Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 23
Encontrada(s) 1 página(s)

TECNALIA Publications
Publication Artículo científico (JournalArticle)

A Model of a Diaphragm Wall Ground Heat Exchanger

  • Shafagh, Ida
  • Rees, Simon
  • Urra Mardaras, Iñigo
  • Curto Janó, Marina
  • Polo Carbayo, Merche
Ground thermal energy is a sustainable source that can substantially reduce our dependency on conventional fuels for heating and cooling of buildings. To exploit this source, foundation sub-structures with embedded heat exchanger pipes are employed. Diaphragm wall heat exchangers are one such form of ground heat exchangers, where part of the wall is exposed to the basement area of the building on one side, while the other side and the further depth of the wall face the surrounding ground. To assess the thermal performance of diaphragm wall heat exchangers, a model that takes the wall geometry and boundary conditions at the pipe, basement, and ground surfaces into account is required. This paper describes the development of such a model using a weighting factor approach, known as Dynamic Thermal Networks (DTN), that allows representation of the three-dimensional geometry, required boundary conditions, and heterogeneous material properties. The model is validated using data from an extended series of thermal response test measurements at two full-scale diaphragm wall heat exchanger installations in Barcelona, Spain. Validation studies are presented in terms of comparisons between the predicted and measured fluid temperatures and heat transfer rates. The model was found to predict the dynamics of thermal response over a range of operating conditions with good accuracy and using very modest computational resources.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development of map-based models for the performance characterization in a new prototype of Dual Source Heat Pump

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Song, Yang
[EN] This paper presents the development of accurate map-based models for characterizing a new Dual Source Heat Pump prototype. This unit includes three braze plate heat exchangers and a round tube fin heat exchanger, allowing the unit to select different operating modes such as heat pump, chiller, and domestic hot water production using as source the ground or air. Therefore, due to the hybrid typology of this unit and the possibility of reversing the cycle, this work covers the main heat pump and refrigeration equipment technologies currently available on the market (air source and ground source units). The modeling strategy selected has been to provide several polynomial expressions to predict the performance of these units, i.e., compressor energy consumption and condenser and evaporator capacities. This approach allows obtaining accurate, compact, and easy-to-implement models for developing dynamic models of more complex systems where this type of unit ¿ the heat pump ¿ is an integrated part of the system. Currently, a clear example of this modeling strategy can be found in characterizing one of the main components installed in these machines, the compressor. The AHRI-540 standard specifies a polynomial model as a function of evaporating and condensing temperatures. In this sense, for the characterization of heat pumps, the polynomials developed depend only on the unit¿s external variables, so they can be useful in many scenarios, obtaining direct feedback on the heat pump performance when developing a dynamic model to optimize system control strategies or to develop techno-economic studies. In this case, the hybrid typology of this unit makes it particularly relevant to optimize the control to manage the type of source to be used (air or ground), allowing the development of a more efficient and sustainable technology by selecting the most adequate source in terms of performance. This study focuses on obtaining the polynomial expressions that minimize the number of terms while simultaneously minimizing prediction error. By carefully selecting the most significant terms and suitable transformations in the characterized variables, the goal is to prevent overfitting, minimize potential extrapolation or interpolation errors and obtain polynomial expressions that can be fitted with small experimental samples. For this purpose, a detailed model implemented in a commercial software for heat pump characterization has been used, with which a large number of simulation results were generated. These simulation results include a fine meshing working map of the unit that allowed us to analyze the relationships between the characterized and external variables., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 - GEOTeCH (Geothermal Technology for Economic Cooling and Heating) , by the project "DESCARBONIZACI & Oacute;N DE EDIFICIOS E INDUSTRIAS CONSISTEMAS H & Iacute;BRIDOS DE BOMBA DE CALOR", funded by the "Ministerio de Ciencia e Innovacion", MCIN, Spain, with code number: PID2020-115665RB-I00 and by the "Ministerio de Educacion, Cultura y Derporte", MECD, Spain, inside the program "Formacion de Profesorado Universitario (FPU15/03476) ". Many thanks as well to the late Dr. Jose Miguel Corberan, without whom this work would never have been possible. Sadly, Dr. Jose Miguel Corberan passed away in July of 2022. I wish to give my wholehearted support to Jose Miguel's family. I hope we did you proud.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

MODELLING AND EXPERIMENTAL VALIDATION OF AN INNOVATIVE COAXIAL HELICAL BOREHOLE HEAT EXCHANGER FOR A DUAL SOURCE HEAT PUMP SYSTEM

