Skip to main content

LOCALIZACION Y DETECCION PARA SEGUIMIENTO DE MOVIMIENTO Y ACTIVIDAD DE PERSONAS

PID2021-122642OB-C41

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Combined infrared-ultrasonic positioning system to improve the data availability

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
This work was supported in part by MCIN/AEI/10.13039/501100011033 and EU “NextGenerationEU”/PRTR (ref. TED2021-131773B-I00) Proyectos, Many indoor positioning applications related to accurate monitoring and tracking targets require centimeter precision. Infrared (IR)- and ultrasound (US)-based systems represent a feasible approach providing high robustness against interference. Furthermore, their combination may achieve better performance by mitigating their complementary drawbacks, covering larger areas, and improving the availability of positioning measurements. In this context, this work presents the proposal and experimental evaluation of a tightly coupled fusion method that uses an extended Kalman filter (EKF) to merge an IR- and a US-based positioning system. An outlier detection method is considered to select measurements with an adequate performance. Experimental results reveal that the IR and US systems are unable to position in 4.08% and 26.06% of locations, whereas the combined IR -US system has 100% of availability. In addition, the merged solution achieves less than 4 cm of positioning error in 90% of cases, outperforming the IR and US systems when they work independently., Agencia Estatal de Investigación, Universidad de Alcalá, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Extracting daily routines from raw RSSI data

  • Montoliu, Raúl
  • Sansano Sansano, Emilio
  • Martínez García, Marina
  • Lluva Plaza, Sergio|||0000-0002-0050-2807
  • Jiménez Martín, Ana|||0000-0003-0713-0054
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • García Domínguez, Juan Jesús|||0000-0002-7121-8651
Detecting behavioral routines is an important research area with many implications in various practical applications. One such application involves studying the behavior of older adults residing in care homes. This paper proposes a comprehensive methodology for extracting and analyzing the daily routines of older adults in care homes. The methodology utilizes raw data comprising signal strength measurements obtained from smartwatches worn by six volunteers over five months. To establish the basis for estimating daily activities, fingerprint-based localization techniques are employed to track the minute-by-minute location of each volunteer. Subsequently, the activity performed by each volunteer is estimated for each day. Finally, the study estimates the probability of a user undertaking each one of the studied activities on a given weekday., Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Multisensory system for long-term activity monitoring to facilitate aging-in-place

  • Lluva Plaza, Sergio|||0000-0002-0050-2807
  • Jiménez Martín, Ana|||0000-0003-0713-0054
  • Gualda Gómez, David|||0000-0003-2071-6260
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • García Domínguez, Juan Jesús|||0000-0002-7121-8651
Demographic changes and an ageing population require more effective methods to confront the increased prevalence of chronic diseases which generate dependence in older adults as well as an important rise in social expenditure. The challenge is not only to increase life expectancy, but also to ensure that the older adults can fully enjoy that moment in their lives, living where they wish to (private home, nursing home, …). Physical activity (PA) is a representative parameter of a person’s state of health, especially when we are getting older, because it plays an important role in the prevention of diseases, and that is the reason why it is promoted in older adults. One of the goals of this work is to assess the feasibility of objectively measuring the PA levels of older adults wherever they live. In addition, this work proposes long-term monitoring that helps to gather daily activity patterns. We fuse inertial measurements with other technologies (WiFi- and ultrasonic-based location) in order to provide not only PA, but also information about the place where the activities are carried out, including both room-level location and precise positioning (depending on the technology used). With this information, we would be able to generate information about the person’s daily routines which can be very useful for the early detection of physical or cognitive impairment., Junta de Comunidades de Castilla-La Mancha, Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Ultrasonic Device-Free Localization System Using Orthogonal Chirp-Based Multistatic Sonar

