Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing the performance of sensors for ozone pollution monitoring in a citizen science approach

  • Ripoll, Anna
  • Viana, Mar
  • Padrosa, M.
  • Querol, Xavier
  • Minutolo, A.
  • Hou, K. M.
  • Barceló-Ordinas, José María
  • García-Vidal, Jorge
Tropospheric ozone (O3) is an environmental pollutant of growing concern, especially in suburban and rural areas where the density of air quality monitoring stations is not high. In this type of areas citizen science strategies can be useful tools for awareness raising, but sensor technologies must be validated before sensor data are communicated to the public. In this work, the performance under field conditions of two custom-made types of ozone sensing devices, based on metal-oxide and electrochemical sensors, was tested. A large array of 132 metal-oxide (Sensortech MICS 2614) and 11 electrochemical (Alphasense) ozone sensors, built into 44 sensing devices, was co-located at reference stations in Italy (4 stations) and Spain (5). Mean R2 between sensor and reference data was 0.88 (0.78–0.96) and 0.89 (0.73–0.96) for Captor (metal-oxide) and Raptor (electrochemical) nodes. The metal-oxide sensors showed an upper limit (approximately 170 μg/m3) implying that these sensors may be useful to communicate mean ozone concentrations but not peak episodes. The uncertainty of the nodes was 10% between 100 and 150 μg/m3 and 20% between 150 and 200 μg/m3, for Captors, and 10% for >100 μg/m3 for Raptors. Operating both types of nodes up to 5 months did not evidence any clear influence of drifts. The use of these sensors in citizen science can be a useful tool for awareness raising. However, significant data processing efforts are required to ensure high data quality, and thus machine learning strategies are advisable. Relative uncertainties should always be reported when communicating ozone concentration data from sensing nodes. © 2018 The Authors, The authors would like to thank the anonymous reviewers, whose comments improved the manuscript significantly. This work was funded by H2020 project CAPTOR. The authors gratefully acknowledge the collaboration of the staff at the Department of the Environment of the Generalitat de Catalunya and at ARPA Lombardia (Agenzia Regionale per l'Ambiente), who kindly provided support for the deployment of the sensing nodes at reference stations and provided access to the reference data. Support is also acknowledged from AGAUR SGR44, the Agencia Estatal de Investigación (AEI; CGL2017-82093-ERC ), and the Spanish Ministry of Economy, Industry and Competitiveness ( EUIN2017-85799 ). Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Distributed multi-scale calibration of low-cost ozone sensors in wireless sensor networks

  • Barceló-Ordinas, José María
  • Ferrer-Cid, Pau
  • García-Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
New advances in sensor technologies and communications in wireless sensor networks have favored the introduction of low-cost sensors for monitoring air quality applications. In this article, we present the results of the European project H2020 CAPTOR, where three testbeds with sensors were deployed to capture tropospheric ozone concentrations. One of the biggest challenges was the calibration of the sensors, as the manufacturer provides them without calibrating. Throughout the paper, we show how short-term calibration using multiple linear regression produces good calibrated data, but instead produces biases in the calculated long-term concentrations. To mitigate the bias, we propose a linear correction based on Kriging estimation of the mean and standard deviation of the long-term ozone concentrations, thus correcting the bias presented by the sensors. © 2019, MDPI AG. All rights reserved., Funding text #1 Universitat Politecnica de Catalunya (UPC), UPC Campus Nord, 08034 Barcelona, Spain; pauferrercid12@gmail.com (P.F.-C.); jorge@ac.upc.edu (J.G.-V.) Institute of Environmental Assessment and Water Research, Spanish National Research Council (IDAEA-CSIC), 08034 Barcelona, Spain; anna.ripoll@idaea.csic.es (A.R.); mar.viana@idaea.csic.es (M.V.) Correspondence: joseb@ac.upc.edu; Tel.:+34-93-405-4051 Funding text #2 Funding: This work is supported by the National Spanish funding TIN2016-78473-C3-1-R, regional Spanish funding AGAUR 2017SGR-990, 2017-SGR-44, the Agencia Estatal de Investigación (AEI; CGL2017-82093-ERC), and the Spanish Ministry of Economy, Industry and Competitiveness (EUIN2017-85799) and European H2020 CAPTOR project., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multisensor Data Fusion Calibration in IoT Air Pollution Platforms.