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
[ES] La energía geotérmica de baja entalpía es una alternativa eficiente y renovable a los sistemas convencionales para proporcionar calefacción, refrigeración y producir agua caliente sanitaria (ACS) de forma sostenible. El proyecto GEOTeCH plantea el desarrollo de sistemas con bomba de calor geotérmica más eficientes y con un coste menor en comparación con el mercado. Para ello, se ha desarrollado un nuevo tipo de intercambiador enterrado coaxial con flujo helicoidal en el tubo externo que presenta una mayor eficiencia y permite reducir la longitud de intercambiador a instalar, así como una bomba de calor dual con compresor de velocidad variable, capaz de trabajar con el terreno o el aire como fuente/sumidero, seleccionando la que proporcione un mejor rendimiento del sistema. El principal objetivo es desarrollar un sistema eficiente y replicable para proporcionar calefacción, refrigeración y producir ACS en el sector de mercado de pequeños edificios con un tamaño menor en el campo de intercambiadores enterrados y un aumento de la eficiencia. Para demostrar la aplicabilidad de estos sistemas, se han construido tres instalaciones demostración en tres países europeos. En esta tesis doctoral se ha desarrollado un modelo dinámico completo del sistema en el software TRNSYS, capaz de reproducir el comportamiento de los diferentes componentes y del sistema en general. Este modelo constituye una herramienta útil para el desarrollo y análisis de diferentes estrategias de control sin la necesidad de implementarlas en instalaciones reales, así como analizar el comportamiento del sistema funcionando bajo condiciones diferentes. Para este propósito, es necesario desarrollar modelos detallados de los nuevos componentes desarrollados en el proyecto: el intercambiador enterrado coaxial helicoidal y la bomba de calor dual; para poder acoplarlos al resto de componentes en el modelo completo del sistema. Por ello, se ha desarrollado un modelo dinámico del nuevo intercambiador, capaz de reproducir con precisión el comportamiento a corto plazo del intercambiador, enfocado a la evolución de la temperatura del fluido, y se ha validado con datos experimentales en diferentes condiciones de operación. Para poder reproducir no solo el comportamiento dinámico del intercambiador enterrado, sino también la respuesta a largo plazo del terreno y la interacción entre intercambiadores en un campo, se ha desarrollado otro modelo en TRNSYS que realiza esta función. De esta manera, al acoplar ambos modelos es posible reproducir el comportamiento a corto plazo del intercambiador enterrado a la vez que la respuesta a largo plazo del terreno. Por otro lado, se ha implementado en TRNSYS un modelo de la bomba de calor dual desarrollado. Con este modelo es posible calcular la capacidad de la bomba de calor dependiendo del modo de operación en que esté funcionando, de la frecuencia del compresor y otras variables y condiciones de operación. El modelo del sistema dual en TRNSYS se ha utilizado para hacer un análisis de su comportamiento funcionando en diferentes climas, para ello se han seleccionado tres ciudades en España y en Europa con diferentes climas y se han realizado simulaciones del sistema funcionando en cada ciudad. Por otro lado, también se ha modelado en TRNSYS una de las instalaciones demostración del proyecto GEOTeCH, incluyendo el edificio climatizado y el acoplamiento con los fan coils. Con este modelo se estudia una nueva estrategia para controlar la frecuencia del compresor en base a la temperatura de las habitaciones, en lugar de controlarla en base a la temperatura de suministro, con el objetivo de reducir el consumo del compresor cuando ya se haya conseguido el confort. Además, otras estrategias de optimización se han analizado con el modelo.Por tanto, los modelos desarrollados constituyen herramientas útiles para ayudar en el diseño del sistema y los diferentes componentes, el análisis de su comportamiento y el d, [CA] L'energia geotèrmica de baixa entalpia es planteja com una alternativa eficient i renovable als sistemes convencionals per proporcionar calefacció, refrigeració i produir aigua calenta sanitària (ACS) de forma sostenible. El projecte GEOTeCH planteja el desenvolupament de sistemes amb bomba de calor geotèrmica més eficients i amb un cost menor en comparació amb el mercat. Per a això, s'ha desenvolupat un nou tipus d'intercanviador enterrat coaxial amb flux helicoïdal en el tub extern que presenta una major eficiència i permet reduir la longitud a instal·lar, així com una bomba de calor dual amb compressor de velocitat variable, capaç de treballar amb el terreny o l'aire com a font, seleccionant la que proporcione un millor rendiment. Aquests components s'utilitzen en el nou sistema amb bomba de calor dual. El principal objectiu és desenvolupar un sistema eficient i replicable per proporcionar calefacció, refrigeració i produir ACS en edificis xicotets amb una grandària menor d'intercanviadors soterrats i un augment de l'eficiència. Per demostrar l'aplicabilitat d'aquests sistemes, s'han construït tres instal·lacions demostració en Itàlia, Països Baixos i Regne Unit. En aquesta tesi s'ha desenvolupat un model dinàmic complet del sistema en TRNSYS, capaç de reproduir el comportament dels components i del sistema en general. Aquest model constitueix una eina útil per al desenvolupament i anàlisi de diferents estratègies de control sense la necessitat d'implementar-les en instal·lacions reals, així com analitzar el comportament del sistema funcionant en condicions diferents. Per a això, cal desenvolupar models detallats dels nous components desenvolupats en el projecte: l'intercanviador enterrat i la bomba de calor dual; per poder acoblar-los a la resta de components. Per això, s'ha desenvolupat un model dinàmic del nou intercanviador enterrat, capaç de reproduir amb precisió el comportament a curt termini de l'intercanviador, enfocat a l'evolució de la temperatura del fluid, i s'ha validat amb dades experimentals en diferents condicions d'operació. Per a poder reproduir no només el comportament dinàmic de l'intercanviador soterrat, sinó també la resposta a llarg termini del terreny i la interacció entre intercanviadors en un camp, s'ha desenvolupat un altre model en TRNSYS que realitza aquesta funció. D'aquesta manera, en acoblar els dos models és possible reproduir el comportament a curt termini de l'intercanviador enterrat, al mateix temps que la resposta a llarg termini del terreny. D'altra banda, s'ha implementat en TRNSYS un model de la bomba de calor. Amb aquest model és possible calcular la capacitat de la bomba de calor depenent del mode d'operació en què estiga funcionant, de la freqüència del compressor i altres variables i condicions d'operació. El model del sistema dual en TRNSYS s'ha utilitzat per a fer una anàlisi del seu comportament funcionant en diferents climes, per a això s'han seleccionat tres ciutats a Espanya i tres a Europa amb diferents climes i s'han realitzat simulacions del sistema funcionant en cada ciutat durant un any. S'ha analitzat l'eficiència del sistema en cada ciutat, així com l'ús de cadascuna de les fonts (aire / terreny). D'altra banda, també s'ha modelat en TRNSYS una de les instal·lacions demostració del projecte GEOTeCH, incloent l'edifici d'oficines climatitzat i l'acoblament amb els fan coils. Amb aquest model es pretén estudiar una nova estratègia per a controlar la freqüència del compressor d'acord amb la temperatura de les habitacions, en lloc de controlar-la en base a la temperatura de subministrament, amb l'objectiu de reduir el consum del compressor quan les habitacions ja es troben en condicions de confort. A més, altres estratègies d'optimització s'han analitzat amb el model. Per tant, els models desenvolupats constitueixen eines útils per ajudar en el disseny del sistema i els diferents components, l'anàlisi del, [EN] Low enthalpy geothermal energy is considered as an efficient and renewable alternative to conventional systems to provide heating, cooling and Domestic Hot Water (DHW) production in a sustainable way. In this context, the GEOTeCH project proposes the development of more efficient geothermal heat pump systems with a lower cost compared to the market. To this end, a new type of coaxial Borehole Heat Exchanger (BHE) with helical flow through the outer tube has been developed, which presents a higher efficiency and allows to reduce the length of the heat exchanger to be installed, as well as a Dual Source Heat Pump (DSHP) with variable speed compressor, capable of working with the ground or air as a source / sink, selecting the one that provides the best performance of the system. These components are used in the new DSHP system developed. The main objective is to develop efficient and replicable systems to provide heating, cooling and DHW in the market sector of small buildings with a smaller size of the BHE field and an increase in the efficiency. To demonstrate the applicability of these systems, three demonstration facilities have been installed in Italy, the Netherlands and the UK. In this thesis, a complete dynamic model of the system has been developed in the TRNSYS software, capable of reproducing the behavior of the different components and the system in general. This model is a useful tool for the development and analysis of different control strategies without the need to implement them in real installations, as well as analyses the behavior of the system operating under different conditions. For this purpose, it is necessary to develop detailed models of the new components developed in the project: the BHE and the DSHP; to couple them to the rest of the components of the system. For this reason, a dynamic model of the new BHE was developed, able to accurately reproduce its short-term behavior, focused on the evolution of the fluid temperature, and validated with experimental data in different operating conditions. In order to reproduce not only the dynamic behavior of the BHE, but also the long-term response of the ground and the interaction between BHEs in a field, another model was developed in TRNSYS. In this way, by coupling both models, it is possible to reproduce the short-term behavior of the BHE as well as the long-term response of the ground. On the other hand, a model of the DSHP was implemented in TRNSYS. With this model, it is possible to calculate the capacity of the heat pump depending on the operating mode in which it is operating, the frequency of the compressor and other variables and operating conditions. The model of the hybrid system in TRNSYS has been used to make an analysis of its behavior working in different climatic conditions, for which three cities have been selected in Spain and three in Europe, with different climates. So, different simulations of the system have been carried out in each city for one year. The efficiency of the system in each city has been analyzed, as well as the use of each of the sources (air / ground). On the other hand, one of the demo-sites of the GEOTeCH project, including the conditioned office building and the coupling with the fan coils, has also been modelled in TRNSYS. With this model, it is studied a new strategy to control the frequency of the compressor based on the temperature of the rooms, instead of controlling it based on the supply temperature, with the aim of reducing the consumption of the compressor when the rooms are already in comfort conditions. In addition, other optimization strategies have been analyzed with the model. Therefore, the models developed, both for the BHE and the system, are able to reproduce their operation and can be used as virtual installations, constituting useful tools to help in the design of the system and the different components, the analysis of their behavior and the development of optimization strategies., I would like to acknowledge the financial support that has made this PhD thesis possible. The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating), also by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)” and by the Institute for Energy Engineering of the Universitat Politècnica de València.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A novel methodology for map-based model fitting: A case study with a Dual Source Heat Pump experimental dataset