  • García Requejo, Alejandro|||0000-0002-4955-8852
  • Pérez Rubio, María del Carmen|||0000-0001-8271-6843
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Wright, William M. D.
This work was supported in part by MCIN/AEI/10.13039/501100011033 and EU “NextGenerationEU”/PRTR (ref. TED2021-131773B-I00), Indoor device-free localization (DFL) systems offer an alternative paradigm to traditional location, in which the target to be located does not need to carry any sensor, tag, or electronic device. In contrast to most popular DFL systems, which are based on radio frequency technologies, ultrasonic signals have been used in this work, due to their good accuracy results, to estimate the 3-D position of a person's head. For this purpose, a four-emitter and a single-receiver multistatic sonar installed overhead has been employed. The emission signals follow a time division orthogonal chirp division multiplexing (TD-OCDM) access technique to obtain a 300 ms update time and asynchronous operation. The signals propagated in the indoor space are acquired by the receiver and processed. A sign-data least mean square (SD-LMS) adaptive filter algorithm has been applied in order to remove the background components on the received signal. Then, a specific window from the resulting clean signal is employed to determine the reflected signal at the target time-of-arrival (ToA) by using an adaptive threshold. The ToA obtained, together with the direct path ToA between emitters and the receiver, provide ranges to compute the target location using a localization algorithm. A simulator was used to analyze the proposal, estimating the coverage area of the system at 3.14 m(2). Several experiments have been performed with a single user placing the multistatic sonar at heights of 2.60 and 2.80 m above the floor within the coverage area. The results achieved positioning errors lower than 9 cm for the 2.60-m height and 11.6 cm at 2.80 m in 90% of the cases., Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

HIFDA - High-Frequency Electrical Voltage and Current Signals from Household Appliances

  • Navarro Pérez, Víctor Manuel
  • Barragán Frías, Marta
  • Nieto Capuchino, Rubén|||0000-0002-8293-9665
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
This work was supported in part by MCIN/AEI/10.13039/501100011033 and EU “NextGenerationEU”/PRTR (ref. TED2021-131773B-I00), The increasing demand for efficient energy management in smart grids has led to the development of various Non-Intrusive Load Monitoring (NILM) techniques. These aim to disaggregate energy consumption and classify appliances using data from a single-point smart meter at a household's grid mains. With the use of machine learning methods, NILM solutions increasingly rely on datasets for training and validation. While datasets like WHITED, BLOND, and UK-DALE provide insights into consumption patterns, they face limitations such as lack of steady-state data, complicated ground-truth or low sampling rates, which hinder detecting low-power appliances. High sampling rates, however, improve classification accuracy and enable identifying these devices. This study introduces the HIgh Frequency household electrical signals DAtaset (HIFDA), a high-frequency dataset capturing steady-state signals from 14 household appliances at 100 kSPS, including the empty grid. Data, collected via a custom System-on-Chip (SoC) device, focuses on active consumption and includes multiple time windows. HIFDA, hosted on Zenodo, ensures its suitability for modern NILM research and other applications., Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

A comparison between autocorrelation- and crosscorrelation-based coarse frame synchronization schemes for OFDM-PLC systems

  • Colombo, Martín Alejandro
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Marziani, Carlos Manuel de
  • Mayosky, Miguel Ángel
Orthogonal frequency division multiplexing (OFDM)-based Power-Line Communications (PLC) systems are vulnerable to synchronization errors, and the particularities of the PLC channel affect the performance of the synchronization process. In this context, this work is focused on the initial pilot symbol detection, presenting a comparison between autocorrelation- (AC) and crosscorrelation (CC)-based timing metrics, which include the most common preamble-based synchronization strategies. Two robust timing metrics are defined and the effect of multipath, Colored Background Noise (CBN) and Impulsive Noise (IN) is theoretically evaluated on each. A detailed analysis of the probability distributions of the timing metrics is performed and primary detection thresholds and lower bounds for the symbol detection probability are derived. Simulations of the OFDM-PLC system are performed in order to validate the analysis, considering a statistic PLC channel model and different noise sources. Results show that the CBN and IN significantly degrade the timing metrics behavior, and that the CC-based timing metric is more robust to this worsening, thus achieving a better synchronization performance than the AC-based timing metric., Agencia Estatal de Investigación