Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Efficacy of a brief psychological intervention for adolescents with recent suicide attempt, A randomized clinical trial

  • García-Fernández, Ainoa|||0000-0002-4874-0353
  • Couce-Sánchez, Manuel|||0000-0002-2183-3824
  • Andreo Jover, Jorge|||0000-0002-6703-8017
  • Ayad-Ahmed, Wala|||0000-0002-0786-0076
  • Bobes-Bascarán, Maria T.|||0000-0002-5279-504X
  • Botí, M.|||0000-0003-2963-6929
  • Canal-Rivero, Manuel|||0000-0002-5818-5103
  • Cebrià, Ana Isabel|||0000-0002-2632-8130
  • Crespo-Facorro, Benedicto|||0000-0003-0033-7132
  • Díaz-Marsá, Marina|||0000-0003-1364-3163
  • Fernández-Rodrigues, Verónica|||0000-0003-0397-513X
  • Gómez Vallejo, Sandra|||0000-0003-0963-6585
  • González-Pinto, Ana|||0000-0002-2568-5179
  • Grande, Iria|||0000-0002-0137-0666
  • Iglesias Gutiérrez, Noelia|||0000-0002-8684-8082
  • Jiménez-Treviño, Luis|||0000-0002-9551-8587
  • López-Pena, Purificación
  • Palao, Diego|||0000-0002-3323-6568
  • Palao Tarrero, Ángela|||0000-0003-2717-5807
  • Pedrola-Pons, Anna|||0009-0007-1641-5541
  • Ruiz-Veguilla, Miguel|||0000-0002-5790-7346
  • Suárez-Soto, Elizabeth|||0000-0001-7599-0078
  • Torre-Luque, Alejandro de la|||0000-0003-0595-6127
  • Zorrilla, Iñaki|||0000-0001-6444-8208
  • Pérez Solà, Víctor|||0000-0002-5825-2337
  • Sáiz, Pilar A.|||0000-0002-5705-4523
Adolescents are at a heightened risk of suicide reattempts following hospital discharge, but few evidence-based interventions exist. This study evaluated the efficacy of the self-awareness of mental health (SAM) program combined with treatment as usual (TAU) versus TAU alone in reducing reattempts among high-risk adolescents. A randomized clinical trial was conducted across nine Spanish hospitals (January 2021-March 2024) with 261 adolescents (12-17 years) who had attempted suicide within the last 15 days. Participants were assigned to SAM + TAU (n=128) or TAU (n=133), with 12-month follow-up. The primary outcome was suicide reattempts within 12 months; secondary analyses examined time to reattempt and associated risk factors. After 12-months, no significant differences were found in reattempt rates [22.6% (SAM) versus 27.8% (TAU); OR=0.610, 95%CI (0.321-1.151), p=0.127] or time to reattempt [HR=0.606, 95%CI (0.390-1.021), p=0.060]. In SAM, attentional impulsivity emerged as a significant risk factor [HR=1.126, 95% CI (1.004-1.263), p=0.043], while nonplanning impulsivity was protective [HR=0.878, 95%CI (0.814-0.948), p<0.001]. In TAU, increased suicide risk was linked to suicidal intentionality [HR=1.341, 95%CI (1.009-1.782), p=0.044] and more prior attempts [HR=1.230, 95%CI (1.039-1.457), p=0.016]. Conversely, fewer psychiatric diagnoses emerged as a protective factor [HR=0.821, 95%CI (0.677-0.996), p=0.045]. While no significant differences were found between groups, SAM identified important psychological factors influencing suicide risk. These findings provide a foundation for targeted interventions to prevent reattempts in adolescents.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Suicidal ideation with and without intention to act, A transdiagnostic network analysis on the interplay between psychopathology, impulsivity, and childhood maltreatment

