used for pain-free drug administration and in biosensing for wearable systems. They are also promising for fields such as agronomy for precision farming, but their fabrication is not straightforward, often requiring expensive equipment and cleanroom protocols, being unsuitable for mass production. Here, we report a new and simple method for the scalable fabrication of all-inkjet-printed conductive microneedles based on silver nanoparticles (extensible to any other metallic nanoparticle ink) and a simple example of their application for monitoring the electrochemical properties of plants.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

High resolution portable platform for pH sensing via colorimetric fluorescence of carbon dots

  • Minervini, Gianluca|||0000-0001-5607-8868
  • Panniello, Annamaria|||0000-0002-4907-2473
  • Quesada-González, Daniel|||0000-0003-3064-2146
  • Maroli, Gabriel|||0000-0001-8921-4205
  • Fanizza, Elisabetta|||0000-0001-6293-9388
  • Striccoli, Marinella|||0000-0002-5366-691X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Curri, Maria Lucia|||0000-0002-0261-8379
  • Merkoçi, Arben|||0000-0003-2486-8085
Portable sensing platforms based on nanoparticles are becoming increasingly significant across diverse fields, as they enable real-time measurements in various environments without complex lab protocols. Carbon dots (CDs), known for low toxicity and intense fluorescence, can exhibit pH-dependent optical emission, generally related to proton exchange-capable surface groups. In addition, CDs' hydrophilicity, biocompatibility, and stability make them advantageous for pH sensing and, despite limited application in portable sensing devices, their full potential can be realized with precise control of chemistry and optical properties. In this study, we fabricate a portable nitrocellulose-based platform for pH sensing, expressly designed to take advantage of the fluorescence properties of resorcinol-based CDs. First, responsivity of CDs fluorescence features on pH is carefully spectroscopically characterized and linked to acid-base equilibria of polyphenols (hydroxylated polyaromatic rings) present within the CDs carbonaceous structure. Notably, this also offers a titrimetric method to estimate CD concentration. Next, nitrocellulose-based wax-printed circular pads are functionalized with CDs and integrated with a smartphone-based fluorescence colorimetric optical detection system. The developed portable device exhibits a measurement resolution of ± 0.2 pH units (in the range between 2.5 and 6.7) and of ± 0.3 pH units (in the 6.7 - 7.0 range), compatible with most practical pH measurement needs in biological, food and drink, wastewater sample analysis and others. Moreover, although some portable pH sensing devices are already widespread and commercially available, this platform is easy to use, it necessitates only very small sample volumes and is potentially adaptable to various environments and automated analysis processes that does not need prior-use calibrations.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Harnessing Bioluminescent Bacteria to Develop an Enzymatic-free Enzyme-linked immunosorbent assay for the Detection of Clinically Relevant Biomarkers

  • Hu, Liming|||0000-0002-8666-9287
  • Rossetti, Marianna|||0000-0001-5711-1287
  • Bergua Canudo, José Francisco|||0000-0002-5969-193X
  • Parolo, Claudio|||0000-0001-9481-4408
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Rivas, Lourdes|||0000-0002-1510-5927
  • Idili, Andrea|||0000-0002-6004-270X
  • Merkoçi, Arben|||0000-0003-2486-8085
Enzyme-linked immunosorbent assay (ELISA) is the gold standard technique for measuring protein biomarkers due to its high sensitivity, specificity, and throughput. Despite its success, continuous advancements in ELISA and immunoassay formats are crucial to meet evolving global challenges and to address new analytical needs in diverse applications. To expand the capabilities and applications of immunoassays, we introduce a novel ELISA-like assay that we call Bioluminescent-bacteria-linked immunosorbent assay (BBLISA). BBLISA is an enzyme-free assay that utilizes the inner filter effect between the bioluminescent bacteriaAllivibrio fischeriand metallic nanoparticles (gold nanoparticles and gold iridium oxide nanoflowers) as molecular absorbers. Functionalizing these nanoparticles with antibodies induces their accumulation in wells upon binding to molecular targets, forming the classical immune-sandwich complex. Thanks to their ability to adsorb the light emitted by the bacteria, the nanoparticles can suppress the bioluminescence signal, allowing the rapid quantification of the target. To demonstrate the bioanalytical properties of the novel immunoassay platform, as a proof of principle, we detected two clinically relevant biomarkers (human immunoglobulin G and SARS-CoV-2 nucleoprotein) in human serum, achieving the same sensitivity and precision as the classic ELISA. We believe that BBLISA can be a promising alternative to the standard ELISA techniques, offering potential advancements in biomarker detection and analysis by combining nanomaterials with a low-cost, portable bioluminescent platform.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Reduced graphene oxide electrodes meet lateral flow assays, A promising path to advanced point-of-care diagnostics