  • Ferrer-Cid, Pau
  • Barceló-Ordinas, José María
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
This article investigates the calibration of low-cost sensors for air pollution. The sensors were deployed on three Internet of Things (IoT) platforms in Spain, Austria, and Italy during the summers of 2017, 2018, and 2019. One of the biggest challenges in the operation of an IoT platform, which has a great impact on the quality of the reported pollution values, is the calibration of the sensors in an uncontrolled environment. This calibration is performed using arrays of sensors that measure cross sensitivities and therefore compensate for both interfering contaminants and environmental conditions. This article investigates how the fusion of data taken by sensor arrays can improve the calibration process. In particular, calibration with sensor arrays, multisensor data fusion calibration with weighted averages, and multisensor data fusion calibration with machine learning models are compared. Calibration is evaluated by combining data from various sensors with linear and nonlinear regression models., National Spanish funding; Regional Project; EU H2020 CAPTOR Project; AGAUR SGR44; 10.13039/501100011033-Agencia Estatal de Investigación; Spanish Ministry of Economy, Industry and Competitiveness;, Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Self-calibration methods for uncontrolled environments in sensor networks: A reference survey

  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • Doudou, Messaoud
  • García Vidal, Jorge|||0000-0001-5969-1182
  • Badache, Nadjib
Growing progress in sensor technology has constantly expanded the number and range of low-cost, small, and portable sensors on the market, increasing the number and type of physical phenomena that can be measured with wirelessly connected sensors. Large-scale deployments of wireless sensor networks (WSN) involving hundreds or thousands of devices and limited budgets often constrain the choice of sensing hardware, which generally has reduced accuracy, precision, and reliability. Therefore, it is challenging to achieve good data quality and maintain error-free measurements during the whole system lifetime. Self-calibration or recalibration in ad hoc sensor networks to preserve data quality is essential, yet challenging, for several reasons, such as the existence of random noise and the absence of suitable general models. Calibration performed in the field, without accurate and controlled instrumentation, is said to be in an uncontrolled environment. This paper provides current and fundamental self-calibration approaches and models for wireless sensor networks in uncontrolled environments., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Multisensor data fusion calibration in IoT air pollution platforms

  • Ferrer Cid, Pau|||0000-0003-2112-8516
  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • García Vidal, Jorge|||0000-0001-5969-1182
  • Ripoll, Anna
  • Viana, Mar
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This article investigates the calibration of low-cost sensors for air pollution. The sensors were deployed on three Internet of Things (IoT) platforms in Spain, Austria, and Italy during the summers of 2017, 2018, and 2019. One of the biggest challenges in the operation of an IoT platform, which has a great impact on the quality of the reported pollution values, is the calibration of the sensors in an uncontrolled environment. This calibration is performed using arrays of sensors that measure cross sensitivities and therefore compensate for both interfering contaminants and environmental conditions. This article investigates how the fusion of data taken by sensor arrays can improve the calibration process. In particular, calibration with sensor arrays, multisensor data fusion calibration with weighted averages, and multisensor data fusion calibration with machine learning models are compared. Calibration is evaluated by combining data from various sensors with linear and nonlinear regression models., This work was supported in part by the NationalSpanish funding under Grant TIN2016-78473-C3-1-R, in part by RegionalProject under Grant 2017SGR-990, in part by EU H2020 CAPTOR Project, inpart by AGAUR SGR44, in part by the Agencia Estatal de Investigación underGrant CGL2017-82093-ERC, and in part by the Spanish Ministry of Economy,Industry and Competitiveness under Grant EUIN2017-85799, Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Distributed multi-scale calibration of low-cost ozone sensors in wireless sensor networks

  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • Ferrer Cid, Pau|||0000-0003-2112-8516
  • García Vidal, Jorge|||0000-0001-5969-1182
  • Ripoll, Anna
  • Viana, Mar
New advances in sensor technologies and communications in wireless sensor networks have favored the introduction of low-cost sensors for monitoring air quality applications. In this article, we present the results of the European project H2020 CAPTOR, where three testbeds with sensors were deployed to capture tropospheric ozone concentrations. One of the biggest challenges was the calibration of the sensors, as the manufacturer provides them without calibrating. Throughout the paper, we show how short-term calibration using multiple linear regression produces good calibrated data, but instead produces biases in the calculated long-term concentrations. To mitigate the bias, we propose a linear correction based on Kriging estimation of the mean and standard deviation of the long-term ozone concentrations, thus correcting the bias presented by the sensors., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Testing the performance of sensors for ozone pollution monitoring in a citizen science approach