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Barceló Ruescas, Francisco|||0000-0002-0577-2662
  • Song, Yang
[EN] This paper presents a new methodology to adjust map-based models to experimental data and reports the main results of a comprehensive experimental campaign of a Dual Source Heat Pump (DSHP) prototype. The prototype tested incorporates variable speed components (compressor, circulation pumps, and fan). The novelty of this prototype lies in its ability to select two possible heat sources: air or ground. Thus, it can operate as a geothermal or aerothermal heat pump, as well as a chiller, thanks to the additional capacity to reverse the cycle. Thanks to this hybrid approach, several advantages can be obtained compared to conventional equipment, such as higher efficiency, the requirement of smaller borehole heat exchangers, or the absence of defrost cycles. In a prior study, polynomial models were developed to accurately characterize the DSHP¿s performance (i.e., condenser and evaporator capacities and electrical energy consumption). These models were obtained considering the external variables to the unit as independent variables to facilitate their applicability using variables commonly measured in real installations. Due to the complexity of heat pump performance, which in current equipment can be influenced by up to 5 or 6 independent variables, the search for suitable polynomial models required the availability of a complete working map including more than 3000 working points. Thus, this previous work developed these models based only on simulation results. In this sense, this paper concludes the development of these models by focusing on two critical issues concerning empirical model development. The first aspect involves determining the minimum number and location of testing points needed to define the experimental sample for the model adjustment. The reported experimental data were obtained by analyzing the most suitable experimental design methodology to create the experimental matrices in each operating mode of the DSHP. The second aspect focuses on the final adjustment of models using experimental data. A novel fitting approach for empirical models is introduced in the last part of this study. The developed methodology enables the integration of simulation and experimental results for the final fitting of empirical models through a two-step adjustment. The first step involves analyzing and defining polynomial functionals from the complete working maps generated by simulation. Subsequently, in a second step, the polynomial models are refitted to a suitable experimental sample using the methodology presented in this work. The latter allows for the increase of the accuracy of the models and the minimization of experimental costs. This novel approach ensures a robust characterization of systems with many independent variables using a minimum amount of experimental data. Significant benefits can be obtained from its application, such as the reduction of experimental cost and an increase in the model¿s accuracy through an effective combination of both experimental and simulated information. Furthermore, it can be considered of general applicability to other engineering problems where the characterization of physical systems influenced by a high number of independent variables is required., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014 2020) inside the framework of the project 656889 GEOTeCH (Geothermal Technology for Economic Cooling and Heating), by the project DESCARBONIZACIÓN DE EDIFICIOS E INDUSTRIAS CON SISTEMAS HÍBRIDOS DE BOMBA DE CALOR , funded by the Ministerio de Ciencia e Innovación , MCIN, Spain, with code number: PID2020-115665RB-I00 and by the postdoctoral fellowship funded by Universitat Politècnica de València inside the program Ayudas para Contratos de acceso de personal investigador doctor (PAID-10-23) . Many thanks as well to the late Dr. José Miguel Corberán, without whom this work would never have been possible. Sadly, Dr. José Miguel Corberán passed away in July of 2022. I wish to give my wholehearted support to José Miguel s family. I hope we did you proud.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

An Innovative Co-Axial Spiral Borehole Heat Exchanger Dynamic Model

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Ruiz-Calvo, Félix
  • Witte, Henk
  • Corberán, José M.
A dynamic model of a ground source heat pump (GSHP) system is a very useful tool in order to optimize its operation. It might reproduce the thermal behaviour of each component of the system both on a short-term and a long-term basis, as well as the effect that the borehole heat exchanger (BHE) has in the surrounding ground. Hence, it is possible to use this model to develop proper control strategies in order to increase the global system s efficiency as much as possible. In this work, the approach used for the recently developed B2G dynamic model has been extended to a different configuration than the standard U-tube BHE. The new configuration is a novel co-axial spiral BHE designed in the framework of the GEOT CH project (Geothermal Technology for conomic Cooling and Heating), a HORIZON 2020 European project. The model has been validated against experimental data from a real borehole located in Houten, Netherlands. The results show that the B2G approach applied to this specific configuration produces a model that can accurately predict the short-term behaviour of the BHE., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Energy Analysis and Cost-Effective Design Solutions for a Dual-Source Heat Pump System in Representative Climates in Europe

