Skip to main content

APROVECHAMIENTO DEL CALOR RESIDUAL A BAJA TEMPERATURA MEDIANTE BOMBAS DE CALOR PARA LA PRODUCCION DE AGUA CALIENTE

ENE2014-53311-C2-1-P

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Experimental analysis of the refrigerant flow maldistribution in braze plate heat exchangers

  • Álvarez-Piñeiro, Lucas|||0000-0002-9450-2479
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Albaladejo, Paloma
  • Schnabel, Lena
  • Corberán, José M.
[EN] Braze plate heat exchanger (BPHE) are used widely in heating and cooling systems and the efficiency of heat pumps depends critically on the proper performance of them. One of the most common factors affecting the performance of BPHE is the not uniform distribution of the refrigerant. This problem is especially important in the evaporator as the refrigerant enters in it in two phase flow and usually the distribution of liquid and vapor is not uniform over all the channels. This problem is very well known in the literature, and manufacturers have implemented some technical solutions like introducing distributors in the inlet port in order to minimize this effect. Nevertheless, the applied solutions usually are developed only for the nominal conditions and when the BPHE work in other conditions is difficult to know which is going to be its behavior. In this contribution, an experimental analysis of the refrigerant distribution in an evaporator BPHE as a function of the inlet and outlet conditions has been done. The BPHE has been tested working at several inlet conditions (quality) and outlet conditions (superheat) for different temperature difference in the secondary fluid and the refrigerant distribution inside the BPHE has been registered using thermography. From the obtained results, it has been seen that: i) the flow maldistribution is present in most of the test, ii) the quality of the refrigerant at the inlet has an influence in the flow distribution, iii) the superheat has also a very important influence in the refrigerant maldistribution. In fact, the obtained results have shown that conditions working with low superheat show a better refrigerant distribution. Saturation temperature reduction at the evaporation seems to be a result of the refrigerant maldistribution. The COP degradation because of the refrigerant maldistribution is quite important for the performed test. In fact, it is important enough to remove any possible advantage derived for working at high superheat when the temperature lift in the water side is high., Part of the results of this study were developed in the mainframe of the FP7 European project Next Generation of Heat Pumps working with Natural fluids (NxtHPG). The authors would like to acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD, through the project ref-ENE2014-53311-C2-1-P-AR Aprovechamiento del calor residual a baja temperatura mediante bombas de calor para la produccion de agua caliente for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimal sizing of a heat pump booster for sanitary hot water production to maximize benefit for the substitution of gas boilers

  • HERVAS-BLASCO, ESTEFANIA
  • Pitarch, M.
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] Heat recovery from water sources such as sewage water or condensation loops at low temperatures (usually between 10 and 30 °C) is becoming very valuable. Heat pumps are a potential technology able to overcome the high water temperature lift of the Sanitary Hot Water (SHW) application (usually from 10 °C to 60 °C with COPs up to 6). This paper presents a model to find the optimal size of a system (heat pump and recovery heat exchanger) based on water sources to produce SHW compared to the conventional production with a gas boiler in order to maximize the benefit. The model includes a thermal and economic analysis for a base case and analyzes the influence of a wide set of parameters which could have a significant influence. Even the uncertainties involved, results point out considerable benefits from this substitution based on the capacity of the system. Thus, demonstrating the importance of the optimal size analysis before an investment is done., Part of the work presented was carried by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500X074478XV0. Part of the work presented was carried by Miguel Pitarch-Mocholi with the financial support of a PhD scholarship from the Universitat Politecnica de Valencia. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the project ref-ENE2014-53311-C2-1-P-AR "Aprovechamiento del calor residual a baja temperatura mediante bombas de calor para la produccion de agua caliente" for the given support
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved water to water heat pump design for low-temperature waste heat recovery based on subcooling control, Conception d&apos, une pompe à chaleur eau-eau optimisée pour la récupération de chaleur perdue à basse température basée sur la régulation du sous-refroidissement

