Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 44
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis of age-related left ventricular collagen remodeling in living donors: Implications in arrhythmogenesis

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Mountris, Konstantinos
  • Duwé, Sam
  • Smisdom, Nick
  • Pérez, Marta
  • Luján, Lluis
  • Wolfs, Esther
  • Driesen, Ronald B.
  • Vallejo-Gil, José María
  • Fresneda-Roldán, Pedro Carlos
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Matamala-Adell, Marta
  • Sorribas-Berjón, Juan Fernando
  • Bellido-Morales, Javier André
  • Mancebón-Sierra, Francisco Javier
  • Vaca-Núñez, Alexander Sebastián
  • Ballester-Cuenca, Carlos
  • Oliván-Viguera, Aida
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Age-related fibrosis in the left ventricle (LV) has been mainly studied in animals by assessing collagen content. Using second-harmonic generation microscopy and image processing, we evaluated amount, aggregation and spatial distribution of LV collagen in young to old pigs, and middle-age and elder living donors. All collagen features increased when comparing adult and old pigs with young ones, but not when comparing adult with old pigs or middle-age with elder individuals. Remarkably, all collagen parameters strongly correlated with lipofuscin, a biological age marker, in humans. By building patient-specific models of human ventricular tissue electrophysiology, we confirmed that amount and organization of fibrosis modulated arrhythmia vulnerability, and that distribution should be accounted for arrhythmia risk assessment. In conclusion, we characterize the age-associated changes in LV collagen and its potential implications for ventricular arrhythmia development. Consistency between pig and human results substantiate the pig as a relevant model of age-related LV collagen dynamics. © 2022 The Author(s)
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Modelización matemática y simulación computacional de la variabilidad espacio-temporal en la actividad eléctrica cardíaca

  • Pueyo Paules, Esther
The electrical activity of the heart is the result of complex biophysical and biochemical processes occurring at different scales ranging from submicroscopic to macroscopic. The variability arising from these processes has important effects on cardiac function under both physiological and pathological conditions. In this review, mathematical modeling and simulation of cardiac electrical variability at the level of the cell, tissue and whole organ will be reviewed. A set of studies will be presented, which investigate the role that the stochastic gating of ion channels of cardiac cell membranes plays in the generation of electrical voltage variations along time. Also, methodologies for the development, calibration and evaluation of populations of mathematical models able to represent variations in cardiac electrophysiology across space, i.e. among cells, tissues or individuals, will be described. In particular, methods based on state-space representations, dimension reduction techniques and nonlinear adaptive filtering will be presented and their capacity to replicate experimentally measured spatio-temporal variability will be illustrated. The importance of these methodologies will be shown as a means to ascertain the mechanisms underlying variability, to establish the link between variability and cardiac arrhythmias (irregularities in heart beating) and to propose clinical markers for diagnosis, monitoring and treatment of cardiac diseases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Dynamical mechanism for generation of arrhythmogenic early afterdepolarizations in cardiac myocytes: insights from in silico electrophysiological models

  • Barrio, R.
  • Martínez, M. A.
  • Serrano, S.
  • Pueyo, E.
We analyze the dynamical mechanisms underlying the formation of arrhythmogenic early afterdepolarizations (EADs) in two mathematical models of cardiac cellular electrophysiology: the Sato et al. biophysically detailed model of a rabbit ventricular myocyte of dimension 27 and a reduced version of the Luo-Rudy mammalian myocyte model of dimension 3. Based on a comparison of the two models, with detailed bifurcation analysis using spike-counting techniques and continuation methods in the simple model and numerical explorations in the complex model, we locate the point where the first EAD originates in an unstable branch of periodic orbits. These results serve as a basis to propose a conjectured scheme involving a hysteresis mechanism with the creation of alternans and EADs in the unstable branch. This theoretical scheme fits well with electrophysiological experimental data on EAD generation and hysteresis phenomena. Our findings open the door to the development of novel methods for pro-arrhythmia risk prediction related to EAD generation without actual induction of EADs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Meshless electrophysiological modeling of cardiac resynchronization therapy—benchmark analysis with finite-element methods in experimental data

  • Albors, C.
  • Lluch, È.
  • Gomez, J. F.
  • Cedilnik, N.
  • Mountris, K. A.
  • Mansi, T.
  • Khamzin, S.
  • Dokuchaev, A.
  • Solovyova, O.
  • Pueyo, E.
  • Sermesant, M.
  • Sebastian, R.
  • Morales, H. G.
  • Camara, O.
Computational models of cardiac electrophysiology are promising tools for reducing the rates of non-response patients suitable for cardiac resynchronization therapy (CRT) by optimizing electrode placement. The majority of computational models in the literature are mesh-based, primarily using the finite element method (FEM). The generation of patient-specific cardiac meshes has traditionally been a tedious task requiring manual intervention and hindering the modeling of a large number of cases. Meshless models can be a valid alternative due to their mesh quality independence. The organization of challenges such as the CRT-EPiggy19, providing unique experimental data as open access, enables benchmarking analysis of different cardiac computational modeling solutions with quantitative metrics. We present a benchmark analysis of a meshless-based method with finite-element methods for the prediction of cardiac electrical patterns in CRT, based on a subset of the CRT-EPiggy19 dataset. A data assimilation strategy was designed to personalize the most relevant parameters of the electrophysiological simulations and identify the optimal CRT lead configuration. The simulation results obtained with the meshless model were equivalent to FEM, with the most relevant aspect for accurate CRT predictions being the parameter personalization strategy (e.g., regional conduction velocity distribution, including the Purkinje system and CRT lead distribution). © 2022 by the authors. Licensee MDPI, Basel, Switzerland.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Fabrication of human myocardium using multidimensional modelling of engineered tissues

  • Montero-Calle, Pilar
  • Flandes-Iparraguirre, María
  • Mountris, Konstantinos
  • S de la Nava, Ana
  • Laita, Nicolás
  • Rosales, Ricardo M
  • Iglesias-García, Olalla
  • de-Juan-Pardo, Elena M
  • Atienza, Felipe
  • Fernández-Santos, María Eugenia
  • Peña, Estefanía
  • Doblaré, Manuel
  • Gavira, Juan J
  • Fernández-Avilés, Francisco
  • Prósper, Felipe
  • Pueyo, Esther
  • Mazo, Manuel M
Biofabrication of human tissues has seen a meteoric growth triggered by recent technical advancements such as human induced pluripotent stem cells (hiPSCs) and additive manufacturing. However, generation of cardiac tissue is still hampered by lack of adequate mechanical properties and crucially by the often unpredictable post-fabrication evolution of biological components. In this study we employ melt electrowriting (MEW) and hiPSC-derived cardiac cells to generate fibre-reinforced human cardiac minitissues. These are thoroughly characterized in order to build computational models and simulations able to predict their post-fabrication evolution. Our results show that MEW-based human minitissues display advanced maturation 28 post-generation, with a significant increase in the expression of cardiac genes such as MYL2, GJA5, SCN5A and the MYH7/MYH6 and MYL2/MYL7 ratios. Human iPSC-cardiomyocytes are significantly more aligned within the MEW-based 3D tissues, as compared to conventional 2D controls, and also display greater expression of C ×43. These are also correlated with a more mature functionality in the form of faster conduction velocity. We used these data to develop simulations capable of accurately reproducing the experimental performance. In-depth gauging of the structural disposition (cellular alignment) and intercellular connectivity (C ×43) allowed us to develop an improved computational model able to predict the relationship between cardiac cell alignment and functional performance. This study lays down the path for advancing in the development of in silico tools to predict cardiac biofabricated tissue evolution after generation, and maps the route towards more accurate and biomimetic tissue manufacture.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cardiac cells stimulated with an axial current-like waveform reproduce electrophysiological properties of tissue fibers