  • Milanowski, Maciej
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
[EN] Ground-source heat pumps are an efficient technology for heating and cooling in buildings. However, the main limitation of their widespread application is the borehole heat exchanger's (BHE) high investment cost. Hybridizing GSHP systems may overcome this limitation. This research work analyzes the long-term energy performance of a dual-source heat pump (DSHP) system, which uses the air or the ground as external heat/sink sources, in three representative European climates. First, a BHE cost-effective design solution is proposed for each climatology; then, a complete energy analysis is carried out, and the optimal source control parameters that best enhance the system performance in each climate are determined with the use of a complete dynamic model of the DSHP system developed in TRNSYS. Simulations were carried out for a 25-year operation period. Results show that the DSHP maintains the efficiency during the simulated period, with deviations lower than 1.7% in all cases. Finally, the source control optimization method results in only slight efficiency gains (<0.35%) but with a stronger effect on the ground/air use ratio (up to 25% use of air in cold climates), reducing the thermal imbalance of the ground and leading to a consequent BHE size length and cost reduction., This research was partly funded by the European Commission, grant number 656889.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Modelling and Experimental Validation of a Novel Co-Axial Spiral Borehole Heat Exchanger

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Witte, Henk
  • Hylkema, Roon
  • Corberán, José M.
In order to optimize the operation of a ground source heat pump (GSHP) system, the development of dynamic models that integrate all the system components is a key factor. Particularly, the modelling of the ground source heat exchanger and its coupling to the heat pump operation becomes important. Usually, this kind of systems present an on/off operation, which makes it necessary to have an accurate prediction of both the short and long thermal response of the borehole heat exchanger (BHE). In this context, the novel B2G dynamic model was developed and experimentally validated in previous works for a single U-loop BHE. This work presents the adaptation and experimental validation of the B2G dynamic model to a novel co-axial spiral BHE configuration designed in the framework of a HORIZON 2020 European Project, GEOT CH (Geothermal Technology for conomic Cooling and Heating). The results show that the B2G approach applied to this specific configuration produces a model that can accurately predict the behavior of the BHE., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

Study of Response Surface Models for the characterization of the performance in Refrigeration Equipments and Heat Pumps