  • Ripoll Ruiz, Aleix
  • Viana, Mar
  • Padrosa, Marc
  • Querol Carceller, Xavier
  • Minutolo, Andrea
  • Hou, Kun Mean
  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • García Vidal, Jorge|||0000-0001-5969-1182
Tropospheric ozone (O3) is an environmental pollutant of growing concern, especially in suburban and rural areas where the density of air quality monitoring stations is not high. In this type of areas citizen science strategies can be useful tools for awareness raising, but sensor technologies must be validated before sensor data are communicated to the public. In this work, the performance under field conditions of two custom-made types of ozone sensing devices, based on metal-oxide and electrochemical sensors, was tested. A large array of 132 metal-oxide (Sensortech MICS 2614) and 11 electrochemical (Alphasense) ozone sensors, built into 44 sensing devices, was co-located at reference stations in Italy (4 stations) and Spain (5). Mean R2 between sensor and reference data was 0.88 (0.78–0.96) and 0.89 (0.73–0.96) for Captor (metal-oxide) and Raptor (electrochemical) nodes. The metal-oxide sensors showed an upper limit (approximately 170 µg/m3) implying that these sensors may be useful to communicate mean ozone concentrations but not peak episodes. The uncertainty of the nodes was 10% between 100 and 150 µg/m3 and 20% between 150 and 200 µg/m3, for Captors, and 10% for >100 µg/m3 for Raptors. Operating both types of nodes up to 5 months did not evidence any clear influence of drifts. The use of these sensors in citizen science can be a useful tool for awareness raising. However, significant data processing efforts are required to ensure high data quality, and thus machine learning strategies are advisable. Relative uncertainties should always be reported when communicating ozone concentration data from sensing nodes., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A comparative study of calibration methods for low-cost ozone sensors in IoT platforms

  • Ferrer Cid, Pau|||0000-0003-2112-8516
  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • García Vidal, Jorge|||0000-0001-5969-1182
  • Ripoll, Anna
  • Viana, Mar
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper shows the result of the calibration process of an Internet of Things platform for the measurement of tropospheric ozone (O 3 ). This platform, formed by 60 nodes, deployed in Italy, Spain, and Austria, consisted of 140 metal–oxide O 3 sensors, 25 electro-chemical O 3 sensors, 25 electro-chemical NO 2 sensors, and 60 temperature and relative humidity sensors. As ozone is a seasonal pollutant, which appears in summer in Europe, the biggest challenge is to calibrate the sensors in a short period of time. In this paper, we compare four calibration methods in the presence of a large dataset for model training and we also study the impact of a limited training dataset on the long-range predictions. We show that the difficulty in calibrating these sensor technologies in a real deployment is mainly due to the bias produced by the different environmental conditions found in the prediction with respect to those found in the data training phase., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

H2020 project CAPTOR dataset: Raw data collected by low-cost MOX ozone sensors in a real air pollution monitoring network

  • Barceló Ordinas, José María|||0000-0002-9738-2425
  • Ferrer Cid, Pau|||0000-0003-2112-8516
  • García Vidal, Jorge|||0000-0001-5969-1182
  • Viana Rodríguez, Mar
  • Ripoll, Anna
The H2020 CAPTOR project deployed three testbeds in Spain, Italy and Austria with low-cost sensors for the measurement of tropospheric ozone (O3). The aim of the H2020 CAPTOR project was to raise public awareness in a project focused on citizen science. Each testbed was supported by an NGO in charge of deciding how to raise citizen awareness according to the needs of each country. The data presented in this document correspond to the raw data captured by the sensor nodes in the Spanish testbed using SGX Sensortech MICS 2614 metal-oxide sensors. The Spanish testbed consisted of the deployment of twenty-five nodes. Each sensor node included four SGX Sensortech MICS 2614 ozone sensors, one temperature sensor and one relative humidity sensor. Each node underwent a calibration process by co-locating the node at an EU reference air quality monitoring station, followed by a deployment in a sub-urban or rural area in Catalonia, Spain. All nodes spent two to three weeks co-located at a reference station in Barcelona, Spain (urban area), followed by two to three weeks co-located at three sub-urban reference stations near the final deployment site. The nodes were then deployed in volunteers' homes for about two months and, finally, the nodes were co-located again at the sub-urban reference stations for two weeks for final calibration and assessment of potential drifts. All data presented in this paper are raw data taken by the sensors that can be used for scientific purposes such as calibration studies using machine learning algorithms, or once the concentration values of the nodes are obtained, they can be used to create tropospheric ozone pollution maps with heterogeneous data sources (reference stations and low-cost sensors)., This work was funded by H2020 project CAPTOR, and supported by National Spanish project PID2019–107910RB-I00, and regional project 2017SGR-990, and with the support of Secretaria d’Universitats i Recerca de la Generalitat de Catalunya i del Fons Social Europeu. The authors gratefully acknowledge the collaboration of the staff at the Department of the Environment of the Generalitat de Catalunya who kindly provided support for the deployment of the sensing nodes at reference stations for calibrating the sensors and provided access to the reference data., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Distributed multi-scale calibration of low-cost ozone sensors in wireless sensor networks