  • Monasterio, Violeta
  • Pueyo, Esther
  • Rodríguez-Matas, José Félix
  • Carro, Jesús
Background and objective: In silico electrophysiological models are generally validated by comparing simulated results with experimental data. When dealing with single-cell and tissue scales simultaneously, as occurs frequently during model development and calibration, the effects of inter-cellular coupling should be considered to ensure the trustworthiness of model predictions. The hypothesis of this paper is that the cell-tissue mismatch can be reduced by incorporating the effects of conduction into the single-cell stimulation current. Methods: Five different stimulation waveforms were applied to the human ventricular O'Hara-Rudy cell model. The waveforms included the commonly used monophasic and biphasic (symmetric and asymmetric) pulses, a triangular waveform and a newly proposed asymmetric waveform (stimulation A) that resembles the transmembrane current associated with AP conduction in tissue. A comparison between single-cell and fiber simulated results was established by computing the relative difference between the values of AP-derived properties at different scales, and by evaluating the differences in the contributions of ionic conductances to each evaluated property. As a proof of the benefit, we investigated multi-scale differences in the simulation of the effects induced by dofetilide, a selective IKr blocker with high torsadogenic risk, on ventricular repolarization at different pacing rates. Results: Out of the five tested stimulation waveforms, stimulation A produced the closest correspondence between cell and tissue simulations in terms of AP properties at steady-state and under dynamic pacing and of ionic contributors to those AP properties. Also, stimulation A reproduced the effects of dofetilide better than the other alternative waveforms, mirroring the ’beat-skipping’ behavior observed at fast pacing rates in experiments with human tissue. Conclusions: The proposed stimulation current waveform accounts for inter-cellular coupling effects by mimicking cell excitation during AP conduction. The proposed waveform improves the correspondence between simulation scales, which could improve the trustworthiness of single-cell simulations without adding computational cost. © 2022
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Physical activity in centenarians beyond cut-point-based accelerometer metrics

  • Hernández-Vicente, A.
  • Marín Puyalto, J.
  • Pueyo, E.
  • Vicente Rodríguez, G.
  • Garatachea, N.
This study described and compared physical activity (PA) characteristics at the end of the human lifespan using conventional cut-point-based versus cut-point-free accelerometer metrics. Eighteen institutionalized centenarians (101.5 ± 2.1 years, 72.2% female, 89% frail) wore the wrist GENEActiv accelerometer for 7 days. Conventional metrics, such as time spent in light-intensity PA (LiPA) and moderate-to-vigorous intensity PA (MVPA) were calculated according to published cut-points for adults and older adults. The following cut-point-free metrics were evaluated: average acceleration, intensity gradient and Mx metrics. Depending on the cut-point, centenarians accumulated a median of 15–132 min/day of LiPA and 3–15 min/day of MVPA. The average acceleration was 9.2 mg [Q1: 6.7 mg–Q3: 12.6 mg] and the intensity gradient was −3.19 [−3.34–−3.12]. The distribution of Z-values revealed positive skew for MVPA, indicating a potential floor effect, whereas the skew magnitude was attenuated for cut-point-free metrics such as intensity gradient or M5. However, both cut-point-based and cut-point-free metrics were similarly positively associated with functional independence, cognitive and physical capacities. This is the first time that PA has been described in centenarians using cut-point-free metrics. Our results suggest that new analytical approaches could overcome cut-point limitations when studying the oldest-old. Future studies using these new cut-point-free PA metrics are warranted to provide more complete and comparable information across groups and populations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A meshless fragile points method for rule-based definition of myocardial fiber orientation

  • Mountris, Konstantinos A.
  • Pueyo, Esther
Background and objective: Rule-based methods are commonly used to estimate the arrangement of myocardial fibers by solving the Laplace problem with appropriate Dirichlet boundary conditions. Existing algorithms are using the Finite Element Method (FEM) to solve the Laplace–Dirichlet problem. However, meshless methods are under development for cardiac electrophysiology simulation. The objective of this work is to propose a meshless rule based method for the determination of myocardial fiber arrangement without requiring a mesh discretization as it is required by FEM. Methods: The proposed method employs the Fragile Points Method (FPM) for the solution of the Laplace–Dirichlet problem. FPM uses simple discontinuous trial functions and single-point exact integration for linear trial functions that set it as a promising alternative to the Finite Element Method. We derive the FPM formulation of the Laplace–Dirichlet and we estimate ventricular and atrial fiber arrangements according to rules based on histology findings for four different geometries. The obtained fiber arrangements from FPM are compared with the ones obtained from FEM by calculating the angle between the fiber vector fields of the two methods for three different directions (i.e., longitudinal, sheet, transverse). Results:The fiber arrangements that were generated with FPM were in close agreement with the generated arrangements from FEM for all three directions. The mean angle difference between the FPM and FEM vector fields were lower than for the ventricular fiber arrangements and lower than for the atrial fiber arrangements. Discussion:The proposed meshless rule-based method was proven to generate myocardial fiber arrangements with very close agreement with FEM while alleviates the requirement for a mesh of the latter. This is of great value for cardiac electrophysiology solvers that are based on meshless methods since they require a well defined myocardial fiber arrangement to simulate accurately the propagation of electrical signals in the heart. Combining a meshless solution for both the determination of the fibers and the electrical signal propagation can allow for solution that do not require the definition of a mesh. To our knowledge, this work is the first one to propose a meshless rule-based method for myocardial fiber arrangement determination.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Steady-state and transient effects of SK channel block and adrenergic stimulation to counteract acetylcholine-induced arrhythmogenic effects in the human atria: a computational study

  • Celotto, Ch.
  • Sánchez, C.
  • Mountris, K. A.
  • Laguna, P.
  • Pueyo, E.
Hyperactivity of the parasympathetic nervous system has been linked to the development of paroxysmal atrial fibrillation (AF). The parasympathetic neurotransmitter acetylcholine (ACh) causes a reduction in action potential (AP) duration (APD) and an increase in resting membrane potential (RMP), both of which contribute to enhance the risk for reentry. Research suggests that small-conductance calcium activated potassium (SK) channels may be an effective target for treating AF. Therapies targeting the autonomic nervous system, either alone or in combination with other drugs, have been explored and have been shown to decrease the incidence of atrial arrhythmias. This study uses computational modeling and simulation to examine the impact of SK channel block (SKb) and-adrenergic stimulation through Isoproterenol (Iso) on countering the negative effects of cholinergic activity in human atrial cell and 2D tissue models. The steady-state effects of Iso and/or SKb on AP shape, APD at 90% repolarization (APD90) and RMP were evaluated. The ability to terminate stable rotational activity in cholinergically-stimulated 2D tissue models of AF was also investigated. A range of SKb and Iso application kinetics, which reflect varying drug binding rates, were taken into consideration. The results showed that SKb alone prolonged APD90 and was able to stop sustained rotors in the presence of ACh concentrations up to 0.01 M. Iso terminated rotors under all tested ACh concentrations, but resulted in highly-variable steady-state outcomes depending on baseline AP morphology. Importantly, the combination of SKb and Iso resulted in greater APD90 prolongation and showed promising anti-arrhythmic potential by stopping stable rotors and preventing re-inducibility.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies

  • Velarte, A.
  • Otín, A.
  • Pueyo, E.
  • Guimera, A.
  • Villa, R.
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Enhancing safety in hyperbaric environments through analysis of autonomic nervous system responses: a comparison of dry and humid conditions

  • Sánchez, Carlos
  • Hernando, Alberto
  • Bolea, Juan
  • Izquierdo, David
  • Rodríguez, Germán
  • Olea, Agustín
  • Lozano, María Teresa
  • Peláez-Coca, María Dolores
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability (HRV)-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the HRV after removing the influence of respiration, PHF⊥¯, and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, pNN50¯, indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the HRV indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

