Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Testing the performance of sensors for ozone pollution monitoring in a citizen science approach

  • Ripoll, Anna
  • Viana, Mar
  • Padrosa, M.
  • Querol, Xavier
  • Minutolo, A.
  • Hou, K. M.
  • Barceló-Ordinas, José María
  • García-Vidal, Jorge
Tropospheric ozone (O3) is an environmental pollutant of growing concern, especially in suburban and rural areas where the density of air quality monitoring stations is not high. In this type of areas citizen science strategies can be useful tools for awareness raising, but sensor technologies must be validated before sensor data are communicated to the public. In this work, the performance under field conditions of two custom-made types of ozone sensing devices, based on metal-oxide and electrochemical sensors, was tested. A large array of 132 metal-oxide (Sensortech MICS 2614) and 11 electrochemical (Alphasense) ozone sensors, built into 44 sensing devices, was co-located at reference stations in Italy (4 stations) and Spain (5). Mean R2 between sensor and reference data was 0.88 (0.78–0.96) and 0.89 (0.73–0.96) for Captor (metal-oxide) and Raptor (electrochemical) nodes. The metal-oxide sensors showed an upper limit (approximately 170 μg/m3) implying that these sensors may be useful to communicate mean ozone concentrations but not peak episodes. The uncertainty of the nodes was 10% between 100 and 150 μg/m3 and 20% between 150 and 200 μg/m3, for Captors, and 10% for >100 μg/m3 for Raptors. Operating both types of nodes up to 5 months did not evidence any clear influence of drifts. The use of these sensors in citizen science can be a useful tool for awareness raising. However, significant data processing efforts are required to ensure high data quality, and thus machine learning strategies are advisable. Relative uncertainties should always be reported when communicating ozone concentration data from sensing nodes. © 2018 The Authors, The authors would like to thank the anonymous reviewers, whose comments improved the manuscript significantly. This work was funded by H2020 project CAPTOR. The authors gratefully acknowledge the collaboration of the staff at the Department of the Environment of the Generalitat de Catalunya and at ARPA Lombardia (Agenzia Regionale per l'Ambiente), who kindly provided support for the deployment of the sensing nodes at reference stations and provided access to the reference data. Support is also acknowledged from AGAUR SGR44, the Agencia Estatal de Investigación (AEI; CGL2017-82093-ERC ), and the Spanish Ministry of Economy, Industry and Competitiveness ( EUIN2017-85799 ). Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Particle-phase concentrations and sources of legacy and novel flame retardants in outdoor and indoor environments across Spain, Concentrations and sources of legacy and novel flame retardants in outdoor and indoor environments

  • Reche, Cristina
  • Viana, Mar
  • Querol, Xavier
  • Corcellas, Cayo
  • Barceló, Damià
  • Eljarrat, Ethel
Levels of particle-phase legacy polybrominated diphenyl ethers (PBDEs), and novel brominated and chlorinated flame retardants, such as decabromodiphenyl ethane (DBDPE) and Dechlorane Plus (DP), were measured in ambient outdoor air, indoor workplace air and indoor dust, in different locations across Spain. PBDE concentrations were generally higher in outdoor ambient air samples than in indoor air, ranging between 1.18 and 28.6 pg m−3, while DP was the main flame retardant (FR) in indoor air (2.90–42.6 pg m−3). A different behavior of legacy versus novel FRs was observed in all the environments and matrices considered, which seemed to indicate a progressive replacement of the former. Although the emission sources could not be fully identified, certain evidences suggested that high outdoor PBDE concentrations could be associated with old goods in landfills and recycling centers, while high indoor DP concentrations were linked to the presence of new electronic devices. A direct impact of land use on outdoor atmospheric DP concentrations was observed, with DP concentrations correlating with high density of buildings within a city. In addition, DP concentrations outdoors correlated with inorganic species with FR properties (e.g., Cr, Cu). Significant differences in the fraction of anti-DP to the total DP (Fanti ratio) were observed between indoor air (PM2.5) and dust (PM10), which could be related with: a) a dependence on particle size, suggesting a higher relative abundance of the anti-isomer in PM10 than in PM2.5, while similar concentrations were recorded for the syn-isomer; b) a higher deposition rate of the anti-isomer compared to the syn-isomer; and/or c) a more accentuated preferential degradation of the anti-isomer linked to artificial light or other agents coexisting in the air. The detectable presence of all the FR families analyzed in indoor air and dust points to the importance of monitoring these compounds in order to minimize human exposure. © 2018, This work was partially funded by the Spanish Ministry of Economy, Industry and Competitiveness (MINEC) and the Agencia Estatal de Investigación (AEI) through project CGL2017-82093-ERC. The authors acknowledge the support from AGAUR SGR41 and SGR1404., Peer reviewed