DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Characterisation of SiC radiation technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
Raw data obtained at the ALBA synchrotron with SiC diode devices for the paper: "Characterisation of SiC radiation detector technologies with synchrotron X-rays", This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., List of files: . Fig3-linescan-SiC-Graphene_50x50_2.dat . Fig3-linescan-SiC-Metal3um_50x50_2.dat . Fig3-LineScan_SiC-NoMetal3um_50x50_2.dat . Fig3-LineScan_SiC_metal50um_50x50.dat . Fig4-currenscan_SiC_metal50um_50x50.dat . Fig4-currentscan-SiC-Graphene_50x50_3.dat . Fig4-currentscan-SiC-Metal3um_50x50_3.dat . Fig5-Energyscan-SiC-Graphene_50x50_2.dat . Fig5-Energyscan-SiC-Metal3um_50x50_1.dat . Fig5-Energyscan-SiC-Metal3um_inRing_50x50_2.dat . Fig5-Energyscan-SiliconReference_Hamamatsu-P1_sample1_50x50_3_sorted.dat . Fig5-EnergyScan_SiC_metal50um_50x50_removed_saturated.dat, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterisation of SiC radiation detector technologies with synchrotron X-rays

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Rafí, Joan Marc
  • Rius, Gemma
  • Godignon, Philippe
  • Pellegrini, Giulio
  • Mena, Silvia
  • Jimenez, Marcio
  • Henao, Angela
  • Bravo, Javier
  • Boer, Roeland
  • Molas, Bernat
  • Guardiola Salmerón, Consuelo
To cope with environments with high levels of radiation, non-silicon semiconductors such as silicon carbide detectors are being proposed for instrumentation. 4H-SiC diodes for radiation detection have been fabricated in the IMB-CNM Clean Room, for which different strategies to define the electrical contact of the implants had been implemented, in an attempt to optimise the technology for, e.g., medical applications or low energy radiation detection, as the material choice can affect the sensitivity of the device. Among these technologies, it is included an epitaxially-grown graphene layer as part of the electrical contact. In this paper, a selection of four configurations of the IMB-CNM SiC diodes are characterised in terms of radiation detector response. Photodiode performance under 20 keV X-rays irradiation in the XALOC beam line at ALBA Synchrotron is presented. Over-responses in the range of 12-19% linked to the interaction of the radiation with the metallic layers are observed. A good uniformity response as well as a good linearity at 0~V bias is reported, even in the under-depleted devices. This work exemplifies the good performance of SiC detectors fabricated at IMB-CNM specifically for low-energy X ray characterization at high X-ray intensities., This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023- 001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Silicon Carbide Diodes at IMB-CNM: Advancing High-Precision Dosimetry for FLASH Radiotherapy