  • De Prisco, Michele|||0000-0002-2032-1181
  • Roberto Herrero, Natalia|||0000-0002-5391-2711
  • Andreo Jover, Jorge|||0000-0002-6703-8017
  • Ayad-Ahmed, Wala|||0000-0002-0786-0076
  • Bobes-Bascarán, Maria T.|||0000-0002-5279-504X
  • Canal-Rivero, Manuel|||0000-0002-5818-5103
  • Canosa García, Irene
  • Cebrià, Ana Isabel|||0000-0002-2632-8130
  • Crespo-Facorro, Benedicto|||0000-0003-0033-7132
  • Curto-Ramos, Javier
  • Díaz-Marsá, Marina|||0000-0003-1364-3163
  • Torre-Luque, Alejandro de la|||0000-0003-0595-6127
  • Elices, M.|||0000-0002-7034-4242
  • Jiménez-Treviño, Luis|||0000-0002-9551-8587
  • Palao Tarrero, Ángela|||0000-0003-2717-5807
  • Palao, Diego|||0000-0002-3323-6568
  • Pemau, Andrés|||0000-0002-5835-507X
  • Lopez-Pena, Maria Purificacion
  • Ruiz Veguilla, Miguel
  • Sáiz, Pilar A.|||0000-0002-5705-4523
  • Suárez-Soto, Elizabeth|||0000-0001-7599-0078
  • Courtet, Philippe|||0000-0002-6519-8586
  • Vieta, Eduard|||0000-0002-0548-0053
  • Grande, Iria|||0000-0002-0137-0666
  • Pérez Solà, Víctor|||0000-0002-5825-2337
Suicide represents a significant public health concern. Suicide prevention strategies are shifting toward transdiagnostic perspectives examining interrelated risk factors, but their interrelationships remain unclear. This study investigated relationships between psychopathological dimensions, impulsivity, and childhood maltreatment in individuals with suicidal ideation (SI), comparing those with versus without intention to act using network analysis. Data were obtained from the Suicide Prevention and Intervention Study project. Participants were categorized into two groups based on their intention to act according to the Columbia Suicide Severity Rating Scale. Psychological symptoms, impulsivity traits, and childhood maltreatment were assessed. Network analysis was performed, and centrality measures were computed. A total of 1,265 individuals were categorized into the SI without intention to act (n = 345) and SI with intention to act (n = 920) groups. The former showed lower depression and hostility scores, and lower prevalence of major depressive and anxiety disorders. Network analyses revealed that in the SI without intention to act group, obsessive-compulsive symptoms were central, connecting to depression and anxiety, while negatively correlating with non-planning impulsivity. In contrast, the SI with intention to act group showed a more densely interconnected network where emotional abuse served as a bridge between childhood maltreatment and other psychopathological dimensions. This study identifies symptom interaction patterns between individuals with SI without and with intention to act. Understanding these relationships may improve suicide risk assessment and inform personalized interventions, potentially reducing the transition from ideation to action. Trauma-focused approaches addressing emotional abuse may be especially relevant for individuals at high risk.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterisation of SiC radiation detector technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
To cope with environments with high levels of radiation, non-silicon semiconductors such as silicon carbide detectors are being proposed for instrumentation. 4H-SiC diodes for radiation detection have been fabricated in the IMB-CNM Clean Room, for which different strategies to define the electrical contact of the implants had been implemented, in an attempt to optimise the technology for, e.g., medical applications or low energy radiation detection, as the material choice can affect the sensitivity of the device. Among these technologies, it is included an epitaxially-grown graphene layer as part of the electrical contact. In this paper, a selection of four configurations of the IMB-CNM SiC diodes are characterised in terms of radiation detector response. Photodiode performance under 20 keV X-rays irradiation in the XALOC beam line at ALBA Synchrotron is presented. Over-responses in the range of 12-19% linked to the interaction of the radiation with the metallic layers are observed. A good uniformity response as well as a good linearity at 0~V bias is reported, even in the under-depleted devices. This work exemplifies the good performance of SiC detectors fabricated at IMB-CNM specifically for low-energy X ray characterization at high X-ray intensities., This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023- 001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Evaluation of the two-voltage method for parallel-plate ionization chambers irradiated with pulsed beams

  • Paz-Martín, José
  • Schüller, Andreas
  • Bourgouin, Alexandra
  • Gago-Arias, Araceli
  • González-Castaño, Diego M,
  • Gómez-Fernández, Nicolás
  • Pardo-Montero, Juan
  • Gómez, Faustino
Air-vented ionization chambers exposed to clinical radiation beams may suffer from recombination during the drift of the charge carriers towards the electrodes. Thus, dosimetry protocols recommend the use of a correction factor, usually denominated saturation factor ( ksat$k_{\rm sat}$ ), to correct the ionization chamber readout for the incomplete collection of charge. The two-voltage method (TVM) is the recommended methodology for the calculation of the saturation factor, however, it is based on the early Boag model, which only takes into account the presence of positive and negative ions in the ionization chamber and does not account for the electric field screening or the free electron contribution to the signal., Jose Paz-Martín has received a predoctoral research contract from the Xunta de Galicia regional govern-ment. Juan Pardo-Montero acknowledges the support of Xunta de Galicia, Axencia Galega de Innovación (grant IN607D2022). This work has been developed under the project 18HLT04 UHDpulse with funding from the EMPIR innovation program. This work has received funding from ‘la Caixa’ Foundation under the grant agreement HR23-00718 (‘Dosimetry monitor for FLASH therapy’ project) and from grant PLEC2022-009476 funded by MCIN/AEI/10.13039/501100011033 and by the ‘European Union NextGenerationEU/PRTR’. The authors thank Christoph Makowski for the electron linear accelerator maintenance during the measurement campaign, Olaf Tappe for the machining work, and Thomas Hackel for the alanine measurements., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions

