Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monte Carlo model of a BEGe detector to support gamma-spectrometry in an emergency response

  • Ordóñez-Ródenas, José|||0000-0001-8150-4873
  • Martorell Alsina, Sebastián Salvador|||0000-0003-1706-4740
  • Gallardo Bermell, Sergio|||0000-0002-3703-9983
  • Ortiz Moragón, Josefina
[EN] One of the problems of measuring high radioactivity in an emergency scenario is the fact that the detector can become saturated or reach a measuring dead time too high to give reliable results, which means repeating the measurement in different conditions with the associated delay in obtaining the results and the laboratory workers' risk of exposure. The counting rate can be controlled by varying the sample-to-detector distance as well as by using different source volumes. A Monte Carlo model of a BEGe detector was developed to analyse the system efficiency response for several measuring configurations (distances and volumes) using the MCNP6 code. The total efficiency curves were obtained for an energy range between 59.5 keV and 1836 keV. The simulations provided an estimation of the admissible gamma-rate for different source volumes (in water matrix) and sample-to-detector distances to avoid detector saturation in given measurement conditions. The results were a compromise between geometry, distance and measuring time for certain emergency situations. Three case studies are provided to show the approach's effectiveness., The authors gratefully acknowledge the Catedra CSN-UPV Vicente Serradell, Spain as well as the Laboratorio de Radiactividad Ambiental (Universitat Politecnica de Valencia), Spain, for the dedicated funding and resources for this research work under Grant No. FPI-2015-S2-1576. The authors are also grateful to the Valencian Agency for Security and Emergency and the Generalitat Valenciana for their support in the "Convenio de colaboracion entre la Agencia Valenciana de Seguridad y Respuesta a las Emergencias y la Universitat Politecnica de Valencia para el Desarrollo del Plan de Vigilancia Radiologica en Emergencias" under Grant No. S7042000, 2018.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Rapid methods for radiostrontium determination in aerosol filters and vegetation in emergency situations using PS resin

  • Sáez-Muñoz, Marina|||0000-0003-0180-7167
  • Carlos Alberola, Sofía|||0000-0002-0637-325X
  • Martorell Alsina, Sebastián Salvador|||0000-0003-1706-4740
  • Bagán, Héctor
  • Tarancón, Alex
  • García, José F.
  • Ortiz Moragón, Josefina
[EN] This study describes a rapid and novelty method for radiostrontium determination in aerosol filters and vegetation based on the use of plastic scintillation resins (PS resin), which combines the separation and measurement preparation into a single step. The optimization of the pre-treatment steps and the use of PS resin allows a simplification of the radiochemistry and a reduction in the time of analysis to 8 h and 12 h for aerosol filters and vegetation, respectively. The limits of detection were on average 0.04 Bq (filter)(-1) and 3 Bq (kg-fresh)(-1). The method obtained high recoveries (82% on average) and relative bias for total radiostrontium were below 30%. Individual activities of Sr-89 and Sr-90 were obtained by deconvolution methods., The authors are grateful to the Spanish Ministerio de Economia y Competitividad (MINECO) for financial support, under CTM2017-87107-R and the Catalan Agencia de Gestio d'Ajuts Universitaris i de Recerca (AGAUR) for financial support, under 2017-SGR-907. We should also like to thank the Universitat Politecnica de Valencia for finantial support under the "Programa propio para la Formacion de Personal Investigador (FPI) de la Universitat Politecnica de Valencia-Subprograma 1", and the Valencian Agency for Security and Emergency for their support (S7042000 (2018)) in the "Development of the Emergency Radiological Surveillance Plan" in the Valencian Community (Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Rapid evaluation of gross alpha and gross beta in water samples for emergency response

  • Sáez-Muñoz, Marina|||0000-0003-0180-7167
  • Martorell Alsina, Sebastián Salvador|||0000-0003-1706-4740
  • Ortiz Moragón, Josefina
[EN] This paper presents a three-stage protocol for gross alpha and gross beta evaluation in water samples in emergencies. The novelty of this approach is the great level of detail for its application in this type of sample, following the criteria proposed in well-established safety guidelines. This protocol makes use of a rapid method adapted from different proposals found in the scientific literature. The method is based on a simple preparation of the sample and a rapid measurement by liquid scintillation counting on Quantulus 1220, which permits the evaluation of waters with different salt content (from 5 g l(-1) of continental and drinking water, to 35 g l(-1) of seawater) and pH (from 1 to 8) in emergency situations. The protocol and the method allow to prioritize the most active samples and to assess contamination in less than 2 h. Both were tested and validated with spiked water samples with different ratios of alpha and beta emitters (1:1, 1:10 and 10:1) and with intercomparison water samples. Relative bias are below 10%, except in the samples with activities close to the limits of detection and relative standard deviation are below 10% in most of the samples, which give a clear idea of the robustness of the method., The authors are grateful to the Universitat Politecnica de Valencia for finantial support under the "Programa propio para la Formacion de Personal Investigador (FPI) de la Universitat Politecnica de Valencia Subprograma 1". Also thank to the Valencian Agency for Security and Emergency and the Generalitat Valenciana for their support in the "Convenio de colaboracion entre la Agencia Valenciana de Seguridad y Respuesta a las Emergencias y la Universitat Politecnica de Valencia para el Desarrollo del Plan de Vigilancia Radiologica en Emergencias" (grant S7042000, 2018).