  • Celeste Fleta
  • Iván López-Paz
  • Giulio Pellegrini
  • Marcio Jiménez
  • Angela Henao
  • Consuelo Guardiola
  • María del Carmen Jiménez-Ramos
  • Carmen Torres-Muñoz
  • Javier García López
  • Faustino Gómez
  • José Paz-Martín
The main challenge in radiotherapy (RT) is to deliver a sufficiently high curative dose to the tumour while maintaining tolerable doses to nearby organs at risk, and new treatment modalities are rapidly emerging. FLASH radiotherapy delivers a therapeutic dose several orders of magnitude faster (≥ 40 Gy/s) than conventional RT (0.05 Gy/s) and has been shown to reduce the likelihood of complications in normal tissues while providing a similar or better tumour control rate than conventional dose rates, reducing treatment time and organ motion-related issues. However, there are significant challenges to the clinical implementation of FLASH RT, as its requirements make most existing dosimetry equipment obsolete. The physical properties of silicon carbide (SiC) make it an interesting material for radiation dosimetry. The wide bandgap of SiC reduces the rate of thermally generated charge carriers, thereby reducing leakage current and noise compared to silicon. Of particular interest is the signal yield per deposited mGy in SiC (425 pC/(mGy·mm3) for 4H-SiC) which is lower than for silicon. This makes SiC a good option for dosimetry in ultra-high dose pulsed radiation fields or direct beam monitoring, where the instantaneous dose deposition in the semiconductor is large and could saturate conventional silicon diodes. In addition, SiC has a higher displacement energy threshold and therefore higher radiation hardness than silicon. Today, SiC technology is mature and high quality substrates are available up to 200mm, allowing widespread use. In this talk we will present the novel silicon carbide PiN diodes that have been designed and fabricated at IMB-CNM with the aim to respond to the technological challenges of FLASH RT. In a first characterization with 20 MeV FLASH electron beams at PTB (Germany), these diodes showed their suitability for relative dosimetry up to a dose of 11 Gy per pulse (4 MGy/s) and a dosimetric performance comparable to commercial diamond dosimeters [doi:10.1088/1361-6560/ad37eb]. The performance of the SiC diodes with FLASH proton beams was tested with 7 MeV protons at CMAM (Spain) where they showed good signal linearity with dose rate and reproducible response up to a dose per pulse of at least 20 Gy. Finally, the radiation resistance of the diodes was studied at CNA (Spain) using high LET, intense pulsed proton beams. The sensitivity of the diodes showed a progressive decrease at an initial rate of -1.34%/kGy of 1 MeV protons, and stabilised only for doses close to 750 kGy. However, the linear response with dose per pulse was maintained over a wide range of dose rates even for cumulative doses of several MGy. All of these measurements were made without the need for an external applied voltage. In conclusion, silicon carbide diodes fabricated at IMB-CNM are a real alternative to silicon and diamond dosimeters in a wide range of applications where accurate real-time relative dosimetry, fast response and long-term stability are required., UHDPulse: the EMPIR programme cofinanced by the Participating States and from the European Union's Horizon 2020 research and innovation program (18HLT04). NEWDOSI: Desarrollos tecnológicos para nuevos detectores de estado solido para dosimetría avanzada (PID2021-123484OB-I00). CARACTERIZACION: Caracterización de dosímetros avanzados fabricados en el IMB-CNM para aplicaciones médicas (202250I185). Microdetectors for medical applications. Proyectos Intramurales Especiales CSIC (20225AT008). Dosimetry monitor for FLASH therapy. LaCaixa foundation (HR23-00718), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Dosímetros de Carburo de Silicio resistentes a la radiación para radioterapia de protones y FLASH

  • Ivan Lopez Paz
  • Fleta, Celeste
  • Ángela Henao
  • Marcio Jimenez
  • Mª Carmen Jimenez-Ramos
  • Carmen Torres-Muñoz
  • Javier García-López
  • Paula Ibañez
  • Daniel Sanchez-Parcerisa
  • Adrián Zazpe
  • Inés del Monte-Garcia
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Caracterización de nuevos dosímetros resistentes a la radiación en condiciones FLASH con electrones

  • Angela Henao
  • Iván López Paz
  • Fleta, Celeste
  • Sophie Heinrich
  • Faustino Gómez
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Innovative SiC detectors for FLASH radiotherapy

  • Angela Henao Isaza
  • Ivan Lopez Paz
  • Guardiola Salmerón, Consuelo
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

SiC dosimetry monitor for FLASH Radiotherapy treatments

  • Angela María Henao Isaza
  • Guardiola Salmerón, Consuelo
  • Iván López Paz
This work has been funded by the IMB-CNM (CSIC) internal TRIGGER project PlACeD and the laCaixa Health foundation DosiFLASH project HR23-00718. These experiments were performed at BL13-XALOC beamline at ALBA Synchrotron with the collaboration of ALBA staff. The beam time was funded by ALBA with proposal ID 2024028103. This work has also received funding from the EMPIR programme co-financed by the Par-ticipating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse, from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from Grant RTC-2017–6369–3 (GRACE) by MCIN/AEI/ 10.13039/ 501100011033 and ERDF ‘A way of making Europe’. Support through the Maria de Maeztu grant CEX2023-001397-M funded by MICIU/AEI/10.13039/501100011033 is acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Evaluation of the two-voltage method for parallel-plate ionization chambers irradiated with pulsed beams

