Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Modelling and Experimental Validation of a Novel Co-Axial Spiral Borehole Heat Exchanger

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Witte, Henk
  • Hylkema, Roon
  • Corberán, José M.
In order to optimize the operation of a ground source heat pump (GSHP) system, the development of dynamic models that integrate all the system components is a key factor. Particularly, the modelling of the ground source heat exchanger and its coupling to the heat pump operation becomes important. Usually, this kind of systems present an on/off operation, which makes it necessary to have an accurate prediction of both the short and long thermal response of the borehole heat exchanger (BHE). In this context, the novel B2G dynamic model was developed and experimentally validated in previous works for a single U-loop BHE. This work presents the adaptation and experimental validation of the B2G dynamic model to a novel co-axial spiral BHE configuration designed in the framework of a HORIZON 2020 European Project, GEOT CH (Geothermal Technology for conomic Cooling and Heating). The results show that the B2G approach applied to this specific configuration produces a model that can accurately predict the behavior of the BHE., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Seasonal performance assessment of a Dual Source Heat Pump system for heating, cooling and domestic hot water production

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Corberán, José M.
In order to contribute to a global CO2 emissions reduction in 2020, the increase in the use of highly efficient heat pumps for heating, cooling and domestic hot water production in buildings is very recommendable. In this direction, Ground Source Heat Pump (GSHP) systems are generally recognized as one of the most energy-efficient compared to air source heat pump systems. However, this strongly depends on the temperature evolution of the air and the ground during the year, which also depends on the geographical location of the system. Therefore, an optimal system from the energy point of view apparently would be the one that is able to switch from one source to the other in order to operate the heat pump with the highest efficiency. In this context, a new Dual Source Heat Pump (DSHP) unit for heating, cooling and production of domestic hot water, was developed and manufactured in the framework of a H2020 European project called GEOT CH (Geothermal Technology for conomic Cooling and Heating). This paper presents the assessment of such a DSHP in different representative locations around Europe. For this purpose, an integrated system model in TRNSYS was developed to assess its performance for different thermal demand profiles obtained for the same building under different conditions., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating), by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)” and by the Ministerio de Educación, Cultura y Derporte inside the program “Formación de Profesorado Universitario (FPU15/03476)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Influence of Different Ground Thermal Properties in a Borehole Heat Exchanger s Performance Using the B2G Dynamic Model

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Montero Reguera, Álvaro Enrique|||0000-0002-4165-4743
  • Martos Torres, Julio
  • Corberán, José M.
Ground source heat pump (GSHP) systems for heating and cooling represent an efficient alternative to conventional air source heat pump systems, always provided that they present an efficient design and operation. In this context, the development of energy optimization strategies becomes essential, with the aid of integrated dynamic models of the system, specially the ground source heat exchanger. In previous works, a single U borehole heat exchanger (BHE) dynamic model, called Borehole-to-Ground (B2G), was developed and experimentally validated. The B2G model is based on the thermal network approach, combined with a vertical discretization of the borehole. However, the thermal properties of the surrounding ground were modelled as an average, constant with depth. For homogeneous type of soils, this assumption might be acceptable but, when considering heterogeneous type of soils, modelling the presence of different layers with different materials could provide more accurate results. In this work, the B2G model has been adapted in order to account for the effect of a heterogeneous ground profile on the fluid temperature evolution along the borehole depth. Experimental data corresponding to a Thermal Response Test (TRT) performed in a real BHE existing at the Universitat Politècnica de València, were used to validate this new feature of the B2G model. Finally, it is concluded that the model can serve as a ground thermal properties estimation tool., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Upgrade of the B2G dynamic geothermal heat exchanger model: optimal location of the ground nodes

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla
  • Corberán, José M.
  • Tinti, Francesco
  • Focaccia, Sara
In order to optimize the design and operation of a ground source heat pump system, the modeling of the Borehole Heat Exchanger (BHE) and its coupling to the heat pump operation becomes crucial. This becomes key for those systems with on/off operation, where it is important to model the short-term response of the BHE accurately. Furthermore, the modeling of the local variation of the ground temperature near the BHE will be highly influenced by ground thermal properties and the operation of the system. In this context, the novel B2G dynamic model was developed and experimentally validated in previous works for a single U BHE and adapted to a novel coaxial spiral configuration. In order to consider the influence of the soil surrounding the BHE, two ground nodes were initially defined and their position (penetration radii) was calculated for a specific type of soil and operating conditions. This paper presents an upgrade of the B2G model, with a descripton of penetration radii calculation. For this purpose, a comparison between the B2G model and the Infinite Cylindrical Source model was carried out to find the penetration radii that reproduce the ground thermal response with a higher accuracy under the corresponding soil thermal properties and operating conditions., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”