  • Barceló Ordinas, José María
  • Ferrer Cid, Pau
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
New advances in sensor technologies and communications in wireless sensor networks have favored the introduction of low-cost sensors for monitoring air quality applications. In this article, we present the results of the European project H2020 CAPTOR, where three testbeds with sensors were deployed to capture tropospheric ozone concentrations. One of the biggest challenges was the calibration of the sensors, as the manufacturer provides them without calibrating. Throughout the paper, we show how short-term calibration using multiple linear regression produces good calibrated data, but instead produces biases in the calculated long-term concentrations. To mitigate the bias, we propose a linear correction based on Kriging estimation of the mean and standard deviation of the long-term ozone concentrations, thus correcting the bias presented by the sensors., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Multisensor data fusion calibration in IoT air pollution platforms

  • Ferrer Cid, Pau
  • Barceló Ordinas, José María
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This article investigates the calibration of low-cost sensors for air pollution. The sensors were deployed on three Internet of Things (IoT) platforms in Spain, Austria, and Italy during the summers of 2017, 2018, and 2019. One of the biggest challenges in the operation of an IoT platform, which has a great impact on the quality of the reported pollution values, is the calibration of the sensors in an uncontrolled environment. This calibration is performed using arrays of sensors that measure cross sensitivities and therefore compensate for both interfering contaminants and environmental conditions. This article investigates how the fusion of data taken by sensor arrays can improve the calibration process. In particular, calibration with sensor arrays, multisensor data fusion calibration with weighted averages, and multisensor data fusion calibration with machine learning models are compared. Calibration is evaluated by combining data from various sensors with linear and nonlinear regression models., This work was supported in part by the NationalSpanish funding under Grant TIN2016-78473-C3-1-R, in part by RegionalProject under Grant 2017SGR-990, in part by EU H2020 CAPTOR Project, inpart by AGAUR SGR44, in part by the Agencia Estatal de Investigación underGrant CGL2017-82093-ERC, and in part by the Spanish Ministry of Economy,Industry and Competitiveness under Grant EUIN2017-85799, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

H2020 project CAPTOR dataset: Raw data collected by low-cost MOX ozone sensors in a real air pollution monitoring network

  • Barceló Ordinas, José María
  • Ferrer Cid, Pau
  • García Vidal, Jorge
  • Viana Rodríguez, Mar
  • Ripoll, Anna
The H2020 CAPTOR project deployed three testbeds in Spain, Italy and Austria with low-cost sensors for the measurement of tropospheric ozone (O3). The aim of the H2020 CAPTOR project was to raise public awareness in a project focused on citizen science. Each testbed was supported by an NGO in charge of deciding how to raise citizen awareness according to the needs of each country. The data presented in this document correspond to the raw data captured by the sensor nodes in the Spanish testbed using SGX Sensortech MICS 2614 metal-oxide sensors. The Spanish testbed consisted of the deployment of twenty-five nodes. Each sensor node included four SGX Sensortech MICS 2614 ozone sensors, one temperature sensor and one relative humidity sensor. Each node underwent a calibration process by co-locating the node at an EU reference air quality monitoring station, followed by a deployment in a sub-urban or rural area in Catalonia, Spain. All nodes spent two to three weeks co-located at a reference station in Barcelona, Spain (urban area), followed by two to three weeks co-located at three sub-urban reference stations near the final deployment site. The nodes were then deployed in volunteers' homes for about two months and, finally, the nodes were co-located again at the sub-urban reference stations for two weeks for final calibration and assessment of potential drifts. All data presented in this paper are raw data taken by the sensors that can be used for scientific purposes such as calibration studies using machine learning algorithms, or once the concentration values of the nodes are obtained, they can be used to create tropospheric ozone pollution maps with heterogeneous data sources (reference stations and low-cost sensors)., This work was funded by H2020 project CAPTOR, and supported by National Spanish project PID2019–107910RB-I00, and regional project 2017SGR-990, and with the support of Secretaria d’Universitats i Recerca de la Generalitat de Catalunya i del Fons Social Europeu. The authors gratefully acknowledge the collaboration of the staff at the Department of the Environment of the Generalitat de Catalunya who kindly provided support for the deployment of the sensing nodes at reference stations for calibrating the sensors and provided access to the reference data., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Testing the performance of sensors for ozone pollution monitoring in a citizen science approach