  • Paz-Martín, José
  • Schüller, Andreas
  • Bourgouin, Alexandra
  • Gago-Arias, Araceli
  • González-Castaño, Diego M,
  • Gómez-Fernández, Nicolás
  • Pardo-Montero, Juan
  • Gómez, Faustino
Air-vented ionization chambers exposed to clinical radiation beams may suffer from recombination during the drift of the charge carriers towards the electrodes. Thus, dosimetry protocols recommend the use of a correction factor, usually denominated saturation factor ( ksat$k_{\rm sat}$ ), to correct the ionization chamber readout for the incomplete collection of charge. The two-voltage method (TVM) is the recommended methodology for the calculation of the saturation factor, however, it is based on the early Boag model, which only takes into account the presence of positive and negative ions in the ionization chamber and does not account for the electric field screening or the free electron contribution to the signal., Jose Paz-Martín has received a predoctoral research contract from the Xunta de Galicia regional govern-ment. Juan Pardo-Montero acknowledges the support of Xunta de Galicia, Axencia Galega de Innovación (grant IN607D2022). This work has been developed under the project 18HLT04 UHDpulse with funding from the EMPIR innovation program. This work has received funding from ‘la Caixa’ Foundation under the grant agreement HR23-00718 (‘Dosimetry monitor for FLASH therapy’ project) and from grant PLEC2022-009476 funded by MCIN/AEI/10.13039/501100011033 and by the ‘European Union NextGenerationEU/PRTR’. The authors thank Christoph Makowski for the electron linear accelerator maintenance during the measurement campaign, Olaf Tappe for the machining work, and Thomas Hackel for the alanine measurements., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Characterization and Monte Carlo Modelling of ElectronFlash LINAC at Institute Curie

  • Angela Henao Isaza
  • Ivan Lopez Paz
  • Celeste Fleta
  • Johan Sebastián Moreno
  • Sophie Heinrich
  • Consuelo Guardiola
The electron LINAC ElectronFlash installed at the Institut Curie (France) is dedicated to the investigation of the FLASH effect on pre-clinical trials and radiobiology studies [1]. The accurate beam characterization is essential for a proper dose calibration. Although a few dosimeters operate under FLASH conditions, e.g., diamond [2], ultra-thin ionization chambers (UTIC) [3], and SiC-based detectors [4], Monte Carlo (MC) simulations are a complementary tool for estimating doses in scenarios where those dosimeters can have a limited use. This study aims to present the experimental and simulated characterization of the ElectronFlash Linac for both FLASH and conventional modalities using a set of dosimeters and MC simulations. Irradiations were performed at 7 MeV, with 0.5 – 5 μs pulse widths, and up to 250 Hz with different poly methyl methacrylate (PMMA) applicators. The experimental setup consisted in a PTW Water Phantom and a PEEK plastic collimator designed for irradiating mouse lungs (Fig. 1, left). The absolute dosimetry was made with Radiochromic EBT3 films, a PTW FlashDiamond, and UTIC to characterize the percentage depth dose (PDD) in that water tank (Fig. 2, left). The scatter factors were evaluated with new SiC detectors designed and fabricated at IMB-CNM. The beam FWHMs were also quantified with the radiochromic films. We used the open-source GATE MC (vs 10.0.2) to model the beamline starting from the experimental data gathered using the dosimeters mentioned above. Simulations were run in the computational cluster TIRANT v4. Considering the experimental work, the PDDs obtained showed loss of electron equilibrium at the beginning of the curve and non-negligible differences between FLASH and conventional modalities (Fig 1, right). Additionally, there was a significant difference (43%) in the FWHMs between these two modalities, which suggests notable differences in the beam configuration for each one. The scatter factors evaluated with SiC diodes were in good agreement with those from flashDiamond. Interestingly, these PDDs yielded an increase of electron energy compared to the previous PDD reported [3], which reinforce the need to model the LINAC. Regarding the MC study, the simulated PDD showed an excellent agreement with the experimental measured (Fig 2, right) validating the accuracy of the MC modelling. This enables calculate the dose distributions in cases where the dosimeters cannot easily be used, e.g., for small field sizes or large dose gradients. This work shows the first comparison of experimental dose distributions with those obtained with accuracy MC model of the electronFLASH LINAC at Inst. Curie., This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Radiation-Hard Silicon Carbide Dosimeters for Electron and Proton FLASH QA