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
[ES] En un contexto de creciente preocupación por el calentamiento global y de políticas energéticas internacionales, en el cual los sistemas de climatización de los edificios suponen una parte importante del consumo energético global, los sistemas de bombas de calor son considerados como opciones muy interesantes debido a su alta eficiencia y por ser fuentes de energía renovables. En este sentido, una caracterización precisa de estos equipos es de vital importancia con el objetivo de mejorar su diseño y, en aquellos casos dónde este tipo de unidades se integren como parte de sistemas más complejos, implementar estrategias de control eficientes. En este contexto, esta tesis doctoral se centra en el modelado de bombas de calor con el fin de obtener modelos que permitan conocer con precisión el desempeño global de estas unidades en todo el rango de trabajo. En la primera parte del trabajo, se han realizado numerosos ensayos experimentales utilizando un nuevo prototipo de bomba de calor dual, obtenidos dentro del marco de trabajo del proyecto europeo GEOTeCH. Debido a la tipología hibrida de esta unidad, los resultados experimentales obtenidos incluyen datos de desempeño para las principales tecnologías de bombas de calor: las bombas de calor aerotérmicas y geotérmicas. Haciendo uso de toda esta información experimental, esta primera parte del trabajo se centra en obtener modelos polinómicos para la predicción del consumo eléctrico y las capacidades de calefacción y refrigeración en función de las variables externas a la unidad. Dichas variables son fáciles de obtener y suelen medirse en instalaciones reales. Por tanto, estos modelos caracterizan a la bomba de calor como un único componente, simplificando su implementación en modelos globales de sistemas más complejos donde se instalan estas unidades. Además, seleccionado un enfoque empírico para el modelado, en esta parte también se analizan algunos aspectos relevantes, como los términos a incluir en el polinomio, o cómo conformar las matrices experimentales de ensayo necesarias, es decir, cuántos puntos experimentales realizar y dónde situarlos en el rango de operación. Por último, la segunda parte de la tesis doctoral está dedicada a modelar uno de los componentes principales en estas unidades, el compresor. En este caso, el desarrollo de una extensa base de datos que incluye numerosos ensayos calorimétricos de las dos principales tecnologías de compresores, pistón y scroll, ha permitido el análisis detallado de las superficies de respuesta del consumo eléctrico y el caudal másico de refrigerante en función de las temperaturas de evaporación y condensación. A partir de esta información y siguiendo un enfoque similar al utilizado previamente, en esta segunda parte se revisan los modelos incluidos en la norma actual de caracterización de compresores, el estándar AHRI 540 (2020), para comprobar si son adecuados o si, por el contrario, debemos utilizar otro tipo de expresiones polinómicas. También se analizan en profundidad cuestiones críticas como el número de puntos necesarios para caracterizar cada tecnología de compresor, dónde situarlos en el dominio experimental, cómo evitar un posible sobreajuste del modelo minimizando problemas de extrapolación o interpolación, o cómo extrapolar los resultados para predecir con otros refrigerantes u otras condiciones de aspiración., [CA] En un context de creixent preocupació per l'escalfament global i de polítiques energètiques internacionals, en el qual els sistemes de climatització dels edificis suposen una part important del consum energètic global, els sistemes de bombes de calor són considerats com a opcions molt interessants a causa de la seva alta eficiència i perquè són fonts d'energia renovables. En aquest sentit, una caracterització precisa d'aquests equips és de vital importància amb l'objectiu de millorar el seu disseny i, en aquells casos on aquest tipus d'unitats s'integren com a part de sistemes més complexos, implementar estratègies de control eficients. En aquest context, aquesta tesi doctoral se centra en el modelat de bombes de calor per obtenir models que permitisquen conèixer amb precisió el funcionament d'aquestes unitats a tot el rang de treball. A la primera part del treball, s'han realitzat nombrosos assajos experimentals utilitzant un nou prototip de bomba de calor dual, obtinguts dins del marc de treball del projecte europeu GEOTeCH. A causa de la tipologia hibrida d'aquesta unitat, els resultats experimentals obtinguts inclouen dades de funcionament per a les principals tecnologies de bombes de calor: les bombes de calor aerotèrmiques i geotèrmiques. Fent ús de tota aquesta informació experimental, aquesta primera part del treball se centra a obtenir models polinòmics per a la predicció del consum elèctric i les capacitats de calefacció i refrigeració en funció de les variables externes a la unitat. Aquestes variables són fàcils d'obtenir i se solen mesurar en instal·lacions reals. Per tant, aquests models caracteritzen la bomba de calor com un únic component, simplificant-ne la implementació en models globals de sistemes més complexos on s'instal·len aquestes unitats. A més, seleccionat un enfocament empíric per al modelatge, en aquesta part també s'analitzen alguns aspectes rellevants, com els termes a incloure al polinomi, o cóm conformar les matrius experimentals d'assaig necessàries, és a dir, quants punts experimentals realitzar i on situar-los al rang d'operació. Per acabar, la segona part de la tesi doctoral està dedicada al modelat d'un dels components principals d'aquestes unitats, el compressor. En aquest cas, el desenvolupament d'una extensa base de dades que inclou nombrosos assajos calorimètrics de les dues principals tecnologies de compressors, pistó i scroll, ha permès l'anàlisi detallat de les superfícies de resposta del consum elèctric i el cabal màssic de refrigerant segons les temperatures d'evaporació i de condensació. A partir d'aquesta informació i seguint un enfocament similar a l'utilitzat prèviament, en aquesta segona part es revisen els models inclosos a la norma actual de caracterització de compressors, l'estàndard AHRI 540 (2020), per comprovar si són adequats o si, per contra, cal utilitzar un altre tipus d'expressions polinòmiques. També s'analitzen en profunditat qüestions crítiques com el nombre de punts necessaris per caracteritzar cada tecnologia de compressor, on situar-los al domini experimental, cóm evitar un possible sobreajust del model minimitzant problemes d'extrapolació o interpolació, o cóm extrapolar els resultats per predir amb altres refrigerants o altres condicions d'aspiració., [EN] In a context of global warming concerns and global energy policies, in which heating and cooling systems in buildings account for a significant amount of the global energy consumption, heat pump systems are widely considered as a really interesting option for enabling high efficiency and also for being renewable energy sources. In this sense, an accurate characterization of these units is of vital importance to improve their design and implement efficient control strategies, when the unit is integrated in more complex systems. Against this background, this PhD thesis focuses on heat pump modelling in order to create map-based models able to accurately characterize the global performance of these units for the entire working range. In the first part of this work, many experimental tests have been obtained for a new Dual Source Heat Pump prototype tested in the framework of the European project GEOTeCH. Due to the dual typology, the experimental results include performance data for the two main heat pump technologies: Air Source Heat Pumps and Ground Source Heat Pumps. By using all this experimental information, this first part focuses on obtaining empirical polynomial models capable of accurately predicting energy consumption and heating and cooling capacities as a function of external variables. Such variables are easy to measure and are usually recorded in real installations. Therefore, these models characterize the heat pump as a single component, simplifying its implementation in global models of more complex systems where these units are installed. Furthermore, selecting the empirical model approach, this part also includes some critical aspects, such as how to obtain the best polynomial expression, or how to perform the required experimental test matrices, i.e., how many tests should be conducted and where in the operating range. Finally, the second part of this PhD thesis is dedicated to modelling one of the main components of these units, the compressor. In this case, the development of an extensive database including numerous calorimetric tests on the two main compressor technologies, reciprocating and scroll compressors, has allowed the detailed analysis of the response surfaces of their performance parameters, i.e., the energy consumption and mass flow rate as a function of the evaporation and condensation temperatures. Using this information, and following an approach similar to that used in the first part, this second part reviews the models included in the current compressor characterization standard, the AHRI 540 (2020), in order to check whether they are appropriate or, on the contrary, whether we should use of other types of polynomial expression. Critical issues such as the number of points needed to characterize each compressor technology, where to place them in the experimental domain, how to prevent possible overfitting in the model adjustment to minimize extrapolation or interpolation problems, or how to extrapolate results for predicting other refrigerant or suction conditions, are discussed in depth., I would like to acknowledge the financial support that has made this PhD thesis possible. The doctoral fellowship FPU15/03476 was founded by “Ministerio de Educación, Cultura y deporte” inside the program “Formación de Profesorado Universitario”, and the GEOTeCH project (No 656889) founded by the European Union under the “Horizon 2020 Framework Programme for European Research and Technological Development”
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Modelling and energy analysis of a dual source heat pump system in an office building

  • Corberán, José M.
  • Masip Sanchis, Ximo
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
This paper presents the modelling and energy analysis of a dual source heat pump system for the production of heating, cooling and domestic hot water (DHW) in buildings. The research work was carried out in the framework of the Geot€ch project ‘GEOthermal Technology for economic Cooling and Heating’. The Geot€ch project, funded by the European commission within the H2020 program, is a four years’ duration project which demonstrates the next generation of ground source heat pump systems with a high energy efficiency but also with lower system costs with respect to those already existing in the market. To this end, one of the objectives of the project is the design of an efficient and comparative low cost ‘plug& play’ system for providing the heating, cooling and DHW needs in three demonstration sites located in Italy, the United Kingdom and the Netherlands respectively. In this context, an innovative dual source heat pump has been developed, which is capable of making optimal use of ground or air environmental heat sources according to operating and climate conditions. On the other hand, in order to reduce the costs of the installation, a new more efficient technology of coaxial borehole heat exchangers will be developed within the framework of the project. The project started on May 2015 and it is still ongoing. This paper first describes the characteristics of the dual source heat pump designed in the project. Then, in order to assist both in the optimal design and energy optimization of the operation of the system, a model of the ‘plug&play’ system in TRNSYS including all the integrated system components (dual source heat pump, ground source heat exchanger, air conditioning and DHW hydraulic loops) is presented for the demo site located in the Netherlands. Finally, the paper presents an analysis of the system operation as well as a first energy assessment in order to identify key control strategies needed to optimize the seasonal energy performance of the system., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dual source heat pump, a high efficiency and cost-effective alternative for heating, cooling and DHW production