  • Hervas-Blasco, Estefania
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Barceló Ruescas, Francisco|||0000-0002-0577-2662
[EN] Traditional heat pumps designs have been optimized for heating applications based on small secondary temperature lifts (around 5K); however, in applications with other characteristic temperature lifts, different design criteria could be required. For instance, transcritical cycles have demonstrated to have a high efficiency for domestic hot water production with high water temperature lifts. This work presents the experimental results of a new water-to-water heat pump composed by the basic heat pump components (condenser, compressor, evaporator, expansion valve and liquid reliever) able to adapt its performance depending on the required water temperature lift. Domestic hot water production from grey water waste heat recovery has been chosen as experimental application to test this heat pump. Results show COP values up to 5.5 at the design condition (20-15 degrees C at the inlet-outlet of the evaporator and 10-60 degrees C at the inlet-outlet of the condenser) and an optimal degree of subcooling of 47 K. (C) 2019 Elsevier Ltd and IIR. All rights reserved., Part of the results of this study were developed in the mainframe of the FP7 European project 'Next Generation of Heat Pumps working with Natural fluids' (NxtHPG). Part of the work presented was carried out by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the project "MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DE CONSUMO CASI NULO"with the reference ENE2017-83665-C2-1-P for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparison of different modeling approaches for minichannel evaporators under dehumidification

  • Hassan, Abdelrahman|||0000-0001-9063-9569
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
  • Martinez-Ballester, Santiago
[EN] This paper firstly presents a comprehensive minichannel evaporator model (MCHX-1D-MB) based on fin theory coupled with the moving boundary technique along fin height. To validate the presented model, experimental data for R-134a and R-744 (CO2) minichannel evaporators were used. The proposed model successfully predicted the cooling capacity of R-134a and CO2 evaporators with mean absolute error values of +/- 1.8 and +/- 4.3%, respectively. Regarding the outlet air temperature, the mean absolute errors in the estimated results were +/- 0.43 and +/- 0.9 degrees C for R-134a and CO2 evaporators, respectively. Finally, to evaluate the impact of widely used assumption of cut fin on the air-side performance of minichannel evaporators, another model was developed (MCHX-1D-CF). The comparative study revealed that the most remarkable deviations between the two models appear when the evaporator operates under partially wet conditions, which were up to approximate to 12% in the latent heat transfer rate., The authors would like to gratefully acknowledge the financial support from the Spanish Ministry of Economy and Finance to project number ENE2014-53311-C2-1-P.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimal design and operation of a central domestic hot water heat pump system for a group of dwellings employing low temperature waste heat as a source

  • Hervas-Blasco, Estefania
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] In this work, a study of an energy recovery system from a low-grade temperature source based on heat pumps for domestic hot water is done. The main components of the system are a pre-heating heat exchanger, an optimized heat pump for domestic hot water production, and a variable-volume storage tank. A model has been developed in TRNSYS to analyse the best configuration and control strategy of the system in order to satisfy the profile demands of 10, 20, and 30 multifamily houses, which are considered as a representative target market for this type of application. From this analysis, the influence of the design/sizing parameters on the system CO2 emissions has been obtained and a design criterium for their minimization has been supplied. Finally, a sensitivity analysis based on different net and heat source temperatures has been done in order to estimate the generalizability of the proposed solution. The obtained results show that this kind of system, with the proper design, sizing, and operation, offers potential CO2 emissions reductions by a factor of almost five compared to a conventional gas boiler system but a bad system selection could reduce this potential benefit up to 25%., Part of the work presented was carried out partially by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500X074478XV0. The authors would also like to acknowledge the Spanish Ministerio de Economia y Competitividad through the project "Maximizacion de la Eficiencia y Minimizacion del Impacto Ambiental de Bombas de Calor para la Descarbonizacion de la Calefaccion/ACS en los Edificios Deconsumo Casi Nulo" with the reference ENE2017-83665-C2-1-P. Finally, this work has been also supported by the Universitat Politecnica de Valencia program ayuda a primeros Proyecto de investigacion through the project with reference SP20180039.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of optimal subcooling in subcritical heat pump systems

  • Pitarch, Miquel
  • Hervas-Blasco, Estefanía
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] The performance of a transcritical cycle is highly dependent on the rejection pressure. The optimal rejection pressure depends mainly on the inlet and outlet temperatures at the heat sink (secondary fluid). For the subcritical cycles, recent studies have demonstrated that the performance of these systems depends significantly on the degree of subcooling and its optimal value varies depending on the application. This paper presents a general methodology to calculate the optimal subcooling depending on the boundary conditions. The refrigerants R290, R134a, R1234yf and R32 are analyzed. Exergy analysis is used in order to see the subcooling effect at condenser and expansion valve independently. The optimal subcooling strongly depends on the temperature lift at the secondary fluid, and it is found when two pinch points are given in the condenser, one at the condenser outlet and another one inside the condenser (at the refrigerant dew point)., Part of the results of this study were developed in the mainframe of the FP7 European project "Next Generation of Heat Pumps working with Natural fluids" (NxtHPG). Part of the work presented was carried by Miguel Pitarch-Mocholi with the financial support of the PhD scholarship from the Universitat Politecnica de Valencia. The authors would like to acknowledge the Spanish "MINISTERIO DE ECONOMIA Y COMPETITIVIDAD", through the project ref-ENE2014-53311-C2-1-P-AR "Aprovechamiento del calor residual a baja temperatura mediante bombas de calor para la produccion de agua caliente" for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Study of different subcooling control strategies in order to enhance the performance of a heat pump

