ESTUDIO DE LAS PROPIEDADES MODALES DE CAPAS ELASTICAS Y SU REPERCUSION EN LA TRANSMISION ACUSTICA EN EDIFICIOS

BIA2009-11753

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2009
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

ESTUDIO DE LAS PROPIEDADES MODALES DE CAPAS ELASTICAS Y SU REPERCUSION EN LA TRANSMISION ACUSTICA EN EDIFICIOS

BIA2009-11753

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2009
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Accuracy and robustness of four basic single degree of freedom methods for determining the modal parameters of non-lightly damped systems

  • Anthony, David K.
  • Simón, Francisco
18 páginas, 10 figuras, 4 tablas, An adequate measurement strategy (the combination of measurement method, response parameter, and where applicable, damping estimator) should be used for accurate determination of the natural frequency and damping of non-lightly damped single degree of freedom (SDOF) systems, otherwise, significant measurement bias errors can exist. The accuracy of four commonly used methods is studied and the measurement strategies that are exact are identified. This can depend on the damping mechanism, which if not known can be gleaned from patterns of bias errors between frequency estimations from different strategies. Since in practice a SDOF system rarely exists, or as SDOF techniques are knowingly applied to multiple degree of freedom (MDOF) systems, the robustness of the strategies in the presence of a secondary mode is studied, and the more robust (and therefore preferable) strategies are identified. The measurement method based on the real spectral part is advantageous as it evaluates the damping exactly and is independent of the damping mechanism, in addition the natural frequency obtained is independent of the response parameter. However, this method is not a relatively robust one, and is also sensitive to phase changes accrued during measurements. © 2012 Elsevier Ltd. All rights reserved., The reported work has been supported in part by a research contract (I3P-2003) co-financed by the Consejo Superior de Investigaciones Científicas and the European Union, and a research grant from the Spanish Ministerio de Ciencia e Innovación (BIA2009-11753). The authors would like to thank Jesús Juan (Laboratorio de Estadística, Universidad Politécnica de Madrid [UPM]) for his help and advice in the preparation of this work.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Improving the accuracy of the n-dB method for determining damping of non-lightly damped systems

  • Anthony, David K.
  • Simón, Francisco
7 páginas, 6 figuras, Damping measurements using the spectral magnitude remain popular and are studied here for non-lightly damped systems using the variable bandwidth n-dB method, which is advantageous for non-lightly damped systems. The most commonly used estimator (based on normalised bandwidth) provides significant errors for non-lightly damped systems. An existing more accurate method (using the squares of the frequencies used in the former method) is exact for hysteretic damping, but still provides significant error for viscous damping. Improved estimators are developed in order to correct either exactly, or to insignificant errors, measurements taken with existing estimators. Neither further data nor the individual frequencies are required; the previously calculated damping values are corrected. The application of the improved estimators is dependent upon the existing estimator used and the damping type; however a strategy is suggested to reduce errors if the latter is unknown. © 2009 Elsevier Ltd. All rights reserved., The first author performed this work on an invited stay at the named institution. This work has been supported in part by a re- search grant from the Spanish Ministerio de Ciencia e Innovación (BIA2009-11753). The authors would like to thank the referees for their useful comments and suggestions.