  • Corberán, José M.
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
[EN] This article presents the characteristics and performance of an innovative dual source heat pump (DSHP) for heating, cooling and domestic hot water (DHW) production. The research work was carried out in the framework of the H2020 European project: Geot€ch `GEOthermal Technology for economic Cooling and Heating¿. The DSHP is able to choose the most favourable source/sink in such a way that it can work as an air-to-water heat pump using the air as a source/sink, or as a brine-to-water heat pump coupled to the ground. The DSHP is manufactured as an outdoor `plug & play¿ unit, working with R32 refrigerant and including a variable speed compressor, which gives full capabilities for an efficient modulating operation. The DSHP was fully characterized in steady state conditions at the IUIIE laboratory. In order to assess its dynamic performance and to identify key control strategies to optimize its annual operation, a complete integrated model of the DSHP system in TRNSYS including the DSHP and all the other system components was developed. A first energy assessment, carried out for an office building located in the Netherlands, proves that the DSHP system would be able to reach a similar efficiency than a pure ground source heat pump (GSHP) system with half the ground source heat exchanger area needed. Therefore, the DSHP system could become a cost-effective alternative solution for heating, cooling and DHW production in buildings, as the initial investment would be significantly reduced compared to GSHPs, with similar or even higher energy efficiency., The present work has been supported by the European Union under the Horizon 2020 Framework Programme for European Research and Technological Development (2014-20) inside the framework of the project 656889-GEOTeCH (Geothermal Technology for Economic Cooling and Heating). Additionally, funding was received by the Generalitat Valenciana inside the programme 'Ayudas para la contratacion de personal investigador en formacion de caracter predoctoral (ACIF/2016/131)' and by the Ministerio de Educacion, Cultura y Deporte inside the programme 'Formacion de Profesorado Universitario (FPU15/03476)'.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Modeling, analysis and energy optimization of an air source heat pump system for SHW production

  • Masip Sanchis, Ximo
  • Corberán, José M.
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
In order to fulfill with the European normative EN-1717:2000 regarding the general requirements of devices to prevent pollution of potable water by backflow, in those systems using a heat pump (HP) for the production of sanitary hot water (SHW), the coupling of the HP with the storage tank must be indirect. This paper will analyze three of the possible coupling configurations for the case of an air source heat pump system: (i) external brazed plate heat exchanger, (ii) coil heat exchanger inside the storage tank and (iii) double wall condenser at the heat pump. The system will be modeled using a dynamic simulation tool (TRNSYS). The aim of this work is to compare the energy performance of each configuration and to optimize its operation., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating), by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)” and by the Ministerio de Educación, Cultura y Deporte inside the programme ‘Formación de Profesorado Universitario (FPU15/03476)’
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

TRNSYS modelling and energy assessment of a dual source heat pump system

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Corberán, José M.
Ground source heat pump systems are recognized as one of the most energy efficient renewable systems for heating, cooling and domestic hot water production in buildings. However, the high cost of the Ground Source Heat Exchanger (GSHE) is still a handicap for its widespread use in Europe. In this context, the use of an innovative dual source (air/ground) heat pump developed in the framework of the H2020 Geot ch project could contribute to reduce both the total size of the GSHE and the annual energy consumption of this type of systems. This is possible thanks to the heat pump capability of selecting the most favourable source/sink, with a consequent lower amount of heat exchange needed with the ground. However, the convenience of considering this type of systems is not always straightforward, as it depends on the type of climatological conditions, the thermal demand profile and the ground thermal properties. This assessment is carried out, by means of a complete model developed in TRNSYS, for three different cities in Spain., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating), by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)” and by the Ministerio de Educación, Cultura y Derporte inside the program “Formación de Profesorado Universitario (FPU15/03476)”
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Diseño de una bomba de calor de 8 kW con foco de calor dual: aerotermia y geotermia

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Corberán, José M.
Debido a la actual preocupación por la preservación del medio ambiente y la reducción de emisiones de CO2, los fabricantes de equipos frigoríficos y bombas de calor invierten mucho tiempo en diseños más eficientes, que cumplan con la actual normativa para el uso de refrigerantes con menor Potencial de Calentamiento Atmosférico (PCA). Nace así el proyecto GEOTeCH, financiado por la Comisión Europea dentro del programa H2020, con el objetivo de encontrar soluciones constructivas para las bombas de calor del futuro, más eficientes y respetuosas con el medio ambiente. Este artículo describe las etapas de diseño de una innovadora bomba de calor dual con dos posibles fuentes de calor: geotérmica y aerotérmica. El diseño final es capaz de funcionar con la máxima eficiencia dando servicio independiente de refrigeración, calefacción y producción de agua caliente sanitaria durante todo el año, haciendo uso de R32 como refrigerante., El presente trabajo cuenta con financiación de la Unión Europea en el marco del Programa Marco Horizonte 2020 de Investigación y Desarrollo Tecnológico Europeo (2014-2020) en el marco del proyecto 656889 GEOTeCH (Geothermal Technology for Economic Cooling and Heating). También se ha recibido financiación por parte de la Generalitat Valenciana en el marco del programa 'Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF / 2016/131)' y por parte del Ministerio de Educación, Cultura y Deporte dentro del programa Formación de Profesorado Universitario (FPU15/03476)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A novel TRNSYS type of a coaxial borehole heat exchanger for both short and mid term simulations: B2G model

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Tinti, Francesco
  • Corberán, José M.
[EN] A dynamic model of a ground source heat pump system is a very useful tool in order to optimize its design and operation. In order to fairly predict the performance of such a system, the dynamic evolution of the fluid entering the heat pump and coming from the borehole heat exchanger (BHE) must be accurately reproduced not only in the long term but also in the short-mid term operating conditions, as it directly affects the coefficient of performance of the heat pump unit. In this context, the B2G model was developed to reproduce the short-term dynamic evolution of the fluid temperature inside the BHE. This work presents the new upgraded version of the B2G dynamic model for a coaxial BHE, which includes several new features to better reproduce not only the short-term but also the mid-term behaviour of the BHE. For that purpose, the model of the surrounding ground has been improved: vertical heat conduction in the grout and ground, heterogenous ground with different layers, and a higher number of ground nodes in the thermal network considered in the model were added, which are automatically located by means of polynomial correlations for any type of ground, geometry and operating conditions. This novel approach has been implemented in TRNSYS for accurately modelling the dynamic behaviour of a coaxial BHE with low computational cost (2.5¿s for a 24¿h simulation period in a modern computer). The model has been validated against experimental data from a dual source heat pump installation in Tribano (Padua, Italy) and has proven capable of accurately reproducing the short-mid term (up to five days) behaviour of the BHE, with a deviation lower than 0.12¿K., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 –GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Estimating Ground Thermal Properties of a Borehole Heat Exchanger using the B2G Dynamic Model