  • Celeste Fleta
  • Iván López Paz
  • Ángela Henao
  • Marcio Jimenez
  • Mª Carmen Jimenez Ramos
  • Carmen Torres Muñoz
  • Javier García López
  • Sophie Heinrich
  • Faustino Gómez
  • Consuelo Guardiola
The central challenge in radiotherapy (RT) is to deliver a sufficiently high dose to achieve tumour control while sparing healthy tissues. FLASH RT, which delivers radiation at ultra-high dose rates (≥40 Gy/s) compared with conventional RT (≈0.05 Gy/s), has emerged as a promising approach. Preclinical studies have shown that FLASH reduces toxicity in normal tissues while preserving or even improving tumour control. It also shortens treatment times, reducing the impact of patient and organ motion. However, the clinical translation of FLASH RT requires new dosimetry solutions, since conventional detectors saturate, lose linearity, or degrade rapidly under ultra-high dose rate conditions. Silicon carbide (SiC) is a promising semiconductor material to address these needs. Compared to silicon, SiC has a wide bandgap that reduces leakage current and noise, a higher displacement energy threshold that increases radiation hardness, and lower signal yield per unit dose, which prevents saturation at very high instantaneous dose rates. Nowadays, SiC technology is mature, with reproducible wafer-scale fabrication. At IMB-CNM (CSIC), 4H-SiC PiN diodes have been designed and fabricated specifically for FLASH RT applications. Their performance has been validated in different facilities and radiation conditions. At PTB (Germany), the devices showed linearity up to 11 Gy per pulse (≈4 MGy/s) with 20 MeV electron beams and a performance comparable to PTW’s flashDiamond. At CMAM (Spain), the diodes showed reproducible, linear response to 7 MeV protons up to 26 Gy per pulse. In addition, radiation hardness experiments at CNA (Spain) demonstrated that, after an initial sensitivity loss of ~1.3%/kGy, stability was reached near 1 MGy of 2 MeV protons, with linear response preserved up to cumulative doses of at least 4 MGy. All measurements were performed without external bias, like conventional silicon diodes are used in clinical settings, meaning no adaptation of existing workflows would be required. In parallel, pixelated SiC arrays have been produced for spatially resolved dosimetry. A 12-pixel array was fabricated and tested with 7 MeV electrons at the Institut Curie (France). The array produced accurate 2D dose maps at 10 Gy per pulse, demonstrating the feasibility of SiC arrays for real-time QA under FLASH conditions. Efforts are currently underway to scale up the pixellated system to a larger array of 400 channels with a custom readout electronics for broader clinical and preclinical applications., This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Innovation in dosimetry for FLASH radiotherapy

  • Faustino Gómez
This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

A 2D SIC-BASED DETECTOR FOR REAL-TIME SPATIAL DOSIMETRY IN ELECTRON FLASH RADIOTHERAPY

  • Fleta, Celeste
  • Lopez Paz, Iván
  • Henao, Angela
  • Pellegrini, Giulio
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

OPENGATE MONTE CARLO SIMULATIONS FOR ELECTRON FLASH DOSIMETRY

  • Henao Isaza, Angela
  • Sebastián Moreno, Johan
  • López Paz, Iván
  • Fleta, Celeste
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
This study presents the experimental and simulated characterization of the ElectronFlash LINAC for FLASH modality, using a set of dosimeters and Monte Carlo (MC) simulations. Future work will focus on studying the dose distribution map of a mouse CT from a representative sample used in pre-clinical studies., This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

SILICON CARBIDE-BASED PROTOTYPES FOR SPATIAL RESOLVED PROTON UHDR DOSE MONITORS

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Henao, Angela
  • Gomez, Faustino
  • Jimenez-Ramos, Mª Carmen
  • Torres-Muñoz, Carmen
  • García-López, Javier
  • Barroso Molina, Diego
  • Ibañez, Paula
  • Sanchez-Parcerisa, Daniel
  • Zazpe, Adrián
  • Monte-Garcia, Ines
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Bending the Limits: Flexible Slim Silicon Carbide detectors for In Vivo FLASH Dosimetry in Small Animal Models