QT interval time lag in response to heart rate changes during stress test for Coronary Artery Disease diagnosis

  • Pérez, Cristina
  • Pueyo, Esther
  • Martínez, Juan Pablo
  • Viik, Jari
  • Laguna, Pablo
Background: Slow adaptation of the QT interval to abrupt changes in heart rate (HR) can enhance ventricular heterogeneity and has been suggested as a marker of arrhythmic risk. Most investigations on QT rate adaptation lag have been performed in response to step-like HR changes. However, abrupt HR changes are difficult to induce or observe in ECG recordings under ambulatory conditions. Objective: We aim to evaluate the power of indices related to the QT lag in response to ramp-like HR changes in stress test to assess CAD risk. Methods: We quantified the lag between the actual QT series and the memoryless expected QT series, which was obtained by fitting a hyperbolic regression model to the instantaneous QT and HR measurements in stages where their behavior could be assumed stationary. The proposed methodology was applied to analyze ECG stress tests of a subset of 448 patients presenting different risk levels for Coronary Artery Disease (CAD). The QT lag was estimated separately in the exercise and recovery phases. Results: An increase in the estimated QT lag during exercise (from 25 to 36 s) and a decrease during recovery (from 57 to 39 s) were associated with higher CAD risk. The difference between these lags showed significant capacity for CAD risk stratification. Conclusion: The QT lag in response to HR changes can be quantified from a stress test. QT lag values in response to ramp-like HR changes are in ranges comparable to those quantified from abrupt HR changes and show clinical significance to stratify CAD risk.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Dynamics of excitable cells: spike-adding phenomena in action

  • Barrio, Roberto
  • Ibáñez, Santiago
  • Jover-Galtier, Jorge A.
  • Lozano, Álvaro
  • Martínez, M. Ángeles
  • Mayora-Cebollero, Ana
  • Mayora-Cebollero, Carmen
  • Pérez, Lucía
  • Serrano, Sergio
  • Vigara, Rubén
We study the dynamics of action potentials of some electrically excitable cells: neurons and cardiac muscle cells. Bursting, following a fast–slow dynamics, is the most characteristic behavior of these dynamical systems, and the number of spikes may change due to spike-adding phenomenon. Using analytical and numerical methods we give, by focusing on the paradigmatic 3D Hindmarsh–Rose neuron model, a review of recent results on the global organization of the parameter space of neuron models with bursting regions occurring between saddle-node and homoclinic bifurcations (fold/hom bursting). We provide a generic overview of the different bursting regimes that appear in the parametric phase space of the model and the bifurcations among them. These techniques are applied in two realistic frameworks: insect movement gait changes and the appearance of Early Afterdepolarizations in cardiac dynamics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Fiber-Optic-Based System for High-Resolution Monitoring of Stretch in Excised Tissues

  • Velarte, Antonio
  • Otin, Aranzazu
  • Giménez-Gómez, Pablo
  • Muñoz-Berbel, Xavier
  • Pueyo, Esther
Cardiovascular diseases cause a high number of deaths nowadays. To improve these statistics, new strategies to better understand the electrical and mechanical abnormalities underlying them are urgently required. This study focuses on the development of a sensor to measure tissue stretch in excised tissues, enabling improved knowledge of biomechanical properties and allowing greater control in real time. A system made of biocompatible materials is described, which is based on two cantilevered platforms that integrate an optical fiber inside them to quantify the amount of stretch the tissues are exposed to with a precision of μm. The operating principle of the sensor is based on the variation of the optical path with the movement of the platforms onto which the samples are fixed. The conducted tests highlight that this system, based on a simple topology and technology, is capable of achieving the desired purpose (a resolution of ∼1 μm), enabling the tissue to be bathed in any medium within the system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Deep learning for chaos detection

  • Barrio, Roberto
  • Lozano, Álvaro
  • Mayora-Cebollero, Ana
  • Mayora-Cebollero, Carmen
  • Miguel, Antonio
  • Ortega, Alfonso
  • Serrano, Sergio
  • Vigara, Rubén
In this article, we study how a chaos detection problem can be solved using Deep Learning techniques. We consider two classical test examples: the Logistic map as a discrete dynamical system and the Lorenz system as a continuous dynamical system. We train three types of artificial neural networks (multi-layer perceptron, convolutional neural network, and long short-term memory cell) to classify time series from the mentioned systems into regular or chaotic. This approach allows us to study biparametric and triparametric regions in the Lorenz system due to their low computational cost compared to traditional techniques.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A Flexible PDMS-Based Optical Biosensor for Stretch Monitoring in Cardiac Tissue Samples

  • Sannino, Andrea
  • Velarte, Antonio
  • Otín, Aránzazu
  • Artigas, José Ignacio
  • Oliván-Viguera, Aida
Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane—where the samples are attached—which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10–30% stretches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cardiac electrophysiology meshfree modeling through the mixed collocation method

  • Mountris, Konstantinos A.
  • Pueyo, Esther
We present the meshfree mixed collocation method (MCM) for cardiac electrophysiology simulation. Capitalizing on the meshfree property of MCM, we introduce an immersed grid approach for automated generation of meshfree node grids from medical image data. This approach allows us to avoid the time-consuming mesh generation and processing that mesh-based methods like the finite element method (FEM) require. We employ the MCM to solve the cardiac monodomain model considering electrical propagation in 2D tissue sheets, 3D tissue slabs, and a realistic biventricular anatomy. We demonstrate that the solutions obtained by the MCM are in good agreement with the FEM, particularly when immersed grid is used. These findings confirm the suitability of the MCM for cardiac electrophysiology simulation and make the MCM a promising alternative to the FEM for cardiac electrical investigations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Right ventricular vs left bundle branch pacing-induced changes in ECG depolarization and repolarization

  • Sales Bellés, Clara
  • Palacios, Saúl
  • Melero, Jorge
  • Julián, Inés
  • Ramos, Javier
  • Pablo Martínez, Juan
  • Minchole, Ana
  • Pueyo, Esther
Patients suffering from bradycardia are indicated for pacemaker implantation. Right ventricular pacing (RVP)has been conventionally used for this purpose, but it can increase the risk of atrial fibrillation and heart failure. Left bundle branch area pacing (LBBAP) has been proposed as a new physiological pacing technique. The aim of this study was to compare changes induced by RVP and LBBAP in the ECG. 10-minute 12-lead ECG recordings were acquired at baseline and after pacemaker implantation from 83 patients (31 RVP, 52 LBBAP). Median beats were calculated for each patient at baseline and post-implantation states. ECG markers including QRS duration (dQRS)and area (aQRS) and heart rate-corrected QT (QTc) and Tpeak-to-Tend (Tpec) intervals were measured. dQRS and aQRS decreased significantly at post-implantation with respect to baseline, both being significantly lower for LBBAP than RVP after pacemaker implantation. QTc was significantly reduced at post-implantation for both pacing techniques with no differences between them. Tpec did not change either between states or techniques. In conclusion, LBBAP led to more synchronized ventricular depolarization, supporting potentially improved clinical outcomes with LBBAP as compared to RVP for anti-bradycardia therapy
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Characterization of the effects of right ventricular and left bundle branch area pacing on the QRS complex