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montero Reguera, Álvaro Enrique|||0000-0002-4165-4743
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Ruiz-Calvo, Félix
  • Martos Torres, Julio
  • Corberán, José M.
In situ thermal response tests (TRT s) are currently the standard methodology used for determining ground thermal properties needed for sizing ground source heat exchangers (GSHE). The main drawback of this methodology is the high cost involved, mainly due to the long injection times needed. Since ground conductivity is a key parameter in the design of a GSHE, any advances in the reduction of the duration of a TRT would result in a lower cost. Hence, the viability of this kind of test would increase. In this context, a dynamic model of the GSHE can be very useful to reduce the amount of data needed in order to obtain the ground thermal properties. The recently developed B2G model has proven to be able to reproduce the short-term response of a GSHE with a great accuracy. One of the main advantages of the B2G dynamic model is that it can be adjusted to any specific GSHE with only a few experimental data (typically, corresponding to 10-15 hours of heat injection/extraction). This model could be used to provide an estimation of the ground thermal properties using less data than a standard TRT. In this work, the B2G model has been adapted to an existing borehole heat exchanger (BHE) located at Universitat Politècnica de València. Experimental data corresponding to a TRT performed in this BHE have been used in order to validate the adaptability of the B2G model and its utility as a ground thermal properties estimation tool., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development and Experimental Validation of a TRNSYS Dynamic Tool for Design and Energy Optimization of Ground Source Heat Pump Systems

  • Ruiz-Calvo, F.
  • Corberán, José M.
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
[EN] Ground source heat pump (GSHP) systems stand for an efficient technology for renewable heating and cooling in buildings. To optimize not only the design but also the operation of the system, a complete dynamic model becomes a highly useful tool, since it allows testing any design modifications and different optimization strategies without actually implementing them at the experimental facility. Usually, this type of systems presents strong dynamic operating conditions. Therefore, the model should be able to predict not only the steady-state behavior of the system but also the short-term response. This paper presents a complete GSHP system model based on an experimental facility, located at Universitat Politècnica de València. The installation was constructed in the framework of a European collaborative project with title GeoCool. The model, developed in TRNSYS, has been validated against experimental data, and it accurately predicts both the short- and long-term behavior of the system., The present work has been supported by the FP7 European project "Advanced ground source heat pump systems for heating and cooling in Mediterranean climate" (GROUND-MED), and by the Generalitat Valenciana inside the program "Ayudas para la contratacion de personal investigador en formacion de caracter predoctoral (ACIF/2016/131)". A particular mention is given to the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020), who has covered the costs to publish this work and funded part of this research inside the framework of the project 656889-GEOTeCH (Geothermal Technology for Economic Cooling and Heating).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Seasonal performance assessment of a Dual Source Heat Pump system for heating, cooling and domestic hot water production

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Corberán, José M.
In order to contribute to a global CO2 emissions reduction in 2020, the increase in the use of highly efficient heat pumps for heating, cooling and domestic hot water production in buildings is very recommendable. In this direction, Ground Source Heat Pump (GSHP) systems are generally recognized as one of the most energy-efficient compared to air source heat pump systems. However, this strongly depends on the temperature evolution of the air and the ground during the year, which also depends on the geographical location of the system. Therefore, an optimal system from the energy point of view apparently would be the one that is able to switch from one source to the other in order to operate the heat pump with the highest efficiency. In this context, a new Dual Source Heat Pump (DSHP) unit for heating, cooling and production of domestic hot water, was developed and manufactured in the framework of a H2020 European project called GEOT CH (Geothermal Technology for conomic Cooling and Heating). This paper presents the assessment of such a DSHP in different representative locations around Europe. For this purpose, an integrated system model in TRNSYS was developed to assess its performance for different thermal demand profiles obtained for the same building under different conditions., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating), by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)” and by the Ministerio de Educación, Cultura y Derporte inside the program “Formación de Profesorado Universitario (FPU15/03476)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Influence of Different Ground Thermal Properties in a Borehole Heat Exchanger s Performance Using the B2G Dynamic Model

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Montero Reguera, Álvaro Enrique|||0000-0002-4165-4743
  • Martos Torres, Julio
  • Corberán, José M.
Ground source heat pump (GSHP) systems for heating and cooling represent an efficient alternative to conventional air source heat pump systems, always provided that they present an efficient design and operation. In this context, the development of energy optimization strategies becomes essential, with the aid of integrated dynamic models of the system, specially the ground source heat exchanger. In previous works, a single U borehole heat exchanger (BHE) dynamic model, called Borehole-to-Ground (B2G), was developed and experimentally validated. The B2G model is based on the thermal network approach, combined with a vertical discretization of the borehole. However, the thermal properties of the surrounding ground were modelled as an average, constant with depth. For homogeneous type of soils, this assumption might be acceptable but, when considering heterogeneous type of soils, modelling the presence of different layers with different materials could provide more accurate results. In this work, the B2G model has been adapted in order to account for the effect of a heterogeneous ground profile on the fluid temperature evolution along the borehole depth. Experimental data corresponding to a Thermal Response Test (TRT) performed in a real BHE existing at the Universitat Politècnica de València, were used to validate this new feature of the B2G model. Finally, it is concluded that the model can serve as a ground thermal properties estimation tool., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Initial test campaign of an innovative dual source heat pump

