Skip to main content

TECNOLOGIAS PARA LA INTEGRACION EN LA RED DE ENERGIAS RENOVABLES: ELECTRONICA DE POTENCIA, ALMACENAMIENTO, GESTION ENERGETICA E INTERACCION CON LA RED

DPI2013-42853-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

High frequency power transformers with foil windings: maximum interleaving and optimal design

  • Barrios Rípodas, Ernesto
  • Urtasun Erburu, Andoni
  • Ursúa Rubio, Alfredo
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
Foil conductors and primary and secondary interleaving are normally used to minimize winding losses in high frequency transformers used for high-current power applications. However, winding interleaving complicates the transformer assembly, since taps are required to connect the winding sections, and also complicates the transformer design, since it introduces a new tradeoff between minimizing losses and reducing the construction difficulty. This paper presents a novel interleaving technique, named maximum interleaving, that makes it possible to minimize the winding losses as well as the construction difficulty. An analytical design methodology is also proposed in order to obtain free cooled transformers with a high efficiency, low volume and, therefore, a high power density. For the purpose of evaluating the advantages of the proposed maximum interleaving technique, the methodology is applied to design a transformer positioned in the 5 kW 50 kHz intermediate high frequency resonant stage of a commercial PV inverter. The proposed design achieves a transformer power density of 28 W/cm3 with an efficiency of 99.8%. Finally, a prototype of the maximum-interleaved transformer is assembled and validated satisfactorily through experimental tests., This work was supported in part by the Spanish Ministry of Economy and Competitiveness under Grants DPI2010-21671-C02-01 and DPI2013-42853-R and by the Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Fuzzy logic-based energy management system design for residential grid-connected microgrids

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
  • Guinjoan Gispert, Francesc
This paper presents the design of a low complexity fuzzy logic controller of only 25-rules to be embedded in an energy management system for a residential grid-connected microgrid including renewable energy sources and storage capability. The system assumes that neither the renewable generation nor the load demand is controllable. The main goal of the design is to minimize the grid power profile fluctuations while keeping the battery state of charge within secure limits. Instead of using forecasting-based methods, the proposed approach use both the microgrid energy rate-of-change and the battery state of charge to increase, decrease, or maintain the power delivered/absorbed by the mains. The controller design parameters (membership functions and rule-base) are adjusted to optimize a pre-defined set of quality criteria of the microgrid behavior. A comparison with other proposals seeking the same goal is presented at simulation level, whereas the features of the proposed design are experimentally tested on a real residential microgrid implemented at the Public University of Navarre., This work was supported in part by the Secretaría Nacional de Educación Superior, Ciencia, Tecnología e Innovación SENESCYT and the Instituto de Fomento al Talento Humano del Ecuador under Grant 2013-AR2Q4081; in part by the Government of Navarra and the European Regional Development Fund under the Microgrids in Navarra: Design, Development, and Implementation Project; in part by the Spanish Ministry of Economy and Competitiveness under Grant DPI2013-42853-R; in part by the European Union under Project FP7-308468; in part by PVCROPS—Photovoltaic Cost Reduction, Reliability, Operational Performance, Prediction, and Simulation under Grant RUE CSD2009-00046; in part by the Consolider-Ingenio 2010 Programme; in part by the Spanish Ministry of Science and Innovation; and in part by the Spanish Ministry of Economy and Knowledge under Grant DPI2013-41224-P and Grant DPI2012-31580. Paper no. TSG-00712-2015.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

State-of-charge-based droop control for stand-alone AC supply systems with distributed energy storage

  • Urtasun Erburu, Andoni
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
The droop method is an advantageous technique for stand-alone AC supply systems, allowing for power sharing among various inverters with no need for communication cables. However, in stand-alone systems with multiple distributed energy storage units, the conventional droop methods are unable to control the storage unit state-of-charge (SOC) in order to change simultaneously. Existing techniques endeavor to solve this problem by changing the slope of the P – f curve however this solution compromises the power response performance. As an alternative, this paper proposes a new SOC-based droop control, whereby the P – f curve is shifted either upwards or downwards according to the battery SOC. The proposed technique makes it possible to select the time constant for the battery SOC convergence and, at the same time, to optimize the power response performance. The paper also shows how the SOC changes when the ratios between the battery capacity and the inverter rated power are different and how the proposed technique can limit the SOC imbalance. Simulation and experimental results corroborate the theoretical analysis., This work was supported in part by the Spanish Ministry of Economy and Competitiveness under Grant DPI2013-42853-R, and by the Public University of Navarre through a doctoral scholarship.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Analytical design methodology for Litz-wired high-frequency power transformers

  • Barrios Rípodas, Ernesto
  • Ursúa Rubio, Alfredo
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
In the last quarter of a century, high-frequency (HF) transformer design has been one of the major concerns to power electronics designers in order to increase converter power densities and efficiencies. Conventional design methodologies are based on iterative processes and rules of thumb founded more on expertise than on theoretical developments. This paper presents an analytical design methodology for litz-wired HF power transformers that provides a deep insight into the transformer design problem making it a powerful tool for converter designers. The most suitable models for the calculation of core and winding losses and the transformer thermal resistance are first selected and then validated with a 5-kW 50-kHz commercial transformer for a photovoltaic application. Based on these models, the design methodology is finally proposed, reducing the design issue to directly solve a five-variable nonlinear optimization problem. The methodology is illustrated with a detailed design in terms of magnetic material, core geometry, and primary and secondary litz-wire sizing. The optimal design achieves a 46.5% power density increase and a higher efficiency of 99.70% when compared with the commercial one., This work was supported in part by the Spanish Ministry of Economy and Competitiveness under Grant DPI2010-21671-C02-01 and Grant DPI2013-42853-R, in part by the Public University of Navarra, and in part by Ingeteam Power Technology.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