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Vadillo Martin, P
  • Mayo Carlos, V
  • Palacios Rosales, S
  • Martinez Cortes, J P
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Right ventricular pacing (RVP) has been the treatment of choice for patients with atrioventricular block and sinus node disease for the last decades . It is well known that RVP ventricular may cause ventricular dyssynchrony and could lead to left ventricular dysfunction in 20% of patients, and therefore could increase the risk of heart failure, atrial fibrillation and cardiovascular mortality. Left bundle branch area pacing (LBBAP) has recently emerged as a new physiological pacing modality that can circumvent the limitations of RVP. The purpose of this study was to compare changes induced by RVP and LBBAP in the standard 12-lead ECG by the analysis of QRS complex characteristics in order to asses ventricular dyssynchrony. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) with indication for anti-bradycardia therapy were acquired before and after pacemaker implantation. Patients were grouped into narrow and wide baseline QRS using a threshold for the QRS duration of 120 ms. Median beats were calculated at baseline and 24 hours post-implantation states for each patient. ECG markers describing ventricular activation were measured, including: 1) QRS duration (QRSd) from QRS onset to QRS end; 2) QRS area (QRSa), computed from the individual areas in orthogonal X, Y and Z leads calculated using the Kors conversion matrix; 3) a new index QRS50 proposed to estimate the ventricular activation time from the first three components of the singular value decomposition of the median QRS complex. Results: Note that the QRS characteristics showed similar values in baseline for both pacing techniques. In patients with narrow QRS, we found that paced QRS characteristics remained similar from the basal QRS in LBBAP group whereas in RVP group they worsened. The three markers, QRSd, QRSa and QRS50, increased after RVP by 34 ms, 68 uVs and 22 ms, respectively (p<0,001). In patients with wide QRS, LBBAP significantly reduced QRSd, QRSa and QRS50 while RVP increased QRSa and QRS50 and left QRSd unchanged. Conclusion: In patients receiving a pacemaker for anti-bradycardia therapy, LBBAP led to more synchronized ventricular activation than RVP measured from QRS duration- and area-related characteristics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Depolarization-repolarization synchrony after right ventricular and left bundle branch area pacing

  • Sales Belles, C
  • Melero Polo, J
  • Cabrera Ramos, M
  • Minchole Lapuente, A
  • Pueyo Paules, E
  • Ramos Maqueda, J
Introduction: Left bundle branch area pacing (LBBAP) has been recently proposed to overcome the limitations associated with right ventricular pacing (RVP) and has been suggested as a new physiological pacing form with high feasibility and safety. A greater difference between QRS complex and T-wave angle directions has been proposed as a marker of abnormal electrical activity in several patient populations, but a comparison between these two pacing modalities has never been performed. The total cosine R to T (TCRT) is an ECG descriptor that accounts for depolarization-repolarization synchrony by measuring the difference between their directions. The purpose of this study was to compare TCRT in patients referred for RVP and LBBAP pacing as anti-bradycardia therapy. Methods: ECG recordings from 134 patients (82 LBBAP, 52 RVP) were classified into two groups, narrow QRS and wide QRS, depending on the patient’s QRS duration prior to implantation. In the post-implantation state, the TCRT index was calculated from a median beat calculated for each patient. Singular value decomposition was applied to the median beat in the eight independent ECG leads (I, II, V1, V2, V3, V4, V5, V6). The QRS complex and T wave loops in a three-dimensional space were determined from the first three components of the decomposition. TCRT was computed as the average of the cosines of the angles between the QRS complex directions and the maximum T wave direction. More positive values corresponded to more synchronized depolarization and repolarization processes while more negative values indicated larger differences in the orientation of the QRS and T wave loops and, therefore, greater dyssynchronization. Results: showed that TCRT took negative values for both techniques, RVP and LBBAP, and both groups, narrow and wide QRS, indicating that pacing generated dyssynchronization between ventricular depolarization and repolarization. Nevertheless, TCRT values for both groups were significantly more negative (p<0.01) for RVP than for LBBAP. We hypothesize that cardiac memory induced by pacing could account for these negative TCRT values. In any case, LBBAP did not increase the difference in the QRS complex and T wave loop orientations as much as RVP. Conclusion: LBBAP induces less dyssynchrony than RVP in the depolarization-repolarization process.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

QRS-T angles as markers for heart sphericity in subjects with intrauterine growth restriction: a simulation study

  • Bueno-Palomeque, Freddy L.
  • Mountris, Konstantinos A.
  • Ortigosa, Nuria
  • Bailón, Raquel
  • Bijnens, Bart
  • Crispi, Fàtima
  • Pueyo, Esther
  • Mincholé, Ana
  • Laguna, Pablo
Changes induced by intrauterine growth restriction (IUGR) in cardiovascular anatomy and function that persist throughout life have been associated with a higher predisposition to heart disease in adulthood. Together with cardiac morphological remodelling, evaluated through the ventricular sphericity index, alterations in cardiac electrical function have been reported by characterization of the depolarization and repolarization loops, and their angular relationship, measured from the vectorcardiogram. The underlying relationship between the morphological remodelling and the angular variation of QRS and T-wave dominant vectors, if any, has not been explored. The aim of this study was to evaluate this relationship using computational models based on realistic heart and torso in which IUGR-induced morphological changes were incorporated by reducing the ventricular sphericity index. Specifically, we departed from a control model and we built eight different globular heart models by reducing the base-to-apex length and enlarging the basal ventricular diameter. We computed QRS and T-wave dominant vectors and angles from simulated pseudo-electrocardiograms and we compared them with clinical measurements. Results for the QRS to T angles follow a change trend congruent with that reported in clinical data, supporting the hypothesis that the IUGR-induced morphological remodelling could contribute to explain the observed angle changes in IUGR patients. By additionally varying the position of the ventricles with respect to the torso and the electrodes, we found that electrode displacement can impact the quantified angles and should be considered when interpreting the results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Interindividual Age-Independent Differences in Human CX43 Impact Ventricular Arrhythmic Risk

  • García-Mendívil, Laura
  • Pérez-Zabalza, María
  • Oliver-Gelabert, Antoni
  • Vallejo-Gil, José María
  • Fañanás-Mastral, Javier
  • Vázquez-Sancho, Manuel
  • Bellido-Morales, Javier André
  • Vaca-Núñez, Alexánder Sebastián
  • Ballester-Cuenca, Carlos
  • Diez, Emiliano
  • Ordovás, Laura
  • Pueyo, Esther
Connexin 43 (CX43) is one of the major components of gap junctions, the structures responsible for the intercellular communication and transmission of the electrical impulse in the left ventricle. There is limited information on the histological changes of CX43 with age and their effect on electrophysiology, especially in humans. Here, we analyzed left ventricular biopsies from living donors starting at midlife to characterize age-related CX43 remodeling. We assessed its quantity, degree of lateralization, and spatial heterogeneity together with fibrotic deposition. We observed no significant age-related remodeling of CX43. Only spatial heterogeneity increased slightly with age, and this increase was better explained by biological age than by chronological age. Importantly, we found that CX43 features varied considerably among individuals in our population with no relevant relationship to age or fibrosis content, in contrast to animal species. We used our experimental results to feed computational models of human ventricular electrophysiology and to assess the effects of interindividual differences in specific features of CX43 and fibrosis on conduction velocity, action potential duration, and arrhythmogenicity. We found that larger amounts of fibrosis were associated with the highest arrhythmic risk, with this risk being increased when fibrosis deposition was combined with a reduction in CX43 amount and/or with an increase in CX43 spatial heterogeneity. These mechanisms underlying high arrhythmic risk in some individuals were not associated with age in our study population. In conclusion, our data rule out CX43 remodeling as an age-related arrhythmic substrate in the population beyond midlife, but highlight its potential as a proarrhythmic factor at the individual level, especially when combined with increased fibrosis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mathematical birth of early afterdepolarizations in a cardiomyocyte model