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Corberán, José M.
This paper describes the experimental setup and the test campaign performed on an innovative prototype of reversible dual source heat pump, with aerothermal and geothermal heat sources working with R32 as refrigerant. The addition of the air source allows the use each time of the most convenient source, hence leading to a considerably higher efficiency, as well as to dramatically reducing the size of the ground source heat exchanger so that the initial cost is much lower than the one of a full geothermal heat pump installation. The design and construction of this unit is the result of the research carried out under the frame of the GEOTeCH, project funded by the European Commission under the H2020 program. This paper first describes the employed experimental setup, and then presents the definition of the test matrix for the characterization of the heat pump performance under each operation mode, which has been based on the Design of Experiments methodology in order to minimize as much as possible the number of test points. 227 test points were acquired, what has allowed the characterization of the unit performance in all operation modes and a broad range of operating conditions, through adequate Response Surfaces. Finally, a comparison of the experimental performance results with the calculations performed with IMST-ART software is presented., The present work has been supported by the European Union under the Horizon 2020 Framework Programme for European Research and Technological Development (2014–20) inside the framework of the project 656889— EOTeCH (Geothermal Technology for Economic Cooling and Heating). Additionally, funding was received by the Generalitat Valenciana inside the programme ‘Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)’ and by the Ministerio de Educación, Cultura y Deporte inside the programme ‘Formación de Profesorado Universitario (FPU15/03476)’
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Adaptation of the B2G dynamic model to new borehole heat exchanger coaxial configurations

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Corberán, José M.
In order to reach a global reduction in the CO2 emissions, it is key to improve the energy efficiency of systems for producing heating and cooling in buildings. This can be achieved by increasing the use of renewable energies, for instance ground source heat pumps (GSHP). However, special attention should be paid to its optimal design and operation. In this context, the development of dynamic models is a key factor, being the model of the ground source heat exchanger and its coupling to the heat pump particularly important. This coupling needs to be well reproduced both in the short term and long term operation, given that most of the GSHP systems have an on/off operation. In this context, the novel B2G dynamic model was developed and experimentally validated previously for a single U-loop BHE. This work presents the adaptation and experimental validation of the B2G model both to a standard coaxial configuration and to a novel coaxial spiral configuration., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Characterization of the performance for water-to-water and air-to-water heat pumps: Development of simple and compact polynomial correlations

  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Corberán, José M.
  • Llopis, Belén
Nowadays, the development of models is one of the most common problems in many research studies. In the field of refrigeration and heating, researchers increasingly require compact models with a reduced computational time. These models must be able to predict the performance of heat pumps and chillers with reasonable accuracy. This paper describe the development of simple and compact polynomial models for the performance characterization in these machines. To this end, this study consists of two main parts: Obtaining the polynomial models and then its final adjustment with experimental data. The unit selected for this study, is an innovative prototype of reversible dual source heat pump, with aerothermal and geothermal heat sources working with R32 as refrigerant. This has enabled us to analyze the response surface for the performance of the two main heat pump technologies: water-to-water and air-to-water heat pumps., The present work has been supported by the European Union under the Horizon 2020 Framework Programme for European Research and Technological Development (2014–20) inside the framework of the project 656889—GEOTeCH (Geothermal Technology for Economic Cooling and Heating). Additionally, funding was received by the Ministerio de Educación, Cultura y Deporte inside the programme ‘Formación de Profesorado Universitario (FPU15/03476)’.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Upgrade of the B2G dynamic geothermal heat exchanger model: optimal location of the ground nodes

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla
  • Corberán, José M.
  • Tinti, Francesco
  • Focaccia, Sara
In order to optimize the design and operation of a ground source heat pump system, the modeling of the Borehole Heat Exchanger (BHE) and its coupling to the heat pump operation becomes crucial. This becomes key for those systems with on/off operation, where it is important to model the short-term response of the BHE accurately. Furthermore, the modeling of the local variation of the ground temperature near the BHE will be highly influenced by ground thermal properties and the operation of the system. In this context, the novel B2G dynamic model was developed and experimentally validated in previous works for a single U BHE and adapted to a novel coaxial spiral configuration. In order to consider the influence of the soil surrounding the BHE, two ground nodes were initially defined and their position (penetration radii) was calculated for a specific type of soil and operating conditions. This paper presents an upgrade of the B2G model, with a descripton of penetration radii calculation. For this purpose, a comparison between the B2G model and the Infinite Cylindrical Source model was carried out to find the penetration radii that reproduce the ground thermal response with a higher accuracy under the corresponding soil thermal properties and operating conditions., The present work has been supported by the European Community Horizon 2020 Program for European Research and Technological Development (2014-2020) inside the framework of the project 656889 – GEOTeCH (Geothermal Technology for Economic Cooling and Heating) and by the Generalitat Valenciana inside the program “Ayudas para la contratación de personal investigador en formación de carácter predoctoral (ACIF/2016/131)”
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Nuevo modelo dinámico de un intercambiador enterrado en TRNSYS: adaptación del modelo B2G a largos periodos de simulación

  • Cazorla-Marín, Antonio|||0000-0003-3314-0395
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
  • Ruiz-Calvo, Félix
  • Corberán, José M.
El uso de modelos que simulen el comportamiento de una instalación está ampliamente extendido como ayuda en el diseño y optimización de sistemas de climatización. En un sistema de bomba de calor geotérmica, el intercambiador enterrado es uno de los componentes más importantes, y uno de los más complejos de modelar. Existe una gran variedad de modelos de intercambiador enterrado. La mayoría de los modelos existentes se centran en modelar el comportamiento a corto o a largo plazo. Por otra parte, existen algunos modelos que engloban tanto el corto como el largo plazo; sin embargo, estos requieren un coste computacional muy alto. En el presente trabajo, se presenta el modelado de un intercambiador enterrado situado en la Universitat Politècnica de València, el cual consiste en la utilización de un nuevo modelo dinámico (B2G) desarrollado en TRNSYS que simula el comportamiento del intercambiador enterrado con una gran precisión y un coste computacional bajo, a corto plazo. Para modelar el largo plazo, se propone acoplar el B2G a otro modelo ya existente y ampliamente conocido. Se consideran dos modelos de largo plazo distintos: el modelo DST existente en TRNSYS y el modelo g-function. Finalmente, se comparan los resultados de simulación en ambos casos. Los resultados obtenidos muestran que el modelo B2G acoplado a cualquiera de los dos modelos a largo plazo estudiados reproduce con gran precisión el comportamiento real del intercambiador. Esto refleja su alta versatilidad, ya que puede trabajar combinado con diferentes modelos de intercambiador enterrado a largo plazo, Este trabajo ha sido financiado por el proyecto europeo del programa Horizonte 2020 “Geothermal Technology for €conomic Cooling and Heating” (GEOT€CH)