Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies

  • Velarte, A.
  • Otín, A.
  • Pueyo, E.
  • Guimera, A.
  • Villa, R.
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Right ventricular vs left bundle branch pacing-induced changes in ECG depolarization and repolarization

  • Sales Bellés, Clara
  • Palacios, Saúl
  • Melero, Jorge
  • Julián, Inés
  • Ramos, Javier
  • Pablo Martínez, Juan
  • Minchole, Ana
  • Pueyo, Esther
Patients suffering from bradycardia are indicated for pacemaker implantation. Right ventricular pacing (RVP)has been conventionally used for this purpose, but it can increase the risk of atrial fibrillation and heart failure. Left bundle branch area pacing (LBBAP) has been proposed as a new physiological pacing technique. The aim of this study was to compare changes induced by RVP and LBBAP in the ECG. 10-minute 12-lead ECG recordings were acquired at baseline and after pacemaker implantation from 83 patients (31 RVP, 52 LBBAP). Median beats were calculated for each patient at baseline and post-implantation states. ECG markers including QRS duration (dQRS)and area (aQRS) and heart rate-corrected QT (QTc) and Tpeak-to-Tend (Tpec) intervals were measured. dQRS and aQRS decreased significantly at post-implantation with respect to baseline, both being significantly lower for LBBAP than RVP after pacemaker implantation. QTc was significantly reduced at post-implantation for both pacing techniques with no differences between them. Tpec did not change either between states or techniques. In conclusion, LBBAP led to more synchronized ventricular depolarization, supporting potentially improved clinical outcomes with LBBAP as compared to RVP for anti-bradycardia therapy
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Characterization of the effects of right ventricular and left bundle branch area pacing on the QRS complex

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Vadillo Martin, P
  • Mayo Carlos, V
  • Palacios Rosales, S
  • Martinez Cortes, J P
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Right ventricular pacing (RVP) has been the treatment of choice for patients with atrioventricular block and sinus node disease for the last decades . It is well known that RVP ventricular may cause ventricular dyssynchrony and could lead to left ventricular dysfunction in 20% of patients, and therefore could increase the risk of heart failure, atrial fibrillation and cardiovascular mortality. Left bundle branch area pacing (LBBAP) has recently emerged as a new physiological pacing modality that can circumvent the limitations of RVP. The purpose of this study was to compare changes induced by RVP and LBBAP in the standard 12-lead ECG by the analysis of QRS complex characteristics in order to asses ventricular dyssynchrony. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) with indication for anti-bradycardia therapy were acquired before and after pacemaker implantation. Patients were grouped into narrow and wide baseline QRS using a threshold for the QRS duration of 120 ms. Median beats were calculated at baseline and 24 hours post-implantation states for each patient. ECG markers describing ventricular activation were measured, including: 1) QRS duration (QRSd) from QRS onset to QRS end; 2) QRS area (QRSa), computed from the individual areas in orthogonal X, Y and Z leads calculated using the Kors conversion matrix; 3) a new index QRS50 proposed to estimate the ventricular activation time from the first three components of the singular value decomposition of the median QRS complex. Results: Note that the QRS characteristics showed similar values in baseline for both pacing techniques. In patients with narrow QRS, we found that paced QRS characteristics remained similar from the basal QRS in LBBAP group whereas in RVP group they worsened. The three markers, QRSd, QRSa and QRS50, increased after RVP by 34 ms, 68 uVs and 22 ms, respectively (p<0,001). In patients with wide QRS, LBBAP significantly reduced QRSd, QRSa and QRS50 while RVP increased QRSa and QRS50 and left QRSd unchanged. Conclusion: In patients receiving a pacemaker for anti-bradycardia therapy, LBBAP led to more synchronized ventricular activation than RVP measured from QRS duration- and area-related characteristics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Depolarization-repolarization synchrony after right ventricular and left bundle branch area pacing

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Left bundle branch area pacing (LBBAP) has been recently proposed to overcome the limitations associated with right ventricular pacing (RVP) and has been suggested as a new physiological pacing form with high feasibility and safety. A greater difference between QRS complex and T-wave angle directions has been proposed as a marker of abnormal electrical activity in several patient populations, but a comparison between these two pacing modalities has never been performed. The total cosine R to T (TCRT) is an ECG descriptor that accounts for depolarization-repolarization synchrony by measuring the difference between their directions. The purpose of this study was to compare TCRT in patients referred for RVP and LBBAP pacing as anti-bradycardia therapy. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) were classified into two groups, narrow QRS and wide QRS, depending on the patient’s QRS duration prior to implantation. In the post-implantation state, the TCRT index was calculated from a median beat calculated for each patient. Singular value decomposition was applied to the median beat in the eight independent ECG leads (I, II, V1, V2, V3, V4, V5, V6). The QRS complex and T wave loops in a three-dimensional space were determined from the first three components of the decomposition. TCRT was computed as the average of the cosines of the angles between the QRS complex directions and the maximum T wave direction. More positive values corresponded to more synchronized depolarization and repolarization processes while more negative values indicated larger differences in the orientation of the QRS and T wave loops and, therefore, greater dyssynchronization. Results: showed that TCRT took negative values for both techniques, RVP and LBBAP, and both groups, narrow and wide QRS, indicating that pacing generated dyssynchronization between ventricular depolarization and repolarization. Nevertheless, TCRT values for both groups were significantly more negative (p<0.01) for RVP than for LBBAP. We hypothesize that cardiac memory induced by pacing could account for these negative TCRT values. In any case, LBBAP did not increase the difference in the QRS complex and T wave loop orientations as much as RVP. Conclusion: LBBAP induces less dyssynchrony than RVP in the depolarization-repolarization process.