  • Barrio, R.
  • Jover-Galtier, J.A.
  • Martínez, M.A.
  • Pérez, L.
  • Serrano, S.
Early Afterdepolarizations (EADs) are abnormal behaviors that can lead to cardiac failure and even cardiac death. In this paper we investigate the occurrence and development of these phenomena in a reduced Luo–Rudy cardiac model. Through a comprehensive dynamical analysis, we map out the distinct patterns observed in the parametric plane, differentiating between normal beats without EADs and pathological beats with EADs. By examining the bifurcation structure of the model, we elucidate the dynamical elements associated with these patterns and their transitions. Using a fast–slow analysis, we explore the emergence and evolution of EADs in the model. Notably, our approach combines the two commonly used fast–slow approaches (1-slow–2-fast and 2-slow–1-fast), and we show how both approaches together provide a more complete understanding of this phenomenon.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The frequency of atrial fibrillatory waves is modulated by the spatiotemporal pattern of acetylcholine release: a 3D computational study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Rodriguez Matas, Jose F.
  • Laguna, Pablo
  • Pueyo, Esther
In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, Ff, shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh(t), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations (ACh̄) and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in Ff, Ff(t), followed the simulated temporal ACh(t) pattern in all cases. The temporal mean of Ff(t), F̄f, depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and ACh̄. The magnitude of Ff(t) modulation, ΔFf, depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on F̄f and only a mild impact on ΔFf. The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Experimentally-guided in silico design of engineered heart tissues to improve cardiac electrical function after myocardial infarction

  • Rosales, Ricardo M.
  • Mountris, Konstantinos A.
  • Oliván-Viguera, Aida
  • Pérez-Zabalza, María
  • Cedillo-Servin, Gerardo
  • Iglesias-García, Olalla
  • Hrynevich, Andrei
  • Castilho, Miguel
  • Malda, Jos
  • Prósper, Felipe
  • Doblaré, Manuel
  • Mazo, Manuel M.
  • Pueyo, Esther
Engineered heart tissues (EHTs) built from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) showed promising results for cardiac function restoration following myocardial infarction. Nevertheless, human iPSC-CMs have longer action potential and lower cell-to-cell coupling than adult-like CMs. These immature electrophysiological properties favor arrhythmias due to the generation of electrophysiological gradients when hiPSC-CMs are injected in the cardiac tissue. Culturing hiPSC-CMs on three-dimensional (3D) scaffolds can promote their maturation and influence their alignment. However, it is still uncertain how on-scaffold culturing influences the overall electrophysiology of the in vitro and implanted EHTs, as it requires expensive and time consuming experimentation. Here, we computationally investigated the impact of the scaffold design on the EHT electrical depolarization and repolarization before and after engraftment on infarcted tissue. We first acquired and processed electrical recordings from in vitro EHTs, which we used to calibrate the modeling and simulation of in silico EHTs to replicate experimental outcomes. Next, we built in silico EHT models for a range of scaffold pore sizes, shapes (square, rectangular, auxetic, hexagonal) and thicknesses. In this setup, we found that scaffolds made of small (0.2 mm2), elongated (30° half-angle) hexagons led to faster EHT activation and better mimicked the cardiac anisotropy. The scaffold thickness had a marginal role on the not engrafted EHT electrophysiology. Moreover, EHT engraftment on infarcted tissue showed that the EHT conductivity should be at least 5% of that in healthy tissue for bidirectional EHT-myocardium electrical propagation. For conductivities above such threshold, the scaffold made of small elongated hexagons led to the lowest activation time (AT) in the coupled EHT-myocardium. If the EHT conductivity was further increased and the hiPSC-CMs were uniformly oriented parallel to the epicardial cells, the total AT and the repolarization time gradient decreased substantially, thus minimizing the likelihood for arrhythmias after EHT transplantation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Coupling of neurons favors the bursting behavior and the predominance of the tripod gait

  • Serrano, S.
  • Barrio, R.
  • Lozano, Á.
  • Mayora-Cebollero, A.
  • Vigara, R.
In nature, it has been observed that the dominant locomotor pattern of hexapod insects is often the tripod gait. Our analysis of a Central Pattern Generator (CPG) of the insect movement gives reasons for this dominance: the mathematical CPG model presents the tripod pattern with bursting dynamics in a parametric region where an isolated neuron has a simpler behavior. That is, we show how the coupling of small networks of neurons makes the system to continue having bursting dynamics even when an isolated neuron would be spiking. Moreover, in parametric regions where a neuron shows chaotic dynamics, the CPG exhibits a chaotic synchronization phenomenon: the chaotic tripod gait. In other words, coupling loves bursting… and tripod gait. The hyperchaotic phenomenon is also present and we locate regions where up to four Lyapunov exponents are positive.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Performance evaluation of QT-RR adaptation time lag estimation in exercise stress testing

  • Pérez, C.
  • Pueyo, E.
  • Martínez, J. P.
  • Viik, J.
  • Sornmo, L.
  • Laguna, P.
Background: Slower adaptation of the QT interval to sudden changes in heart rate has been identified as a risk marker of ventricular arrhythmia. The gradual changes observed in exercise stress testing facilitates the estimation of the QT-RR adaptation time lag. Methods: The time lag estimation is based on the delay between the observed QT intervals and the QT intervals derived from the observed RR intervals using a memoryless transformation. Assuming that the two types of QT interval are corrupted with either Gaussian or Laplacian noise, the respective maximum likelihood time lag estimators are derived. Estimation performance is evaluated using an ECG simulator which models change in RR and QT intervals with a known time lag, muscle noise level, respiratory rate, and more. The accuracy of T-wave end delineation and the influence of the learning window positioning for model parameter estimation are also investigated. Results: Using simulated datasets, the results show that the proposed approach to estimation can be applied to any changes in heart rate trend as long as the frequency content of the trend is below a certain frequency. Moreover, using a proper position of the learning window for exercise so that data compensation reduces the effect of nonstationarity, a lower mean estimation error results for a wide range of time lags. Using a clinical dataset, the Laplacian-based estimator shows a better discrimination between patients grouped according to the risk of suffering from coronary artery disease. Conclusions : Using simulated ECGs, the performance evaluation of the proposed method shows that the estimated time lag agrees well with the true time lag.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Differences in ventricular wall composition may explain inter-patient variability in the ECG response to variations in serum potassium and calcium

  • Bukhari, Hassaan A.
  • Sánchez, Carlos
  • Laguna, Pablo
  • Potse, Mark
  • Pueyo, Esther
Objective: Chronic kidney disease patients have a decreased ability to maintain normal electrolyte concentrations in their blood, which increases the risk for ventricular arrhythmias and sudden cardiac death. Non-invasive monitoring of serum potassium and calcium concentration, [K + ] and [Ca 2+ ], can help to prevent arrhythmias in these patients. Electrocardiogram (ECG) markers that significantly correlate with [K + ] and [Ca 2+ ] have been proposed, but these relations are highly variable between patients. We hypothesized that inter-individual differences in cell type distribution across the ventricular wall can help to explain this variability.Methods: A population of human heart-torso models were built with different proportions of endocardial, midmyocardial and epicardial cells. Propagation of ventricular electrical activity was described by a reaction-diffusion model, with modified Ten Tusscher-Panfilov dynamics. [K + ] and [Ca 2+ ] were varied individually and in combination. Twelve-lead ECGs were simulated and the width, amplitude and morphological variability of T waves and QRS complexes were quantified.Results: Both simulations and patients data showed that most of the analyzed T wave and QRS complex markers correlated strongly with [K + ] (absolute median Pearson correlation coefficients, r, ranging from 0.68 to 0.98) and [Ca 2+ ] (ranging from 0.70 to 0.98). The same sign and similar magnitude of median r was observed in the simulations and the patients. Different cell type distributions in the ventricular wall led to variability in ECG markers that was accentuated at high [K + ] and low [Ca 2+ ], in agreement with the larger variability between patients measured at the onset of HD. The simulated ECG variability explained part of the measured inter-patient variability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Dominant patterns in small directed bipartite networks: ubiquitous generalized tripod gait

