Skip to main content

SEMIOTIC: INTEGRACION SEMANTICA DE DATOS DE IOT Y SU USO EN LA GESTION ENERGETICA DE LAS SMART GRIDS Y SMART CITIES

TIN2016-78473-C3-1-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Distributed multi-scale calibration of low-cost ozone sensors in wireless sensor networks

  • Barceló Ordinas, José María
  • Ferrer Cid, Pau
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
New advances in sensor technologies and communications in wireless sensor networks have favored the introduction of low-cost sensors for monitoring air quality applications. In this article, we present the results of the European project H2020 CAPTOR, where three testbeds with sensors were deployed to capture tropospheric ozone concentrations. One of the biggest challenges was the calibration of the sensors, as the manufacturer provides them without calibrating. Throughout the paper, we show how short-term calibration using multiple linear regression produces good calibrated data, but instead produces biases in the calculated long-term concentrations. To mitigate the bias, we propose a linear correction based on Kriging estimation of the mean and standard deviation of the long-term ozone concentrations, thus correcting the bias presented by the sensors., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Multisensor data fusion calibration in IoT air pollution platforms

  • Ferrer Cid, Pau
  • Barceló Ordinas, José María
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This article investigates the calibration of low-cost sensors for air pollution. The sensors were deployed on three Internet of Things (IoT) platforms in Spain, Austria, and Italy during the summers of 2017, 2018, and 2019. One of the biggest challenges in the operation of an IoT platform, which has a great impact on the quality of the reported pollution values, is the calibration of the sensors in an uncontrolled environment. This calibration is performed using arrays of sensors that measure cross sensitivities and therefore compensate for both interfering contaminants and environmental conditions. This article investigates how the fusion of data taken by sensor arrays can improve the calibration process. In particular, calibration with sensor arrays, multisensor data fusion calibration with weighted averages, and multisensor data fusion calibration with machine learning models are compared. Calibration is evaluated by combining data from various sensors with linear and nonlinear regression models., This work was supported in part by the NationalSpanish funding under Grant TIN2016-78473-C3-1-R, in part by RegionalProject under Grant 2017SGR-990, in part by EU H2020 CAPTOR Project, inpart by AGAUR SGR44, in part by the Agencia Estatal de Investigación underGrant CGL2017-82093-ERC, and in part by the Spanish Ministry of Economy,Industry and Competitiveness under Grant EUIN2017-85799, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Self-calibration methods for uncontrolled environments in sensor networks: A reference survey

  • Barceló Ordinas, José María
  • Doudou, Messaoud
  • García Vidal, Jorge
  • Badache, Nadjib
Growing progress in sensor technology has constantly expanded the number and range of low-cost, small, and portable sensors on the market, increasing the number and type of physical phenomena that can be measured with wirelessly connected sensors. Large-scale deployments of wireless sensor networks (WSN) involving hundreds or thousands of devices and limited budgets often constrain the choice of sensing hardware, which generally has reduced accuracy, precision, and reliability. Therefore, it is challenging to achieve good data quality and maintain error-free measurements during the whole system lifetime. Self-calibration or recalibration in ad hoc sensor networks to preserve data quality is essential, yet challenging, for several reasons, such as the existence of random noise and the absence of suitable general models. Calibration performed in the field, without accurate and controlled instrumentation, is said to be in an uncontrolled environment. This paper provides current and fundamental self-calibration approaches and models for wireless sensor networks in uncontrolled environments., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A comparative study of calibration methods for low-cost ozone sensors in IoT platforms

  • Ferrer Cid, Pau
  • Barceló Ordinas, José María
  • García Vidal, Jorge
  • Ripoll, Anna
  • Viana, Mar
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., This paper shows the result of the calibration process of an Internet of Things platform for the measurement of tropospheric ozone (O 3 ). This platform, formed by 60 nodes, deployed in Italy, Spain, and Austria, consisted of 140 metal–oxide O 3 sensors, 25 electro-chemical O 3 sensors, 25 electro-chemical NO 2 sensors, and 60 temperature and relative humidity sensors. As ozone is a seasonal pollutant, which appears in summer in Europe, the biggest challenge is to calibrate the sensors in a short period of time. In this paper, we compare four calibration methods in the presence of a large dataset for model training and we also study the impact of a limited training dataset on the long-range predictions. We show that the difficulty in calibrating these sensor technologies in a real deployment is mainly due to the bias produced by the different environmental conditions found in the prediction with respect to those found in the data training phase., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Calibrating low-cost air quality sensors using multiple arrays of sensors

  • Barceló Ordinas, José María
  • García Vidal, Jorge
  • Doudou, Messaoud
  • Rodrigo Muñoz, Santiago
  • Cerezo Llavero, Albert
The remarkable advances in sensing and communication technologies have introduced increasingly low-cost, smart and portable sensors that can be embedded everywhere and play an important role in environmental sensing applications such as air quality monitoring. These user-friendly wireless sensor platforms enable assessment of human exposure to air pollution through observations at high spatial resolution in near-realtime, thus providing new opportunities to simultaneously enhance existing monitoring systems, as well as engage citizens in active environmental monitoring. However, data quality from such platforms is a concern since sensing hardware of such devices is generally characterized by a reduced accuracy, precision, and reliability. Achieving good data quality and maintaining error free measurements during the whole system lifetime is challenging. Over time, sensors become subject to several sources of unknown and uncontrollable faulty data which comprise the accuracy of the measurements and yield observations far from the expected values. This paper investigates calibration of low-cost air quality sensors in a real sensor network deployment. The approach leverages on the availability of sensor arrays in a wireless node to estimate parameters that minimize the calibration error using fusion of data from multiple sensors. The obtained results were encouraging and show the effectiveness of the approach compared to a single sensor calibration., Peer Reviewed, Postprint (author's final draft)