Skip to main content

APROVECHAMIENTO DEL CALOR RESIDUAL A BAJA TEMPERATURA MEDIANTE BOMBAS DE CALOR PARA LA PRODUCCION DE AGUA CALIENTE

BES-2015-074478

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved water to water heat pump design for low-temperature waste heat recovery based on subcooling control, Conception d&apos, une pompe à chaleur eau-eau optimisée pour la récupération de chaleur perdue à basse température basée sur la régulation du sous-refroidissement

  • Hervas-Blasco, Estefania
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Barceló Ruescas, Francisco|||0000-0002-0577-2662
[EN] Traditional heat pumps designs have been optimized for heating applications based on small secondary temperature lifts (around 5K); however, in applications with other characteristic temperature lifts, different design criteria could be required. For instance, transcritical cycles have demonstrated to have a high efficiency for domestic hot water production with high water temperature lifts. This work presents the experimental results of a new water-to-water heat pump composed by the basic heat pump components (condenser, compressor, evaporator, expansion valve and liquid reliever) able to adapt its performance depending on the required water temperature lift. Domestic hot water production from grey water waste heat recovery has been chosen as experimental application to test this heat pump. Results show COP values up to 5.5 at the design condition (20-15 degrees C at the inlet-outlet of the evaporator and 10-60 degrees C at the inlet-outlet of the condenser) and an optimal degree of subcooling of 47 K. (C) 2019 Elsevier Ltd and IIR. All rights reserved., Part of the results of this study were developed in the mainframe of the FP7 European project 'Next Generation of Heat Pumps working with Natural fluids' (NxtHPG). Part of the work presented was carried out by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the project "MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DE CONSUMO CASI NULO"with the reference ENE2017-83665-C2-1-P for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimal design and operation of a central domestic hot water heat pump system for a group of dwellings employing low temperature waste heat as a source

  • Hervas-Blasco, Estefania
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] In this work, a study of an energy recovery system from a low-grade temperature source based on heat pumps for domestic hot water is done. The main components of the system are a pre-heating heat exchanger, an optimized heat pump for domestic hot water production, and a variable-volume storage tank. A model has been developed in TRNSYS to analyse the best configuration and control strategy of the system in order to satisfy the profile demands of 10, 20, and 30 multifamily houses, which are considered as a representative target market for this type of application. From this analysis, the influence of the design/sizing parameters on the system CO2 emissions has been obtained and a design criterium for their minimization has been supplied. Finally, a sensitivity analysis based on different net and heat source temperatures has been done in order to estimate the generalizability of the proposed solution. The obtained results show that this kind of system, with the proper design, sizing, and operation, offers potential CO2 emissions reductions by a factor of almost five compared to a conventional gas boiler system but a bad system selection could reduce this potential benefit up to 25%., Part of the work presented was carried out partially by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500X074478XV0. The authors would also like to acknowledge the Spanish Ministerio de Economia y Competitividad through the project "Maximizacion de la Eficiencia y Minimizacion del Impacto Ambiental de Bombas de Calor para la Descarbonizacion de la Calefaccion/ACS en los Edificios Deconsumo Casi Nulo" with the reference ENE2017-83665-C2-1-P. Finally, this work has been also supported by the Universitat Politecnica de Valencia program ayuda a primeros Proyecto de investigacion through the project with reference SP20180039.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Study of different subcooling control strategies in order to enhance the performance of a heat pump

  • Hervas-Blasco, Estefanía
  • Pitarch, M.
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] The performance of vapor-compression systems working with subcritical refrigerants varies with the degree of subcooling. There is an optimal subcooling that maximizes efficiency. However, it depends on the operating conditions and the control of the system needs to be adapted. Most of the works available in literature are able to operate in optimal conditions only at the design point or if a system is designed to be able to adapt its subcooling, only complex control algorithms that usually are difficult to set and time-costly, are used. This work focuses on the study of the main variables influencing the optimal subcooling and analyzes two different control methodologies from the theoretical point of view. Based on the theoretical study a final control strategy is selected and tested experimentally. The reliability, stability and robustness of the selected strategy are experimentally demonstrated for a wide set of operating conditions. (c) 2018 Elsevier Ltd and IIR. All rights reserved., Part of the work presented was carried by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the project. "MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DECONSUMO CASI NULO" with the reference ENE2017-83665-C2-1-P for the given support.