  • Lozano, Álvaro
  • Vigara, Rubén
  • Mayora-Cebollero, Carmen
  • Barrio, Roberto
The synchronization patterns exhibited by small networks of neurons that regulate biological processes (CPGs) have aroused growing scientific interest. In many of these networks there is a main behavioral pattern within the parameter space. In particular, in the context of insect locomotion, tripod walking stands out as a predominant pattern, both in natural observations (where insects walk on tripod gait) and in mathematical models. This predominance appears to be stable under parameter variations within the network, suggesting a possible correlation with the underlying network topology. Tripod walking can be naturally extended to all CPGs with a bipartite connectivity. Then a natural question arises: Are “generalized tripod gaits” equally dominant among synchronization patterns within those networks? To investigate this, we carried out a comprehensive study covering all bipartite networks of up to nine neurons. For each of those networks we numerically explore the phase space using a quasi-MonteCarlo method to see what are the main synchronization patterns that the network can achieve. Then, all those patterns are grouped according to their dynamics. Generalized tripod gait was observed in all cases examined as the dominant pattern again. However, certain cases revealed additional stable patterns, mainly associated with the 3-colorings of the respective graph structures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Understanding the role of B cells in CAR T-cell therapy in leukemia through a mathematical model

  • Serrano, Sergio
  • Barrio, Roberto
  • Martínez-Rubio, Álvaro
  • Belmonte-Beitia, Juan
  • Pérez-García, Víctor M.
Chimeric antigen receptor T (CAR T) cell therapy has been proven to be successful against a variety of leukemias and lymphomas. This paper undertakes an analytical and numerical study of a mathematical model describing the competition of CAR T, leukemia, tumor, and B cells. Considering its significance in sustaining anti-CD19 CAR T-cell stimulation, a B-cell source term is integrated into the model. Through stability and bifurcation analyses, the potential for tumor eradication, contingent on the continuous influx of B cells, has been revealed, showing a transcritical bifurcation at a critical B-cell input. Additionally, an almost heteroclinic cycle between equilibrium points is identified, providing a theoretical basis for understanding disease relapse. Analyzing the oscillatory behavior of the system, the time-dependent dynamics of CAR T cells and leukemic cells can be approximated, shedding light on the impact of initial tumor burden on therapeutic outcomes. In conclusion, the study provides insights into CAR T-cell therapy dynamics for acute lymphoblastic leukemias, offering a theoretical foundation for clinical observations and suggesting avenues for future immunotherapy modeling research.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Full Lyapunov exponents spectrum with Deep Learning from single-variable time series

  • Mayora-Cebollero, Carmen
  • Mayora-Cebollero, Ana
  • Lozano, Álvaro
  • Barrio, Roberto
In this article we study if a Deep Learning technique can be used to obtain an approximate value of the Lyapunov exponents of a dynamical system. Moreover, we want to know if Machine Learning techniques are able, once trained, to provide the full Lyapunov exponents spectrum with just single-variable time series. We train a Convolutional Neural Network and use the resulting network to approximate the full spectrum using the time series of just one variable from the studied systems (Lorenz system and coupled Lorenz system). The results are quite surprising since all the values are well approximated with only partial data. This strategy allows to speed up the complete analysis of the systems and also to study the hyperchaotic dynamics in the coupled Lorenz system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mathematical Model of CAR T-Cell Therapy for a B-Cell Lymphoma Lymph Node

  • Sabir, Soukaina
  • León-Triana, Odelaisy
  • Serrano, Sergio
  • Barrio, Roberto
  • Pérez-García, Victor M.
CAR T-cell therapies have demonstrated significant success in treating B-cell leukemia in children and young adults. However, their effectiveness in treating B-cell lymphomas has been limited in comparison to leukemia. In this paper we present a mathematical model that elucidates the dynamics of diffuse large B-cell lymphoma and CAR T-cells in a lymph node. The mathematical model aids in understanding the complex interplay between the cell populations involved and proposes ways to identify potential underlying dynamical causes of treatment failure. We also study the phenomenon of immunosuppression induced by tumor cells and theoretically demonstrate its impact on cell dynamics. Through the examination of various response scenarios, we underscore the significance of product characteristics in treatment outcomes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Compact System for Stimulation and Recording of Field Potentials from Cardiac Tissue Preparations

  • Velarte, Antonio
  • Castel, Antonio
  • Otín, Aránzazu
  • Pueyo, Esther
The recording of extracellular field potentials from cardiac tissues or cardiomyocytes can provide relevant information for the study of cardiovascular diseases and the effects of drugs. Cardiac field potentials are commonly acquired using commercial systems based on microelectrode arrays, which are expensive and lack flexibility, thus precluding a more extensive use in cardiac research. In this work, an easily configurable, open-source system is presented, which is based on a modular and flexible architecture. The proposed system offers a customizable and low-cost solution that could enable greater accessibility to electrophysiological studies of cardiac cells and tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

ECG-based evaluation of ventricular synchrony in left bundle branch area pacing through characterization of the activation sequence

  • Sales-Belles, Clara
  • Mincholé, Ana
  • Melero-Polo, Jorge
  • Cabrera-Ramos, Mercedes
  • Vadillo-Martín, Pablo
  • Montilla-Padilla, Isabel
  • Sorinas-Villanueva, Laura
  • Julián-García, Inés
  • Mayo-Carlos, Gualber Vitto
  • Ruiz-Arroyo, José Ramón
  • Pueyo, Esther
  • Ramos-Maqueda, Javier
Left bundle branch area pacing (LBBAP) overcomes ventricular dyssynchrony induced by conventional right ventricular pacing (RVP). Despite QRS duration (QRSd) being the standard ECG marker for biventricular synchrony, it lacks insights into the ventricular activation sequence. Our aim is to assess biventricular synchrony by characterizing the ventricular activation sequence and introducing robust markers using the 12-lead ECG. A prospective single-center study was conducted, involving patients with pacemaker indication due to bradycardia. Patients were divided into LBBAP and RVP, and classified by baseline-QRS morphology. To assess biventricular synchrony, low frequency-based QRS analysis was performed to compute the ventricular activation sequence and precordial activation delay (pAD). Additional QRS markers including QRSd, QRS60, and QRS area (QRSa) were calculated. A total of 176 patients (107 LBBAP, 69 RVP) were included. The paced ventricular activation sequence indicated a more physiological pattern after LBBAP than RVP, with lower pAD values in narrow QRS, RBBB, and LBBB subgroups [ − 10( − 20,14) vs. 26(5, 39) ms;  − 18( − 30,  − 8) vs. 34(26, 55) ms; 10( − 14, 25) vs. 32(12, 48) ms] (p < 0.01). In all subgroups, QRS60 showed lower values after LBBAP than RVP [52(41, 62) vs.73(65, 80) ms; 60(55, 66) vs. 77(67, 83) ms; 59(53, 64) vs. 77(74, 82) ms] (p < 0.01) and QRSa were also lower [53(38, 66) vs. 121(92, 143) μVs; 60(50, 89) vs. 124(97, 159) μVs; 62(52, 80) vs. 133(99, 148) μVs] (p < 0.01). pAD provides valuable insights into ventricular activation beyond paced-QRSd. Together with QRS60 and QRSa, pAD could be a promising tool to assess biventricular synchrony.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tilt-induced changes in f-wave characteristics during atrial fibrillation: an experimental and computational investigation