  • Calucho, Enric|||0000-0002-6024-765X
  • Álvarez Diduk, Ruslan|||0000-0002-9876-1574
  • Piper, Andrew|||0000-0002-1208-8009
  • Rossetti, Marianna|||0000-0001-5711-1287
  • Nevanen, Tarja K.
  • Merkoçi, Arben|||0000-0003-2486-8085
Research in electrochemical detection in lateral flow assays (LFAs) has gained significant momentum in recent years. The primary impetus for this surge in interest is the pursuit of achieving lower limits of detection, especially given that LFAs are the most widely employed point-of-care biosensors. Conventionally, the strategy for merging electrochemistry and LFAs has centered on the superposition of screen-printed electrodes onto nitrocellulose substrates during LFA fabrication. Nevertheless, this approach poses substantial limitations regarding scalability. In response, we have developed a novel method for the complete integration of reduced graphene oxide (rGO) electrodes into LFA strips. We employed a CO laser to concurrently reduce graphene oxide and pattern nitrocellulose, exposing its backing to create connection sites impervious to sample leakage. Subsequently, rGO and nitrocellulose were juxtaposed and introduced into a roll-to-roll system using a wax printer. The exerted pressure facilitated the transfer of rGO onto the nitrocellulose. We systematically evaluated several electrochemical strategies to harness the synergy between rGO and LFAs. While certain challenges persist, our rGO transfer technology presents compelling potential for setting a new standard in electrochemical LFA fabrication.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Low-cost inkjet-printed nanostructured biosensor based on CRISPR/Cas12a system for pathogen detection

  • Carota, Angela Gilda
  • Bonini, A|||0000-0001-9511-0699
  • Urban, Massimo|||0000-0001-6083-833X
  • Poma, Noemi
  • Vivaldi, Federico Maria
  • Tavanti, Arianna
  • Rossetti, Marianna|||0000-0001-5711-1287
  • Rosati, Giulio|||0000-0002-0227-4561
  • Merkoçi, Arben|||0000-0003-2486-8085
  • Di Francesco, Fabio|||0000-0002-9285-1595
The escalating global incidence of infectious diseases caused by pathogenic bacteria, especially in developing countries, emphasises the urgent need for rapid and portable pathogen detection devices. This study introduces a sensitive and specific electrochemical biosensing platform utilising cost-effective electrodes fabricated by inkjet-printing gold and silver nanoparticles on a plastic substrate. The biosensor exploits the CRISPR/Cas12a system for detecting a specific DNA sequence selected from the genome of the target pathogen. Upon detection, the trans-activity of Cas12a/gRNA is triggered, leading to the cleavage of rationally designed single-strand DNA reporters (linear and hairpin) labelled with methylene blue (ssDNA-MB) and bound to the electrode surface. In principle, this sensing mechanism can be adapted to any bacterium by choosing a proper guide RNA to target a specific sequence of its DNA. The biosensor's performance was assessed for two representative pathogens (a Gram-negative, Escherichia coli, and a Gram-positive, Staphylococcus aureus), and results obtained with inkjet-printed gold electrodes were compared with those obtained by commercial screen-printed gold electrodes. Our results show that the use of inkjet-printed nanostructured gold electrodes, which provide a large surface area, in combination with the use of hairpin reporters containing a poly-T loop can increase the sensitivity of the assay corresponding to a signal variation of 86%. DNA targets amplified from various clinically isolated bacteria, have been tested and demonstrate the potential of the proposed platform for point-of-need applications.