  • Heinrich, Sophie
  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Henao, Angela
  • Giaccaglia, Camilla
  • Pellegrini, Giulio
  • Guardiola Salmerón, Consuelo
This work has been funded by the laCaixa Health foundation DosiFLASH project HR23-00718, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions

  • Jiménez-Ramos, M. Carmen
  • Torres-Múñoz, Carmen
  • García-López, Javier
  • Barroso-Molina, Diego
  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications., This work has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse. It has also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718) M. Carmen Jim´enez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4” with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions, Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions

  • Jiménez-Ramos, M. Carmen
  • Torres-Múñoz, Carmen
  • García-López, Javier
  • Barroso-Molina, Diego
  • Guardiola Salmerón, Consuelo
  • Fleta, Celeste
FLASH therapy has emerged as a promising radiotherapy technique, minimizing damage to healthy tissues while maintaining effective tumor control. Achieving FLASH conditions requires dose rates exceeding 40 Gy/s, but conventional dosimetry systems fail under these conditions. Recently, IMB-CNM (CSIC) developed SiC p-n diodes with 30 μm diameter and 3 μm thickness, specifically designed for FLASH radiotherapy. This study investigates their response to low-energy UHDR proton beams after high and ultra-high accumulated doses for the first time. Experiments were performed in the 3 MV tandem accelerator at CNA using 1 MeV and 2 MeV protons with a pulsed beam system, achieving mean dose rates of 10 kGy/s, dose-per-pulse of 5.6 Gy, and dose rate within the pulse of 4.6 MGy/s. Ion pulses were characterized using a Faraday Cup and Rutherford Backscattering Spectrometry (RBS). Two SiC diodes were studied: one pre-irradiated with 3.6 MGy for extreme applications and another for early irradiation stages. The pre-irradiated diode showed a sensitivity decrease of -1.34 %/kGy up to 750 kGy, stabilizing within 7 % response variation up to 4.5 MGy. The response remained linear within 10 % at mean dose rate up to 5 kGy/s for 2 MeV protons, demonstrating the feasibility of this technology for FLASH applications., This work has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation program under project 18HLT04-UHDpulse. It has also received funding from project NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE and from the project “Dosimetry monitor for FLASH therapy” financed by LaCaixa foundation (HR23-00718) M. Carmen Jim´enez-Ramos acknowledges the support of this work through a VI PPIT-US contract. This investigation has been partially funded by the projects refs. “ASTRO21/1.1/1” and “ASTRO21/1.4/4” with financing from the European Union - NextGenerationEU”, the Ministry of Science, Innovation and Universities, Recovery Plan, Transformation and Resilience, the Department of University, Research and Innovation of the Junta de Andalucía and the University of Sevilla., List of files: . Fig_11_12_Ratio; Fig_11_Ratio; Fig_13_Detector; Fig3_single; Fig7a_RBS; Fig7b_MCS; Fig8_9RBS; Fig10; README.txt, No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Small dose monitor based on silicon-carbide diodes for FLASH radiotherapy

  • Lopez Paz, Ivan
  • Fleta, Celeste
  • Henao, Ángela
  • Heinrich, Sophie
  • Guardiola Salmerón, Consuelo
The FLASH biological effect in radiotherapy has been observed to appear at ultra-high dose rates UHDR ( >$>$ 40 Gy/s), where the accurate dosimetry at such high rates is still a challenge., This study was funded by the LaCaixa Health foundation DosiFLASH Project (HR23-00718), the UHDPulse project, EMPIR programme cofinanced by the European Union's Horizon 2020 research and innovation program (18HLT04), the TWAC: EIC Pathfinder Open 2021 (101046504 project), the CSIC PIE Incorporación CT (2024ICT157), and the NEWDOSI (PID2021-123484OB-I00), financed by MCIN / AEI / 10.13039/501100011033 / FEDER, UE. The project also received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M / AEI/10.13039/501100011033). The authors would like to thank Nabil Karkour, Vincent Alaphilippe and Guillaume Martinet from the IJCLab (CNRS) for their technical assistance during the data taking period. The authors would also like to thank Faustino Gómez for his assistance with a part of the readout electronics., Peer reviewed