  • Ripoll Ruiz, Aleix
  • Viana, Mar
  • Padrosa, Marc
  • Querol Carceller, Xavier
  • Minutolo, Andrea
  • Hou, Kun Mean
  • Barceló Ordinas, José María
  • García Vidal, Jorge
Tropospheric ozone (O3) is an environmental pollutant of growing concern, especially in suburban and rural areas where the density of air quality monitoring stations is not high. In this type of areas citizen science strategies can be useful tools for awareness raising, but sensor technologies must be validated before sensor data are communicated to the public. In this work, the performance under field conditions of two custom-made types of ozone sensing devices, based on metal-oxide and electrochemical sensors, was tested. A large array of 132 metal-oxide (Sensortech MICS 2614) and 11 electrochemical (Alphasense) ozone sensors, built into 44 sensing devices, was co-located at reference stations in Italy (4 stations) and Spain (5). Mean R2 between sensor and reference data was 0.88 (0.78–0.96) and 0.89 (0.73–0.96) for Captor (metal-oxide) and Raptor (electrochemical) nodes. The metal-oxide sensors showed an upper limit (approximately 170 µg/m3) implying that these sensors may be useful to communicate mean ozone concentrations but not peak episodes. The uncertainty of the nodes was 10% between 100 and 150 µg/m3 and 20% between 150 and 200 µg/m3, for Captors, and 10% for >100 µg/m3 for Raptors. Operating both types of nodes up to 5 months did not evidence any clear influence of drifts. The use of these sensors in citizen science can be a useful tool for awareness raising. However, significant data processing efforts are required to ensure high data quality, and thus machine learning strategies are advisable. Relative uncertainties should always be reported when communicating ozone concentration data from sensing nodes., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Self-calibration methods for uncontrolled environments in sensor networks: A reference survey

  • Barceló Ordinas, José María
  • Doudou, Messaoud
  • García Vidal, Jorge
  • Badache, Nadjib
Growing progress in sensor technology has constantly expanded the number and range of low-cost, small, and portable sensors on the market, increasing the number and type of physical phenomena that can be measured with wirelessly connected sensors. Large-scale deployments of wireless sensor networks (WSN) involving hundreds or thousands of devices and limited budgets often constrain the choice of sensing hardware, which generally has reduced accuracy, precision, and reliability. Therefore, it is challenging to achieve good data quality and maintain error-free measurements during the whole system lifetime. Self-calibration or recalibration in ad hoc sensor networks to preserve data quality is essential, yet challenging, for several reasons, such as the existence of random noise and the absence of suitable general models. Calibration performed in the field, without accurate and controlled instrumentation, is said to be in an uncontrolled environment. This paper provides current and fundamental self-calibration approaches and models for wireless sensor networks in uncontrolled environments., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A comparative study of calibration methods for low-cost ozone sensors in IoT platforms

  • Ferrer Cid, Pau
  • Barceló Ordinas, José María
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper shows the result of the calibration process of an Internet of Things platform for the measurement of tropospheric ozone (O 3 ). This platform, formed by 60 nodes, deployed in Italy, Spain, and Austria, consisted of 140 metal–oxide O 3 sensors, 25 electro-chemical O 3 sensors, 25 electro-chemical NO 2 sensors, and 60 temperature and relative humidity sensors. As ozone is a seasonal pollutant, which appears in summer in Europe, the biggest challenge is to calibrate the sensors in a short period of time. In this paper, we compare four calibration methods in the presence of a large dataset for model training and we also study the impact of a limited training dataset on the long-range predictions. We show that the difficulty in calibrating these sensor technologies in a real deployment is mainly due to the bias produced by the different environmental conditions found in the prediction with respect to those found in the data training phase., Peer Reviewed, Postprint (author's final draft)