  • Abdollahpur, Mostafa
  • Celotto, Chiara
  • Sánchez, Carlos
  • Plappert, Félix
  • Östenson, Sten
  • Platonov, Pyotr G.
  • Laguna, Pablo
  • Pueyo, Esther
  • Sandberg, Frida
Introduction This study explores transient and stationary effects of sympathetic and parasympathetic stimulation on f-wave characteristics in atrial fibrillation (AF) patients undergoing a tilt test. Transient phase is defined as the initial 2-minute interval following each postural change, reflecting immediate autonomic adaptation, whereas steady phase refers to the subsequent interval (from 3 minutes post-change until phase end) representing a stable autonomic state. Methods Our primary aim is to investigate how the two branches of the autonomic nervous system (ANS) influence the f-wave frequency time series (f(m)). An analysis of f(m) in terms of the mean over time (Ff) and the magnitude of respiration-modulated f(m) variations (ΔFf) is conducted during baseline supine rest (B), head-down tilt (HDT) and head-up tilt (HUT). We analyzed data from a previous study in which 24 patients with persistent AF underwent a tilt test protocol, during which electrocardiograms (ECGs) were recorded. A model-based method was used to extract f(m) series from the ECG. Subsequently, an orthogonal subspace projection method was employed to quantify ΔFf, considering an ECG-derived respiratory signal. Electrophysiological computational simulations were conducted on 2D and 3D human atrial persistent AF models to aid the interpretation of clinical findings. Various levels of cholinergic stimulation by acetylcholine and β-adrenergic stimulation by isoproterenol were tested in the models. The temporal modulation of acetylcholine, representing changes associated with respiration, was cyclically modeled using sinusoidal waveforms. Results Analysis of the clinical data showed a decrease in Ff from B to HDT and an increase from HDT to HUT. During HDT, ΔFf initially increased in the transient phase before decreasing in the steady phase, then rose again during HUT. Analysis of the simulated data showed that increasing the concentration of Isoproterenol and/or acetylcholine resulted in a rise in Ff. Additionally, the magnitude of ΔFf was shown to be associated with the extent of acetylcholine fluctuation. Discussion These results suggest that changes in f-wave frequency characteristics during HUT and HDT could be linked to changes in sympathetic activity, with parasympathetic activity possibly modulating the effects of sympathetic activity rather than being an independent driver of fibrillatory rate changes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Optical fiber integration in PDMS devices for dynamic tissue deformation

  • Velarte, Antonio
  • Sannino, Andrea
  • Otin, Aranzazu
  • Santamaría, Beatriz
  • Artigas, José Ignacio
  • Pueyo, Esther
This study introduces an advanced optical fiber-based stretchable sensing platform designed for precise biomechanical characterization in tissue engineering applications, specifically tailored for cardiac tissue studies. The system is entirely fabricated from biocompatible polydimethylsiloxane (PDMS) material, and features a thin upper membrane and an internal cavity where controlled pneumatic deformation occurs. Deformation is quantified through changes in optical intensity measured through a strategically aligned optical fiber pair, as membrane stretching disrupts total internal reflection conditions. Finite element modeling using COMSOL is used to optimize device geometry and predict deformation, which is subsequently validated through experimental analyses. A custom-designed electronic system with capacity for real-time signal processing ensures stable and sensitive data acquisition. The experimental results show high levels of linearity and repeatability in a physiologically relevant stretch range, highlighting its potential for biomechanical research applications and dynamic tissue stimulation. Future improvements are directed toward extending the reliable deformation operating range through advances in the optical system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Deep Learning for analyzing chaotic dynamics in biological time series: Insights from frog heart signals

  • Mayora-Cebollero, Carmen
  • Fenton, Flavio H.
  • Halprin, Molly
  • Herndon, Conner
  • Toye, Mikael J.
  • Barrio, Roberto
The study of experimental data is a relevant task in several physical, chemical and biological applications. In particular, the analysis of chaotic dynamics in cardiac systems is crucial as it can be related to certain pathological arrhythmias. When working with short and noisy experimental time series, some standard techniques for chaos detection cannot provide reliable results because of such data characteristics. Moreover, when small datasets are available, some Deep Learning techniques cannot be applied directly (that is, using part of the data to train the network, and using the trained network to analyze the remaining dataset). To overcome all these limitations, we propose an automatic algorithm that combines Deep Learning and some selection strategies based on a mathematical model of the same nature of the experimental data. To demonstrate its performance, we test it with experimental data obtained from ex-vivo frog heart experiments, achieving highly accurate results.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Nonlinear study of interacting population with increasing functional response: The significance of fear and movement

  • Gupta, R.P.
  • Singh, Harinand
  • Barrio, Roberto
  • Kumar, Arun
The study of hunting cooperation and fear effects is emerging as important ecological factors in population dynamics. These two features are analyzed independently in the literature by several researchers in detail. It is observed that both effects are important but poorly understood mechanisms that mediate the way predators organize ecosystems. The literature suggests that the outcomes of predator–prey interactions and their impact on ecosystems can be influenced together by these two factors. Therefore, we review the expanding body of research that integrates hunting cooperation and/or the effect of fear phenomena into the ecology of predator–prey. Our aim is to provide a framework for examining how the increasing type of functional response is affected by fear factor. The temporal dynamics, including the stability and bifurcation analysis of the system, is discussed briefly. Various parametric planes are analyzed to identify the regions of stability, instability, and bistability, along with some invariant manifolds in the phase plane that divide the basins of attraction. The temporal model is extended to the spatiotemporal framework to capture the movements of populations, and the conditions for Turing instability are derived, revealing spatial dynamics that produce various Turing patterns (spots, stripes, and mixed type) in response to the changes in fear effect and diffusion coefficients. Extensive numerical simulations are also performed to illustrate the dynamics of the model in temporal and spatio-temporal contexts.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Sudden cardiac death risk prediction from QT–RR adaptation time lag computed from exercise stress test ECG

  • Pérez, Cristina
  • Martínez, Juan Pablo
  • Ramírez, Julia
  • Kenttä, Tuomas
  • Junttila, Juhani
  • Kiviniemi, Antti
  • Perkiömäki, Juha
  • Huikuri, Heikki
  • Pueyo, Esther
  • Laguna, Pablo
Objetive: This study aims to evaluate the QT adaptation time following gradual heart rate changes estimated from exercise stress test (EST) ECGs as a marker of sudden cardiac death (SCD) risk. The predicted risk value for any cardiovascular death (CVD) is also evaluated. Methods: Three ECG-derived markers related to QT-RR adaptation time were estimated during the exercise phase of EST, τe, during the recovery phase, τr, and as the difference between them, Δτ. The values were computed from patients with coronary artery disease (CAD) from ARTEMIS study (N=1472; median follow-up of 8.9 years). These markers are calculated as the delay between the observed RR interval series and a patient-specific memoryless RR series computed from the QT interval (RR-based strategy). Alternatively, the estimates were calculated as the delay between the observed QT intervals and a patient-specific instantaneous QT series computed from the RR intervals (QT-based strategy). The relation between the markers and CAD or SCD was evaluated. Results: The marker τr is more robustly estimateed with the RR-based strategy and is able to stratify survivors and victims of either SCD or CVD (p-value equal to 0.022 and 0.065, respectively). Multivariable regression models for predicting SCD and CVD include the QT-RR adaptation time estimated in the recovery phase of EST using the RR-based strategy. Conclusion: A prolonged QT-RR adaptation time during the recovery phase of the EST ECG, calculated with the RR-based strategy, can predict SCD and CVD, providing complementary information to other clinical markers
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Bregman Proximal Gradient with extrapolation to train a Reservoir Computing network for a binary classification task