  • Jiménez-Ramos, M. Carmen
  • Torres-Múñoz, Carmen
  • García-López, Javier
  • Barroso-Molina, Diego
  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications., This work has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse. It has also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718) M. Carmen Jim´enez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4” with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A Tri-Culture Heart-on-a-Chip Platform With iPSC-Derived Cardiac Cells for Predictive Cardiotoxicity Testing

  • Tadevosyan, Karine
  • Yeste, Jose
  • Alvarez, Mar
  • Marrero, Denise
  • Casado-Medina, Laura
  • Richaud-Patin, Yvonne
  • García-Iglesias, Olalla
  • Litowczenko, Jagoda
  • Garcia, Alba Morillas
  • Guimerà, Anton
  • Illa, Xavi
  • Villa, Rosa
  • Raya, Angel
Drug development is hindered by high attrition rates, with clinical trial failures accounting for 90% of unsuccessful candidates and 60% of R&D costs, often due to unanticipated cardiotoxicity. Existing models lack physiological relevance, particularly the vascular component critical for drug distribution and cardioprotection. To address this, we developed a heart-on-a-chip (HoC) platform integrating human induced pluripotent stem cell (iPSC)-derived cardiomyocytes, cardiac fibroblasts, and endothelial cells from a single cell line, ensuring genetic uniformity and native-like cell-cell interactions. The tri-culture system maintained >90% cell viability under perfusion for 7 days and exhibited functional maturity, as demonstrated by expected chronotropic responses to the β-agonist isoproterenol. Crucially, the inclusion of endothelial cells mitigated doxorubicin-induced cardiotoxicity, a protective effect absent in conventional models, highlighting the endothelial layer's role in replicating in vivo drug responses. By combining physiological mimicry with scalability, this HoC platform offers a transformative tool for improving preclinical cardiotoxicity assessment and reducing reliance on animal models., The authors are indebted to the Histology and Bioimaging Platforms of IDIBELL Scientific and Technical Services and to the Micro NanoTechnology Unit U8 (IMB-CNM, CSIC), which is ascribed to the NANBIOSIS ICTS of CIBER-BBN, for their support. This research was funded by the Spanish Ministry of Science, Innovation, and Universities-MICIU (grants PID2021-123925OB-I00, PDC2023 145822 I00, and PID2024-15802908OB-I00), AGAUR (2021-SGR-974), Fundació La Marató de TV3 (202331-30), Fundació Obra Social la Caixa LCF/PR/HR23/52430011), and CERCA Programme /Generalitat de Catalunya. IMB CNM is supported by the María de Maeztu program for Units of Excellence, grant CEX2023 001397 M, funded by MICIU/AEI/10.13039/501100011033. LC-M was partially supported by apre-doctoral fellowship from MICIU (FPU19/01718)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Small dose monitor based on silicon-carbide diodes for FLASH radiotherapy

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Henao, Ángela
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
The FLASH biological effect in radiotherapy has been observed to appear at ultra-high dose rates UHDR ( >$>$ 40 Gy/s), where the accurate dosimetry at such high rates is still a challenge., This study was funded by the LaCaixa Health foundation DosiFLASH Project (HR23-00718), the UHDPulse project, EMPIR programme cofinanced by the European Union's Horizon 2020 research and innovation program (18HLT04), the TWAC: EIC Pathfinder Open 2021 (101046504 project), the CSIC PIE Incorporación CT (2024ICT157), and the NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE. The project also received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M / AEI/10.13039/501100011033). The authors would like to thank Nabil Karkour, Vincent Alaphilippe and Guillaume Martinet from the IJCLab (CNRS) for their technical assistance during the data taking period. The authors would also like to thank Faustino Gómez for his assistance with a part of the readout electronics., Peer reviewed