A comprehensive model for lithium-ion batteries: from the physical principles to an electrical model

  • Berrueta Irigoyen, Alberto
  • Urtasun Erburu, Andoni
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
The growing interest in e-mobility and the increasing installation of renewable energy-based systems are leading to rapid improvements in lithium-ion batteries. In this context, battery manufacturers and engineers require advanced models in order to study battery performance accurately. A number of Li-ion battery models are based on the representation of physical phenomena by electrochemical equations. Although providing detailed physics-based information, these models cannot take into account all the phenomena for a whole battery, given the high complexity of the equations. Other models are based on equivalent circuits and are easier to design and use. However, they fail to relate these circuit parameters to physical properties. In order to take the best of both modeling techniques, we propose an equivalent circuit model which keeps a straight correlation between its parameters and the battery electrochemical principles. Consequently, this model has the required simplicity to be used in the simulation of a whole battery, while providing the depth of detail needed to identify physical phenomena. Moreover, due to its high accuracy, it can be used in a wide range of environments, as shown in the experimental validations carried out in the final section of this paper., The authors acknowledge the support of the Spanish State Research Agency (AEI) and FEDER UE under grants DPI2013 42853 R, DPI2016 80641 R and DPI2016 80642 R; of Government of Navarra through research project PI038 INTEGRA-RENOVABLES; and the FPU Program of the Spanish Ministry of Education, Culture and Sport (FPU13/00542).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Low complexity energy management strategy for grid profile smoothing of a residential grid-connected microgrid using generation and demand forecasting

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Guinjoan Gispert, Francesc
  • Marroyo Palomo, Luis
  • Sanchis Gúrpide, Pablo
This paper presents the design of an energy management strategy based on a low complexity Fuzzy Logic Control (FLC) for grid power profile smoothing of a residential grid-connected microgrid including Renewable Energy Sources (RES) and battery Energy Storage System (ESS). The proposed energy management strategy uses generation and demand forecasting to anticipate the future behavior of the microgrid. Accordingly to the microgrid power forecast error and the Battery State-of-Charge (SOC) the proposed strategy performs the suitable control of the grid power. A simulation comparison with previous energy management strategies highlights the advantages of the proposed work minimizing fluctuations and power peaks in the power profile exchanged with the grid while keeping the energy stored in the battery between secure limits. Finally, the experimental validation in a real residential microgrid implemented at Public University of Navarre (UPNA, Spain) demonstrates the proper operation of the proposed strategy achieving a smooth grid power profile and a battery SOC center close to the 75% of the rated battery capacity., This work is part of the project 2016-PIC-044 from the Universidad de las Fuerzas Armadas ESPE. This work was partially supported by the Spanish State Research Agency (AEI) and FEDER-UE under grants: DPI2015-67292, DPI2013-41224-P, DPI2013-42853-R and DPI2016-80641-R.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Methodology for sizing stand-alone hybrid systems: a case study of a traffic control system

  • San Martín Biurrun, Idoia
  • Berrueta Irigoyen, Alberto
  • Sanchis Gúrpide, Pablo
  • Ursúa Rubio, Alfredo
This paper proposes a methodology for sizing stand-alone hybrid photovoltaic-wind power generation systems. This methodology makes it possible to optimise the overall performance of the stand-alone system components, based on the premise of guaranteeing the power supply throughout the useful life of the installation at a minimum cost. The sizing is performed in two stages. Firstly, the components of the wind and photovoltaic power generation subsystem are obtained and, secondly, the size of the storage subsystem is determined. For the storage subsystem sizing, account is taken of the variation in efficiency according to the operating point and also the deterioration of the subsystem due to aging and, therefore, the loss of available energy during the useful life of the installation. This methodology is applied to a stand-alone traffic control system located on a secondary road in the Autonomous Community of Valencia (Spain). This system comprises wind and photovoltaic power generation components, a lithium battery bank and various traffic management components. Finally, an analysis of the proposed sizing is made. Satisfactory results are obtained, showing how the proposed methodology makes it possible to optimise the sizing of stand-alone systems with regard to the size of its components, cost and operation., This work has been supported by the Spanish State Research Agency (AEI) and FEDER-UE under grant DPI2013-42853-R, DPI2016-80642-R and DPI2016-80641-R; and by the Government of Navarre under project PIO38 INTEGRA-RENOVABLES.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Frequency-based energy management strategy for stand-alone systems with distributed battery storage

  • Urtasun Erburu, Andoni
  • Barrios Rípodas, Ernesto
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
Distributed generation is an attractive solution for stand-alone AC supply systems. In such systems, the installation of two or more energy-storage units is recommended for system redundancy and may also be required when there is a consumption increase following installation. However, energy management with multiple energy-storage units has been but vaguely analyzed in the literature and the few studies made are based on communication cables with a central supervisor. This paper proposes an energy management strategy for a multiple-battery system which makes it possible to avoid the use of communication cables, rendering the system more cost-effective and reliable. The strategy modifies the conventional droop method so that the power becomes unbalanced, allowing for the regulation of one or more battery voltages or currents, as required. Furthermore, whenever the frequency is high, the PV inverters reduce their power in order to prevent the battery from overcharge or high charging currents. On the other hand, whenever the frequency is low, then either the non-critical loads are regulated or the system stops in order to prevent the battery from over-discharge or high discharging currents. Simulation and experimental validation are performed for a system with two battery inverters, two PV inverters and a number of loads., This work was supported in part by the Spanish Ministry of Economy and Competitiveness under Grant DPI2013-42853-R, and by the Public University of Navarre through a doctoral scholarship.