  • Hervas-Blasco, Estefanía
  • Pitarch, M.
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] The performance of vapor-compression systems working with subcritical refrigerants varies with the degree of subcooling. There is an optimal subcooling that maximizes efficiency. However, it depends on the operating conditions and the control of the system needs to be adapted. Most of the works available in literature are able to operate in optimal conditions only at the design point or if a system is designed to be able to adapt its subcooling, only complex control algorithms that usually are difficult to set and time-costly, are used. This work focuses on the study of the main variables influencing the optimal subcooling and analyzes two different control methodologies from the theoretical point of view. Based on the theoretical study a final control strategy is selected and tested experimentally. The reliability, stability and robustness of the selected strategy are experimentally demonstrated for a wide set of operating conditions. (c) 2018 Elsevier Ltd and IIR. All rights reserved., Part of the work presented was carried by Estefania Hervas Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the project. "MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DECONSUMO CASI NULO" with the reference ENE2017-83665-C2-1-P for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Exergy analysis on a heat pump working between a heat sink and a heat source of finite heat capacity rate

  • Pitarch, Miguel
  • Hervás-Blasco, Estefanía
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] The optimum performance of a pure subcritical refrigeration cycle depends significantly on the temperature lift of the heat source and sink. Therefore, the maximization of the system efficiency has to be linked to them. This paper shows an exergy analysis of each heat pump component (condenser, evaporator, expansion valve and compressor) considering that the heat source and sink are not at constant temperature. The performed study shows the components with more possibilities for improvement. Based on this analysis, the optimization of cycle parameters like subcooling and superheat as a function of the external conditions have been done. In addition, this work has demonstrated that the components having a higher influence in the system irreversibility's depends significantly on the temperature lift of the secondary fluids. Finally, the obtained results show potentials improvements of the efficiency up to 23% if the system is able to operate in the optimal subcooling and superheat., Part of the results of this study were developed in the mainframe of the FP7 European project 'Next Generation of Heat Pumps workingwith natural fluids' (NxtHPG). Part of the work presented was carried by Miquel Pitarch with the financial support of a PhD scholarship from the Universitat Politecnica de Valencia. Part of the work presented was carried by Estefania Hervas-Blasco with the financial support of a Ph.D. scholarship from the Spanish government SFPI1500X074478XV. The authors would like also to acknowledge the Spanish 'MINISTERIO DE ECONOMIA Y COMPETITIVIDAD', through the Project ENE2017-83665-C2-1-P, "Maximizacion de la Eficiencia y Minimizacion del Impacto Ambiental de Bombas de Calor para la descarbonizacion de la calefaccion/ACS en los proximos edificios de consumo energetico casi nulo" for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of different heat pump systems for sanitary hot water production using natural refrigerants

  • Pitarch, Miguel
  • Corberán, José M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] Heat pumps that work with a high degree of subcooling in subcritical systems have shown a significant margin of improvement when working with sanitary hot water applications. Recently, two different approaches to overcome the high degree of subcooling have been presented in the literature: with a subcooler (separate from the condenser) and by making all the subcooling in the condenser. In this paper, a comparative evaluation between both alternatives is presented, and the obtained results are compared with a representative solution already available on the market using natural refrigerants for this application. The results of this analysis have shown that in a system with subcooling in the condenser, it is possible to obtain a COP comparable to that of transcritical CO2 heat pump water heaters. Furthermore, the system with subcooling has been demonstrated experimentally as being capable of producing water up to 90ºC and has shown a COP up to 20% higher than some CO2 commercial products (catalogue data reference)., This work has been developed in the Seventh Framework Program of the European Union by the project, Next Generation of Heat Pump Technologies (NEXTGHP), grant agreement 307169. The authors thank the support given. Part of the work presented was carried by Miquel Pitarch-Mocholí with the financial support of a PhD scholarship from the Universitat Politècnica de València. The authors would like also to acknowledge the Spanish ‘MINISTERIO DE ECONOMIA Y COMPETITIVIDAD’, through the project ref-ENE2014-53311-C2-1-P-AR ‘‘Aprovechamiento del calor residual a baja temperatura mediante bombas de calor para la produccion de agua caliente” for the given support