  • Mayora-Cebollero, Carmen
  • Mayora-Cebollero, Ana
  • Lozano, Álvaro
  • Barrio, Roberto
This study examines the training process of Artificial Neural Networks, specifically focusing on Reservoir Computing and on binary classification tasks. Training involves optimizing the network’s parameters to minimize the error of a loss function, which quantifies the discrepancy between network outputs and target data. Several numerical optimizers are used in the literature. Here, we formulate the supervised learning problem using the recently introduced Bregman Proximal Gradient with extrapolation (BPGe) algorithm for non-convex optimization problems. We compare this new method with the classical Stochastic Gradient Descent (SGD), the Root Mean Square Propagation (RMSProp), the Adaptive Moment Estimation (Adam), and two variants with Nesterov momentum (NAG and NAdam). The new approach leads to an accurate and significantly faster numerical algorithm for solving supervised learning problems on binary classification tasks in Reservoir Computing. Three test examples are presented, one based on chaotic data classification in the classical Lorenz system, another on the Human Activity Recognition (HAR) using smartphones dataset for movement–rest classification, and the last one on the MNIST dataset for even–odd classification. We show that our approach is highly competitive with existing methods in the tests performed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A modular soft core-based system for affordable acquisition and processing of electrophysiological recordings

  • Velarte, Antonio
  • Castel, Antonio
  • Otin, Aranzazu
  • Olivan-Viguera, Aida
  • Pueyo, Esther
Flexible low-cost platforms for high-fidelity recording of biological signals are essential to advance health monitoring applications, yet they often rely on proprietary hardware that is resource-intensive and expensive. This study introduces a cost-effective FPGA platform that embeds an ARM Cortex M1 soft core processor with custom logic for signal acquisition, signal conditioning, artifact suppression, and data management, which is built around an Intan RHD2000 headstage. On-chip routines perform automatic offset calibration and gain calibration to ensure measurement fidelity. A graphical user interface, co-developed with biomedical end users, ensures compliance with data rate and timing constraints, enables live visualization, and streamlines parameter configuration. Bench validation using a multichannel test generator reproducing cardiac field potentials up to  ± 2 mV and bandwidths up to 5 kHz demonstrated stable timing, low crosstalk, and accurate amplitude reconstruction. Platform performance matches that of commercial multielectrode array systems, with minor deviations attributed to interconnection effects. Together, these results provide an accessible and extensible platform that preserves measurement fidelity while lowering the barrier to adoption in resource constrained laboratories.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Real-time assessment of inter and intraventricular synchrony in cardiac resynchronization therapy with left bundle branch pacing using ECGi and low-frequency QRS analysis

  • Sales-Belles, Clara
  • Mincholé, Ana
  • Cabrera-Ramos, Mercedes
  • Melero-Polo, Jorge
  • Pueyo, Esther
  • Ramos Maqueda, Javier
Introduction: Left bundle branch pacing (LBBP) is an alternative to conventional biventricular pacing for cardiac resynchronization therapy (CRT). Methods: A 76-year-old male was referred for CRT via left bundle branch pacing (LBBP). We present the real-time characterization of the transition from intrinsic left bundle branch block (LBBB) to sequential pacing modalities: right ventricular septal pacing (RVSP), left ventricular septal pacing (LVSP), and finally LBBP. Epicardial activation maps from electrocardiographic imaging (ECGi) and low-frequency (LF) QRS analysis were used to provide complementary insights into interand intraventricular synchrony. Results: LVSP, LBBP, and anodal capture improved activation compared with baseline, with LBBP achieving the greatest improvements in interventricular and LV intraventricular synchrony despite higher RV dispersion. Conclusion: These findings highlight ECGi and LF QRS as valuable tools to guide CRT.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography

  • Palacios, Saúl
  • Smisek, Radovan
  • Curila, Karol
  • Nguyen, Uyen
  • Prinzen, Frits W.
  • Halamek, Josef
  • Plesinger, Filip
  • Jurak, Pavel
  • Ramos, Javier
  • Martínez, Juan Pablo
  • Pueyo, Esther
Background: Physiological pacing targeting the cardiac conduction system is increasingly being adopted as an alternative to conventional right ventricular (RV) pacing for the treatment of bradyarrhythmias, although its effects on ventricular repolarization remain underexplored. Objective: This study evaluates depolarization and repolarization responses to different pacing techniques using ultra-high-frequency electrocardiograms (UHF-ECGs). Methods: Temporary pacing was performed at different cardiac areas in 178 patients with bradycardia. Depolarization was assessed via QRS duration (QRSd), QRS area (QRSa), ventricular dyssynchrony (e-DYS), and activation time dispersion (dAT computed from leads V1-V6 and dAT4-6 from leads V1-V6). Repolarization was analyzed using the corrected QT interval (QTc), T-wave area (Ta), Periodic Repolarization Dynamics (PRD), and repolarization time dispersion (dRTc and dRTc4-6). Results: His bundle pacing (HBP) preserved ventricular activation patterns similar to spontaneous rhythm. Left bundle branch pacing (LBBP) induced moderate depolarization changes, primarily due to delayed right ventricular activation, while maintaining left ventricular synchrony. In particular, dAT showed no significant differences between HBP and spontaneous rhythm, while differences between LBBAP and spontaneous rhythm were significant but below 7 ms in median. When restricted to the left ventricle (LV), no significant differences in dAT4-6 were found between LBBAP and spontaneous rhythm. Importantly, e-DYS for HBP showed similar values to spontaneous rhythm, LBBP led to a significant reduction (median differences approximately 20 ms), and RVP was associated with a significant increase (above 15 ms in median). In line with these results, QRSd and QRSa showed the largest values for RVP. In terms of ventricular repolarization, median differences in the QTc interval between pacing modes and spontaneous rhythm were below 3 ms for HBP, above 1 ms for LBBP, and above 20 ms for RVP. All pacing modes led to a reduction in PRD, with the most marked reductions observed for LBBP, particularly for selective LBBP, with median changes with respect to spontaneous rhythm of 4.6 degrees. RT and RTc showed similar trends for all pacing techniques. Ta, however, showed median differences with respect to spontaneous rhythm above 100 and 34 µ Vs when pacing the RV at the apex and the septum, respectively, whereas such median differences were below 16µ Vs for HBP and below 2 µ Vs for LBBP. Conclusion: Physiological stimulation via HBP or LBBAP generates ventricular depolarization and repolarization responses that more closely resembles that of spontaneous rhythm, in high contrast to the largely different response induced by RV pacing. HBP and LBBAP have distinct technical characteristics, including differences in capture thresholds, lead stability, and procedural aspects. These techniques serve as alternatives to conventional RV pacing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Understanding tonic–clonic seizure transitions as secondary bifurcations in a neural field model

  • Cattell, O.
  • Mayora-Cebollero, A.
  • O'Dea, R. D.
  • Barrio, R.
  • Coombes, S.
Epilepsy is a dynamic complex disease involving a paroxysmal change in the activity of millions of neurons, often resulting in seizures. Tonic–clonic seizures are a particularly important class of these and have previously been theorized to arise in systems with an instability from one temporal rhythm to another via a quasi-periodic transition. We show that a recently introduced class of next-generation neural field models has a sufficiently rich bifurcation structure to support such behaviour. A linear stability analysis of the space-clamped model is used to uncover the conditions for a Hopf–Hopf bifurcation whereby two incommensurate frequencies can be excited. This is used to seed a more exhaustive numerical bifurcation analysis that highlights the preponderance of the model to generate torus bifurcations. Since the neural field model is derived from a biophysically meaningful spiking tissue model, we are able to highlight the neurobiological mechanisms that can underpin tonic–clonic seizures as they relate to levels of excitability, electrical and chemical synaptic coupling and the speed of action potential propagation. We further show how spatio-temporal patterns of activity can evolve in the fully nonlinear regime using direct numerical simulations far from a Turing bifurcation.